• 제목/요약/키워드: Odor causing compounds

검색결과 43건 처리시간 0.022초

가지제(加脂劑) 생산공정에서 배출되는 악취원인물질 연구 (The Study of Odor-causing Compounds Emitted from a Stuffing Agent Production Process)

  • 서용수;서정민
    • 한국환경과학회지
    • /
    • 제27권9호
    • /
    • pp.781-788
    • /
    • 2018
  • The volatile odor compounds emitted form a stuffing agent production process were quantified by ATD and GC-MS, and then odor causing compounds were identified by the method of EOI using each TLV. As the results, 72 odor compounds were detected and total concentration was turned up 87.6 ppmv level. In these compounds, aldehyde group is higher 45.49 ppmv than others group, the next is turn up the order of aliphatics, alcohols, esters, ketones. The EOA of aldehyde group show up 101,720 and 97.2%, respectively, the odor causing compounds were identified each of odor 2-Octenal 28.31%, Hexanal 24.06%, Valeraldehyde 16.07%, Butyraldehyde 9.69%, Heptanal 4.97%, Propionaldehyde 4.64%, Acetaldehyde 3.31%. The TLVs of 7 major odor compounds are lower value level of 0.001~0.0001 ppmv, odor causing even in trace level. We need to be concerned with reduction of aldehyde compounds in the odor problem by a stuffing agent production process or ironing process of the textile containing a stuffing agent.

Emission Characteristics of Odors and Odorants Released from Grilling Mackerel and Pork Belly by Different Cooking Tools

  • Kim, Hyun-Jeong;Yu, Mee-Seon;Yang, Sung-Bong
    • 한국환경과학회지
    • /
    • 제23권10호
    • /
    • pp.1763-1773
    • /
    • 2014
  • It is known that mackerel and pork belly release a strong odor in the process of roasting. We evaluated a dilution factor of odor arising during roasting mackerel or pork belly and the relative odor strength using several cooking tools and analyzed compounds causing odors with gas chromatograph/mass detector. Roasting pans used were grill with lid, electric grill without lid and general roasting pan, and a grill with lid can attach the activated carbon charcoal deodorant at the inside of lid. And all electric grills have a drip tray under the heater. We investigated characteristics of odor emission depending on the presence of water and deodorants in these cooking tools. Study has shown that roasting mackerel produces approximately 36 time more odors than roasting pork belly, and the reduced odor emission when roast with water. And it shows the reduced deodorant effect when cooked with water after attaching activated carbon charcoal in the cooking pan. Major odor causing compounds arising when cooking mackerel and pork belly were aldehydes with high boiling point such as octyl aldehyde with a low odor threshold value.

부영양호 원수의 냄새유발 물질 탈기 특성 (Air stripping of odor causing materials from eutrophic lake water)

  • 박노백;송용효;나광주;박상민;전항배
    • 상하수도학회지
    • /
    • 제22권5호
    • /
    • pp.523-529
    • /
    • 2008
  • Algal blooms in a local eutrophic lake often produces the musty and earthy taste & odor problems. Since the odor causing compounds(OCCs) including geosmin and 2-MIB have their own volatility, the OCCs can be removed from water by air stripping methods. Removal of TON(threshold odor number) as an index for OCCs could be fitted well with the first order equations($R^2=0.9$ above), where the air stripping coefficient of TON, k was in the range between 0.0055 and 0.0097 according to the aeration time. k within 30min aeration tests was 0.0097, while it was 0.0055 where the aeration time extended to 150min. With 15 mg/L of PAC, removal of TON was not simulated with 1st order equation within 30min aeration. Within 30min aeration, OCCs rather than geosmin and/or 2-MIB could be removed easily by air stripping or PAC adsorption, while OCCs such as geosmin and/or 2-MIB could be removed slowly by air stripping after 30min aeration. Geosmin and 2-MIB were not readily removed by air stripping(k of them were 0.0018~0.0047 and 0.0018~0.0034, respectively at different air flow rates). Geosmin could be removed by air stripping a little better than 2-MIB.

