• 제목/요약/키워드: Oil detector

검색결과 91건 처리시간 0.024초

기계 상태진단을 위한 인-라인형 오일 모니터링 스마트 센서 (In-line Smart Oil Sensor for Machine Condition Monitoring)

  • 공호성;오씨아빅터;한흥구;류보브마르코바
    • Tribology and Lubricants
    • /
    • 제24권3호
    • /
    • pp.111-121
    • /
    • 2008
  • An integrated in-line oil monitoring detector assigned for continuous in situ monitoring multiple parameters of oil performance for predicting economically optimal oil change intervals and equipment condition control is presented in this study. The detector estimates oil deterioration based on the information about chemical degradation, total contamination, water content of oil and oil temperature. The oil oxidation is estimated by "chromatic ratio", total contamination is measured by the changes in optical intensity of oil in three optical wavebands ("Red", "Green" and "Blue") and water content is evaluated as Relative Saturation of oil by water. The detector is able to monitor oils with low light absorption (hydraulic, transformer, turbine, compressor and etc. oils) as well as oils with rather high light absorption in visible waveband (diesel and etc. oils). In a case study that the detector is applied to a diesel engine oil, it is found that the detector provides good results on oil chemical degradation as well as soot concentration.

용량센서를 적용한 오일증기검출기 거동 해석 (Analysis of Oil-Mist-Detector applied Capacitance Sensor)

  • 이길승;김태옥;김화영;안중환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.279-280
    • /
    • 2006
  • This paper analysised Oil-Mist-Detector applied Capacitance Sensor which protects Diesel engine & human from explosion by detecting density of oil mist distribution. Assuming that distance between oil mists is same, Capacitance sensor plates & all oil mists could be analogized to capacitors. From equivalent circuit of Oil-Mist-Detector, variation of Capacitance which is related to Oil Mist's diameter & density of oil mist distribution is obtainable.

  • PDF

디젤 엔진오일 내 Soot 함량 증가에 따른 오염도 측정에 관한 실험적 고찰 (An Experimental Study on the Measurement of Soot Contamination in a Diesel Engine Oil)

  • 공호성;조성용;윤의성;한흥구;정동윤
    • Tribology and Lubricants
    • /
    • 제19권5호
    • /
    • pp.251-258
    • /
    • 2003
  • New method and device for the on-line measurement of soot concentration in a diesel engine oil are proposed, where the measurement principle is based mainly on attenuated internal total reflection. The detector were evaluated in various ranges of contaminated oils by carbon black particles. It was found that the proposed detector could be well used to monitor the oil deterioration due to soot contamination. Operational range of the detector was found from 0 to 5 mass percentage of soot content. Test results with water and fuel dilution showed that these effects were not remarkable. However, adsorption of carbon black particles onto the measurement surface was considered to be a critical problem of the detector. Effects of particle deposition on the interface was experimentally evaluated with the oil temperature and flow turbulence and discussed throughout this work.

디젤 엔진오일 내 Soot 함량 증가에 따른 오염도 측정에 관한 실험적 고찰 (An Experimental Study on the Measurement of Soot Contamination in A Diesel Engine Oil)

  • 조성용;공호성;윤의성;한흥구;정동윤
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 제35회 춘계학술대회
    • /
    • pp.120-129
    • /
    • 2002
  • New method and device for the on-line measurement of soot concentration in a diesel engine oil are proposed, where the measurement principle is based mainly on attenuated internal total reflection. Various laboratory tests of the detector were performed mainly with carbon black particles of different contamination levels. It was found that the proposed detector could be well used to monitor oil deterioration due to soot contamination. Operational range of the detector was found from 0 to 5 mass percentage of soot content. Test results with water and fuel dilution showed that these effects were not remarkable. However, adsorption of carbon black particles to a measurement surface was considered to be a critical problem in the new detector. Effects of particle deposition onto the interface was experimentally evaluated with the oil temperature and turbulence and discussed throughout this work.

  • PDF

참기름의 휘발성 향기성분의 특성 (Characteristics of the Volatile Flavor Compounds in the Oil from Roasted Sesame Seed)

  • 하재호
    • 한국식품과학회지
    • /
    • 제29권6호
    • /
    • pp.1101-1104
    • /
    • 1997
  • 참기름의 향기성분을 dynamic headspace법으로 포집 한 다음 FID와 OD가 장착된 GC-MSD로 분석 하였다. 주요 향기성분으로는 methylpyrazine, acetic acid, 2-furan carboxaldehyde 및 2-furanmethanol 등 20종이 분리동정되었다. Sniffing test 결과 pyrazine류와 2-furan carboxaldehyde은 참기름의 좋은 향을 나타내었고 acetic acid와 2-furanmethanol은 참기름의 좋지않은 냄새로 밝혀졌다.

