• Title/Summary/Keyword: On/off 제어

Search Result 1,210, Processing Time 0.031 seconds

Design of IoT-based Energy Monitoring System for Residential Building (IoT 기반 주택형 건물 에너지 모니터링 시스템 설계)

  • Lee, Min-Goo;Jung, Kyung-Kwon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.6
    • /
    • pp.1223-1230
    • /
    • 2021
  • Recently, energy resource management is a major concern around the world. Energy management activities minimize environmental impacts of the energy production. This paper presents design and prototyping of a home electric energy monitoring system that provides residential consumers with real time information about their electricity use. The developed system is composed of an in-house sensing system and a server system. The in-home sensing system is a set of wireless smart plug which have an AC power socket, a relay to switch the socket ON/OFF, a CT sensor to sense current of load appliance and a Kmote. The Kmote is a wireless communication interface based on TinyOS. Each sensing node sends its detection signal to a home gateway via wireless link. The home gateway stores the received signals into a remote database. The server system is composed of a database server and a web server, which provides web-based monitoring system to residential consumers. We analyzed and presented energy consumption data from electrical appliances for 3 months in home. The experimental results show the promising possibilities to estimate the energy consumption patterns and the current status.

Determination of Proper Irrigation Scheduling for Automated Irrigation System based on Substrate Capacitance Measurement Device in Tomato Rockwool Hydroponics (토마토 암면재배에서 정전용량 측정장치를 기반으로 한 급액방법 구명)

  • Han, Dongsup;Baek, Jeonghyeon;Park, Juseong;Shin, Wonkyo;Cho, Ilhwan;Choi, Eunyoung
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.366-375
    • /
    • 2019
  • This experiment aims to determine the proper irrigation scheduling based on a whole-substrate capacitance using a newly developed device (SCMD) by comparing with the integrated solar radiation automated irrigation system (ISR) and sap flow sensor automated irrigation system (SF) for the cultivation of tomato (Solanum lycopersicum L. 'Hoyong' 'Super Doterang') during spring to winter season. For the SCMD system, irrigation was conducted every 10 minutes after the first irrigation was started until the first run-off was occurred, of which the substrate capacitance was considered to be 100%. When the capacitance threshold (CT) was reached to the target point, irrigation was re-conducted. After that, when the target drain volume (TDV) was occurred, the irrigation stopped. The irrigation volume per event for the SCMD was set to 50, 75, or 100 mL at CT 0.9 and TDV 100 mL during the spring to summer cultivation, and the CT was set to 0.65, 0.75, 0.80, or 0.90 in the winter cultivation. When the irrigation volume per event was set to 50, 75, or 100 mL, the irrigation frequency in a day was 39, 29, and 19, respectively, and the drain rate was 3.04, 9.25, and 20.18%, respectively. When the CT was set to 0.65, 0.75, or 0.90 in winter, the irrigation frequency was about 6, 7, 15 times, respectively and the drain rate was 9.9, 10.8, 35.3% respectively. The signal of stem sap flow at the beginning of irrigation starting time did not correspond to that of solar irradiance when the irrigation volume per event was set to 50 or 75 mL, compared to that of 100 mL. In winter cultivation, the stem sap flow rate and substrate volumetric water content at the CT 0.65 treatment were very low, while they were very high at CT 0.90 was high. All the integrated data suggest that the proper range of irrigation volume per event is from 75 to 100 mL under at CT 0.9 and TDV 100 mL during the spring to summer cultivation, and the proper CT seems to be higher than 0.75 and lower than 0.90 under at 75 mL of the irrigation volume per event and TDV 70 mL during the winter cultivation. It is going to be necessary to investigate the relationship between capacitance value and substrate volumetric water content by determining the correction coefficient.

Bacterial Biocontrol of Sprouts through Ethanol and Organic Acids (새싹채소 오염세균의 에탄올과 유기산에 의한 제어)

  • Cho, Sung-Kyung;Park, Jong-Hyun
    • The Korean Journal of Food And Nutrition
    • /
    • v.25 no.1
    • /
    • pp.149-155
    • /
    • 2012
  • Although bacterial outbreaks from ready-to-eat foods such as sprouts have increased, the information on microbial biocontrol by means of sanitizers is limited. Twenty sprouts of red cabbage, baby radish, alfalfa, and broccoli each were collected from the wholesale markets in Seoul. Ethanol and organic acids including acetic acid, citric acid, and lactic acid were used to control the amount of mesophilic bacteria and Bacillus cereus. Sanitizer mixtures of ethanol and organic acids showed a remarkable reduction of viable counts and, in particular, the sanitizer mixture comprised of 20% ethanol and 1% lactic acid seemed to be best by a reduction of 7~8 log CFU/g on the sprouts after a 10 minute exposure. At the same time, the sanitizer comprised of 20% ethanol and 1% lactic acid showed the same reduction for Escherichia coli, Salmonella typhimurium, B. cereus, Staphylococcus aureus, and Enterococcus faecalis, with more effect toward the Gram-negative bacteria. Sensory evaluation by texture, browning, off-flavour, and overall acceptability seemed better just after treatment when compared to one day after treatment with the sanitizer. Therefore, the sanitizers of ethanol-organic acid might be an effective means to control the bacterial contamination of sprouts in palce of sodium hypochloric acid.

