• 제목/요약/키워드: Off-grid

검색결과 217건 처리시간 0.027초

계통 연계형 컨버터의 능동 댐핑을 위한 공진주파수 추정 기능에 관한 연구 (A Study on the Estimation of the Resonance Frequency for an Active Damping Technique of Grid Connected Converters)

  • 박일우;이우철
    • 조명전기설비학회논문지
    • /
    • 제27권1호
    • /
    • pp.76-84
    • /
    • 2013
  • The renewable energy sources is raising for use of grid connected systems, for which higher power quality requirements are being issued. A grid connected converter requires a LC-filter stage, this one is lightly damped for efficiency constraints. Hence, it is subject to resonance if excited by the converter current harmonics or pre-exciting grid voltage harmonics. In this paper, an active damping technique employing notch filter for damping of the resonance frequency is introduced. This technique doesn't need to additional sensors. In addition, it is simple to apply for various systems. Monitoring of the resonance frequency ensures the stable operation of the proper connection and disconnection of the grid. This paper proposes the estimating method of a resonant frequency to determine the cut-off frequency of the notch filter. This method is validated by both simulation and experimental results.

Slip-Mode Frequency Shift 단독운전 검출 기법의 정상상태 전력 품질 개선 (Design of Modified Slip-Mode Frequency Shift Islanding Detection Method for Power Quality Improvement)

  • 김동욱;김성민
    • 전기전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.539-547
    • /
    • 2018
  • 계통 연계형 인버터는 단독운전 조건에서 반드시 전력 공급을 차단해야 한다. 이러한 이유로 분산 발전 시스템은 단독운전을 검출 기능을 반드시 가지고 있어야 한다. 분산 발전용 인버터에 적용되는 일반적인 방법 중에는 Slip-Mode frequency Shift (SMS) 단독운전 검출 기법이 있다. SMS 기법은 계통 전압의 주파수에 따라 무효 전력을 공급하여 단독운전 조건에서 계통 주파수를 허용 범위 밖으로 이동시키는 방법이다. SMS 기법은 안정적으로 단독운전을 검출할 수 있으며, 계통 전류에 고주파를 인가하지 않는다는 장점이 있으나, 무효 전류를 인가하기 때문에 계통 역률이 나빠져서 전력 품질의 저하를 가져온다. 본 논문에서는 계통 전원이 연결되어 있는 정상 조건에서 전력 품질 저하가 없는 수정된 SMS 기법을 제안한다. 600W 단상 인버터 실험을 통해 제안된 방법의 유효성을 검증한다.

강성 및 컴플라이언트 행오프 하에서의 미연결송유관의 동력학 (Dynamics of disconnected risers under rigid and compliant hang-off)

  • ;윤덕영
    • 한국해양공학회지
    • /
    • 제1권2호
    • /
    • pp.39-51
    • /
    • 1987
  • 석유시추 보호관의 비선형 운동을 시뮬레이트하는 유효한 해법이 non-uniform grid 유한차분법과 implicit time 적분법에 근거하여 제시되었다. 극한 상태에 있는 지지 플랫폼의 상승 가속도에 의해 생기는 보호관의 동적 좌굴형 반응에 관하여 상세히 연구되었고, 이 반응에 미치는 중요 변수가 규명되었다. 운동의 현저한 감소와 이에 따른 응력들이 컴플라이언트 행오프(hang-off)를 적용시킴으로써 얻어졌다.

  • PDF

SCTTS: Scalable Cost-Time Trade-off Scheduling for Workflow Application in Grids

  • Khajehvand, Vahid;Pedram, Hossein;Zandieh, Mostafa
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제7권12호
    • /
    • pp.3096-3117
    • /
    • 2013
  • To execute the performance driven Grid applications, an effective and scalable workflow scheduling is seen as an essential. To optimize cost & makespan, in this paper, we propose a Scalable Cost-Time Trade-off (SCTT) model for scheduling workflow tasks. We have developed a heuristic algorithm known as Scalable Cost-Time Trade-off Scheduling (SCTTS) with a lower runtime complexity based on the proposed SCTT model. We have compared the performance of our proposed approach with other heuristic and meta-heuristic based scheduling strategies using simulations. The results show that the proposed approach improves performance and scalability with different workflow sizes, task parallelism and heterogeneous resources. This method, therefore, outperforms other methods.

A Modified Single-Phase Transformerless Z-Source Photovoltaic Grid-Connected Inverter

  • Liu, Hongpeng;Liu, Guihua;Ran, Yan;Wang, Gaolin;Wang, Wei;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1217-1226
    • /
    • 2015
  • In a grid-connected photovoltaic (PV) system, the traditional Z-source inverter uses a low frequency transformer to ensure galvanic isolation between the grid and the PV system. In order to combine the advantages of both Z-source inverters and transformerless PV inverters, this paper presents a modified single-phase transformerless Z-source PV grid-connected inverter and a corresponding PWM strategy to eliminate the ground leakage current. By utilizing two reversed-biased diodes, the path for the leakage current is blocked during the shoot-through state. Meanwhile, by turning off an additional switch, the PV array is decoupled from the grid during the freewheeling state. In this paper, the operation principle, PWM strategy and common-mode (CM) characteristic of the modified transformerless Z-source inverter are illustrated. Furthermore, the influence of the junction capacitances of the power switches is analyzed in detail. The total losses of the main electrical components are evaluated and compared. Finally, a theoretical analysis is presented and corroborated by experimental results from a 1-kW laboratory prototype.

