• Title/Summary/Keyword: Oil exchange

Search Result 174, Processing Time 0.027 seconds

Cooling Performance Characteristics of High-Performance Heat Pump with VI Cycle Using Re-Cooler (재냉기를 이용한 고성능 VI(Vapor Injection)사이클 열펌프의 냉방 성능특성에 관한 연구)

  • Lee, Jin-Kook;Choi, Kwang-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.6
    • /
    • pp.592-598
    • /
    • 2015
  • In this study, we experimentally investigate the performance characteristics of a high-performance summer-cooling heat pump for an R410A by applying an air-cooled-type vapor-injection (VI) cycle. The devices used for the experiment consist of a VI compressor, condenser, oil separator, plate-type heat-exchanger, economizer, evaporator, and re-cooler. The experimental conditions employed for the cooling performance were divided into three cycles. First, in Cycle A, we apply a VI cycle and with no heat exchange between the evaporator outlet refrigerant and the VI cycle suction refrigerant in the re-cooler. For Cycle B, there is heat exchange, and for Cycle C, there is neither a VI cycle nor heat exchange between the evaporator outlet refrigerant and the VI cycle suction refrigerant. From the analysis results, we observe that the performance was highest in the VI cycle with heat exchange between the evaporator outlet refrigerant and the VI cycle suction refrigerant (Cycle B), while it was lowest in Cycle C without application of the VI cycle. Moreover, the cooling coefficient of Performance ($COP_C$) averaged 3.5 in Cycle B, which was 8.6% higher than the corresponding value in Cycle A, and 33% higher than that in Cycle C.

Selective Nitrate Removal Performance Analysis of Ion Exchange Resin in Shipboard Waste Washwater by Air Pollution Prevention Facility (선박용 대기오염장치 폐세정수 내 질산염의 선택적 제거를 위한 이온교환수지 공정 성능 평가)

  • Kim, Bong-Chul;Yeo, In-Seol;Park, Chan-Gyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.4
    • /
    • pp.399-404
    • /
    • 2021
  • From 1 January 2020, the limit for Sulphur in fuel oil used on board ships operating outside designated emission control areas will be reduced to 0.5 %. This regulation by international maritime organization (IMO) is able to significantly reduce the amount of Sulphur oxides (SOx) discharging from ships and should have environmental advantages and health for all over the world. To meet the regulation, in these days, wet scrubber system is being actively developed. However, this process leads to make washing wastewater. In this study, we evaluated ion exchange resin system in accordance with scrubber wastewater discharge regulation by IMO. Theoretical wastewater used as feed solution of lab scale water treatment systems. The results revealed that nitrate ion was removed selectively in spite of high TDS wash wastewater solution depending on ion exchange resin property. Moreover, it was possible to improve efficiency of the system by optimizing operating conditions.

Esterification of High Concentration Free Fatty Acid in Rice Bran Oil (미강유 중 고농도 자유지방산의 에스테르화)

  • Shin, Yong-Seop
    • Journal of Environmental Science International
    • /
    • v.17 no.2
    • /
    • pp.211-224
    • /
    • 2008
  • Characteristics of the esterification reaction between free fatty acid in rice bran oil and methanol was investigated in the presence of catalysts, such as PTS(p-toluene sulfonic acid), Amberlyst 15 dry and SCX(silica gel based strong cation exchange resin). While reaction temperature was kept constant at $65^{\circ}C$, initial feed content of free fatty acid was varied from 100% to 1% by addition of pure free fatty acid which was previously made from rice bran oil. Also, the effect of mole ratio of methanol to fatty acid on the final conversion was examined. When esterification of pure free fatty acid was catalyzed by several acids, final conversions were increased in order of Amberlyst 15 dry, SCX and PTS. Using PTS catalyst, initially the reaction proceeded in homogeneous 2nd oder reaction mechanism. However, phase of reaction mixture changed from homogeneous to heterogeneous along the reaction time and then reaction rate was retarded by mass transfer resistance of methanol. Final conversion of free fatty acid in reaction mixture was depended on initial feed content of free fatty acid, and had maximum value at 30% of initial feed free fatty acid content for all kinds of catalysts used. And the final conversion was increased with mole ratio of methanol by the improvement of reaction rate. When initial feed free fatty acid content below 10% and the reaction was catalyzed by PTS, concentration of free fatty acid in reaction mixture was increased in the middle of reaction time by hydrolysis of triglyceride in reaction mixture. Also, if silica gel was added into the reaction mixture which had initial feed free fatty acid content below 50%, final conversion was increased by the adsorption of moisture produced. The SCX catalyst made the esterification reaction of free fatty acid to progress like in case of PTS catalyst. However, when initial feed free fatty acid content below 10%, concentration of free fatty acid in. reaction mixture was decreased monotonically and not increased in the middle of reaction time on the contrary to the case of PTS. Thus, SCX catalyst accomplished more high value of final conversion than PTS catalyst for the initial feed fatty acid content range from 50% to 5% In case of initial feed free fatty acid content of 1% and mole ratio of methanol was 2, concentration of free fatty acid in reaction mixture increased over the initial feed free fatty acid content for all kind of catalysts used. Although SCX catalyst was added into reaction mixture which had 1% of initial feed fatty acid content, final conversion was hardly raised by mole ratio of methanol.

