• Title/Summary/Keyword: Off-gas

Search Result 898, Processing Time 0.023 seconds

Fast Light-Off of Catalyst using Cranking Exhaust Gas Ignition (시동 배기가스 점화기술을 이용한 촉매의 예열시간 단축)

  • 조용석;엄인용;이윤석;김득상;김충식;천준영;최진욱
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.2
    • /
    • pp.43-49
    • /
    • 2001
  • In order to satisfy the ULEV emissions regulation, fast light-off of a catalyst is essential for reduction of HC and CO emissions during the cold start. Cranking Exhaust Gas Ignition(CEGI) method developed in this study showed that the catalyst reaches the light-off temperature in a few seconds. The CEGI stops the ignition signal for a few seconds during the cranking period, so the unburned fuel-air mixture bypasses the combustion chamber and flows through the exhaust manifold. When the unburned mixture reaches two glow plugs installed upstream of the catalyst, it burns and releases the thermal energy to heat up the catalyst, In the FTP-75 vehicle tests, the CEGI showed that the exhaust emissions reduced by 47.7% for THC and by 88.6% for CO in the cold-transient phase of the test.

  • PDF

A Comparison of Operating Characteristics for Industrial Water Cooler with Variation of Control Methods (제어방식에 따른 산업용 수냉각기의 운전 특성 비교)

  • Baek, Seung-Moon
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.99-105
    • /
    • 2014
  • This paper presents a comparison of operating characteristics for industrial water cooler with variation control methods. The performance analysis regarding the characteristics of condensation capacity, evaporation capacity, compressor load, COP of an on-off type cooler, a hot gas-bypass control type cooler and an inverter control type cooler with respect to the system load is reviewed, respectively. The primary results are as following: the variation of required compressor load of an on-off type cooler with respect to load is 5%, that of hot gas-bypass type is 18% and 66% for an inverter control type cooler. As the result shows, an inverter control type yields relatively huge difference of required compressor load compared to other types of control system. In terms of partial load, COP of an inverter control type cooler presents the highest value, and is considered as the optimized type for the used of the system involving frequent partial load.

Study on Shortening Light-Off Time of Three Way Catalyst and Reduction of Harmful Emissions with Exhaust Synthetic Gas Injection(ESGI) Technology during Cold Start of SI Engines (가솔린 기관의 냉간시동 조건에서 합성가스 배기분사 기술에 의한 촉매의 활성화 온도 도달시간 단축 및 유해배출물 저감에 관한 연구)

  • Cho, Yong-Seok;Lee, Seang-Wock;Won, Sang-Yeon;Song, Chun-Sub;Park, Young-Joon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.3
    • /
    • pp.94-101
    • /
    • 2008
  • Since regulations of exhaust emissions are continuously reinforced, studies to reduce harmful emissions during the cold start period of SI engines have been carried out very extensively worldwide. During the cold start period, raising the temperature of cold exhaust gas is a key strategy to minimize the light-off time of three way catalysts. In this study, a synthetic gas containing a large amount of hydrogen was injected into the exhaust manifold to raise the exhaust gas temperature and to reduce harmful emissions. The authors tried to evaluate changes in exhaust gas temperature and harmful emissions through controlling the engine operating parameters such as ignition timings and lambda values. Also the authors investigated both combustion stability and reduction of harmful emissions. Experimental results showed that combustion of the synthetic gas in the exhaust manifold is a very effective way for solving the problems of harmful emissions and light-off time. The results also showed that the strategy of retarded ignition timings and increased air/fuel ratios with ESGI is effective in raising exhaust gas temperature and reducing harmful emissions. Futhermore, the results showed that engine operating parameters ought to be controlled to lambda = 1.2 and ignition timing = $0{\sim}3^{\circ}$ conditions to reduce harmful emissions effectively under stable combustion conditions.

