• Title/Summary/Keyword: Office Lighting

Search Result 147, Processing Time 0.042 seconds

A Experimental Study on Artificial Illumination Control System Illuminated by Daylighting (자연채광을 이용한 인공조명의 제어방법에 관한 실험적 연구)

  • 차광석;김회서
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.1
    • /
    • pp.21-28
    • /
    • 1994
  • It is very important and necessary to predict luminous enviroment in an interior space. This paper has described about energy saving and evaluated interior visual environment in a office building having on/off turning control lighting system utilizing daylight. In order to predict the interior varior illumination distribution, the scale model was made and examined under various conditions, such ad difference of window glass, and color pattern of wall, floor, and also ceiling lighting system type. This paper suggests that basic fundamental data of lighting design performance in the concept and schematic stages of design.

  • PDF

Annual Intensities (2016-2017) Analysis of Energy Use and CO2 Emission by End Use Based on Measurements of Sample Office Building (표본건물 계측에 의한 업무시설에서의 용도별 에너지사용량 및 CO2 배출량 연간 원단위 (2016 - 2017) 분석)

  • Lim, Han-Young;Lim, Su-Hyun;Jin, Hye-Sun;Kim, Sung-Im;Lee, Soo-Jin;Lim, Jae-Han;Song, Seung-Yeong
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.8
    • /
    • pp.19-27
    • /
    • 2018
  • In this study, annual site and primary energy use intensities (EUIs) and $CO_2$ emission intensities (CEIs) per area by end use were estimated based on the measurement data from June 2016 to May 2017 of 19 sample office buildings in Seoul. In addition, the estimated site EUIs by end use were compared to the U.S. Commercial Buildings Energy Consumption Survey (CBECS) 2012 data. Average site EUIs by end use were found to be in the order of electric appliance (typical floors) > heating > cooling > lighting > air movement > domestic hot water > vertical transportation > city water supply. In the case of primary EUIs and CEIs by end use, electric appliance was found to be the largest. As results of comparison with the CBECS 2012 data, it was found that the site EUIs were similar for heating, cooling, domestic hot water, and electric appliance, etc., but slightly different for lighting and air movement. The number of sample office buildings will continue to increase until 2020 (total number of samples 85) and intensities data by end use will be continuously updated through continuous collection of measurement data.

Electric lighting energy saving through the use of a Fresnel lens based fiber-optic solar lighting system : Simulation and measurements (광화이버 및 Fresnel lens 적용 집광식 자연채광 시스템의 이용을 통한 조명에너지의 절감 : 시뮬레이션 및 실측 비교)

  • Jeong, Haejun;Kim, Wonsik;Kim, Yeongmin;Han, Hyun Joo;Chun, Wongee
    • Journal of Energy Engineering
    • /
    • v.26 no.1
    • /
    • pp.34-44
    • /
    • 2017
  • This paper deals with the effectiveness of a fiber optic solar lighting system that uses a Fresnel lens mounted on a two-axis solar tracker. A series of comparative analyses were made concerning its performance as compared to fluorescent lighting by using a simulation model based on ECOTECT and RADIANCE as well as referring to actual data. ECOTECT was used to model the test room (space) while RADIANCE was used for its indoor lighting conditions (environment). It was found that the average indoor light levels of fluorescent lighting fully satisfy the KS standard (KS A 3011, general office, class [G]: 300-400-600lux) whereas those of the solar lighting with light diffusers depends on the occlusion factor of roller shades installed on the south window.

A Research on the actual condition of Korean office lighting (우리나라 사무소조명의 실태조사연구)

  • 지철근
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.2 no.2
    • /
    • pp.47-54
    • /
    • 1988
  • 우리나라 사무실조명의 실태조사결과, 평균조도는 대체로 추천조도의 1/2에도 미달되는 빈약한 조명상태이다. 활동능률측면이나, 국민보건측면에서도 적절한 전정시설의 증설로 조도 수준의 향상이 절실히 요망된다.

  • PDF

An Analysis of the Comparison for a Trend on the Interior Lighting Design of High-rise Office Buildings Between Overseas and Domestic (국내.외 초고층 오피스건축물의 조명설계 경향 비교 분식)

  • Jeong, Keun-Young;Hong, Seong-Kwon;Chol, An-Seop;Lee, Jeong-Ho;Mistrick, Richard
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.42-50
    • /
    • 2008
  • There are many plans of the high-rise buildings these days in domestic and will be constructed from now on. It is required to develop energy saving techniques immediately because the high-rise buildings consume a lot of energy. The most effective energy savings method is the application of the efficient lighting designs and fixtures. The purpose of this study is to analyze a trend of lighting design, fixture and control system between overseas and domestic. It can be used the guide line for the high-rise buildings in domestic application.

A Case Study of Application of the ecological Design - Focused on office building - (생태적 디자인 적용 사례에 관한 기초 연구 - 오피스 빌딩을 중심으로 -)

  • 정효경
    • Korean Institute of Interior Design Journal
    • /
    • no.41
    • /
    • pp.71-79
    • /
    • 2003
  • The quality of the environment, both natural and man-made, has unlimited influence on people's behavior and their physical and psychological well being. Interior designers shaped the indoor environment in which people live, work, perform day-to-day tasks and rest. Since designers affect a society's sensitivity and thinking, the aesthetics and ethics of the designs must respond to the most burning environmental issues of the contemporary world. This awareness is especially important now, at this critical time in the life of our planet, when humanity is facing twin catastrophes: natural resources depletion and environmental degradation. Under this concept, the purpose of this study is to configure what kind of design is ecologic and sustainable design and how we can develop ecological design as focusing on natural ventilation, natural lighting, uses of recycled materials, application of Indoor landscaping and architectural forms through several existing cases of the ecological office building.