Purification and Characterization of Lipase from Acinetobacter sp. B2 Isolated from Oil­contaminated Soil (유류오염지역에서 분리한 Acinetobacter sp. B2로부터의 Lipase 정제 및 특성)

  • Son Seung Hwa;Park Kyeong Ryang
    • Korean Journal of Microbiology
    • /
    • v.40 no.4
    • /
    • pp.320-327
    • /
    • 2004
  • Three hundreds thirty two bacterial colonies which were able to degrade crude oil were isolated from soil sam­ples that were contaminated with oil in Daejeon area. Among them, one bacterial strain was selected for this study based on its higher oil degrading ability, and this selected bacterial strain was identified as Acinetobactor sp. B2 through physiological-biochemical tests and analysis of its 16S rRNA sequence. Acinetobactor sp. B2 was able to utilize various carbohydrates but did not utilize trehalose and mannitol as a sole carbon source. Acinetobactor sp. B2 showed a weak resistance to antibiotics such as kanamycin, streptomycin, tetracycline and spectinomycin, but showed a high resistance up to mg/ml unit to heavy metals such as Ba, Li, Mn, AI, Cr and Pb. The optimal growth temperature of Acinetobactor sp. B2 was $30^{\circ}C.$ The lipase produced by Acinetobactor sp. B2 was purified by ammonium sulfate precipitation, DEAE-Toyopearl 650M ion exchange chromatography and Sephadex gel filtration chromatography. Its molecular mass was about 60 kDa and condition for the optimal activity was observed at $40^{\circ}C$ and pH 10, respectively. The activation energy of lipase for the hydrolysis of p­nitrophenyl palmitate was 2.7 kcal/mol in the temperature range of 4 to $37^{\circ}C,$ and the enzyme was unstable at the temperature higher than $60^{\circ}C.$ The Michaelis constant $(K_m)\;and\;V_{max}$ for p-nitrophenyl palmitate were 21.8 uM and $270.3\;{\mu}M\;min^{-1}mg^{-1},$ respectively. This enzyme was strongly inhibited by 10 mM $Cd^{2+},\;Co^{2+},\;Fe^{2+},\;Hg^{2+},$ EDTA and 2-Mercaptoethalol.

HEAT PIPE TYPE EXHAUST HEAT RECOVERY SYSTEM FOR HOT AIR HEATER

  • Kang, G.C.;Kim, Y.J.;Ryou, Y.S.;Rhee, K.J.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11c
    • /
    • pp.654-661
    • /
    • 2000
  • Area of greenhouse increases rapidly up to 45,265ha by the year of 1998 in Korea. Hot air heater with light oil combustion is the most common heater for greenhouse heating in the winter season. However, exhaust gas heat discharged to atmosphere through chimney reaches up to 10~20% of total heat of the oil combusted in the furnace. In order to recapture the heat of this exhaust gas and to recycle for greenhouse heating, the heat pipe type exhaust heat recovery system was manufactured and tested in this experiment. The exhaust heat recovery system was made for space heating in the greenhouse. The system consisted of a heat exchanger made of heat pipes, ${\emptyset}15.88{\times}600mm$ located in the rectangular box of $600{\times}550{\times}330mm$, a blower and air ducts. The rectangular box was divided by two compartments where hot chamber exposed to exhaust gas in which heat pipes could pick up the heat of exhaust gas, and by evaporation of the heat transfer medium in the pipes it carries the heat to the cold compartment, then the blower moves the heat to greenhouse. The number of heat pipe was 60, calculated considering the heat exchange amount between flue gas and heat transfer capacity of heat pipe. The working fluid of heat pipe was acetone because acetone is known for its excellent heat transfer capacity. The system was attached to the exhaust gas path. According to the performance test it could recover 53,809 to 74,613kJ/hr depending on the inlet air temperature of 12 to $-12^{circ}C$ respectively when air flow rate $1,100\textrm{m}^3/hr$. The exhaust gas temperature left the heat exchanger dropped to $100^{circ}C$ from $270^{circ}C$ by the heat exchange between the air and the flue gas, the temperature difference was collected by the air and the warm air temperature was about $60^{circ}C$ at the air flow rate of $1,100\textrm{m}^3/hr$. This heat pipe type exhaust heat recovery system can reduce fuel cost by 10% annually according to the economic analysis.

