• Title/Summary/Keyword: Offset Coefficient

Search Result 93, Processing Time 0.021 seconds

Proposal and Verification of Image Sensor Non-uniformity Correction Algorithm (영상센서 픽셀 불균일 보정 알고리즘 개발 및 시험)

  • Kim, Young-Sun;Kong, Jong-Pil;Heo, Haeng-Pal;Park, Jong-Euk
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.3
    • /
    • pp.29-33
    • /
    • 2007
  • All pixels of image sensor do not react uniformly even if the light of same radiance enters into the camera. This non-uniformity comes from the sensor pixel non-uniformity and non-uniformity induced by the changing transmission of the telescope over the field. The first contribution to the non-uniformity has high spatial frequency nature and has an influence on the result and quality of the data compression. The second source of non-uniformity has low frequency nature and has no influence of the compression result. As the contribution resulting from the sensor PRNU(Photo Response Non-Uniformity) is corrected inside the camera electronics, the effect of the remaining non-uniformity to the compression result will be negligible. The non-uniformity correction result shall have big difference according to the sensor modeling and the calculation method to get correction coefficient. Usually, the sensor can be modeled with one dimensional coefficients which are a gain and a offset for each pixel. Only two measurements are necessary theoretically to get coefficients. However, these are not the optimized value over the whole illumination level. This paper proposes the algorithm to calculate the optimized non-uniformity correction coefficients over whole illumination radiance. The proposed algorithm uses several measurements and the least square method to get the optimum coefficients. The proposed algorithm is verified using the own camera electronics including sensor, electrical test equipment and optical test equipment such as the integrating sphere.

The Local Measurements of Single Phase and Boiling Heat Transfer by Confined Planar Impinging Jets (평면충돌제트에 의한 단상 및 비등 열전달의 국소적 측정)

  • Wu, Seong-Je;Shin, Chang-Hwan;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.8 s.227
    • /
    • pp.895-901
    • /
    • 2004
  • Single-phase convection and nucleate boiling heat transfer were locally investigated for confined planar water jets. The detailed distributions of the wall temperature and the convection coefficient as well as the typical boiling curves were discussed. The curve for the single-phase convection indicated the developing laminar boundary layer, accompanied by monotonic increase of the wall temperature in the stream direction. Boiling was initiated from the furthest downstream as heat flux increased. Heat transfer variation according to the streamwise location was reduced as heat flux increased enough to create the vigorous nucleate boiling. Velocity effects were considered for the confined free-surface jet. Higher velocity of the jet caused the boiling incipient to be delayed more. The transition to turbulence precipitated by the bubble-induced disturbance was obvious only for the highest velocity, which enabled the boiling incipient to start in the middle of the heated surface, rather than the furthest downstream as was the case of the moderate and low velocities. The temperature at offset line were somewhat tower than those at the centerline for single-phase convection and partial boiling, and these differences were reduced as the nucleate boiling developed. For the region prior to transition, the convection coefficient distributions were similar in both cases while the temperatures were somewhat lower in the submerged jet. For single-phase convection, transition was initiated at $x/W{\cong}2.5$ and completed soon for the submerged jet, but the onset of transition was retarded to the distance at $x/W{\cong}6$ for the fee-surface jet.

Synchronization Algorithm for Wireless LAM Using OFDM Transmission Technique (OFDM 전송기술을 이용하는 무선 LAN용 동기 알고리즘)

  • 김장욱;유기희;오창헌;조성준
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.2A
    • /
    • pp.157-165
    • /
    • 2004
  • The synchronization algorithm of IEEE 802.11a WLAN(Wireless Local Area Network) has three consecutive processes, which use a short code training symbol, a long code training symbol and a pilot symbol respectively. But in using this synchronization processes, the actual embodiment has two problems. First, the synchronization process has the complex structure using a long code training symbol and a pilot symbol. Second, since the long training symbol is only compensated with the offset correction coefficient, it can not be trusted perfectly. If the equalizer coefficient is obtained in this unstable period, the system performance is degraded. In particular, the system performance becomes worst in case of the 54 Mbps transmission system using the maximum length of data. In this paper, the new algorithm is proposed which can resolve the embodiment complexity of synchronization processes and structural defect, and also it is confirmed by simulation.