Evaluation of Energy Consumptions in Daylight Responsive Dimming Systems (광센서 조광제어시스템의 소비전력 평가)

  • Lee, Soon-Ji;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.195-199
    • /
    • 2006
  • This study aims to measure amount of the reduction ratio of energy consumptions by the daylight responsive dimming systems, which uses daylighting and electric lighting. The results of this study show that the reduction ratio of electric power is better 'clear sky' by sky condition and 'window side of room' by zoning. When calculating reduction ratio of energy consumptions with used times in real office space, it tells that the result of real office was higher ratio than that of experimental space. For this study which presents efficient use of daylight in office environment, it will be basis of improving energy performance.

  • PDF

A Study on Visual Comfort for Light Control Method of Applied Daylighting (자연채광방식의 응용에 따른 시각적 쾌적성에 관한 연구)

  • Han, Sang-Pil;Han, Sang-Cheol
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.140-145
    • /
    • 2012
  • The purpose of this study is to understand the change of impression by comparing the uniformity lighting with the compound lighting. In previous study, we proposed a light controlling method to harmonize daylight from a window and artificial lights from a ceiling and obtained the results to support our method. We referred this method as the Adjusted Compound-Lighting Model (AC Model). The model claims that lighting in a room with a side-window are perceived as harmonious when the overall light distribution in the room is well approximated by a compound of lights from the window and the entire ceiling. The experiment is carried out with the scaled-models and mock-up spaces that were supposed to be an office space. One is lit by the uniform lighting and the other by the compound lighting in each experimental space. In order to present varying illuminance distributions, thetwo variables were used in this study. One was the ratio of thelight from the window and ceiling in the standard and evaluation box. The standard box was provided by the ratio of 20% to 40% from the window and 80% to 60% from the ceiling as two lighting ratio patterns [Wu20(=Cu80) and Wu40(=Cu60)]. And the evaluation box was provided by the light ratio of 0% to 40 from the window and 100% to 60% from the ceiling [Wcp0(=Ccp100), Wcp20(=Ccp80) and Wcp40(=Ccp60)]. The other variable was themean illuminance level in both boxes. Two level of mean illuminance (700lx and 300lx) were used in this experiment. Each lighting condition was established at equal horizontal mean illuminance level, held constant near 700lx or 300lx in both boxes. Both of them were similar in the shape of distribution when there were same ratios of lights from the window and the ceiling. Subjects were asked to evaluate the point of difference by semantic differential rating on their overall impression after comparing with two rooms. The results showed that the impressions of compound lighting were more positive score than that of uniformity lighting on the items of 'dim-bright', 'dislike-like', 'artificial-natural' and 'closed-open', and that there was no significant difference in impressions between two spaces on other items.

  • PDF

A Study on the Guideline of Toilets Design for Elementary Lower-Grade Students - Based on the Survey for Elementary Schools under Seoul Gangseo District Office of Education - (초등학교 저학년 화장실 공간디자인 개선에 관한 연구 - 서울강서교육지원청 관할 초등학교 사례조사를 바탕으로 -)

  • Yoon, Hyun-Young;Jeong, Yoo-Na
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.1
    • /
    • pp.307-317
    • /
    • 2013
  • Elementary school's physical environment is critical to lower grade students. Among the many physical conditions, Toilet, which belongs to health and sanitation category is very important to those who start school for the first time. The purpose of this study is for suggesting the guidelines of toilet design reflecting psychological and behavioral aspects of lower grade students. The research was executed as follows. Firstly, focused survey groups were carefully chosen. Five elementary schools were selected, being all open after 2005 under Seoul Gangseo District Office of Education. Secondly, field study was executed to find out toilet usage, during the period between April to June 2012, by visiting schools to see basic facilities, taking pictures and making actual measurement in each toilets. The architectural analysis was focused on location, moving line, actual size and space zoning, while the interior analysis being on finishing materials and the design of sanitary equipments. And the design elements such as color, lighting fixture, art works or signage were analysed, too. Finally, questionnaire survey was done to find out preferences of lower grade students. As a result, the guidelines of toilet design can be divided into two main parts, Physical and Psychological. For the Physical part, it is necessary for related facilities to be concentrated in order to give easy access. In addition, good ventilation, better lighting and to install sanitary equipments ergonomically are required. Furthermore, safe and clean maintenance should be considered. Psychologically, the design should be directed for making lower grade students come to toilets with comfort and more pleasantly.

An Analysis of Daylighting Performance of Light Shelf in Office Building (사무소 건물에서 광선반의 채광성능 분석)

  • Park, Byung-Il;Yang, In-Ho;No, Mi-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.8
    • /
    • pp.1-11
    • /
    • 2008
  • The purpose of this study is to present the design guideline for an effective application of light shelf in office building. For this, the computer simulation using Daylighting System of 3Ds Studio Max was performed, and the optimal values related to design factors such as a depth, a surface reflectance and a installation angle of light shelf were obtained. Then daylighting performance of light shelf using the optimal values was analyzed, and the simulation results show that the installation of the optimal light shelf can improve a indoor lighting environment in office building.