• Title/Summary/Keyword: Oil Field

Search Result 869, Processing Time 0.028 seconds

Oil Field Geographical Information System Based on Remote Sensing, GIS and GPS

  • Wang, Ziyu;Chen, Xiuwan
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1310-1311
    • /
    • 2003
  • Oil Field Geographical Information System (OFGIS) manages multiple spatial data, attribute data, and topographic data, which include almost every kind of ground info rmation and underground information. Subsystems managed by OFGIS include petroleum exploration subsystem (PESS), petroleum development and engineering subsystem (PDESS), petrochemical subsystem (PCSS), petroleum storage and transportation subsystem (PSTSS), petroleum sale subsystem (PSSS), etc. A basic OFGIS framework consists of oil field infrastructure coverage (OFIC), oil field specialized information coverage (OFSIC) and oil field synthesis and decision service coverage (OFSDSC). Basic function of OFGIS includes database management, geographic information management, spatial information processing and application.

  • PDF

Study on the Streaming Electrification of Insulating oil Under Electricfield (전계가 가해진 절연유의 유동대전 특성 고찰)

  • 허창수;정중일
    • Electrical & Electronic Materials
    • /
    • v.10 no.4
    • /
    • pp.334-341
    • /
    • 1997
  • Streaming electrification on insulating paper and pressboard under D.C. and A.C. electric field was investigated by using paper tubes and oil circulation apparatus. At first, flowing of static charges as measured with no electric field. As the temperature of oil increased, the measured current curve hows peak. As the velocity increased, it shows increasing exponential curve. Then, we applied A.C. and D.C. electric field on paper tube and the current from relaxation tank to earth was measured, which other factors such as temperature and velocity were varied like case of no electric field. The ions in oil carry the charges. So electric field makes asymmetry effect, and electrophoretic effect on ions in oil. We find that as the electric field intensity increased, the charges which were made by electric double layer were increased. The charge vs. velocity curve made peak point at a velocity.

  • PDF

The Study on Field Test of the New Formulated and Commercial Diesel Engine Oils (제조 디젤엔진 오일과 상업용 디젤엔진 오일의 실차시험 연구)

  • 김영운;정근우;강석춘
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.3
    • /
    • pp.51-59
    • /
    • 2001
  • A diesel engine oil formulated in KRICT and a commercial diesel engine oil (API CG-4) were tested by car and their Kinematic Viscosity, TAN, TBN, metal content, additive depletion, anti-wear property and IR analysis were analyzed. From the research, both of the tested oils had almost the same properties f3r the change of TAN and TBN, but the change of Kinematic Viscosity of formulated oil was slightly higher than that of commercial oil. The iron content in the commercial oil increased rapidly from 7000 km while that of the formulated oil was still low. These results were confirmed by the anti-wear test with a 4-ball wear test machine for the each samples. Also, for the commercial oil, the depletion factor of the Zn-DTP which was added as an anti-wear property did not change any more after 7000 km. But, that of the formulated oil changed continuously to 8000 km, which means that the ability to prevent wear of the sliding pairs exists for the formulated oil. From the analysis results of oil properties obtained by field test, it was found that the commercial oil could be used only within 7000 km, but the formulated oil could be used more than 8000 km without severe wear of the sliding parts in the diesel engine.

  • PDF

A Study on Conductivity Characteristics of the Insulating Oil for X-ray Tube Housing (X선장치용(線裝置用) 절연유(絶緣油)의 도전특성(導電特性)에 관한 연구(硏究))

  • Kim, Young-Il;Lee, Duck-Chool;Chung, Yon-Tack
    • Journal of radiological science and technology
    • /
    • v.9 no.1
    • /
    • pp.73-81
    • /
    • 1986
  • This paper carried out an experiment on the characteristics of time, temperature, electric field and the dependense of electrode materials and gap length by the conduction current of the insulating oil used for x-ray tube housing. The obtained results can be summarized as following: 1. In the x-ray tube housing insulating oil with vacuum condition, conduction current is declined more than the x-ray tube housing insultaing oil with the air, and is held stable states. 2. At the low electric field the higher temperature of the x-ray tube housing insulating oil is increased, the more conduction current. 3. The dependence of electrode material is appeared at the low electric field and the short gap length than the high and the long with Fe> Cu >Al. 4. At the I-E characteristics, the low electric field than 1000 [V/cm] is appeared Ohm's law region, and the high become saturation region. 5. At the same electric field, the longer gap length become, the more conduction current is increased, and the same applied voltage, the longer, the less conduction current is decreased, the less low than high temperature x-ray tube housing insulating oil.

  • PDF

SIMULATION OF WATER-OIL-AIR FLOWS AROUND OIL BOOMS UNDER RELATIVE MOTION (상대운동을 하는 방제판 주위 물-기름-공기 유동 모사)

  • Shin, Sangmook
    • Journal of computational fluids engineering
    • /
    • v.21 no.3
    • /
    • pp.31-38
    • /
    • 2016
  • The FDS-HCIB method is expanded to simulate water-oil-air flows around oil booms under relative motion, which is intended to increase the thickness of contained oil. The FDS scheme captures discontinuity in the density field and abrupt change of the tangential velocity across an interface without smearing. The HCIB method handles relative motions of thin oil booms with ease. To validate the developed FDS-HCIB code for water-oil-air flow around a moving body, the computed results are compared with the reported experimental results on the shape, length, and thickness of the oil slicks under towing. It is observed that the increase in pressure field between two barriers lifts the oil slick and the interfacial wave propagates and reflects as one barrier gets closer to the other barrier.