Estimation of Moisture Content in Comminuted Miscanthus based on the Intensity of Reflected Light

  • Cho, Yongjin;Lee, Dong Hoon
    • Journal of Biosystems Engineering
    • /
    • v.40 no.3
    • /
    • pp.296-304
    • /
    • 2015
  • Purpose: The balance between miscanthus production and its cost effectiveness depends greatly on its moisture content during post processing. The objective of this research was to measure the moisture content using a non-destructive and non-contact methodology for in situ applications. Methods: The moisture content of comminuted miscanthus was controlled using a closed chamber, a humidifier, a precision weigher, and a real-time monitoring software developed in this research. A CMOS sensor equipped with $50{\times}$ magnifier lens was used to capture magnified images of the conditioned materials with moisture content level from 5 to 30%. The hypothesis is that when light is incident on the comminuted particles in an inclined manner, higher moisture content results in light being reflected with a higher intensity. Results: A linear regression analysis for an initiative hypothesis based on general histogram analysis yielded insufficient correlations with low significance level (<0.31) for the determination coefficient. A significant relationship (94% confidence level) was determined at level 108 in a reverse accumulative histogram proposed based on a revised hypothesis. A linear regression model with the value at level 108 in the reverse accumulative histogram for a magnified image as the independent variable and the moisture content of comminuted miscanthus as the dependent variable was proposed as the estimation model. The calibrated linear regression model with a slope of 92.054 and an offset of 32.752 yielded 0.94 for the determination coefficient (RMSE = 0.2%). The validation test showed a significant relationship at the 74% confidence level with RMSE 6.4% (n = 36). Conclusions: To compensate the inconsistent significance between calibration and validation, an estimation model robust against various systematic interferences is necessary. The economic efficiency of miscanthus, which is a promising energy resource, can be improved by the real-time measurement of its crucial material properties.

Thermopile Radiometer Calibration Using Reference Instrument (표준준기에 의한 일사계 교정)

  • Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk;Kang, Young-Heak
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.199.2-199.2
    • /
    • 2010
  • The main purpose of the calibration procedure is to perform a one to one comparison of the reference pyranometer and the test pyranometer. In order to achieve this, both pyranometers need to be exposed to exactly the same irradiance, under the same circumstances. There are a number of error sources that could result in a wrong measurement. Most importantly Lamp instability, pyranometer offsets, thermal offsets of junctions, voltmeter offset, voltmeter instability, reference pyranometer instability, tilting of the pyranometers and differences in sensor height. Another sun-disc calibration procedure compares the computed vertical component of the direct irradiance as measured by a pyranometer with that measured by the pyranometer to be calibrated. Readings are taken with the levelled pyranometer on a clear day. Firstly the global irradiance and then the diffuse component are measured. Simultaneously measurement of direct irradiance is made with the pyrheliometer. The ways of performing the calibration and the subsequent calculation have been chosen such that the effect all these error sources has been eliminated as much as possible.

  • PDF

The Design and fabrication of Capacitive Humidity Sensor Having Interdigital Electrodes and Its Signal Processing Circuit (빗살전극형 정전용량형 습도센서와 그 신호처리회로의 설계 제작)

  • Kang, Jeong-Ho;Lee, Jae-Yong;Kim, Woo-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.1
    • /
    • pp.26-30
    • /
    • 2006
  • For the purpose of developing capacitive humidity sensor having interdigital electrodes, interdigital electrode was modeled and simulated to obtain capacitance and sensitivity as a function of geometric parameters like the structural gap and thickness. For the development of ASIC, switched capacitor signal processing circuits for capacitive humidity sensor were designed and simulated by Cadence using $0.25{\mu}m$ CMOS process parameters. The signal processing circuits are composed of amplifier for voltage gain control, and clock generator for sensor driving and switch control. The characteristics of the fabricated sensors are; 1) sensitivity is 9fF/%R.H., 2) temperature coefficient of offset(TCO) is $0.4%R.H./^{\circ}C$, 3) nonlinearity is 1.2%FS, 4) hysteresis is 1.5%FS in humidity range of $3%R.H.{\sim}98%R.H.$. The response time is 50 seconds in adsorption and 70 seconds in desorption. Fabricated process used in this capacitive humidity sensor having interdigital electrode are just as similar as conventional IC process technology. Therefore this can be easily mass produced with low cost, simple circuit and utilized in many applications for both industrial and environmental measurement and control system, such as monitoring system of environment, automobile, displayer, IC process room, and laboratory etc.

