• 제목/요약/키워드: Off-gas

검색결과 894건 처리시간 0.025초

시동 배기가스 점화기술을 이용한 촉매의 예열시간 단축 (Fast Light-Off of Catalyst using Cranking Exhaust Gas Ignition)

  • 조용석;엄인용;이윤석;김득상;김충식;천준영;최진욱
    • 한국자동차공학회논문집
    • /
    • 제9권2호
    • /
    • pp.43-49
    • /
    • 2001
  • In order to satisfy the ULEV emissions regulation, fast light-off of a catalyst is essential for reduction of HC and CO emissions during the cold start. Cranking Exhaust Gas Ignition(CEGI) method developed in this study showed that the catalyst reaches the light-off temperature in a few seconds. The CEGI stops the ignition signal for a few seconds during the cranking period, so the unburned fuel-air mixture bypasses the combustion chamber and flows through the exhaust manifold. When the unburned mixture reaches two glow plugs installed upstream of the catalyst, it burns and releases the thermal energy to heat up the catalyst, In the FTP-75 vehicle tests, the CEGI showed that the exhaust emissions reduced by 47.7% for THC and by 88.6% for CO in the cold-transient phase of the test.

  • PDF

제어방식에 따른 산업용 수냉각기의 운전 특성 비교 (A Comparison of Operating Characteristics for Industrial Water Cooler with Variation of Control Methods)

  • 백승문
    • 동력기계공학회지
    • /
    • 제18권6호
    • /
    • pp.99-105
    • /
    • 2014
  • This paper presents a comparison of operating characteristics for industrial water cooler with variation control methods. The performance analysis regarding the characteristics of condensation capacity, evaporation capacity, compressor load, COP of an on-off type cooler, a hot gas-bypass control type cooler and an inverter control type cooler with respect to the system load is reviewed, respectively. The primary results are as following: the variation of required compressor load of an on-off type cooler with respect to load is 5%, that of hot gas-bypass type is 18% and 66% for an inverter control type cooler. As the result shows, an inverter control type yields relatively huge difference of required compressor load compared to other types of control system. In terms of partial load, COP of an inverter control type cooler presents the highest value, and is considered as the optimized type for the used of the system involving frequent partial load.

가솔린 기관의 냉간시동 조건에서 합성가스 배기분사 기술에 의한 촉매의 활성화 온도 도달시간 단축 및 유해배출물 저감에 관한 연구 (Study on Shortening Light-Off Time of Three Way Catalyst and Reduction of Harmful Emissions with Exhaust Synthetic Gas Injection(ESGI) Technology during Cold Start of SI Engines)

  • 조용석;이성욱;원상연;송춘섭;박영준
    • 한국자동차공학회논문집
    • /
    • 제16권3호
    • /
    • pp.94-101
    • /
    • 2008
  • Since regulations of exhaust emissions are continuously reinforced, studies to reduce harmful emissions during the cold start period of SI engines have been carried out very extensively worldwide. During the cold start period, raising the temperature of cold exhaust gas is a key strategy to minimize the light-off time of three way catalysts. In this study, a synthetic gas containing a large amount of hydrogen was injected into the exhaust manifold to raise the exhaust gas temperature and to reduce harmful emissions. The authors tried to evaluate changes in exhaust gas temperature and harmful emissions through controlling the engine operating parameters such as ignition timings and lambda values. Also the authors investigated both combustion stability and reduction of harmful emissions. Experimental results showed that combustion of the synthetic gas in the exhaust manifold is a very effective way for solving the problems of harmful emissions and light-off time. The results also showed that the strategy of retarded ignition timings and increased air/fuel ratios with ESGI is effective in raising exhaust gas temperature and reducing harmful emissions. Futhermore, the results showed that engine operating parameters ought to be controlled to lambda = 1.2 and ignition timing = $0{\sim}3^{\circ}$ conditions to reduce harmful emissions effectively under stable combustion conditions.

