• 제목/요약/키워드: Odor unit

검색결과 55건 처리시간 0.021초

축산시설의 축종별 악취물질 농도 특성과 악취도 평가 (Assessment of Odor Characterization and Odor Unit from Livestock Facilities by animals)

  • 장영기;정봉진;김정;송기봉;김호정;유용희
    • 환경영향평가
    • /
    • 제19권1호
    • /
    • pp.29-38
    • /
    • 2010
  • At recent the number of livestock is increased and the size of farm has changed to large facilities in Korea. So the livestock facilities have become one of major sources of odor emission. The purpose of this study is to analyze the concentration and assessment of odor unit from livestock facilities for cow, dairy, swine and poultry. The eleven odor pollutants such as $H_2S$, ($CH_3$)SH, $(CH_3)_2S$, $(CH_3)_2S_2$, $CH_3N$, $NH_3$, $(CH_3)_2N$, $(CH_3)_3N$, butyric acid, valeric acid and isovaleric acid, measured for assessment of the odor concentrations from livestock facility. As the results, it is found that the major matters of odor from livestock facilities were $NH_3$ and $H_2S$. The highest concentration of $NH_3$ is measured as 15 ppm at henhouse and $H_2S$ is measured as 858 ppb at penpig facilities. In the comparison of the average odor unit from livestocks, it is found that the highest odor unit was from swine and the lowest odor unit was from cow facility. So odor unit from swine facilities was 12 to 30 times higher than the odor unit from cow facilities.

다중회귀분석을 이용한 악취 관리지역에서의 복합취기강도와 개별악취물질들의 관계에 대한 연구 (The Relationship Between Odor Unit and Odorous Compounds in Control Areas Using Multiple Regression Analysis)

  • 김종보;정상진
    • 한국환경보건학회지
    • /
    • 제35권3호
    • /
    • pp.191-200
    • /
    • 2009
  • We investigated a trait of odor and the relationship between odor unit and odorous compounds using multiple regression analysis based on data compiled from Sihwa (SIC), Banwol (BIC), Banwol plating (BPIC) and Poseung industrial complex (PIC). These areas are odor control areas in Gyeonggi province. It was revealed that $NH_3$ and styrene concentrations in SIC and BPIC were relatively higher and $H_2S$ concentration especially in mc was more than five times higher than other areas. As a result of regression analysis using SAS, intensity of odor unit was highly related to concentrations of $H_2S$, TMA, styrene and n-valeraldehyde in SIC, $H_2S$, acetaldehyde, and butyraldehyde in BPIC and $NH_3$ in BIC.

창원공단 주요 악취 민원 발생지역 주변 악취발생 현황조사 및 저감방안에 관한 연구 (Measurement of Complex Odor from Industries and Regulated Odorous Substance in Public Complaint Areas of Changwon Industrial Complex, and Its Reduction Countermeasure)

  • 오일환;서정윤;김태형
    • 한국환경과학회지
    • /
    • 제17권5호
    • /
    • pp.525-535
    • /
    • 2008
  • 5 public complaint areas against odor in Changwon Industrial Complex were selected and investigated to clear up the cause of the complaint. 16 companies operated in public complaint areas were visited and had a grip of their situation about odor generation and treatment. Two samples at it's site boundary of each company were taken to measure complex odor unit. Complex odor unit at the site boundary of investigated companies in the public complaint areas, for the most part, exceeded standard(odor unit 20) in industrial area. It was due to that this area was not designated as odor control region and that there are also many problems in current laws of Odor Protection Act, Air Quality Act and regional legislation. Accordingly, It will be necessary to revise the related legislation, to organize governance, to financially support the improvement of environmental facilities and to enforce guidance and the regulation rigidly for the odor emission reduction in Changwon Industrial Complex.

