A Study on Interior Design of Lobby Space in Office Building (오피스 빌딩의 로비공간에 관한 연구)

  • 김성기
    • Korean Institute of Interior Design Journal
    • /
    • no.11
    • /
    • pp.38-44
    • /
    • 1997
  • According to office building design in Korea, building exterior and office automatic systems through introducing IB system have been improved. However, the lower floors of a building are functionally easy to transfer but actually functions as an enterance. Although at takes a large investment by the owner or enterprise, mainly the tenants and neighbors are in a broad sense the actual users. In this point of view, the lobby of an office bulidling which is the connection between the exterior as a public space and the interior as a private area, does not only have the function of an enterance but also has to be an image of the enterprise or the building itself. Therefor the lobby must contain various functions of space.

  • PDF

A Study on Fire Spread between Office Room and Atrium in the Atrium Building

  • Lee, Su-Kyung;Kim, Jong-Hoon;Ko, Han-Mog
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.345-352
    • /
    • 1997
  • We could analyse the fire behavior using the developed software for fire safety assessment in a large space such as atrium. But Korean building law hasn't admitted the result of fire risk assessment in atrium. In the legislation fire resistant wall or shutter must be required between atrium and office rooms, That has obstructed development of building design and fire protection technique in Korea. From this point of view, we made scenarios of fire spread between atrium and office rooms, and then computed fire spread and fire phenomena using FASTLite and Breakl. In this study, we can decide that fire compartmentalization between atrium and office rooms doesn't require in Atrium building if the material and fire protection system were reliable. Consequently, Korean Fire Protection Regulations have to consider in direction of increasing freedom of building.

  • PDF

A Study of applying VAV and VWV System to reduce Energy Consumption of Office building (VAV 및 VWV시스템 적용에 따른 업무용 건축물의 에너지저감에 관한 연구)

  • Song, Ji-Yong;Hong, Won-Hwa;Kim, Ji-Yeon;Park, Hyo-Soon
    • KIEAE Journal
    • /
    • v.13 no.1
    • /
    • pp.57-63
    • /
    • 2013
  • Building Energy Efficiency Rating system was enforced in 2001 to enhance spreading high-energy performance and saving buildings. It was only for the new apartments, but expanded to new office buildings in 2010, and moreover, government offices require 1st grade of Building Energy Efficiency Rating system. Green Building Act, which is established to reduce the emissivity of carbon dioxide by reducing building energy consumption, will be enforced in 2013, and new apartments and office buildings will be subjected to it. Henceforward, it will extend to other types of buildings and will be phased in. In general, pumps and fans consume approximately half of the air-conditioning energy consumption, and about a quarter of the total building energy consumption when office buildings have total floor area of more than 10000 square meters. This study analyzed the energy demand when applying VAV(Variable Air Volume) and VWV(Variable Water Volume) System to reduce energy returns of the pumps and the fans by ECO2, which is a computer simulation program used for Building Energy Efficiency Rating system.

A Process for Replacing BIM Property Information about Internal Finishing of Office Building in Design Phase (업무시설 설계단계 BIM 내부마감 속성정보 교체 프로세스)

  • Han, Ji-Ho;Nam, Dong-Hee;Park, Sang-Hun;Koo, Kyo-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.207-208
    • /
    • 2023
  • The procedure of predicting the construction cost and selecting the best alternative is performed based on comparative review of each building case. In the case of office building, it is required continuously until design is complete, since the owner requirements are various and likely to change during the design process compared to a standardized apartment. However, since the comparison work for each alternative in practice uses only the unit construction cost, there is no correlation between the alternative and the final result, and it is difficult to quantitatively determine the effect of the determined design factor on the total construction cost. It is needed that a means to support the generation of design alternatives using similar building cases during the design phase. This paper proposes a BIM-based data replacing process to support creating and comparison of design alternatives of internal finishing for office building. When design alternatives are created through the proposed process, it is possible to compare several similar cases with current project under equivalent design circumstance. Because only some finishing properties are replaced while maintaining the shape information such as the length, height, and base constraint of the object to be replaced.

  • PDF

A Review on the Definition Methods of Prototypical Office Building for Energy Analysis (에너지해석용 표준 업무용건물의 정의방법에 관한 연구 리뷰)

  • Kim, Hye-Jin;Seo, Dong-Hyun
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.3
    • /
    • pp.103-111
    • /
    • 2018
  • A prototypical building that represents the energy characteristics of buildings can be used as a mean of improving building energy efficiency by supporting policy makers, researchers, architects and engineers. This paper is a fundamental study for the definition of prototypical office building models of Korea. First of all, the term "prototypical buildings" was defined in the context of the representatives of building stock by examining the meanings used from many previous researches. Then, building energy related DB of Korea that is available from public and governmental organization such as MLIT (Ministry of Land, Infrastructure and Transport) and KEEI (Korea Energy Economics Institute) is analyzed in terms of materials for prototypical building definition. Finally, numerous prototypical building studies since 1990's from all of the world were classified with three criteria based on the degrees of the used DB and assumptions in defining prototypical building. The found three criteria are EDPB (Empirical Decision based Prototypical Building), HIPB (Hybrid Information based Prototypical Building) SAPB (Statistical Analysis based Prototypical Building).