Repellency of Herb Plants and Essential Oils Against the Green Peach Aphid, Myzus persicae (허브류 식물과 정유의 복숭아혹진딧물에 대한 기피 효과)

  • 김기황;정훈채
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.25 no.1
    • /
    • pp.7-11
    • /
    • 2003
  • Repellencies of herb plants and essential oils against alate Myzus persicae were investigated in a insect cage, a screen house, and a tobacco field. Numbers of nymphs deposited by alate or apterous Myzur persicae were lower on rosemary(Rosmarinus officinalis), silver thyme (Thymus vulgaris), and lemon balm(Melissa of fcianazis). Rosemary and silver thyme show little repellency against alate Myzus persicae on a nearby tobacco plant Rosemary oil, peppermint (Mentha piperita) oil, and ginger oil showed repellency against alate Myzus persicae, but spearmint (Mentha spicata) oil and lavender oil showed little repellency in a screen house. Rosemary oil, ginger oil, peppermint oil, lavender oil, and spearmint oil showed repellency against alate Myzus persicae in a tobacco field, but there was no significant difference among oils.

Preparation and Field Test of Diesel Engine Oil (디젤엔진 오일의 제조 및 성능 평가)

  • 김영운;정근우;조원오;김종호;강석춘
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.152-160
    • /
    • 1997
  • A diesel engine oil which was formulated and a commercial diesel engine oil (API CG4) made from same base oil were tested by car and analyzed of their physical, chemical and mechanical properties. The tested oil to be analyzed were sampled from engine every 1000 km until 8000 km and determined the kinematic viscosity, TAN, TBN, metal content in oil, additive depletion, antiwear property and IR analysis. From the study, both the tested oils were almost same properties for the change of TAN and TBN, but the change of kinematic viscosity of formulated oil was slightly higher than that of commercial oil. But the concentration of metal in the formulated oil, especially iron, were increased much less during test. The iron content of the commercial oil was increase rapidly from 7000 km while the formulated oil was still low. These results were conformed by the antiwear test by 4-ball wear test machine for the samples. Also for the commercial oil, the depletion factor of the Zn-DTP which was added as an antiwear property was not change any more after 7000 km. But the formulated oil was change continuously until 8000 km, which mean that the ability of wear protection of the sliding parts exists for the formulated oil. With the results which were analyzed of the properties of oils by field test, it was found that the commercial oil could be used only within 7000 km, but the formulated oil can use more than 8000 km without severe wear of the sliding parts in the diesel engine.

  • PDF

The Four Power Plants Field Demonstration Research on Combustion Characteristic of the Bio Oil for Fuel Switching (국내 4개 중유발전소 실증실험을 통한 발전연료 대체용 바이오중유의 연소특성 연구)

  • Baek, Sehyun;Kim, Hyunhee;Park, Hoyoung;Kim, Young Joo;Kim, Tae Hyung;Ko, Sung Ho
    • Journal of the Korean Society of Combustion
    • /
    • v.20 no.1
    • /
    • pp.15-23
    • /
    • 2015
  • This paper presents the results of field demonstration for fuel switching to bio-fuel oil in 4 commercial heavy oil fired power plants. The 100% fuel switching field demonstration was successfully carried out in two tangential-firing boilers at a capacity of 75 and 100 MWe respectively without major equipment retrofit, and also 25% bio-fuel oil blending for two opposite firing boilers at a capacity of 350 and 400 MWe respectively. Despite the low density and heating value, the bio fuel was successfully replaced heavy fuel oil at the full load by only adjusting operational parameters. Incase of bio fuel oil combustion, heat absorption of radiative heat transfer section was reduced while convection section has opposite trend. In pollutants emission, a major reductionin SOx as well as 10-20% reduction in NOx were achieved by the fuels witching. On the other hand, boiler efficiency was slightly underestimated.

Emulsified Oily Wastewater Treatment by MHD Water Treatment Device (MHD 수처리방식에 의한 에멀젼오일폐수의 처리)

  • 김인수;박승조
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.17 no.4
    • /
    • pp.20-27
    • /
    • 1993
  • Emulsified oily wastewater is generally hard to treat in separating oil and water by conventional separators. In this paper the magnetohydrodynamic water treatment device was used to separate oil from emulsified oily wastewater which contained high conductivity. The emulsified oil removal rates and economic ranges of oil separation at various factors were investigated to confirm the influence of the magnetic field in MHD water treatment device according to the characteristics of emulsion brake. Experimental results proved that the oil removal rates were proportional to Lorentz force which depends on the intensity of magnetic field, conductivity and velocity of wastewater.

  • PDF