DFT를 이용한 계통연계 인버터 시스템의 고정밀 계측 (High Precise Measurement of Grid-Connected Inverter using DFT)

  • 이상혁;강필순;이상훈;조수억;이태원;박성준
    • 전력전자학회논문지
    • /
    • 제17권2호
    • /
    • pp.93-98
    • /
    • 2012
  • A precise measurement of the grid voltage is one of the essential techniques, which is required to connect a renewable energy to the grid. In general, when a filter is used to eliminate unnecessary harmonics and noises, a signal is distorted by phase delay, amplitude attenuation, and other distortions. And the response characteristic of a controller is directly affected by bandwidth of cut-off frequency of the filter. To alleviate this problems, we propose an effective algorithm based on DFT(Discrete Fourier Transform) instead of approaching the filter application. The proposed algorithm ensures high precise measurement of the grid voltage because it can extract the fundamental and harmonics from the raw signal without any distortions. The high performance of the proposed algorithm is verified by PSIM simulation and experiments of Grid-Connected VSI.

The Development and Application of a Training Base for the Installation and Adjustment of Photovoltaic Power Generation Systems

  • Chuanqing, SUN
    • International Journal of Advanced Culture Technology
    • /
    • 제4권1호
    • /
    • pp.37-50
    • /
    • 2016
  • In recent years, the development and application of green energy resources have attracted more and more /$^*$ 'tention of people. The training room presented here is focused on the terminal applications of a photovoltaic power generation system (PPGS). Through introducing the composition and the general design principles, we aimed at leading the students to master the fundamental skills required for its design, installation and construction. The training room consists of numerous platforms, such as: PPGS, Wind and Photovoltaic Hybrid Power Generation Systems, Wind Power Generation Equipments, Simulative Grid-Connected Power Generation System, Electronic Technology Application of New Energy, etc. This enables the students to obtain their project and professional skills training via assembling, adjusting, maintaining and inspecting, etc., various component parts of the photovoltaic and new energy power generation systems, to further grasp the fundamental and related theoretical knowledge, and to further reinforce their practical and operational skills, so as to improve their problem-analyzing and problem-solving abilities.

단상 계통 연계형 풀브릿지 인버터의 스위치 손실 모의 및 분석 (Simulation and Analysis of Losses of Switching Device for Single Grid-connected Full Bridge Inverter)

  • 손명수;임현지;조영훈
    • 전력전자학회논문지
    • /
    • 제23권4호
    • /
    • pp.294-297
    • /
    • 2018
  • This paper analyzes the losses of the switching device for a full bridge inverter connected to the grid. As the development of power conversion system, losses are dominant factors in judging the efficiency of a system. The losses of a switching device can be divided into switching loss and conduction loss, both of which can be estimated by analyzing periodic switching waveform. The switching loss is generated when the switch is turned on and off, while the conduction loss is generated when the switch is turned on. The estimated losses of the MOSFET switch are compared with the simulation results.

Fixed-Grid Simulation of Convection-Dominated Melting in a Rectangular Cavity

  • Wongee Chun;Kim, Sin;Kim, Min-Chan
    • Journal of Mechanical Science and Technology
    • /
    • 제15권6호
    • /
    • pp.796-803
    • /
    • 2001
  • Numerical solutions for the convection-dominated melting in a rectangular cavity are presented. The enthalpy-porosity model is employed as the mathematical model. This model is applied in conjunction with the EIT method to detect boundary movement in a phase changing environment. The absorption and evolution of latent heat during the phase change is dealt with by the enthalpy-based energy equation. This seems to be more efficient than resolving the temperature-based energy equation. The velocity switch-off, which is required when solid changes into liquid, is modeled by the porous medium assumption. For efficiency and simplicity of the solutions procedure, this paper proposes a simple algorithm, which iterates the temperature and the liquid fraction of the cells comprising the front layer. The numerical results agree reasonably well with the experimental data and other previous works using the transformed-grid system.

  • PDF

Clustering Algorithm by Grid-based Sampling

  • 박희창;유지현
    • 한국데이터정보과학회:학술대회논문집
    • /
    • 한국데이터정보과학회 2003년도 춘계학술대회
    • /
    • pp.97-108
    • /
    • 2003
  • Cluster analysis has been widely used in many applications, such that pattern analysis or recognition, data analysis, image processing, market research on on-line or off-line and so on. Clustering can identify dense and sparse regions among data attributes or object attributes. But it requires many hours to get clusters that we want, because of clustering is more primitive, explorative and we make many data an object of cluster analysis. In this paper we propose a new method of clustering using sample based on grid. It is more fast than any traditional clustering method and maintains its accuracy. It reduces running time by using grid-based sample. And other clustering applications can be more effective by using this methods with its original methods.

  • PDF