• Title/Summary/Keyword: Oil Supply

Search Result 468, Processing Time 0.024 seconds

The Ejector Design and Test for 5kW MCFC System (5kW 용융탄산염 연료전지(MCFC) 이젝터 설계 및 시험)

  • Kim, Beom-Joo;Kim, Do-Hyeong;Lee, Jung-Hyun;Lee, Sung-Yoon;Kim, Jin-Yoel;Kang, Seung-Won;Lim, Hee-Chun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.1
    • /
    • pp.31-37
    • /
    • 2009
  • An ejector is a machine utilized for mixing fluid, maintaining a vacuum, and transporting fluid. The Ejector enhances system efficiency, are easily operated, have a mechnically simple structure, and do not require a power supply. Because of these advantages, the ejector has been applied to a variety of industrial fields such as refrigerators, power plants and oil plants. In this work, an ejector was used to safely recycle anode tail gas in a 5 kW Molten Carbonate Fuel Cell system at KEPRI(Korea Electric Power Research Institute). In this system, the ejector is placed at mixing point between the anode tail gas and the cathode tail gas or the fresh air. Commercial ejectors are not designed for the actual operating conditions for our fuel cell system. A new ejector was therefore designed for use beyond conventional operating limits. In this study, the entrainment ratio is measured according to the diametrical ratio of nozzle to throat in the designed ejector. This helps to define important criteria of ejectors for MCFC recycling.

A Study on the Effective Utilization Plan through Field Investigation and Analysis with Power Transformers in Domestic Areas

  • Shin, Heung-Sik;Lee, Jae-Cheon;Bai, Seok-Myung;Kim, Seon-Gu;Kim, Jin-Tae;Kim, Gi-Hyeon;Jeong, Jong-Wook;Bang, Seon-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.4
    • /
    • pp.88-95
    • /
    • 2007
  • Korea is highly dependent on foreign countries for energy while at the same time having a high energy-consumption industrial structure. Therefore, logical improvements in energy use efficiency and nationwide energy saving are becoming more and more important in coping with the worldwidehigh oil prices and environmental issues such as listed in the Kyoto Protocol to the United Nations Framework Convention on Climate Change. Consequently, a study was conducted on the average annual load factor in domestic areas to set a reasonable and reliable technology standard plan for high-efficiency transformers. The average annual load factor in Korea was discovered to be 18.4[%] classified by industry. This factor is expected to be used in arranging a domestic standard for a minimum efficiency system for transformers, and in reviewing and supplementing the standard transformers plan for the High Energy-Efficiency Appliance Certification. The expected effect from the establishment of the technology standards plan for highly efficient transformers is the expansion of the manufacturing and distribution of highly efficient transformers that are suitable for domestic use. These will lead to electricity cost savings for users, strengthening the related industries' market competitive powers and the effective reduction of greenhouse gases on a national level by drastically reducing loss from transformers, which accounts for a large portion of the total electric supply losses.

A Study on Berth Allocation for Navy Surface Vessels Considering Precedence Relationships among Services (서비스 전후 우선순위를 고려한 해군함정의 선석 할당에 관한 연구)

  • Jung, Whan-Sik;Kim, Jae-Hee;Kim, Sheung-Kwon
    • Journal of Navigation and Port Research
    • /
    • v.28 no.1
    • /
    • pp.83-90
    • /
    • 2004
  • Navy surface vessels require pier services such as emergency repair, oil supply, arm loading / unloading, craning, standby readiness, normal repair, gun arrangement, ammunition loading, and food loading during the period in port. The purpose of this study is to establish efficient berth allocation plan for navy surface vessels in home port under the limited resources of piers and equipments. This study suggests Mixed Integer Programming model for berth allocation problem, considering precedence relationships among services. For an effective analysis, the model is implemented by ILOG OPL(Optimization Programming Language) Studio 3.1 and ILOG CPLEX 7.0. The results of the model show reduction of berth shifts and increasement of service benefits.