합류식 하수도의 악취발생 실태 연구 (Investigation of odor Release from Combined Sewer)

  • 길경익;신건철;임지열
    • 한국방재학회 논문집
    • /
    • 제10권6호
    • /
    • pp.185-191
    • /
    • 2010
  • 본 연구에서는 합류식 하수도에서 발생하는 악취에 대해 연구하였다. 도심 지역 합류식 하수도와 합류식 하수도 주요 악취 발생 시설로 나누어 연구를 진행 하였다. 각 각에 대해 특징을 갖는 지역을 선정하여 모니터링을 실시하였다. 도심 지역 합류식 하수도의 경우 황화합물에 대한 실시간 모니터링과 더불어 복합악취 분석을 하였다. 도심 지역의 합류식 하수도 악취는 이동 유동 인구의 변화와 정화조 유출수에 영향을 받았다. 합류식 하수도 주요 악취 발생 시설의 경우 정화조 유출수의 영향이 큰 것으로 나타났다. 합류식 하수도의 주요 악취 유발 물질은 황화수소와 메틸머캅탄 등의 황화합물로판명되었다. 합류식 하수도의 악취 저감을 위해서는 정화조 유출수에 대한 개선 및 황화합물 발생 억제를 위한 대책이 필요할 것이라 판단된다.

남강의 수중보에서 발생하는 이취미 물질에 관한 연구 (A Study on Odor and Taste from Nam River)

  • 이춘식;박현건
    • 한국환경과학회지
    • /
    • 제11권4호
    • /
    • pp.399-403
    • /
    • 2002
  • This study was designed to analyse the odor from Nam river. The characteristic odor in the water occurred from geosmin and phenol, p-cresol and indol were detected from sediment/water samples. The others were detected as alcohols and fat acid compounds. Algae causing odor and taste were identified as Oscillatoria sp. and Synedra acus. 15 species of phytoplankton, a zooplankton, an eelworm and chironomus were identified in water/sediment sample.

차량 내 미생물에 의해 생성되는 악취유발 화학물질의 분석 (Determination of Malodor-causing Chemicals Produced by Microorganisms Inside Automobile)

  • 박상준;김의용
    • KSBB Journal
    • /
    • 제29권2호
    • /
    • pp.118-123
    • /
    • 2014
  • It was confirmed that malodor connected with an air-conditioner in an automobile is caused by microbial volatile organic compounds (MVOCs) produced by microorganisms getting into an air-conditioner when it is operating. Chemicals such as hydrogen sulfide, dimethyl sulfide, nbutyric acid, n-valeric acid, iso-valeric acid, n-octanol and toluene were detected above the odor threshold inside the automobile. The characteristics of a funky odor in the air blown into the automobile were due to detected sulfur compounds (hydrogen sulfide and dimethyl sulfide). Dimethyl sulfide was produced by microorganisms such as Aspergillus versicolor, Methylobacterium aquaticum, Herbaspirillum sp. and Acidovorax sp. In addition, the characteristics of a sour odor in the air blown into the automobile were due to detected organic acids (n-butyric acid, n-valeric acid and iso-valeric acid). N-valeric acid and iso-valeric acid were generated from Aspergillus versicolor, while iso-valeric acid was produced by Methylobacterium aquaticum. In addition, the odor intensity of the air blown into the automobile was affected by the concentration of detected sulfur compounds and organic acids. On the other hand, it is estimated that chemicals such as hydrogen sulfide, n-octanol and n-butyric acid detected in the air blown into the automobile were produced by non-identified species of microorganisms.

양돈 분뇨의 악취특성 및 문제 해결을 위한 환경개선제 사용 현황 및 전망 (Current Status and Perspectives of Livestock Environment Improving Agents for the Characteristics and Control of Swine Manure Odor)

  • 이은영;임정수
    • 한국미생물·생명공학회지
    • /
    • 제38권3호
    • /
    • pp.244-254
    • /
    • 2010
  • The trend toward intensification of livestock raising, confinement in barn has increased in recent days. The move toward concentrated animal feeding operations reduces per unit costs and permits farmers to better earnings in spite of fluctuation in hog prices. However, this also results in outbreaks of a lot of animal wastes and odorous compounds. Emissions of these malodorous compounds produced from concentrated animal feeding operations have become a concern for both public and regulatory agencies and are causing the complaints of residents in rural area. For competitive sustainable swine production industry, odor management plans systematically identify potential odor sources, determine control strategies to reduce these odors, and establish criteria for implementing these strategies. Since, the malodor originates from microbial activities involving a variety of microbes, understanding the characteristics of the microflora present in swine manure is essential for developing effective odor control techniques. This paper reviews the available information in the literature related to the types of bacteria in swine manure, the potential odorous compounds associated with different bacterial genera, and the corresponding techniques used to control odor based on microbiological principles.