  • PDF

A Study on the Optimal Service Level of Exclusive Container Terminals (컨테이너 전용부두의 최적 서비스 수준에 관한 연구)

  • Park, Sang-Kook
    • Journal of Korea Port Economic Association
    • /
    • v.32 no.2
    • /
    • pp.137-156
    • /
    • 2016
  • This study analyzes the optimal service levels of exclusive container terminals in terms of the optimal berth occupancy rate and the ships' waiting ratios, based on the number of berths. We develop a simulation model using berth throughput data from pier P, Busan New Port, a representative port in Korea, and apply the simulation results to different numbers of berths. In addition to the above results, we analyze the financial data and costs of delayed ships and delayed cargoes for the past three years from the viewpoints of the terminal operation company (TOC), shipping companies, and shippers to identify the optimal service level for berth occupancy rates that generate the highest net profit. The results show that the optimal levels in the container terminal are a 63.4% berth occupancy rate and 10.6% ship waiting ratio in berth 4,66.0% and 9.6% in berth 5, and 69.0% and 8.5% in berth 6. However, the results of the 2013 study by the Ministry of Maritime Affairs and Fisheries showed significantly different optimal service levels: a 57.1% berth occupancy rate and 7.4% ship waiting ratio in berth 4; 63.4% and 6.6% in berth 5; and 66.6% and 5.6% in berth 6. This suggests that optimal service level could change depending on when the analysis is performed. In other words, factors affecting the optimal service levels include exchange rates, revenue, cost per TEU, inventory cost per TEU, and the oil price. Thus, optimal service levels can never be fixed. Therefore, the optimal service levels for container terminals need to be able to change relatively quickly, depending on factors such as fluctuations in the economy, the oil price, and exchange rates.

EXHAUST GAS HEAT RECOVERY SYSTEM FOR PLANT BED HEATING IN GREENHOUSE PRODUCTION

  • Kim, Y.J.;Ryou, Y.S.;Rhee, K.J.;Kang, G.C.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11c
    • /
    • pp.639-646
    • /
    • 2000
  • Hot air heater with light oil combustion is the most common heater for greenhouse heating in the winter season in Korea. However, since the heat efficiency of the heater is about 80%, considerable unused heat in the form of exhaust gas heat discharges to atmosphere. In order to capture this exhaust gas heat a heat recovery system for plant bed heating in the greenhouse was built and tested in the hot air heating system of greenhouse. The system consists of a heat exchanger made of copper pipes, ${\phi}\;12.7{\times}0.7t$ located inside the rectangular column of $330{\times}330{\times}900mm$, a water circulation pump, circulation plastic pipe and a water tame The total heat exchanger area is $1.5m^2$, calculated considering the heat exchange amount between flue gas and water circulated in the copper pipes. The system was attached to the exhaust gas path. The heat recovery system was designed as to even recapture the latent heat of flue gas when exposing to low temperature water in the heat exchanger. According to performance test it can recover 45,200 to 51,000kJ/hr depending on the water circulation rates of 330 to $690{\ell}$/hr from the waste heat discharged. The exhaust gas temperature left from the heat exchanger dropped to $100^{circ}C$ from $270^{circ}C$ by the heat exchange between the water and the flue gas, while water gained the difference and temperature increased to $38^{circ}C$ from $21^{circ}C$ at the water flow rate of $690{\ell}$/hr. And, the condensed water amount varies from 16 to $43m{\ell}$ at the same water circulation rates. This condensing heat recovery system can reduce boiler fuel consumption amount in a day by 34% according to the feasibility study of the actual mimitomato greenhouse. No combustion load was observed in the hot air heater.

