• Title/Summary/Keyword: Odontoid fracture

Search Result 18, Processing Time 0.023 seconds

Biomechanical Comparison of Inter-fragmentary Compression Pressures : Lag Screw versus Herbert Screw for Anterior Odontoid Screw Fixation

  • Park, Jin-Woo;Kim, Kyoung-Tae;Sung, Joo-Kyung;Park, Seong-Hyun;Seong, Ki-Woong;Cho, Dae-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.5
    • /
    • pp.498-503
    • /
    • 2017
  • Objective : The purpose of the present study was to compare inter-fragmentary compression pressures after fixation of a simulated type II odontoid fracture with the headless compression Herbert screw and a half threaded cannulated lag screw. Methods : We compared inter-fragmentary compression pressures between 40- and 45-mm long 4.5-mm Herbert screws (n=8 and n=9, respectively) and 40- and 45-mm long 4.0-mm cannulated lag screws (n=7 and n=10, respectively) after insertion into rigid polyurethane foam test blocks (Sawbones, Vashon, WA, USA). A washer load cell was placed between the two segments of test blocks to measure the compression force. Because the total length of each foam block was 42 mm, the 40-mm screws were embedded in the cancellous foam, while the 45-mm screws penetrated the denser cortical foam at the bottom. This enabled us to compare inter-fragmentary compression pressures as they are affected by the penetration of the apical dens tip by the screws. Results : The mean compression pressures of the 40- and 45-mm long cannulated lag screws were $50.48{\pm}1.20N$ and $53.88{\pm}1.02N$, respectively, which was not statistically significant (p=0.0551). The mean compression pressures of the 40-mm long Herbert screw was $52.82{\pm}2.17N$, and was not statistically significant compared with the 40-mm long cannulated lag screw (p=0.3679). However, 45-mm Herbert screw had significantly higher mean compression pressure ($60.68{\pm}2.03N$) than both the 45-mm cannulated lag screw and the 40-mm Herbert screw (p=0.0049 and p=0.0246, respectively). Conclusion : Our results showed that inter-fragmentary compression pressures of the Herbert screw were significantly increased when the screw tip penetrated the opposite dens cortical foam. This can support the generally recommended surgical technique that, in order to facilitate maximal reduction of the fracture gap using anterior odontoid screws, it is essential to penetrate the apical dens tip with the screw.

Rod Migration into the Posterior Fossa after Harms Operation : Case Report and Review of Literatures

  • Chun, Hyoung-Joon;Bak, Koang-Hum;Kang, Tae-Hoon;Yi, Hyeong-Joong
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.3
    • /
    • pp.221-223
    • /
    • 2010
  • C1 lateral mass and C2 pedicle (C1LM-C2P) fixation is a relatively new technique for atlantoaxial stabilization. Complications from C1LM-C2P fixation have been rarely reported. The authors report unilateral rod migration into the posterior fossa as a rare complication after this posterior C1-C2 stabilization technique. A 23-year-old man suffered severe head trauma and cervical spine injury after vehicle accident. He was unconscious for 2 months and regained consciousness. He underwent C1LM-C2P fixation for stabilization of type II odontoid process fracture described by Harms. The patient recovered without a major complication. Twenty months after operation, brain computed tomogram performed at psychology department for disability evaluation showed rod migration into the right cerebellar hemisphere. The patient had mild occipital headache and dizziness only regarding the misplaced rod. He refused further operation for rod removal. To our knowledge, this complication is the first report regarding rod migration after Harms method. We should be kept in mind the possibility of rod migration, and C1LM-C2P fixation should be performed with meticulous technique and long-term follow-up.