악취기여도평가를 이용한 악취원인물질 연구 - 오창과학산업단지를 중심으로 - (A Study on the Odor Compounds Emitted using Odor Contribution Analysis - Focus on the Ochang Scientific Industrial Complex Area -)

  • 정지선;김덕철;이한철;연승원;연익준
    • 한국환경과학회지
    • /
    • 제25권9호
    • /
    • pp.1329-1339
    • /
    • 2016
  • The purpose of this study was to obtain the basic data needed to identify the impact of the odor, emitted from the Ochang Scientific Industrial Complex area on the surrounding residential areas by measuring and confirming odor compounds. The analysis showed that complex odors were diluted from around 4 to 1. The offensive odor measurement results showed that among the sites, site 1 was highest in sulfur compounds, site 2 was highest in toluene, site 3 was highest in trimethylamine, and site 4 was highest in buthylaldehyde. It cannot be decided to be odor-causing compounds for higher odor concentration because each odor substance has a different odor threshold value. According to the odor contribution analysis for each site, site 1, site 2, and site 4 contained high buthylaldehyde concentrations, and site 3 had a high level of trimethylamine. It could be determined that highly evaluated substances were main causes to result in substance for each site.

분말활성탄 흡착 및 탈기에 의한 이취미 제거 (Removal of Taste and Odor by Powdered Activated Carbon Adsorption and Air Stripping)

  • 전항배;나광주;서태경;박상민
    • 상하수도학회지
    • /
    • 제22권4호
    • /
    • pp.455-460
    • /
    • 2008
  • Powered activated carbon(PAC) has been widely applied for controling odor causing compounds(OCCs) from water treatment plants. Because of their volatility, the OCCs can also be removed from water by air stripping methods. In this study, OCCs removal was tested with PAC adsorption, air stripping, and both PAC adsorption and air stripping from the Taecheong lake water. Removal efficiency of OCCs in terms of threshold odor number(TON) were 39.6% by both PAC (15mg/L) adsorption and aeration for 30 min, 33.6% by PAC(15mg/L) adsorption alone for 30 min, and 22.9% by aeration alone for 30 min, respectively. OCCs could be removed up to 50% by aeration for 120 min without PAC adsorption. At an extended aeration with 15mg/L of PAC, OCCs removal occurred mainly by PAC adsorption within 30 min aeration while it continued by air stripping afterward. At simulated jar tests with the raw water, removal efficiencies of geosmin and MIB were 48.3, 36.1% by coagulation and sedimentation without PAC addition. With 15mg/L of PAC on the same jar tests, the removal efficiencies were 83.1, 60.1%, respectively. Without PAC, OCCs could be possibly removed by stripping during the agitation processes.

음식물류폐기물 처리시설에서의 악취발생 특성 및 관리방안 (The Characteristic and Management of Odor Emitted from Foodwaste Treatment Facility)

  • 유승성;김영두;이준연;차영섭;김은숙;전재식;선우영;엄석원;채영주
    • 환경영향평가
    • /
    • 제21권3호
    • /
    • pp.353-365
    • /
    • 2012
  • This study is understanding characteristics and analyzing contributions of the odor causing compounds of complex-odor & major specified odor materials, and contribution analysis, caused pre-treatment facilities(input and storage) and post-treatment facilities(heating and drying). The target of this study is feeds-production-facilities, located in Seoul. The averaged complex-odor compounds on the boundary line is 21 times higher, and it is 15 times higher than emission standards. In cracking&collection(pre-treatment facilities), the concentration of compounds is 4,881 times, 2,080 times in drying, and 1,442 times in putting&storing facilities. Ammonia occupies the largest portion of the results of monitoring specified odor compounds in input&storage facilities, followed Acetaldehyde > Hydrogen sulfide > Methyl mercaptan. In cracking&collection, Ammonia also occupies most of odor compounds, followed Methyl mercaptan > Acetaldehyde > Dimethyl disulfide > Dimethyl sulfide > Hydrogen sulfide. Acetaldehyde > Methyl mercaptan in drying facilities. On the boundary line, however, the concentration of specified odor compounds stays below emission standards. The result of contribution analysis is that methyl mercaptan has the highest contribution in input & storage, as well as cracking&collection facilities, followed Acetaldehyde > Hydrogen sulfide > Dimethyl sulfide > Dimethyl disulfide. In the drying facilities, the contribution shows Methyl mercaptan > Acetaldehyde > i-Valeraldehyde and Butyraldehyde. Therefore, to decrease odor in foodwaste treatment facilities, proper prevention facilities need to be installed and operated, according to characteristics of individual odor compounds, based on monitored data.