• Title/Summary/Keyword: Octave Center Frequency

Search Result 22, Processing Time 0.022 seconds

Interior Noise and Low Frequency Noise Characteristics of Busan Metro Line 3 Noise (부산도시철도 3호선 실내소음 및 저주파 소음 특성)

  • Hong, Do-Kwan;Jeong, Jae-Boo;Jung, Seung-Wook;Gang, Hyun-Wook;Ahn, Chan-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.11
    • /
    • pp.1113-1120
    • /
    • 2012
  • This paper deals with the analysis of interior noise and low frequency noise characteristic for the Busan citizens to use public transport, Busan Metro Line 3. The interior noise evaluation index, articulation index(AI) is evaluated the lower value about average 22 % in a whole range, this is difficult to have a conversation. Also, noise criteria(NC) curve is partially evaluated as NC-65 below 2000 Hz, space type is evaluated as factories. Another of interior noise evaluation index, preferred speech interference level(PSIL) is evaluated the upper value about average 66 dB(A) in a whole range, this is evaluated to be interrupted. In the case of low frequency noise(20~200 Hz), the measurement of low frequency noise is assessed largely beyond noise criteria of ISO 226. The low frequency noise should be reduced because low frequency noise affects on psychological stress and displeasure although low frequency noise is not recognized by auditory sense. The low frequency noise criteria and guideline will be enacted from now on in Korea.

Design and Performance Test of Silencers with Ring-shaped Resonators (환형 공명기가 설치된 소음기 설계 및 성능 시험)

  • Kim, Bong-Ki;Kim, Sang-Ryul;Lee, Seong-Hyun;Lee, Jong-Hwa;Lee, Hae-Seong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.4
    • /
    • pp.357-364
    • /
    • 2011
  • In this study, ring-shaped acoustic resonators were proposed to be installed in a silencer to increase the acoustic performance of silencer in the low-frequency range. Evaluation of noise reduction performance of acoustic resonator arrays was carried out by measuring the random-incidence absorption coefficient. It was found that the absorption coefficient of resonator array was measured up to 1 at 125 Hz of 1/3-octave band center frequency. Insertion losses of silencers with ring-shaped acoustic resonator arrays were measured based on ISO 7235. The results were shown that the ring-shaped resonator could increase the insertion loss up to 13 dB without flow, whereas 7 dB when flow speed reached 15 m/s. As increasing the flow speed above 15 m/s, the effect of acoustic resonator decreased due to the effect of nonlinear air damping of the resonator. It was also found that the increment of pressure drop by the presence of resonator arrays was about 9 % at flow speed of 25 m/s.

Sound Characteristics of Sasang Constitutional Type Using PSSC-2004 in the Korean Children (사상체질음성분석기(四象體質音聲分析機)(PSSC-2004)를 이용한 한국인 소아의 체질별(體質別) 음향특성(音響特性))

  • Kim, Hyuk;Yang, Sang-Muk;Shim, Gyu-Heoun;Kim, Dal-Rae;Yoo, Jun-Sang
    • Journal of Sasang Constitutional Medicine
    • /
    • v.18 no.2
    • /
    • pp.55-67
    • /
    • 2006
  • 1. Objective & Method The purpose of this study was to objectify the diagnosis of Sasang constitution. 163 children's voices were analyzed with 74 factors using PSSC-2004. 2. Results (1) In male children group, Taeumin's APQ4 was significantly low compared with the others. (2) In male children group, Taeumin's octave 5 & octave 6 were significantly low compared with the others. It was significant distinction between Taeumin and Soeumin at the result of post hoc. (3) In male children group, Taeumin's Time Domain Total Sum / Time Domain Count & Frequency Domain Total Sum / count(0) were significantly low compared with the others. It was significant distinction between Taeumin and Soeumin at the result of post hoc. (4) In male children group, Taeumin's 0k-2k total sum & 2k-4k total sum were significantly low compared with the others. It was significant for distinction between Taeumin and Soeumin at the result of post hoc. (5) In male children group, Taeumin's 2k-4k deviation was significantly low compared with the others. It was significant distinction between Taeumin and Soeumin at the result of post hoc. (6) In male children group, Taeumin's D# Total Energy & F# Total Energy were significantly low compared with the others. It was significant distinction between Taeumin and Soeumin at the result of post hoc. (7) In male children group, Taeumin's D# deviation & F# deviation were significantly low compared with the others. It was significant distinction between Taeumin and Soeumin at the result of post hoc. (8) In female children group, Soyangin's center frequency (7) was significantly high compared with the others. It was significant distinction between Taeumin and Soyangin at the result of post hoc. 3. Coclusion With these results, we got some information for standardization of the clinical diagnosis guideline of Sasang constitutional type classification using PSSC-2004 in the Korean children