Performance Improvement of IPMC(Ionic Polymer Metal Composites) for a Flapping Actuator

  • Lee, Soon-Gie;Park, Hoon-Cheol;Pandita Surya D.;Yoo Young-Tai
    • International Journal of Control, Automation, and Systems
    • /
    • v.4 no.6
    • /
    • pp.748-755
    • /
    • 2006
  • In this paper, a trade-off design and fabrication of IPMC(Ionic Polymer Metal Composites) as an actuator for a flapping device have been described. Experiments for the internal solvent loss of IPMCs have been conducted for various combinations of cation and solvent in order to find out the best combination of cation and solvent for minimal solvent loss and higher actuation force. From the experiments, it was found that IPMCs with heavy water as their solvent could operate longer. Relations between length/thickness and tip force of IPMCs were also quantitatively identified for the actuator design from the tip force measurement of 200, 400, 640, and $800{\mu}m$ thick IPMCs. All IPMCs thicker than $200{\mu}m$ were processed by casting $Nafion^{TM}$ solution. The shorter and thicker IPMCs tended to generate higher actuation force but lower actuation displacement. To improve surface conductivity and to minimize solvent evaporation due to electrically heated electrodes, gold was sputtered on both surfaces of the cast IPMCs by the Physical Vapor Deposition(PVD) process. For amplification of a short IPMC's small actuation displacement to a large flapping motion, a rack-and-pinion type hinge was used in the flapping device. An insect wing was attached to the IPMC flapping mechanism for its flapping test. In this test, the wing flapping device using the $800{\mu}m$ thick IPMC. could create around $10^{\circ}{\sim}85^{\circ}$ flapping angles and $0.5{\sim}15Hz$ flapping frequencies by applying $3{\sim|}4V$.

Transmission Rate-Based Overhead Monitoring for Multimedia Streaming Optimization in Wireless Networks (무선 네트워크상에서 멀티미디어 스트리밍 최적화를 위한 전송율 기반의 오버헤드 모니터링)

  • Lee, Chong-Deuk
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.3
    • /
    • pp.358-366
    • /
    • 2010
  • In the wireless network the congestion and delay occurs mainly when there are too many packets for the network to process or the sender transmits more packets than the receiver can accept. The congestion and delay is the reason of packet loss which degrades the performance of multimedia streaming. This paper proposes a novel transmission rate monitoring-based optimization mechanism to optimize packet loss and to improve QoS. The proposed scheme is based on the trade-off relationship between transmission rate monitoring and overhead monitoring. For this purpose this paper processes a source rate control-based optimization which optimizes congestion and delay. Performance evaluated RED, TFRC, and the proposed mechanism. The simulation results show that the proposed mechanism is more efficient than REC(Random Early Detection) mechanism and TFRC(TCP-friendly Rate Control) mechanism in packet loss rate, throughput rate, and average response rate.

Multi-level Consistency Control Techniques in P2P Multiplayer Game Architectures with Primary Copy (기본 사본을 갖는 P2P 멀티플레이어 게임 구조의 수준별 일관성 제어 기법)

  • Kim, Jin-Hwan
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.4
    • /
    • pp.135-143
    • /
    • 2015
  • A Multiplayer Online Game(MOG) is a game capable of supporting hundreds or thousands of players and is mostly played using the Internet. P2P(peer-to-peer) architectures for MOGs can potentially achieve high scalability, low cost, and good performance. The basic idea of many P2P-based games is to distribute the game state among peers and along with it processing, network, and storage tasks. In a primary-copy based replication scheme where any update to the object has to be first performed on the primary copy, this means distributing primary copies of objects among peers. Most multiplayer games use a primary-copy model in order to provide strong consistency control over an object. Games consist of various types of actions that have different levels of sensitivity and can be categorized according to their consistency requirements. With the appropriate consistency level of each action type within a game, this paper allows developers to choose the right trade-off between performance and consistency. The performance for P2P game architecture with the primary-copy model is evaluated through simulation experiments and analysis.