Design and Manufacture of X-Band 10 X 10 Waveguide Slot Array Antenna for SAR (SAR용 X-밴드 10 10도파관 슬롯 배열 안테나 설계 및 제작)

  • 신영종;이범선
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.11
    • /
    • pp.1019-1025
    • /
    • 2004
  • The X-band 10${\times}$10 waveguide slot array antenna for SAR is designed, fabricated and measured. The array antenna is designed using the equivalent circuit model based on the field distribution of the dominant mode, TE$\sub$10/, and EM simulation. The method to decide optimum angle of the centered inclined slot(coupling slot) and the optimum of offset of the longitudinal slot(radiating slot) is provided. The designed antenna structure is EM simulated and fabricated. The measured return loss bandwidth is 180 MHz at 9.15 GHz , the side lobe level is below -25 dB, HPBW is about 9$^{\circ}$, and the gain is 25.5 dB. These results are similar to the simulation data.

Characteristics study of the spinning rotor gauges (점성진공계 특성연구)

  • 홍승수;신용현;임종연;정광화
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.4
    • /
    • pp.293-297
    • /
    • 1997
  • Using trace etching method in this study, we measure the energy of argon ions generated in VEBA System which is composed of Marx Generater and Pulse Forming Line. In this system the electron beam of 240 kV, 30 kA, 60 ns is generated. Argon ions are formed through the electron beam ionization of a gas cloud injected by a fast puff valve. Thus argon ions are accelerated into vacuum drift tube by a virtual cathode and seperated with electron beam, consequently, they heat the trace etching plates made of aluminum thin films. The energy of argon ions are determined by the number of aluminum thin films penetrated by the ions. This experimental value corresponds with the theoretical value.

  • PDF

Characteristics of the Momentum Equation in Open Channel Flow (개수로흐름 해석에서 운동량방정식의 특성)

  • Jeon, Min-Woo;Jeon, Jong-Ki
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.3
    • /
    • pp.137-147
    • /
    • 2008
  • The relative magnitudes of the individual terms of the momentum equation are analyzed and compared by analytical methods. The temporal variations of each term are analyzed for the influence factors to runoff expressed by the parameters of the momentum equation, stream slopes and roughness coefficients. The magnitudes of local acceleration and convective acceleration offset each other. The peak time of each term except the gravity term coincides with inflection point of the hydrograph rising limb each other. The magnitudes of each term vary with the channel characteristics, especially when the roughness coefficients are dominant or for the mild stream slopes the pressure term can not be negligible.

A Novel Performance in Hairpin Oscillator using Aperture and PBG (Aperture와 PBG를 이용한 Hairpin 발진기의 성능 개선에 관한 연구)

  • 장욱태;서철헌
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.5
    • /
    • pp.437-443
    • /
    • 2004
  • Aperture has been employed on the ground plane in the hairpin resonator. Aperture has been fabricated by etching the part of the ground effected coupling coefficient and then quality factor of hairpin resonator has been increased. When the hairpin oscillator using aperture has been compared with the conventional hairpin oscillator using microstrip, it has been improved the phase noise about 19 ㏈c @100 ㎑. As a result of PBG connecting to the output of the employing aperture hairpin oscillator, the second and third harmonics are suppressed. In this paper, oscillator has been designed and fabricated in operating 5.8 ㎓ band. The output power has been obtained 0,67 ㏈m and the second harmonic has been suppressed about -53,67 ㏈c.