Abstract
In this investigation, off-gas generated from the activated sludge in wastewater treatment plant was monitored. Through monitoring, the oxygen transfer efficiency in the aeration system and the reliability was evaluated by comparing to clean water. First, the dissolved oxygen, oxygen transfer coefficient, and standard oxygen transfer efficiency were measured based on clean water, and the values were 8.60 mg/L, 9.490/hr and 23.96%, respectively. The off-gas monitoring at the wastewater treatment plant indicated that the standard oxygen transfer efficiency was 22.81%. Little difference in oxygen transfer efficiency this data inferred that the performance was improved through diffuser installation in the field monitoring system.
Keywords
wastewater treatment; off-gas; standard oxygen transfer efficiency; aeration system; monitoring system;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Liu, C., Li, S., and Zhang, F., 2011 : The Oxygen Transfer Efficiency and Economic Cost Analysis of Aeration System in Municipal Waste Water Treatment Plant, Energy Proc., 5, pp.2437-2443.   DOI
2 Kaliman, A., Rosso, D., Leu, S. Y., and Stenstrom, M. K., 2008 : Fine-Pore Aeration Diffusers: Accelerated Membrane Ageing Studies, Water Res., 42, pp.467-475.   DOI
3 Rozich, A. F., 1992 : Design and operation of activated sludge processes using respirometry, Lewis Publisher.
4 Rosso, D., Larson, L. E., and Stenstrom, M., 2008 : Aeration of large-scale municipal wastewater treatment plants: state of the art, Wat. Sci. Tech., 57, pp.973-978.   DOI
5 Olsson, G. and Andrews, J. F., 1981 : Dissolved oxygen control in the activated sludge process, Wat. Sci. Tech., 13, pp.341-347.
6 Harris, S. L., Stephenson, T., and Pearce, P., 1996 : Aeration investigation of biological aerated filters using off-gas analysis, Wat. Sci. Tech., 34, pp.307-314.   DOI
7 Lewis, W. K. and Whitman, W. G., 1924 : Principle of gas absorption, Ind. Eng. Chem., 16, pp.1215-1220.   DOI
8 Viswanathan, S., Pham, H., Kelly, R. F., Redmon, D. T., and Fernandes, W., 2008 : Evaluation of Oxygen Transfer Efficiency via Off-gas Testing at Full Scale Integrated Fixed film Activated Sludge Installation, In: Proc. WEFTEC 2008 Conference.
9 Libra, J. A., Schuchardt, A., Sahlmann, C., Handschag, J., Wiesmann, U., and Gnirss, R., 2002 : Comparison of the efficiency of large-scale ceramic and membrane aeration systems with the dynamic off-gas method, Wat. Sci. Tech., 46, pp.317-324.
10 Amerlinck, Y., Bellandi, G., Amaral, A., Weijers, S., and Nopens, I., 2016 : Detailed off-gas measurements for improved modelling of the aeration performance at the WWTP of Eindhoven, Wat. Sci. Tech., 74, pp.203-211.   DOI