  • PDF

Gas Detector for Hydrogen Dissolved in Transformer Oil

  • Seo Ho-Joon;Hwang Kyu-Hyun;Rhie Dong-Hee
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권2호
    • /
    • pp.72-75
    • /
    • 2005
  • In oil-filled equipment such as transformers, partial discharge or local overheating will precede a final shutdown. Accompanied with such problems is a decomposition of insulating material into gases, which are dissolved into the transformer oil. The gases dissolved in oil can be separated with some membranes based on the differences in permeability of membranes to different gases. This paper discuss the permeability characteristics of several membranes for separation hydrogen gas in oil. With result of this paper, it may become possible to detect fault-related gases from transformer oil and predict incipient failures in the

자기탄성체 리본의 공진을 이용한 인-라인 오일 점도센서 (In-line Oil Viscosity Sensor Implementing An Elastomagnetic Ribbon Resonance)

  • 공호성;한흥구
    • Tribology and Lubricants
    • /
    • 제26권2호
    • /
    • pp.97-104
    • /
    • 2010
  • A new magnetoelastic technique of oil viscosity measurement, where the oil viscosity is estimated by frequency shift of natural oscillations of magnetoelastic ribbon, is implemented in this study. Laboratory tests of the detector prototype are performed for measurement of viscosity of base synthetic and mineral oils. It was found that measurement accuracy was better when damping factor was estimated in comparison with accuracy of frequency of damped oscillations. Thus the oil viscosity was calibrated as a function of number of pulses of the damped oscillations of magnetoelastic ribbon. Result generally showed that developed detector is promising for in line oil viscosity measurement in wide viscosity range from 10 cSt up to 600 cSt, while the viscosity measurement was relatively instable when the viscosity of test oil was over 400 cSt.

실시간 기름유출 모니터링 기술에 관한 연구 (A Study on the Real-Time Oil-Spill Monitoring Technology)

  • 염우정;홍연찬
    • 한국산학기술학회논문지
    • /
    • 제18권2호
    • /
    • pp.472-477
    • /
    • 2017
  • 기름 유출로 인한 피해는 수질환경 및 생태계를 단시간에 파괴할 뿐만 아니라 한번 오염이 되면 회복하는데 상당한 시간이 걸리고 회복이 어려우며, 지속적으로 나타난다. 때문에 해양이나 하천, 담수 등의 기름유출을 모니터링할 수 있는 오일 검출기의 필요성이 매우 높다. 오일을 검출할 수 있는 기술로는 크게 접촉식과 비접촉식으로 구분할 수 있으며, 접촉식으로는 Conductivity, Capacitance, Microwave 등이 있고 비접촉식으로는 Infrared, UV, Laser, Optic, Radar 등으로 구분할 수 있다. 수면 위에 있는 오일을 측정하기 위해서는 파고 및 너울, 빛의 산란, 온도, 염도 등 여러 가지 관측의 장애가 존재하기에 측정하고자 하는 환경에 맞는 오일 검출기를 선택하여 사용해야 한다. 본 논문에서는 접촉식 방식으로 정유회사 및 유화회사, 발전소 등의 오일 관련 업종에서 사용할 수 있는 오일 검출기를 구현하였다. 장비의 구성은 수면 위에 띄워 놓는 센서 모듈과 센서 모듈에서 들어오는 신호를 가공하여 표시하는 제어기로 구분하며, 센서를 통하여 오일의 유무를 판별하고 더 나아가 오일의 양과 오일의 종류에 따른 유전율의 변화를 관측하였다.

배전용 변압기의 진단을 위한 위상 검출 장치의 개발 (Development of Phase Sensitive Detector for Diagnosis of Distribution Transformers)

  • 김영춘;최도혁;윤용한;민경래;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.547-549
    • /
    • 2000
  • This paper develops phase sensitive detector for diagnosis of distribution transformers. And to detect the $tan{\delta}$ more effectively, this paper used phase sensitive detector. The sensor in oil which could be placed inside of the distribution transformer can measures the $tan{\delta}$ in oil. This could be the important factor and information, and it could be used for the basic information for a precise diagnosis. Establishment of the proposed system helps to build the confidence in monitoring of the oil-filled transformers.

  • PDF