Development and Application of Multi-Function Valve to Solve Major Problems of Expansion and Off-Odor Leakage in the Packaging of Kimchi

  • Jeong, Suyeon;Cho, Chi Heung;Lee, Hyun-Gyu;Lee, Jung-Soo;Yoo, SeungRan
    • 한국포장학회지
    • /
    • 제24권3호
    • /
    • pp.113-120
    • /
    • 2018
  • The one-way gas valve developed in this study was designed to prevent the breakage of packages from increased internal pressure, which is a problem in packaged Kimchi, and simultaneously reduce the outflow of the offodor release. The effect of the one-way gas valve on the headspace atmospheric compositions was investigated in the packaging system. The changes of atmospheric compositions and quality factors of Kimchi, such as $CO_2$ accumulation, pH, titratable acidity, and salinity, were measured during a 4-week storage period at $4^{\circ}C$. The Kimchi package with the one-way gas valve dramatically reduced pressure build-up in the pouch by allowing the controlled flow of gas to the atmosphere. In addition, the package design allows the possibility of controlling the gas generated from Kimchi by adjusting the viscosity of the open pressure control oil. The one-way gas valve did not affect the sensory characteristics of Kimchi products during the storage period. Furthermore, the deodorizing capability of the activated carbon contained in the one-way gas valve effectively reduced the off-odor of Kimchi products released along with carbon dioxide. The novel one-way gas valve is considered to be an active packaging system that can solve major problems of expansion and off-odor leakage in the packaging of Kimchi.

가솔린 엔진의 배기 열교환기가 촉매 온도에 미치는 영향에 관한 연구 (Effect of Exhaust Heat Exchanger on Catalytic Converter Temperature in an SI Engine)

  • 이석환;배충식
    • 한국자동차공학회논문집
    • /
    • 제12권2호
    • /
    • pp.9-16
    • /
    • 2004
  • Close-coupled catalyst (CCC) can reduce the engine cold-start emissions by utilizing the energy in the exhaust gas. However, in case the engine is operated at high engine speed and load condition, the catalytic converter may be damaged and eventually deactivated by thermal aging. Excess fuel is sometimes supplied intentionally to lower the exhaust gas temperature avoiding the thermal aging. This sacrifices the fuel economy and exhaust emissions. This paper describes the results of an exhaust heat exchanger to lower the exhaust gas temperature mainly under high load conditions. The heat exchanger was installed between the exhaust manifold and the inlet of close-coupled catalytic converter. The exhaust heat exchanger successfully decreased the exhaust gas temperature, which eliminated the requirement of fuel enrichment under high load conditions. However, the cooling of the exhaust gas through the heat exchanger may cause the deterioration of exhaust emissions at cold start due to the increment of catalyst light-off time.

배기 가스 유량 제어를 이용한 버너방식 디젤 입자상물질 제거 장치의 재생 (Regeneration of Burner Type Diesel Particulate Trap System Through Active Exhaust Gas Feeding)

  • 김재업;박동선;이만복;김응서
    • 한국자동차공학회논문집
    • /
    • 제5권1호
    • /
    • pp.1-13
    • /
    • 1997
  • The key point that guarantees the durability of the ceramic monolith filter is to lower peak temperature and temperature gradient inside filter during regeneration. The control of the exhaust gas flow rate into the filter, by the bypass technique of the exhaust gas, enables the gas temperature in filter to be constant for regeneration. A couple of methods, which are the ON/OFF and PID control of the bypass valve, were used for feedback control of the gas temperature. These techniques showed that the ceramic filter was regenerated perfectly under the peak temperature and peak temperature gradient limitations for durability.

  • PDF

하폐수의 재사용 및 방류를 위한 폭기조 내 표준산소전달 효율 모니터링 시스템에 관한 연구 (Study on the Standard Oxygen Transfer Efficiency Monitoring System in the Aeration Tank for Reuse and Discharge of Wastewater)

  • 김홍석;김용범;고경한;김상우;심환보
    • 자원리싸이클링
    • /
    • 제28권6호
    • /
    • pp.73-78
    • /
    • 2019
  • 본 연구에서는 활성 슬러지 하수처리장에서 배출되는 off-gas에 대한 포집 및 측정 모니터링을 통해 폭기조의 산소전달효율을 측정하고 청수와 비교하여 시스템의 신뢰성을 검증하는 연구를 수행하였다. 먼저, 청수를 기반으로 용존산소, 산소전달계수 및 표준산소전달효율을 측정하였으며 각각 8.60 mg/L, 9.49/hr, 23.96%의 값이 얻어졌다. 한편, 하수처리장 현장에서 진행한 off-gas 시험 결과 표준산소전달효율이 22.81%로 계산되어 청수와의 차이가 거의 없는 것으로 나타났다. 이는 현장에 설치된 산기관의 성능 및 폭기조의 상황을 모니터링 시스템을 이용해 실시간으로 확인함으로써 신뢰성있는 데이터를 확보할 수 있음을 의미한다.

