• Title/Summary/Keyword: Odor Removing Efficiency

Search Result 20, Processing Time 0.027 seconds

Development of an Odor Abatement System for Swine Manure Treatment Facilities

  • Lee, S.H.;Yun, N.K.;Kim, G.W.;Yum, S.H.;Cho, Y.H.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • This study was conducted to solve the problem of public grievance owing to odor of a pig farm. Odor emissions from pig production systems mainly originate from liquid manure storage and solid manure fermentation. The low-cost odor abatement system (OAS) for application at liquid manure storage tank and solid manure fermentation facilities was developed in this study. The OAS adapted odor removing principles of a biofilter and biotrickling filter. The OAS is very simplified in structure. The appearance of the OAS had a form of cylindrical or cubical shape. The system performance was monitored for about one year after stabilization. A 7 seconds empty bed contact time for the OAS was adapted to achieve the odor reduction levels. The commercial type of OAS was constructed with media comprised of wood chips. Moisture content always remained above 50% wet basis. Average ammonia removal efficiency for the developed design was 89% at the liquid manure storage tank. Also, the removal efficiency at a solid manure fermentation facility was 86% on ammonia.

  • PDF

Removal of Odor and THM from the Raw Water of Daecheong Dam (대청호 원수내 냄새 및 THM 제거방안 연구)

  • Jeon, Hang-Bae;Yun, Gi-Sik
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.3
    • /
    • pp.235-245
    • /
    • 1997
  • A pilot scale study for removing odor and trihalomethane formation potential (THMFP) was investigated in the standard water treatment plant equipped with ozone oxidation and granular activated carbon (GAC) adsorption processes. The removal efficiency of dissolved organic carbon (DOC) in the pilot scale standard water treatment process (PSWTP) was about 25%, however, no more removal in the ozone oxidation process. On a GAC after 30 days operation, DOC removal efficiency was about 75%. Odor removal efficiency was about 30% in PSWTP, 60% in ozone oxidation, and almost complete in well as DOC. Mid-1 and 2 that showed breakthrough in odor inducing material as well as DOC. Mid-1 and 2 chlorination was able to reduce trihalomethanes (THM) by 25% compared to prechloringation, while postchlorination alone could reduce them by 30%.

  • PDF

Removal of Alkali Odors using Impregnated ACFs (첨착 ACF를 이용한 염기성 악취물질의 제거)

  • 김기환;김덕기;최봉각;신창섭
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.1
    • /
    • pp.92-97
    • /
    • 1998
  • Malodorous gases give discomfort and harm to laborers and residential neighborhoods and therefore, the removing odor materials emitted from plants and industrial facilities is important subject. The main ingredients of alkali odor are $NH_3$ and $CE_3SH$. The adsorption characteristics of odors were studied using four different activated carbon fibers(ACF) and active carbon(AC). Alkali odor was removed by using ACF impregnated with $H_3PO_4$ and $H_2SO_4$ and treated with $HNO_3$ and NaOH. The experimental result showed that ACF has a higher removal efficiency than AC. The adsorption capacity was increased with the impregnation and surface treatment, and $H_2SO_4$ was the best impregnant for the removal of alkali odor.

  • PDF

System Development of Removing Dust and Odor from Manufacturing Process of FRP Products (FRP제품 가공시 발생하는 분진 및 악취 제거 시스템 개발)

  • Yun, Huy Kwan;Kim, Jae Yong
    • Applied Chemistry for Engineering
    • /
    • v.20 no.5
    • /
    • pp.547-552
    • /
    • 2009
  • When fiber reinforced plastics (FRP) products are manufactured, dust and odor materials are inevitably generated in a workplace. To improve the bad condition of the workshop, we developed the Hybrid Bag Filter attached activated carbon fiber (ACF) and installed the system at two companies producing FRP goods. In order to raise the efficiency of dust collection, we set the ducts both on the ceiling and at the bottom of the wall and according to the circumstances of the workshop's space, moving dust collector also adopted as a different type of flexible duct. Pulse Jet Type Bag Filter is also equipped to operate the system more effectively, for the improved fine environment because of high dust removal efficiency. Finally, we investigated the removal tendency of the dust and odor when operating the System of Hybrid Bag Filter.