Development and Application of Multi-Function Valve to Solve Major Problems of Expansion and Off-Odor Leakage in the Packaging of Kimchi

  • Jeong, Suyeon;Cho, Chi Heung;Lee, Hyun-Gyu;Lee, Jung-Soo;Yoo, SeungRan
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.24 no.3
    • /
    • pp.113-120
    • /
    • 2018
  • The one-way gas valve developed in this study was designed to prevent the breakage of packages from increased internal pressure, which is a problem in packaged Kimchi, and simultaneously reduce the outflow of the offodor release. The effect of the one-way gas valve on the headspace atmospheric compositions was investigated in the packaging system. The changes of atmospheric compositions and quality factors of Kimchi, such as $CO_2$ accumulation, pH, titratable acidity, and salinity, were measured during a 4-week storage period at $4^{\circ}C$. The Kimchi package with the one-way gas valve dramatically reduced pressure build-up in the pouch by allowing the controlled flow of gas to the atmosphere. In addition, the package design allows the possibility of controlling the gas generated from Kimchi by adjusting the viscosity of the open pressure control oil. The one-way gas valve did not affect the sensory characteristics of Kimchi products during the storage period. Furthermore, the deodorizing capability of the activated carbon contained in the one-way gas valve effectively reduced the off-odor of Kimchi products released along with carbon dioxide. The novel one-way gas valve is considered to be an active packaging system that can solve major problems of expansion and off-odor leakage in the packaging of Kimchi.

Effect of Exhaust Heat Exchanger on Catalytic Converter Temperature in an SI Engine (가솔린 엔진의 배기 열교환기가 촉매 온도에 미치는 영향에 관한 연구)

  • 이석환;배충식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.2
    • /
    • pp.9-16
    • /
    • 2004
  • Close-coupled catalyst (CCC) can reduce the engine cold-start emissions by utilizing the energy in the exhaust gas. However, in case the engine is operated at high engine speed and load condition, the catalytic converter may be damaged and eventually deactivated by thermal aging. Excess fuel is sometimes supplied intentionally to lower the exhaust gas temperature avoiding the thermal aging. This sacrifices the fuel economy and exhaust emissions. This paper describes the results of an exhaust heat exchanger to lower the exhaust gas temperature mainly under high load conditions. The heat exchanger was installed between the exhaust manifold and the inlet of close-coupled catalytic converter. The exhaust heat exchanger successfully decreased the exhaust gas temperature, which eliminated the requirement of fuel enrichment under high load conditions. However, the cooling of the exhaust gas through the heat exchanger may cause the deterioration of exhaust emissions at cold start due to the increment of catalyst light-off time.

Regeneration of Burner Type Diesel Particulate Trap System Through Active Exhaust Gas Feeding (배기 가스 유량 제어를 이용한 버너방식 디젤 입자상물질 제거 장치의 재생)

  • 김재업;박동선;이만복;김응서
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.1
    • /
    • pp.1-13
    • /
    • 1997
  • The key point that guarantees the durability of the ceramic monolith filter is to lower peak temperature and temperature gradient inside filter during regeneration. The control of the exhaust gas flow rate into the filter, by the bypass technique of the exhaust gas, enables the gas temperature in filter to be constant for regeneration. A couple of methods, which are the ON/OFF and PID control of the bypass valve, were used for feedback control of the gas temperature. These techniques showed that the ceramic filter was regenerated perfectly under the peak temperature and peak temperature gradient limitations for durability.

  • PDF

Study on the Standard Oxygen Transfer Efficiency Monitoring System in the Aeration Tank for Reuse and Discharge of Wastewater (하폐수의 재사용 및 방류를 위한 폭기조 내 표준산소전달 효율 모니터링 시스템에 관한 연구)

  • Kim, Hong-Seok;Kim, Yong-Beom;Ko, Kyung-Han;Kim, Sang-Woo;Shim, Hwan-bo
    • Resources Recycling
    • /
    • v.28 no.6
    • /
    • pp.73-78
    • /
    • 2019
  • In this investigation, off-gas generated from the activated sludge in wastewater treatment plant was monitored. Through monitoring, the oxygen transfer efficiency in the aeration system and the reliability was evaluated by comparing to clean water. First, the dissolved oxygen, oxygen transfer coefficient, and standard oxygen transfer efficiency were measured based on clean water, and the values were 8.60 mg/L, 9.490/hr and 23.96%, respectively. The off-gas monitoring at the wastewater treatment plant indicated that the standard oxygen transfer efficiency was 22.81%. Little difference in oxygen transfer efficiency this data inferred that the performance was improved through diffuser installation in the field monitoring system.