An Experimental Study on the Spray and Lean Combustion Characteristics of Bio-enthanol-Gasoline Blended Fuel of GDI (직접분사식 바이오에탄올-가솔린 혼합연료의 분무 및 희박연소 특성에 관한 실험적 연구)

  • Park, Gi-Young;Kang, Seok-Ho;Kim, In-Gu;Lim, Cheol-Soo;Kim, Jae-Man;Cho, Yong-Seok;Lee, Seong-Wock
    • Journal of ILASS-Korea
    • /
    • v.19 no.3
    • /
    • pp.115-122
    • /
    • 2014
  • As a demand for an automobile increases, air pollution and a problem of the energy resources come to the fore in the world. Consequently, governments of every country established ordinances for green-house gas reduction and improvement of air pollution problem. Especially, as international oil price increases, engine using clean energy are being developed competitively with alternative transportation energy sources development policy as the center. Bio ethanol, one of the renewable energy produced from biomass, gained spotlight for transportation energy sources. Studies are in progress to improve fuel supply methods and combustion methods which are key features, one of the engine technologies. DI(Direct Injection), which can reduce fuel consumption rate by injecting fuel directly into the cylinder, is being studied for Green-house gas reduction and fuel economy enhancement at SI(Spark Ignition). GDI(Galoine Direct Injection) has an advantage to meet the regulations for fuel efficiency and $CO_2$ emissions. However it produces increased number of ultrafine particles, that yet received attention in the existing port-injection system, and NOX. As fuel is injected into the cylinder with high-pressure, a proper injection strategy is required by characteristics of a fuel. Especially, when alcohol type fuel is considered. In this study, we tried to get a base data bio-ethanol mixture in GDI, and combustion for optimization. We set fuel mixture rate and fuel injection pressure as parameters and took a picture with a high speed camera after gasoline-ethanol mixture fuel was injected into a constant volume combustion chamber. We figured out spraying characteristic according to parameters. Also, we determine combustion characteristics by measuring emissions and analyzing combustion.

Analysis of Annual Emission Trends of Air Pollutants by Region (권역별 대기오염물질의 연도별 배출 특성 분석)

  • Lim, Jun Hyun;Kwak, Kyeong Kyu;Kim, Jeong;Jang, Young Kee
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.1
    • /
    • pp.76-86
    • /
    • 2018
  • Using the CAPSS emissions data, we analysed changes and reasons in the annual air pollutant emission trends from 1999 to 2014. The CO emissions in the metropolitan area decreased steadily since 2001, when the latest model year of automobiles and high efficiency fuel were applied. However, other regions have not changed significantly in annual emissions. $NO_x$ emissions continued to increase since 2003, and unchanged after the decline in 2007. $SO_x$ emissions are steadily declining due to the supply of low sulfur oil. The $PM_{10}$ and $PM_{2.5}$ emissions were repeatedly affected by the influence of motor vehicles activities in the metropolitan area. In Gangwon and Chungcheong Provinces, emissions are increasing according to the use of coal in the manufacturing sector. And VOC and $NH_3$ emissions are increasing steadily every year. The major CO emission sources was automobiles in the metropolitan area. However, agricultural residue burning was the biggest CO sources in the Chungchong, Honam and Yeongnam Provinces. The major sources of $NO_x$ emissions differ from region to region. In the Metropolitan area, Honam and Yeongnam region, the truck was the largest emitter of $NO_x$. However, the cement kiln was the largest producer of $NO_x$ in Gangwon region, and the power plant is the largest emitter in Chungcheong Provinces.

Development of Heating and Cooling System with Heat Pump for Nutrient Solution Bed In Greenhouse (열펌프를 이용한 양액베드 냉난방시스템 개발)

  • Kang, Geum-Chun;Kim, Yeong-Jung;Yu, Yeong-Seon;Baek, Lee
    • Journal of Biosystems Engineering
    • /
    • v.27 no.6
    • /
    • pp.565-572
    • /
    • 2002
  • In order to control the root-zone temperature of greenhouse crops in the hydroponics at hot and cold season, heat pump system for cooling and heating was built and tested in this work. The system was air-to-water type and vapour compression type. The heating and cooling mode was selected by the four way valve. Capacity of the compressor was 3.75㎾ and heat transfer area of the evaporator and the condenser were 3.05㎡ and 0.6㎡, respectively. According to the performance test, it could supply heat of 42,360 to 64,372kJ/h depending on the water circulation rate of 600 to 1,500ℓ/h, respectively, when indoor air temperature was 10∼20$\^{C}$. COP of heat pump system was 3.0 to 4.0 in the heating mode. But, COP of the cooling mode was 1.3 to 2.1 at indoor temperature of 20∼35$\^{C}$. The feasibility test in the greenhouse the developed heating and cooling system was installed, showed that the heating cost of the developed system was only about 13% of that of the conventional heating system. The heating cost of the developed system was 367won/day(electric consumption 9.7㎾h/day), while that of the conventional system was 2,803won/day(oil consumption 7.7ℓ/day) at the same heating mode.