System Development for Removing Dust & Odor from Manufacturing Process of Resin Products (I) (수지제품 가공시 발생하는 분진 및 악취 제거 시스템 개발(I))

  • Yun, Huy-Kwan;Kim, Jae Yong
    • Applied Chemistry for Engineering
    • /
    • v.20 no.2
    • /
    • pp.218-222
    • /
    • 2009
  • As we look into the related technologies at home and abroad, the odor and dust removal technologies did not make us satisfied because its removal method is not appropriate and its economical efficiency was low. If bad odor and dust were generated simultaneously, we should install two removal factories separately, and it made a big problem. Consequently, we investigated to obtain the related basic information for a new hybrid bag filter system which can remove both odor and dust at the same time, using bag filter with ACF (dual filter type).

Effectiveness of elimination inflowing algae in water treatment plant using natural algae remover (천연 조류 제거제를 이용한 정수장 유입 조류 제거 효율)

  • Jung, Hoyoung;Kim, Younghee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.4
    • /
    • pp.311-319
    • /
    • 2019
  • The purpose of this study was to analyze water treatment characteristics, including the efficiency of removing algae from water purification plants, by installing a demonstration facility for decontamination of algae, including natural algae remover injection equipment, in the water purification plant. Jar-test showed that the optimum injection of natural decontaminant was 20 mg/L. Of the water contaminant treatment efficiency of the intake and water purification plants, Chl-a averaged 74.0% elimination efficiency from $5.0mg/m^3$ to $1.3mg/m^3$ and the maximum treatment efficiency was 91.5% removal efficiency when the inflow concentration of Chl-a was $11.8mg/m^3$. In addition, 51.2% and 47.1% of the taste and odor indicator items, geosmin and 2-MIB, resulted from the overgrowth and decaying of algae, respectively, to identify toxic substances and odor reduction effects. In addition, elimination efficiencies of SS and Turbidity materials were higher than 70.0%. In the injection of natural algae remover, no effects such as sudden changes in water quality due to secondary reactions were found, and appropriate levels were maintained under water treatment conditions.

Study of Smoking Booth Design for the Treatment of Hazardous Pollutants (유해오염물질 처리를 위한 흡연부스의 설계)

  • Kwon, Woo-Taeg;Kwon, Lee-Seung;Lee, Woo-Sik
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.107-111
    • /
    • 2017
  • The purpose of this study was to develop a Eco smoking booth that can effectively reduce hazardous pollutants generated during smoking and evaluate the efficiency and effectiveness of removing hazardous pollutants. The design and manufacture of an eco-friendly automatic smoking booth equipped with deodorizing facilities, such as inlet - HEPA filter - electrostatic precipitator (EP) - impregnated activated carbon - exhaust port, etc., and the efficiency of removing hazardous pollutants from inside and outside was measured and evaluated. The complex odor removal efficiency was 95.37% inside the smoking booth, and 97.38% at the exit of the preventive facility. The carbon monoxide removal efficiency was 94.25% in the inside and 98.32% in the outlet. In addition, the removal efficiency of particulate matter, (PM1, PM2.5, and PM10) inside the smoking booth was 98.59%, and 98.85% at the outlet. The total volatile organic compounds (TVOCs) decreased from $26,000{\mu}g/m^3$ to $5,203{\mu}g/m^3$ in the smoking booth, resulting in 79.99% removal efficiency. After the ventilator was operated, the measured effluent concentration was $5,019{\mu}g/m^3$, and the removal efficiency was 80.70%. Therefore, the smoking booth designed and manufactured through this study can be applied to the removal of harmful pollutants even in the small working environment in the future.