Posterior C1-2 Transarticular Screw Fixation without C1-2 Sublaminar Wiring in Atlantoaxial Instability (제 1, 2 경추간 판하철사고정술 없는 후방 경관절 나사못 고정술 및 골유합술)

  • Shin, Yong Hwan;Hwang, Jeong Hyun;Sung, Joo Kyung;Hwang, Sung Kyu;Hamm, In Suk;Park, Yeun Mook;Kim, Seung Lae
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.11
    • /
    • pp.1469-1475
    • /
    • 2000
  • Objective : The goal of this study was to evaluate the clinical outcome of the posterior C1-2 transarticular screw fixation without C1-2 sublaminar wiring in atlantoaxial instability. Methods : Between Apr. 1995 and Feb. 2000, we used this technique in treat randomly selected 17 patients (11 men, 6 women) who had atlantoaxial instability. The causes of instability were : type II-A odontoid process fracture(10 cases) ; type II-P odontoid process fracture(1 case) ; Os odontoideum(2 cases) ; transverse ligament laxity due to rheumatoid disease(1 case) ; and, transverse ligament injury without bone fracture(3 cases). All cases were operated with posterior C1-2 transarticular screw fixation with 3.5mm cortical screw and interlaminar iliac graft without sublaminar wire fixation. The mean follow-up period was 28 months(5 to 58 months) and the mean age at the time of operation was 41 years(15 to 68 years). All Patients were allowed to ambulate with Philadelphia neck collar on the first post-operation day. Results : Bony fusion was successfully achieved in all cases demonstrated at 3-month follow-up studies. There was no operative mortality or morbidity. Conclusion : The authors conclude that the posterior transarticular screw fixation without C1-2 sublaminar wiring provide adequate stability with high bony union rate in atlantoaxial instability of various causes.

  • PDF

Cervical Fibrous Dysplasia Presenting as a Pathologic Fracture in an Older Patient

  • Lee, Su-Heon;Han, In-Ho;Kang, Dong-Wan;Choi, Byung-Kwan
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.2
    • /
    • pp.139-142
    • /
    • 2011
  • Vertebral involvement of fibrous dysplasia (FD) is rare, especially in the cervical spine. Moreover, cervical FD presenting as a pathologic fracture in older patients is extremely rare. We report a case of symptomatic cervical FD associated with pathologic fracture in a 63-year-old man. The patient presented with progressive weakness of the left arm and pain in the shoulder and arm. Radiologic studies revealed a collapsed and typical 'ground glass' radiolucency of C4. Multiple lytic lesions involved the odontoid process of C2 and the body, left pedicle, and posterior elements of C4. Combined anterior and posterior decompression and reconstruction were performed. Post-operatively, the histopathologic examination confirmed FD. On the post-operative follow-up examination, the neurologic deficits had completely resolved.

Conservative Management for a Highly Displaced Dens Fracture in a Two-Year-Old Child (2세 유아에서 발생한 고도 전위성 치상돌기 골절의 보존적 치료)

  • Lim, Sung Joon;Kim, Geon Jung;Kim, Yong Min
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.6
    • /
    • pp.530-534
    • /
    • 2021
  • Fractures of the dens (odontoid process) in children's cervical spine are rare, with very few case reports dealing with these injuries. In particular, a treatment modality has not been established for severe displaced fractures. Surgical fixation can theoretically afford early reduction and better maintenance, but it requires a very delicate and cautious procedure and results in permanent fusion of 1-2 cervical articulation. The authors chose conservative management for a displaced dens fracture in a two-year-old toddler and achieved a promising result. We report this case with a review of the relevant literature.

The Results and Complications of the C1-C2 Transarticular Screw Fixation Methods (축추-환추간 경관절 나사못 고정술 치료의 결과 및 합병증)

  • Choi, Jun-Woong;Yoon, Seung-Hwan;Park, Hyung-Chun;Park, Hyeon-Seon;Kim, Eun-Young;Ha, Yoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.3
    • /
    • pp.201-206
    • /
    • 2005
  • Objective: To evaluate the accuracy and safety of C1-C2 transarticular screw insertion, we retrospectively review surgical records and postoperative radiological findings. Methods: From January 2001 to October 2003, the C1-C2 transarticular screw fixation and posterior wiring with iliac bone grafts was performed in 16 patients. 6 patients had rheumatoid arthritis which caused cervical instability, 3 patients had os odontoideum, 3 patients had type 2 odontoid process fracture, 3 patients had traumatic transverse ligament injury and 1 patients who had been managed with C1-C2 wire fixation had psoriatic arthritis. Results: Osseous fusion was documented in 15 patients(93.8%). Only one patient was recorded screw loosening because of postoperative infection. One patient had only one screw placed because of abnormal anatomical structure, one patients was breakage of a Kirschner wire, and one screw was medial location to lateral mass of C1, but clinical results was excellent and radiological instability was not noted. Conclusion: The author's experience demonstrates that C1-C2 transarticular screw fixation with wired bone graft is a safe procedure with higher fusion rate but precaution is needed to avoid the neural damage, vertebral artery injury, and hardware failure.

