A CFD Study of Near-field Odor Dispersion around a Cubic Building from Rooftop Emissions

  • Jeong, Sang Jin
    • Asian Journal of Atmospheric Environment
    • /
    • 제11권3호
    • /
    • pp.153-164
    • /
    • 2017
  • Odor dispersion around a cubic building from rooftop odor emissions was investigated using computational fluid dynamics (CFD). The Shear Stress Transport (here after SST) $k-{\omega}$ model in FLUENT CFD code was used to simulate the flow and odor dispersion around a cubic building. The CFD simulations were performed for three different configurations of cubic buildings comprised of one building, two buildings or three buildings. Five test emission rates were assumed as 1000 OU/s, 2000 OU/s, 3000 OU/s, 4000 OU/s and 5000 OU/s, respectively. Experimental data from wind tunnels obtained by previous studies are used to validate the numerical result of an isolated cubic building. The simulated flow and concentration results of neutral stability condition were compared with the wind tunnel experiments. The profile of streamline velocity and concentration simulation results show a reasonable level of agreement with wind tunnel data. In case of a two-building configuration, the result of emission rate 1000 OU/s illustrates the same plume behavior as a one-building configuration. However, the plume tends to the cover rooftop surface and windward facet of a downstream building as the emission rate increases. In case of a three-building configuration, low emission rates (<4000 OU/s) form a similar plume zone to that of a two-building configuration. However, the addition of a third building, with an emission rate of 5000 OU/s, creates a much greater odorous plume zone on the surface of second building in comparison with a two-building configuration.

AUSPLUME 모델을 이용한 악취를 피하기 위한 산업오염원과 주거단지 사이 이격거리에 관한 연구 (A Study on Separation Distance between Industrial Source and Residential Areas to Avoid Odor Annoyance Using AUSPLUME Model)

  • 정상진
    • 한국대기환경학회지
    • /
    • 제18권5호
    • /
    • pp.393-400
    • /
    • 2002
  • Separation distance between industrial source and residential areas to avoid odor annoyance was investigated using AUSPLUME model. A Gaussian plume model (AUSPLUME) for the dispersion was used to calculate odor emission from ground level area source. Using the dispersion model to calculate ambient odor concentrations, the separation distance between industrial source and residental areas was defined by %HA (percentage of highly annoyed person) and odor percentile concentration (C98). The result was compared with the separation distance of various nation guidelines for livestock buildings. The calculated separation distance for industrial source showed similar pattern comparing with various guidelines for livestock buildings.

나방의 성페로몬 감지 (Perception of Sex Pheromone in Moth)

  • 박계청
    • 한국응용곤충학회지
    • /
    • 제61권1호
    • /
    • pp.1-14
    • /
    • 2022
  • 나방은 성페로몬에 대한 통신시스템이 잘 발달되어 있다. 동종의 암컷이 방출하는 성페로몬을 원거리에서 감지하여 암컷을 정확히 찾아가 교미할 수 있도록 하기 위해서, 수컷 나방은 고도로 발달된 성페로몬 감지 시스템을 갖고 있다. 이러한 시스템을 이용해서 수컷 나방은 페로몬 냄새기둥(plume)을 따라 바람을 거슬러 비행하면서 간헐적으로 감지되는 페로몬 냄새가닥(odor filaments)을 추적하는 고정행동양식(stereotypic behavior)을 보인다. 일반적으로 여러 성분으로 구성되는 나방의 암컷 성페로몬은 그 조성이 종특이적(species-specific)이며, 비슷한 성분을 공유하는 유사종들이 방출하는 성페로몬과 동종의 암컷이 방출하는 성페로몬을 정확히 구분하기 위해서 수컷 나방은 촉각에 여러 종류의 고도로 특화된 페로몬 감각세포들을 갖고 있어서, 이들이 페로몬을 감지할 때 나오는 신경 신호들을 종합해서 동종의 페로몬을 인식하여 행동반응이 일어나게 된다. 수컷 나방은 보통 동종의 페로몬 성분뿐만 아니라 유사종이 사용하는 페로몬 성분들을 특이적으로 감지하는 길항적(antagonistic) 냄새감각세포들도 갖고 있어서 페로몬 식별력을 강화한다. 본 종설에서는 지금까지 보고된 수컷 나방의 페로몬 감지 시스템과 이와 연관된 수컷의 감각기 및 행동반응에 대한 연구 결과들을 정리하고, 이를 종합하여 앞으로의 연구 방향을 제시하고자 한다.

한우 및 젖소농장 발생 악취의 확산특성 연구 (A Study on Dispersion Characteristics of Odor from Hanwoo and Dairy Farms)

  • 김두환;하덕민;이재영;김희호;송준익
    • 한국축산시설환경학회지
    • /
    • 제21권1호
    • /
    • pp.1-8
    • /
    • 2015
  • This study was conducted to investigate the dispersion prediction of odor from Hanwoo and dairy farms. Gaussian Plume model used in considering of farm size, wind velocity, atmospheric stability and threshold odor unit to prediction of odor dispersion based on the survey on current state of odor emission and control from 9 site of Hanwoo and 9 site of dairy farms. Farm size, wind velocity and atmospheric stability were affected the distance of odor dispersion, showed longer distance in cases of large farm, low wind velocity and stable atmospheric condition. We will suggestion the adjusted distance of odor dispersion according to farm size was estimated to 50~100 m in Hanwoo farm and 50~150 m in dairy farm when apply the 3OU, 5 m/s wind velocity and stable atmospheric condition.

양돈장 발생 악취의 확산특성 연구 (A Study on Dispersion Characteristics of Odor from Swine Farms)

  • 김두환;하덕민;이인복;최동윤;송준익
    • 한국축산시설환경학회지
    • /
    • 제20권2호
    • /
    • pp.41-48
    • /
    • 2014
  • This study was conducted to investigate the dispersion prediction of odor from swine farms in Korea. Gaussian Plume model used in considering of farm size, wind velocity, atmospheric stability and threshold odor unit to prediction of odor dispersion based on the survey on current state of odor emission and control from 48 site of swine farms. Farm size, wind velocity and atmospheric stability were affected the distance of odor dispersion, showed longer distance in cases of large farm, low wind velocity and stable atmospheric condition. We will suggestion the adjusted distance of odor dispersion according to farm size was estimated to 180 m in small farm and 320 m in large farm when apply the 3 OU, 5 m/s wind velocity and stable atmospheric condition.

냉각탑 백연방지의 성능 향상에 관한 실험적 연구 (An Experimental Study on the Cooling Tower of Plume Prevention and Performance Improvements)

  • 정순영;이병천;김성
    • 한국수소및신에너지학회논문집
    • /
    • 제30권6호
    • /
    • pp.578-584
    • /
    • 2019
  • The occurrence of white plume in the cooling tower is phenomenon that the steam in the air through the cooling tower fan is condensed again by the cold ambient air to become saturated moist air. Accordingly, this can cause many problems like spoiling landscape around the cooling tower, odor of ambient air, falling accident by frozenness in the winter, and traffic accident, etc. This study was to install the heat exchanger in the inside of the cooling tower in order to prevent the white plume phenomenon in the cooling tower without affecting the performance of cooling tower. In addition, this study was to discharge the part of cooling water into the atmosphere through the recirculation of heat exchanger after creating dry air by heating the saturated moist air to the dew point temperature. At that time, this study was to conduct the experimental study in order to secure the optimal design data to prevent the white plume in the cooling tower because it checked the dry·moist temperature and relative humidity in the inside·outside of cooling tower on the moist air, and evaluated the performance of the heat exchanger.