열전달 해석을 이용한 멤브레인형 LNG 화물창의 단열구조 성능비교 (Comparative Study on the Thermal Insulation of Membrane LNG CCS by Heat Transfer Analysis)

  • 황세윤;이장현
    • 한국전산구조공학회논문집
    • /
    • 제29권1호
    • /
    • pp.53-60
    • /
    • 2016
  • 본 연구는 NO96 화물창의 BOG(boil off gas), BOR(boil off rate)을 감소시키기 위한 노력으로 단열재료 및 단열층을 변화시켜서 개발된 NO96-GW, NO96-L03의 방열구조에 대해서 BOG, BOR 값을 계산하고 단열성능을 비교 평가하였다. 두가지의 변형된 NO96 모델을 기존의 NO96 방열과 단열층 및 단열재료의 차이점을 비교하고, 각각의 열저항 및 BOG/BOR 값의 비교 결과를 제시하였다. 열저항 값은 유한요소해석법을 이용하여 계산되었으며, 준정적 열평형 상태를 가정하여 열유속과 온도분포를 통하여 단열성능을 비교하였다. 계산에 사용된 화물창의 모든 재료물성치는 온도 의존값으로서 반영하여 $-163^{\circ}C$에서의 극저온 상태에서 특성을 반영되었다. 각 화물창의 BOG, BOR 계산은 국부 열전달 해석을 통해 방열판에서 발생하는 열유속을 계산하고, 등가모델을 적용하여 계산하는 과정으로 수행되었으며, 그 결과를 각 화물창의 단열성능을 비교 평가하기 위해서 검토하였다.

냉열을 이용한 LNG 증발기체 BOG 재액화 신공정과 기존공정에 관한 비교연구 (Study on the Comparison of New and Used Reliquefaction System of Boil-Off-Gas by LNG Cold Energy)

  • 이동혁;장창봉;정상용;김정환;이헌석;김범수;고재욱
    • 한국가스학회지
    • /
    • 제14권1호
    • /
    • pp.42-46
    • /
    • 2010
  • LNG (Liquefied Natural Gas)기지의 LNG 저장탱크에서 BOG (Boil Off Gas)가 약 0.5 vol%/day로 자연적으로 생성된다. 이를 회수하기 위해서 기존에는 LNG와 BOG를 1:12의 질량비로 직접 접촉시켜 액화시켰다. 이 공정은 단순하지만 하절기에는 LNG 사용량 저하로 인해 공정운영의 어려움이 있다. 이러한 단점을 보완하기 위해 대안된 LNG 냉열을 사용하는 간접접촉방식을 HYSYS를 이용하여 분석해보고 직접접촉방식과 BOG 재액화 효율비교를 통해 분석하여 유리한 공정을 도출하였다.

LNG선박용 BOG 부분재액화 시스템 특성 연구 (Characteristics of boil-off-gas partial re-liquefaction systems in LNG ships)

  • 윤상국
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권3호
    • /
    • pp.174-179
    • /
    • 2016
  • 해양의 환경오염을 줄이기 위하여 LNG 운송선박, 벙커링 선박 및 LNG를 연료로 추진되는 선박의 건조가 증가하고 있다. 이러한 LNG 선박의 저장탱크들은 외부로부터의 열유입으로 증발가스가 지속적으로 발생하고 있으며, 최근 국내 조선사들은 이 BOG를 재액화하여 회수하는 장치를 개발하여 보급하고 있다. 본 연구에서는 부분재액화 처리장치들의 이론적 최대 재액화 수율을 분석하고 재액화 수율에 미치는 영향 인자들을 비교하였다. 해석결과, BOG와 플래시 가스가 보유한 냉열을 열교환으로 간접 이용하는 부분재액화 처리장치는 최대 48.7%가 되었으며, BOG와 플래시 가스가 혼합 합체되어 냉열이 직접 이용되는 부분재액화 처리장치는 최대 41%로 해석되었다. 또한 액체 수율에 크게 영향을 미치는 인자로는 열교환기의 효율로 열교환기의 성능과 단열이 매우 중요한 것임을 알 수 있다.