An Experimental Study on the Clutch Type Water Pump of Diesel Passenger Vehicle for Reducing Fuel Consumption and CO2 Emission (연비 개선 및 CO2 저감을 위한 승용디젤 차량의 클러치타입 워터펌프 적용에 따른 실험적 연구)

  • Jeong, Soo-Jin;Park, Jung-Kwon;Oh, Chang-Boke;Cho, Yong-Seok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.2
    • /
    • pp.123-134
    • /
    • 2012
  • A typical cooling system of an engine relies on a water pump that circulates the coolant through the system. The pump is typically driven by the crankshaft through a mechanical link with engine starting. In order to reduce the friction and warm-up time of an engine, the clutch-type water pump (CWP) was applied in 2.0 liter diesel vehicle. The clutch-type water pump can force cooling water to supply into an engine by the operation of an electromagnetic clutch equipped as the inner part of pump system. The onset of CWP is decided by temperature of cooling water and engine oil. And, the control logic for an optimal operation of the clutch-type water pump was developed and applied in engine and vehicle tests. In this study, the warm-up time was measured with the conventional water pump and clutch-type water pump in engine tests. And the emission and the fuel consumption were evaluated under NEDC mode in vehicle tests. Also, tests were carried out for the various temperature conditions starting the operation of CWP. From the results of the study, the application of CWP can improve the fuel consumption and $CO_2$ reduction by about 3%.

Comparative Analyses of Korean Energy Balance Tables from KEEI and IEA (in 2009) (한국과 IEA 에너지밸런스 표의 비교 분석연구 (2009년도를 중심으로))

  • Sohn, Joongchan;Kim, Suduk
    • Environmental and Resource Economics Review
    • /
    • v.24 no.1
    • /
    • pp.109-139
    • /
    • 2015
  • Referring to many previous research on the statistical differences in the figures of energy balance table between that of KEEI and IEA, a study is conducted to provide with a framework for proper comparison, followed by the actual calculation of the differences. Major differences are found for energy oil with its size of over 32% differences in primary energy supply and in energy transformation sectors. In final energy consumption sector, naptha consumption for petro-chemical industry shows 14.58% differences. Overall final energy consumption figure of KEEI after its adjustment to net calorific value as is the case of that of IEA is 3.58% larger than that of IEA. Considering the fact that energy balance table provides the basic information for the understanding of energy sector, further studies seem to be necessary for proper adjustment of current status.

Integrated Assessment for Social Impacts of National Energy and Electricity Generation Sources Using Radar Chart (방사형차트를 이용한 국가 에너지 및 전력 생산원의 사회적 영향 종합평가)

  • 김태운;김성호;문기환;하재주;김홍채;장순홍
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2004.05a
    • /
    • pp.341-346
    • /
    • 2004
  • In the present work, for various energy and electricity generating systems to be compared in view of integrated social impacts, nuclear, coal-fired, heavy oil-fired, and LNG, and hydroelectricity systems are considered as electricity generating options. The following assessment factors are selected: economic effect, health effect, environmental effect, and benefit at the national level. As a preliminary study, these factors are represented as power generation cost, estimated mortality, Carbon Dioxide gas emission, and fuel supply stability, respectively. For integrated representation of a multi-criteria decision-making (MCDM) problem, radar charts are introduced to facilitate a comparative recognition of estimates. In the near future, based on the estimates, a MCDM methodology for both qualitative and quantitative comparison will be developed.

  • PDF

Application of District Cooling System for Deep Ocean Water by Case Study (사례 분석을 통한 해양심층수의 지역냉방시스템 적용 방안)

  • Jin, Su-Hwuy;Park, Jin-Young;Kim, Sam-Uel;Kim, Hyeon-Ju
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.179-184
    • /
    • 2011
  • The development of new energy has attracted consideration attention due to the high oil price and environmental problems. In advanced country, they have tried to carry out a long range plan for energy. We need to develop new energy for Low Carbon Green Growth in Korea. The building is 30% among ratio of energy consumption in Korea. And in the past, heating energy was high ratio for energy using at home. But recently, the demand for cooling energy keeps growing due to rising average temperature on the earth and improvement of life quality. In this situation, the energy of lake water and ocean water has studied to utilize in advanced country because of low temperature at underwater. But the study for deep water is still a lot left to do. In this study, we analyzed district cooling system and the present condition. Analyzing the deep lake water cooling system in Toronto, we found an application of district cooling system using deep ocean water. Deep lake water uses heat source for district cooling and water source for city in Toronto. So reducing the initial cost, this city had economic effect. When DLWC was applied at existing building, the heat exchanger was installed instead of cooling tower and refrigerator. And the heat exchanger used to connect main pipe with cool water on city. System using deep ocean water can be applied as a similar way to supply cool water from lake to building.

  • PDF