Evaluation on the Locations of Powdered Activated Carbon Addition for Improvement of Taste and Odor Removal in Drinking Water Supplies (상수원수 내 이취미 제거효율 향상을 위한 분말활성탄 투입지점의 평가)

  • Kim, Young-Il;Lee, Sang-Jin;Bae, Byung-Uk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.3
    • /
    • pp.341-348
    • /
    • 2007
  • The efficiency of powdered activated carbon (PAC) for removing taste and odor (T&O) in drinking water supplies is dependent on the contact time, quality of mixing, and the presence of competing compounds. All of these are strongly influenced by the stage in the treatment process at which the PAC is added. In conventional water treatment plants (WTPs), PAC is commonly added into the rapid mixing basin where chemicals such as coagulants, alkaline chemicals, and chlorine, are simultaneously applied. In order to prevent interference between PAC and other water treatment chemicals, alternative locations for addition of PAC, such as at transmission pipe in the water intake tower or into a separated PAC contactor, were investigated. Whatever the location, addition of PAC apart from other water treatment chemicals was more effective for geosmin removal than simultaneous addition. Among several combinations, the sequence 'chlorine-PAC-coagulant' produced the best result with respect to geosmin removal efficiency. Consequently, when PAC has to be applied to cope with T&O problems in conventional WTPs, it is very important to prevent interference with other water treatment chemicals, such as chlorine and coagulant. Adequate contact time should also be given for adsorption of the T&O compounds onto the PAC. To satisfy these conditions, installation of a separated PAC contactor would be the superior alternative if there is space available in the WTP. If necessary, PAC could be added at transmission pipe in the water intake tower and still provide some benefit for T&O treatment.

Isolation and Identification of Bacteria Removing Sulfur Compound Odor (황 화합물계 악취 제거 미생물의 분리 및 동정)

  • 김진수;유용규;이상섭
    • Korean Journal of Microbiology
    • /
    • v.40 no.2
    • /
    • pp.127-132
    • /
    • 2004
  • We isolated 50 strains from sludge of wastewater treatment aeration tank using selective medium for Thio-bacillus sp. by membrane filtration method. They were identified as Thiobacillus neapolitanus (7), T. tepidarius (4), T. dientrificans (5), T. versutus (23), T. intermedius (2) and T. perometabolis (9). We selected Thiobacillus versutus strain KT51, which had the highest removal efficiency (100%) of hydrogen sulfide and the highest removal efficiency (85%) of dimethyl sulfide for 30 min in screen test. Also Thiobacillus versutus strain KT81 had the highest removal efficiency (26%) of dimethyl disulfide for 30 min in screen test. In applification of lab-scale reactor (closed-biological treatment) using Thiobacillus versutus strain KT51, results were 99.8% (<0.02 ppm) removal efficiency of hydrogen sulfide for 15 min.

A Study on Adsorption Characteristics of Natural Organic Matter and Taste & Odor Using Activated Carbon (활성탄 흡착지에서 응집조건에 따른 자연유기물질과 이·취미(Geosmin, 2-MIB) 파과특성에 관한 연구)

  • Kim, Sung-Jin;Hong, Seong-Ho;Shin, Heung-Sup
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.1
    • /
    • pp.91-99
    • /
    • 2007
  • It is well-known that the presence of NOM (natural organic matter) in water has a negative effect on removing taste and odor compounds by activated carbon adsorption. Therefore, various means such as enhanced coagulation are applied to reduce the NOM. The presence of taste & odor compounds in drinking water even parts per trillion, is enough to generate customer dissatisfaction. Therefore, the aim of this study was to evaluate carbon usage rate (CUR) for conventional coagulation (CC) and enhanced coagulation (EC) in order to improve the efficiency of adsorption of taste and odor compounds. Also, Effect of CC and EC on molecular weight fraction and the early stage breakthrough of 2-MIB and Geosmin are evaluated. When the enhanced coagulation was adapted for pretreatment for activated carbon adsorption the operation period could be prolonged by 3.5~4 times. CUR for CC was about 2 times greater than CUR for EC and this means that EC has more adsorption capacity than CC. To analyze effect of EC and CC on breakthrough of 2-MIB quantitatively, adsorbed NOM mass was calculated based on unit mass of activated carbon. In the early stage breakthrough of 2-MIB, total adsorbed NOM was 23.72mg/g for CC and 34.56mg/g for EC. Therefore, it is shown that the early breakthrough term of 2-MIB and Geosmin was improved due to increased adsorbability. The low-molecular-weight NOM (500~2000Da) compounds were the most competitive, participating in direct competition with 2-MIB for adsorption site.