A Novel Method for Calculating the Stroke of LPMSM for Driving Linear Compressor Using High Pass Filter (고역필터를 사용한 선형압축기 구동용 LPMSM의 새로운 스트로크 계산 기법)

  • Ahn, Jung-Ryol;Lee, Hong-Hee;Kim, Heung-Gun;Nho, Eui-Cheol;Chun, Tae-Won
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.1
    • /
    • pp.7-13
    • /
    • 2006
  • Linear compressors with a free piston driven by a linear motor are widely attention in the cooling apparatus such as refrigerator due to the high efficiency The stroke of piston in the linear compressor driven by LPMSM (Linear Permanent-Magnet Synchronous Motor) can be obtained from Integrating the input voltage and current of LPMSM, but it may be diverged due to dc components in the voltage and current. The strategy to prevent the divergence of stroke using both the high-pass filter and do offset compensation was suggested. The equations for the magnitude and phase of the stroke and also dc offset including the stroke are derived as a function of the cut-off frequency of HPF. The accurate stroke of a piston can be calculated by compensating for dc offset. The performance of the newly developed stroke calculation scheme has been verified by experimentally on a linear compressor drive system, where the control was implemented by a 16-bit DSP.

Self Tuning PI Temperature Control for BIPV Cooling System (BIPV 냉각시스템을 위한 자기동조 PI 온도제어)

  • Kim, Do-Yeon;Ko, Jae-Sub;Choi, Jung-Sik;Jung, Byung-Jin;Baek, Jung-Woo;Chung, Dong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1080_1081
    • /
    • 2009
  • This paper proposes a cooling system using self tuning PI controller for improving the output of BIPV module. The temperature characteristics in regard to improving the output of BIPV system has rarely been studied up to now but some researchers only presented the method using a ventilator. The cooling system efficiency of BIPV module applied to a ventilator mainly depends on the weather such as wind and insolation etc. Because the cooling system of BIPV module using a ventilator is so sensitive, that is being set off by wind speed at all time but is unable to operate in the nominal operating cell temperature(NOCT) which is able to make the maximum output. The paper proposes the cooling system using thermoelectron by self tuning PI controller so as to solve such problems. The thermoelectron control of self tuning PI controller can be controlled independently in the outside environment because that is performed by micro-controller. The temperature control of thermoelectron, also, can be operated around NOCT through algorism of the temperature control. Therefore, outputs of the whole system increase and the efficiency rises. The paper demonstrates the validity of proposed method by comparing the data obtained through a experiment of the cooling method of BIPV using a ventilator and proposed thermoelectron

  • PDF

Dynamic Simulation of the Water-steam System in Once-through Boilers - Sub-critical Power Boiler Case - (관류보일러 물-증기 계통의 동적 시뮬레이션 - 아임계 동력보일러 사례 -)

  • Kim, Seongil;Choi, Sangmin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.5
    • /
    • pp.353-363
    • /
    • 2017
  • The dynamics of a water-steam system in a once-through boiler was simulated based on the physics-based modeling approach, representing the system in response to large load change or scale disturbance simulations. The modeling considered the mass, energy conservation, and momentum equation in the water pipe and the focus was limited to the sub-critical pressure region. An evaporator tube modeling was validated against the reference data. A simplified boiler system consisting of economizer, evaporator, and superheater was constructed to match a 500 MW power boiler. The dynamic response of the system following a disturbance was discussed along with the quantitative response characteristics. The dynamic response of the boiler system was further evaluated by checking the case of an off-design point operation of the feedwater-to-fuel supply ratio. The results re-emphasized the significance of controlling the feedwater-to-fuel supply ratio and additional design requirements of the water-steam separator and spray attemperator.

Implementation of Leakage Monitoring System Using ZigBee (ZigBee를 적용한 누전상태 모니터링시스템 구현)

  • Ju, Jae-han;Na, Seung-kwon
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.1
    • /
    • pp.107-112
    • /
    • 2017
  • In recent years, electric shock accidents due to electric leakage currents of household appliances such as computers, TVs, refrigerators, and LED lights are continuously occurring in homes and industrial buildings. And it is not easy to check the leakage current of each household appliances connected in parallel at the rear end of the module. In addition, the leakage current flowing through the path of the normal current other than the existing current leakage circuit breakers are installed in the distribution box, only the function to cut off the power when the leakage. Therefore, there are various disasters such as electric shock and fire caused by short circuit of household appliances, and the risk of such leakage current is seriously presented. In this paper, we propose a method to implement a leakage monitoring system that can be monitored at all times using Zigbee communication based on IEEE 80215.4, which has advantages in low power and low cost among short range wireless communication systems.