A Study on Facades of Buildings - The window area ratio distribution of building facade in Tokyo - (건물파사드에 관한 실측조사 연구 - 일본 동경지역의 벽체의 창면적비를 중심으로 -)

  • Kim, Chong-Min;Choi, Chang-Ho;Lee, Hyun-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.4
    • /
    • pp.71-80
    • /
    • 2003
  • The purpose of this study is to analyze the window area ratio distribution of building facade in Tokyo metropolitan area. The survey was carried out in Marunouchi, Kanda, Kasai and Todoriki district. The results of this study were as follows; to propose of window area ratio production method, analyzed and surveyed window area ratio of each district building-used and to compared every wall window area ratio of building. Every wall window area ratio of office district is $20\sim40%$, ones of non-office district is 15% or 35%. Residential area results are every wall window area ratio of apartment is 35%, ones of a house is 15%. To increase of office building to appear that Kanda, Kasai added window area ratio. But, Marunouchi, Todoriki wad not this tendency. Above mentioned results are made out database.

Greenhouse Gas Emissions from Building Sector based on National Building Energy Database (국가 건물에너지 통합DB 기반 건물부문 온실가스 배출현황)

  • Ji, Chang-Yoon;Choi, Min-Seok;Gwon, Oh-In;Jung, Ha-Rim;Shin, Sung-Eun
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.4
    • /
    • pp.143-152
    • /
    • 2020
  • This study analyzes in detail greenhouse gas emissions in building sector. To this end, this study used data on building characteristics (including building type, region, and construction year) and monthly energy consumptions (including electricity, city gas, and district heat) for all buildings from 2015 to 2018. These data were collected from the National Building Energy Database and the energy consumptions were converted into greenhouse gas (GHG) emissions. The total amount of GHG emissions from the building sector has increased steadily from 2015 (118.1MtCO2eq.) to 2018 (132.6MtCO2eq.). On the other hand, the more recently constructed buildings had lower GHG intensities. This result shows that strengthening building design criteria was effective on the reduction of GHG emissions in buildings, and that the increased buildings contributed to increasing GHG emissions of the building sector. In addition, sales facilities are thought to have the largest reduction potential as they had the highest amount of GHG emissions and GHG intensity. This study is expected to help establish new policies for GHG reduction in building sector as well as to evaluate the effects of existing policies.

A Numerical Study on the Operation of Cooling System in an Office Building (사무소용 건물의 냉방시스템 운전에 관한 수치적 연구)

  • Lee, Seung Woo;Min, Man Ki
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.6
    • /
    • pp.686-695
    • /
    • 1988
  • An algorithm and a computer program were developed for the operational simulation of office building cooling system. Using this computer program, the following results were obtained. ${\bullet}$ There is a critical number of coil rows in AHU with which the cooling system can be operated in maximum efficiency. ${\bullet}$ Energy conservation can be achieved in an office building through TAB(Testing Adjusting and Balancing) of zone air volumes.

  • PDF

A Study on the Interior Design Method of Public-Toilet in Office Building (사무소 건축의 공공화장실 실내설계 기법에 관한 연구)

  • 김정범;김은중
    • Korean Institute of Interior Design Journal
    • /
    • no.16
    • /
    • pp.16-21
    • /
    • 1998
  • This study aims at developing the interior design method of Public Toilet in office building. There needs new concepts in Public Toilet where we felt dirty smelling and dismal in the past. And the behavior in the Public Toilet become various such as combing the hair making-up changing the clothes rinsing out mouth and so on. Nowadays The Public Toilet of office building shows indirectly the hierarchy and the management philosophy of its enterprise, This study treats with the design items such as unit space zoning plan lighting plan and air-conditioning plan and construction method of Public-Toilet in office building. As a result of this study the interior design methods of Public Toilet must reflect use of fitting material lighting plan user's needs and functional divide.(Powder Zone and Physiology Zone) These result will become basic data of future interior design in Public Toilet.

  • PDF

A Study on Indoor Environment Quality in Office Building (오피스 빌딩 실내환경의 질에 관한 연구)

  • Lee, Kyeong-Hee;Ha, Mi-Kyoung
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2006.05a
    • /
    • pp.259-263
    • /
    • 2006
  • The purpose of this study is to assess the characteristics of self-reported symptoms of workers in office building with HVAC system, and also to provide better workplaces in terms of comfort and health. The methods employed in this study include literature review, field observations, and survey. The self-reported symptoms of workers such as headache, fatigue, itching and dryness regarded as SBS symptoms commonly occur after around 3:00 pm and are relieved after leaving their office buildings. according to results in previous studies, above are possibly related to CO2 concentrations. It is also found work environment factors and the satisfaction on indoor environment are all associated with worker's health. Hopefully, this overview of current work environments concerning the level of satisfaction and health problems of workers would help create healthier indoor environment.

  • PDF