산업단지에서 배출되는 악취원인물질의 규명 (Measurement of odor compounds from odorous emissions source of Industrial Complex)

  • 안상영;최성우
    • 한국환경과학회지
    • /
    • 제14권1호
    • /
    • pp.81-89
    • /
    • 2005
  • As a typical example of simultaneous analysis of the odorous compounds, the volatile organic compounds from inventory sources in Seongseo industrial area were concentrated and analyzed with thermal desorber/GC/MSD, and major malodorous compounds were estimated. Odor intensity and odor concentration was analyzed simultaneously During a period from November in 2002 to December in 2003, this study was conducted to evaluate malodor emission characterization in major treatment facilities. The major components were Dimethyl sulfide, Dimethyl disulfide, Methyl mercaptane, Ammonia, Benzene, Toluene, m,p-xylene, o-xylene, Styrene, 1,2,4­T.M.B and 1,3,5-T.M.B. Among the six major inventory sources, the odor unit concentration of Night-soil disposal facilities was the highest, $669\~2344\;ou/m^{3}.$

반월.시화공단 주변 주거지역의 악취현황 및 황화합물의 체감도 (The Concentrations of Sulfur Compounds and Sensation of Odor in the Residential Area Around Banwol-Sihwa Industrial Complex)

  • 김종보;정상진;송일석
    • 한국대기환경학회지
    • /
    • 제23권2호
    • /
    • pp.147-157
    • /
    • 2007
  • This study was carried out to investigate the characteristics of fourteen odor compounds from a total of 10 sampling sites in residential areas around Banwol-Sihwa industrial complex. The measurement data are analyzed and compared with sensation of odor unit. Only a hydrogen sulfide out of four sulfur compounds was quantified above the detection limit (0.06 ppb) in the residential area around Banwol industrial complex with leather companies and a sewage treatment plant. The concentrations of VOCs were higher than those measured from a big city, and styrene showed the relatively high concentration from all sampling sites ($2.1{\sim}37.8\;ppb$). In the case of carbonyl compounds, acetaldehyde was found most frequently with the mean of 3.97 ppb, and its concentration difference was not significant between Banwol and Sihwa industrial complex. Of the nitrogen compounds, ammonia was measured at the relatively high concentration from all the sampling sites ($12{\sim}707\;ppb$), and a trimethylamine was found at the odor threshold level (0.1 ppb). The concentrations of styrene and ammonia showed relatively seasonal variation, the concentration of styrene in summer was five times higher than that in autumn, the concentration of ammonia in autumn was two times higher than that in summer. However other odorous compounds did not show such strong seasonal variation. Odor-concentration relationship between odor unit and $H_{2}S$ concentrations from industrial sources was examined and used as odor sensation evaluation, and thus the neighbourhood odor complaints maybe caused during the four seasons from the results.

복합악취 농도와 황화수소 농도를 이용한 국내 하수처리시설의 악취발생 특성에 대한 연구 (A Study on Odor Emission Characteristics of Domestic Sewage Treatment Facilities Using Composite Odor Concentration and Hydrogen Sulfide Concentration)

  • 고병철;이종국;이윤수;이민규;감상규
    • 한국환경과학회지
    • /
    • 제21권11호
    • /
    • pp.1379-1388
    • /
    • 2012
  • Odor from sewage treatment plants have the potential to cause significant annoyance and to impact the amenity. In this study, odor emission characteristics at unit process of 48 sewage treatment facilities in 39 plants were evaluated using composite odor concentration and hydrogen sulfide ($H_2S$) concentration. The values of composite odor concentration (geometry mean) and $H_2S$ concentration (median) for sludge treatment processes are higher than those for the other treatment processes. The composite odor concentration and $H_2S$ concentration are distributed over a wide area in each process. Composite odor concentration (dilution ratio) was found to have the significant correlation with $H_2S$ concentration (p=0.000<0.05). The $H_2S$ concentration accounted for 67.1% of composite odor concentration.

