• Title/Summary/Keyword: Odor dispersion

Search Result 23, Processing Time 0.018 seconds

Meteorological Field Generation Method for CALPUFF Model

  • Park, Ji-Hoon;Park, Geun-Yeong
    • Journal of Integrative Natural Science
    • /
    • v.11 no.1
    • /
    • pp.30-38
    • /
    • 2018
  • CALPUFF is one of the recommended air pollution models by EPA with AERMOD. It has been used to simulate the ambient concentration of critical air pollutants as well as non-critical pollutants such as persistent organic matters and the organic materials causing odor. In this model, the air pollutants go through dispersion, transportation, chemical reaction, and deposition process. These mechanisms are significantly influenced by meteorological condition. This study produces the meteorological field in three different methods for the simulation of $SO_2$ using CALPUFF: 1) CALMET model by using both ground-level and aerological observation, 2) CALMET model by using MM5 results with NCEP/NCAR reanalyzed data, 3) CALMET model by using MM5 results in which FDDA is applied with NCEP/NCAR reanalyzed data as well as the meteorological data of Korea Meteorological Administration. As a result of CALPUFF model, the resolved concentration of $SO_2$ showed different behaviors in three cases. For the first case, the fluctuation of SO2 concentration was frequently observed while the fluctuation is reduced in the second and third cases. In addition, the maximum concentration of $SO_2$ in the first case was about 2~3 times higher than the second case, and about 4~6 times higher than the third case. These results can be caused by the accuracy of the resolved meteorological field. It is inferred that the meteorological field of the first case could be less accurate than other two cases. These results show that the use of correct meteorological data can improve the result of dispersion model. Moreover, the contribution of various sources such as point, line, and area sources on the ambient concentration of air pollutant can be roughly estimated from the sensitivity analysis.

An Experimental Study on the Cooling Tower of Plume Prevention and Performance Improvements (냉각탑 백연방지의 성능 향상에 관한 실험적 연구)

  • JEONG, SOON YOUNG;LEE, BYEONG CHEON;KIM, SUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.6
    • /
    • pp.578-584
    • /
    • 2019
  • The occurrence of white plume in the cooling tower is phenomenon that the steam in the air through the cooling tower fan is condensed again by the cold ambient air to become saturated moist air. Accordingly, this can cause many problems like spoiling landscape around the cooling tower, odor of ambient air, falling accident by frozenness in the winter, and traffic accident, etc. This study was to install the heat exchanger in the inside of the cooling tower in order to prevent the white plume phenomenon in the cooling tower without affecting the performance of cooling tower. In addition, this study was to discharge the part of cooling water into the atmosphere through the recirculation of heat exchanger after creating dry air by heating the saturated moist air to the dew point temperature. At that time, this study was to conduct the experimental study in order to secure the optimal design data to prevent the white plume in the cooling tower because it checked the dry·moist temperature and relative humidity in the inside·outside of cooling tower on the moist air, and evaluated the performance of the heat exchanger.

A Status of Atmospheric Environmental Impact Assessment and Future Prospects (대기환경영향평가 현황 및 향후 과제)

  • Koo, Youn-Seo;Choi, Dae-Ryun;Kim, Sung-Tae;Lee, Beom-Ku;Yu, Jung-Min;Lee, Seung-Hoon;Cheong, Chang-Yong;Lim, Jeong-Dae
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.5
    • /
    • pp.581-600
    • /
    • 2013
  • The current status of atmospheric environmental impact assessment (EIA) has been summerized and future prospective for effective and accurate atmospheric EIA has been proposed by reviewing available papers and reports for the atmospheric EIA. The number of reports for the EIA in the EIA support system which is operated by the Korean Environmental Institute have been dramatically decreased from 282 reports in 2008 to 113 reports in 2012 during recent five years. This is partially due to simplification of the EIA procedure, the contraction of the public development and economic recession. We analyzed details of the EIA report to review how actual atmospheric EIA has preformed according to the EIA guidelines from the Korean Ministry of Environment. The 264 reports of EIA published in 2011 and 2012 had been reviewed especially focusing on the atmospheric evaluation items such as meteorology, air quality measurement and modeling, odor measurement and modeling, wind corridor in urban planning, and climate change. In overall sense, the atmospheric EIA has been performed quite well by abiding the guidelines except for local meteorological data measurement, permit standard for air quality and wind corridor. The new approaches to improve the procedure of atmospheric EIA and to reflect future of national air quality standard of $PM_{2.5}$ have been proposed. The guidelines on how to evaluate the wind corridor, to implement atmospheric EIA for $PM_{2.5}$ permit, and how to acquire local meteorological data by combining local measurement and model prediction are required for the effective and future oriented atmospheric EIA.