The Cervical Spinal Fractures: Comparison of the Sites and Incidences According to the Causes and the Types of the Injuries (경추 골절의 원인과 형태에 따른 위치와 빈도의 비교)

  • Cho, Jae-Ho;Cho, Kil-Ho;Byun, Woo-Mock;Kim, Sun-Yong;Park, Bok-Hwan
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.1
    • /
    • pp.114-126
    • /
    • 1993
  • The fractures of the cervical spine are relatively uncommon, but they may cause serious neurologic deficits temporarily or permanently. So, it is very important to treat the patients early by way of exact evaluation for the sites and the mechanisms of the injuries. The authors reviewed retrospectively 188 cervical spinal fractures in 100 patients from Sep. 1984 to Aug. 1990. Commonly involved levels were $C_5$ and $C_6$ in lower cervical level and $C_2$ in upper cervical level and the sites in each spine were body, lamina and odontoid process. The hyperflexion injury was the most common type of the cervical spinal fractures occupying 53% of all cervical fractures and cause more multiple fractures(2.26 fractures/patient) than in hyperextension(1.68 fractures/patient). In hyperflexion injuries, body, transverse and spinous process were commonly involved but lamina fracture was relatively common in hyperextension injury. The dislocations associated with fractures were developed most commonly in hyperflexion injury and 70% of these were anterior dislocation and the most commonly involved levels were $C_{5-6}$ and $C_{6-7}$. In conclusion, hyperflexion injury needs more close examination for the entire spinal levels than injuries of other mechanisms because it results in more severe fractures with or without dislocation and relatively frequent multiple fractures in different levels.

  • PDF

The Clinical Applicability of Transoral Transpharyngeal Approach to the Craniovertebral Junction Lesions (두개 경추 이행부의 병소에 대한 경구적 접근법의 유용성)

  • Cho, Tae Goo;Park, Kwan;Cho, Yang-Sun;Baek, Chung-Hwan;Nam, Do Hyun;Kim, Jong Soo;Hong, Seung-Chyul;Shin, Hyung Jin;Eoh, Whan;Kim, Jong Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.3
    • /
    • pp.379-388
    • /
    • 2000
  • Objective : Although transoral transpharyngeal approach is a very useful method for the lesions of craniovertebral junction, it is not frequently used because of anatomical unfamilarity, risk of cerebrospinal fluid(CSF) leakage, and resultant postoperative meningitis. To evaluate the usefulness of transoral transpharyngeal approach for various lesions of craniovertebral junction, clinical characteristics and the results of this approach are investigated. Methods : Transoral transpharyngeal approaches were performed in eight cases between 1996 and 1999. Among them, there were three basilar invaginations due to congenital anomalies, two odontoid type I fractures, two atlantoaxial dislocations, and one pseudotumor. Surgical methods included five cases of anterior decompression and posterior fusion, two anterior approaches for decompression and one transoral approach for biopsy. Results : This procedure allowed immediate clinical improvement in all cases. In seven patients with preoperative motor deficit showed a progressive neurological improvement. The follow-up plain x-rays demonstrated successful bony fusion in all patients. Only one patient suffered from postoperative wound dehiscence, but she completely recovered after wound revision. There was no complication of postoperative CSF leakages. Conclusions : Transoral transpharyngeal approach for the ventral lesions of craniovertebral junction, can be used as a relatively simple and effective method.

  • PDF