수체발산 악취물질 악취단위 산정에 관한 기초실험 (A Fundamental Experiment of Odor Unit Estimation for Water-body Diffuse Odor)

  • 김학민;이범진;김선태
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 1999년도 추계학술대회 논문집
    • /
    • pp.115-116
    • /
    • 1999
  • 대기 중으로 발산되어 인간의 감각기관을 자극함으로써 불쾌감을 유발하고 집중력을 저하시키는 등 일상생활에 좋지 않은 영향을 주는 악취를 객관적으로 평가하기 위해 취기를 감지할 수 있는 최저농도를 평가하는 감지역취(Threshold)의 결정, 냄새가 얼마나 강한가를 평가하는 악취강도(Odor Intensity) 측정, 냄새의 종류를 판단하는 냄새 질(Odor Quality) 판정 등 악취의 성질을 표현하는 여러 방법이 사용되고 있다.(중략)

  • PDF

돈사악취저감을 위한 바이오필터 시스템 개발 - 충전재의 악취제거 특성 - (Development of Biofilter System for Reducing Odor from Livestock Facilities - Odor Reducing Characteristics of Bed Materials -)

  • 한원석;장동일;방승훈;이승주
    • Journal of Biosystems Engineering
    • /
    • 제29권2호
    • /
    • pp.151-158
    • /
    • 2004
  • This research was conducted to study the offensive odor adhesion efficiency of filter bed materials using the experimental column that was designed and constructed in this work. The offensive odor adhesion experiment was conducted using mixture of high physical adhesion efficiency material, and the fixity of deodorization microorganism of selected filter bed material was tested using ammonia exclude microorganism A4-2 and sulfur oxidation microorganism S5-5.2 those were cultured at the Agricultural Chemical Department of Chungnam National University, and deodorization efficiency of selected filter bed material mixture was tested. Followings are summary of these tests results. 1) Amount of elimination of the offensive odor gas ammonia and hydrogen sulfide per unit volume were 0.054 and 0.016 $\ell$/㎤ in rice hull, 0.01 and 0.004 $\ell$/㎤ in rice straw, 0.158 and 0.01 $\ell$/㎤ in coconut, 0.014 and 0.02 $\ell$/㎤ in perlite, 0.004 and 0.003 $\ell$/㎤ in high road ball, and 0.112 and 0.015 $\ell$/㎤ chaff of pine, respectively. 2) Amount of elimination of offensive odor gas of ammonia and hydrogen sulfide per unit vloume were 0.079 and 0.016 $\ell$/㎤ in mixture 1, 0.045 and 0.014 $\ell$/㎤ in mixture 2, 0.123 and 0.017 $\ell$/㎤ in mixture 3, 0.055 and 0.016 $\ell$/㎤ in mixture 4, 0.031 and 0.015 $\ell$/㎤ in mixture 5, and 0.111 and 0.020 $\ell$/㎤ in mixture 6, respectively. 3) The offensive odor elimination microoraganism inoculated to the mixture of chaff of pine (70%) and pert (30%) showed the elimination efficiency of 99.06% and 96.61% against the ammonia and hydrongen sulfide, respectively, during 24 hours period.

한우 및 젖소농장 발생 악취의 확산특성 연구 (A Study on Dispersion Characteristics of Odor from Hanwoo and Dairy Farms)

  • 김두환;하덕민;이재영;김희호;송준익
    • 한국축산시설환경학회지
    • /
    • 제21권1호
    • /
    • pp.1-8
    • /
    • 2015
  • This study was conducted to investigate the dispersion prediction of odor from Hanwoo and dairy farms. Gaussian Plume model used in considering of farm size, wind velocity, atmospheric stability and threshold odor unit to prediction of odor dispersion based on the survey on current state of odor emission and control from 9 site of Hanwoo and 9 site of dairy farms. Farm size, wind velocity and atmospheric stability were affected the distance of odor dispersion, showed longer distance in cases of large farm, low wind velocity and stable atmospheric condition. We will suggestion the adjusted distance of odor dispersion according to farm size was estimated to 50~100 m in Hanwoo farm and 50~150 m in dairy farm when apply the 3OU, 5 m/s wind velocity and stable atmospheric condition.