  • PDF

A Study on the Characteristics of Heating Performance of High-Performance Heat Pump with VI cycle using Re-Heater (재열기를 사용한 고성능 VI 사이클 열펌프의 난방 성능 특성에 관한 연구)

  • Lee, Jin-Kook;Choi, Kwang-Hwan
    • Journal of Power System Engineering
    • /
    • v.19 no.4
    • /
    • pp.69-75
    • /
    • 2015
  • In this study, the characteristics of heating performance of a high-performance air-cooled heat pump with vapor-injection(VI) cycle using re-heater was investigated experimentally. Devices used in the experiment is consist of a VI compressor, condenser, oil separator, refrigerant (economizer outlet refrigerant) re-heater, economizer, evaporator. And R410A was used as a working fluid. The experiment was conducted with two cycles(cycles A and B) for investigating heating performance. In case of cycle B, heat exchange was conducted by re-heater between outlet refrigerant of compressor and suction refrigerant of the VI system(Fig.1, re-heater). But the re-heater was not used in case of cycle A. As a result of this experiment, discharge temperature of refrigerator in compressor was shown higher value, when the cycle B was conducted, because of the heat exchange between suction refrigerant of VI cycle and outlet refrigerant of compressor in the re-heater than cycle A that was not use re-heater. it means that liquid hammer and the decrement of heating performance can be decreased by using re-heater. Also, Heating coefficient of performance(COPh) was shown about 2.98 in Cycle B which was 4% higher than Cycle A and from these results, It was confirmed that the improvement of the heating performance of heat pump with VI cycle can be achieved by applying re-heater.

Characteristics of Petroleum Geology of the Marine Basins in North Korea and Mutual Cooperative Plans for MT (Marine Technology) (북한 해양분지의 석유지질학적인 특징과 남북한 해양과학기술 협력 방안)

  • Huh, Sik;Yoo, Hai-Soo;Kwon, Suk-Jae;Oh, Wee-Yeong;Pae, Seong-Hwan
    • The Korean Journal of Petroleum Geology
    • /
    • v.12 no.1
    • /
    • pp.27-33
    • /
    • 2006
  • The possibility of oil reserve has been conformed because the oil has been produced by 450 barrel per day in the West Korea Bay basin of the North Korea. There is also possibility of giant oil reserve since it is geographically close to one of the biggest oil fields of Bohai Basin, China. Based on the on-going oil exploration and the present condition of investment, the areas of ongoing oil exploration are three: West Korea Bay B&C prospect explored by Swedish Taurus, the north of West Korea Bay and Anju basin explored by Canadian SOCO, and East Korea Bay explored by Australian Beach Petroleum. However, there is little or no possibility of oil reserve in the rest sea areas of three. Even though oil reserves were discovered in the some parts of land areas such as Kilju and Myungcheon, it was presumed to have no economical efficiency. Geology in West Korea Bay off the North Korea is similar to that in Bohai Bay off China. The basement consists of thick carbonate rock of the Late Proterozoic and Early Paleozoic overlain by Mesozoic ($6,000{\sim}10,000\;m$) and Cenozoic ($4,000{\sim}5,000\;m$) units. Source rocks are Jurassic black shale (3,000 m or more), Cretaceous black shale ($1,000{\sim}2,000\;m$), and pre-Mesozoic carbonates (several thousand meters). Reservoir rocks are Mesozoic-Cenozoic sandstone with high porosity and pre-Mesozoic fractured carbonate rocks. Petroleum raps are of the anticline, fault sealed, buried hill, and stratigraphic types. It absolutely needs to take up a positive attitude, the activation of ocean science and technology exchange, and the joint research and development of modern MT (Marine Technology) considering the state of establishing new international ocean order forcing on building up 200 nautical mile EEZ (exclusive economic zone) among coastal nations. Both South and North Koreas should extend the ocean jurisdiction and contiguity, and MT development dealing with the same sea areas. It is more urgent problem to find a way to have the North Korea participated in, and then to develop ocean management and ocean industry individually.

  • PDF

Forecasting Bunker Price Using System Dynamics (시스템 다이내믹스를 활용한 선박 연료유 가격 예측)

  • Choi, Jung-Suk
    • Journal of Korea Port Economic Association
    • /
    • v.33 no.1
    • /
    • pp.75-87
    • /
    • 2017
  • The purpose of this study is to utilize the system dynamics to carry out a medium and long-term forecasting analysis of the bunker price. In order to secure accurate bunker price forecast, a quantitative analysis was established based on the casual loop diagram between various variables that affects bunker price. Based on various configuration variables such as crude oil price which affects crude oil consumption & production, GDP and exchange rate which influences economic changes and freight rate which is decided by supply and demand in shipping and logistic market were used in accordance with System Dynamics to forecast bunker price and then objectivity was verified through MAPEs. Based on the result of this study, bunker price is expected to rise until 2029 compared to 2016 but it will not be near the surge sighted in 2012. This study holds value in two ways. First, it supports shipping companies to efficiently manage its fleet, offering comprehensive bunker price risk management by presenting structural relationship between various variables affecting bunker price. Second, rational result derived from bunker price forecast by utilizing dynamic casual loop between various variables.