Comparative Study on the Thermal Insulation of Membrane LNG CCS by Heat Transfer Analysis (열전달 해석을 이용한 멤브레인형 LNG 화물창의 단열구조 성능비교)

  • Hwang, Se-Yun;Lee, Jang-Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.1
    • /
    • pp.53-60
    • /
    • 2016
  • This study discusses the thermal insulation capacity of variant of NO96 LNG (liquefied natural gas) cargo containment insulation system. Changing the insulation materials and the insulation layers of conventional GTT NO96 containment system, The thermal resistance and BOR(boil off rate) caused by the heat transfer between cryogenic and environmental temperature is discussed. Therefore, thermal analysis of LNG CCS(cargo containment system) is carried out to determine the insulation capabilities. Also, BOR is evaluated in terms of the total amount of heat invaded into CCS(cargo containment system). Variant of NO96 CCS such as NO96, NO96GW and NO96L3 membrane type during laden voyage is selected for the comparative study. Finite element model for heat transfer analysis is conducted by employing the equivalent thermal resistance model to simplify the complex insulation layers. Finally the results for each variant model are relatively compared and discussed to minimize the BOR.

Study on the Comparison of New and Used Reliquefaction System of Boil-Off-Gas by LNG Cold Energy (냉열을 이용한 LNG 증발기체 BOG 재액화 신공정과 기존공정에 관한 비교연구)

  • Lee, Dong-Hyuck;Jang, Chang-Bong;Jung, Sang-Yong;Kim, Jung-Hwan;Lee, Heon-Seok;Kim, Bum-Su;Ko, Jae-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.1
    • /
    • pp.42-46
    • /
    • 2010
  • BOG(Boil Off Gas) is formed about 0.05 vol%/day from LNG(Liquefied Natural Gas) tanks of LNG receiving terminal. To recycle the BOG using direct contacting, Previously the quantities of LNG and BOG is mixed at the ratio of 11:1 by mass. However simple this process uses, there is the difficulty of processing operation resulted from decrease of using LNG in summer. To complement these shortcomings, Advantages of the process are investigated by comparison of cost and analysis of the indirect contact method using LNG cold energy. It was studied that principles and types of development using LNG cold energy which is abandoned in the carburettor and found how to contact each to find the appropriate cold energy development process. Therefore, in this research, the indirect contact method will be investigated the feasibility of a comparative analysis by using HYSYS.

Characteristics of boil-off-gas partial re-liquefaction systems in LNG ships (LNG선박용 BOG 부분재액화 시스템 특성 연구)

  • Yun, Sang-Kook
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.174-179
    • /
    • 2016
  • To protect the ocean environment, the use of liquefied natural gas (LNG) carriers, bunkering ships, and fueled ships is increasing. Recently, Korean shipbuilders have developed and supplied a partial reliquefaction facility for boil-off-gas (BOG). Despite reasonable insulation, heat leakage in vessel storage tanks causes LNG to be continuously evaporated as BOG. This research analyzed the maximum liquid yield rate for various partial reliquefaction systems (PRS) and considered related factors affecting yields. The results showed a liquid yield of 48.7% from an indirect PRS system (heat exchanges between cold flash gas and compressed natural gas), and 41% from a direct PRS system (BOG is mixed with flash gas and discharged from a liquid-vapor separator). The primary factor affecting liquid yield was heat exchanger effectiveness; the exchanger's efficiency and insulation characteristics directly affect the performance of BOG reliquefaction systems.