  • PDF

A study of the measurement systems implementation for the interior impulse noise (실내 충격소음 측정시스템 구현에 관한 연구)

  • Song, Kee-Hyeok;Chung, Sung-Hak
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.6
    • /
    • pp.93-100
    • /
    • 2014
  • The objective of this study is to propose the measurement system implementation method for the evaluation and measurement of the indoor-impulsive over 170 dB noise source. For the purpose of measuring impulse noise, design and implementation constructed followed subsystems of the testing center, microphone, ear simulator, head and torso simulator and so on. Measurement systems for the accuracy and reliability of impulse noise are implemented when measuring 3 ways of measurements method by the simultaneous measurement system design. For the accuracy and reliability of three mutually indoor-impulse noise measurements were compared, three kinds of measuring methods in accordance with the peak sound pressure level and octave band. Comparing the results of data, the indoor-impulse noise by analyzing a frequency characteristic was validated in difference for the statistical significance. Result are determined by the influence of the reflected wave. Therefore, the flexible size of the interior test site while interior impulse noise measurement system was constructed. Throughout this system can be affected by parameters that are the impulse noise source and the corresponding frequency-characteristic analysis to determine the spectrum of the reflected wave. And, in the near future, indoor impulse noise measurement systems for acquisition and analysis are utilized in useful data.

Analysis of Dependence on Wind Speed and Ship Traffic of Underwater Ambient Noise at Shallow Sea Surrounding the Korean Peninsula (한반도 주변해역 수중배경소음의 풍속과 선박분포에 따른 의존성 분석)

  • 최복경;김봉채;김철수;김병남
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.233-241
    • /
    • 2003
  • It is statistically analyzed the underwater ambient noise measured at 13 sites less than 200 m deep in the shallow water surrounding the Korean Peninsula for 9 yews from 1990 to 1998 in various environmental conditions. Frequency spectra were obtained with the 1/3-octave band center frequencies from 25㎐ to 20 ㎑. The analyzed shallow water noise spectra were some different from the deep water blown as the Wenz spectra. We could know that the ambient noise level shows higher than it in same condition by effect of various ship activity and the coastal noise, surface waves, and so on. As a result, we produced the coastal ambient noise spectra curve based on these results in shore of the Korea Peninsula.

Design and Development of Antenna with Stabilization of Radiation Pattern and Wide-Band Characteristics for MIMO/LAN/Broadcast Operations (안정된 복사패턴과 광대역 특성을 갖는 MIMO/LAN/방송용 안테나 설계 및 개발)

  • Jang, Yong-Woong
    • Journal of Broadcast Engineering
    • /
    • v.16 no.3
    • /
    • pp.483-489
    • /
    • 2011
  • In this paper, we propose a new antenna, which has wide bandwidth, good radiation patterns, and high-gain characteristics. We analysis the antenna using FDTD(Finite Difference Time Domain) method. And the antenna parameters are optimized to get maximum bandwidth. From the measured results, the bandwidth of the antenna is 0.839 octave, for the S11${\leq}$-10 dB. And the measured cross polarization level of the proposed antenna is less than -25 dB at the center frequency. Experimental data of the return loss and the radiation pattern of the proposed antenna are also presented, and the experimental bandwidth characteristics are relatively in good agreement with the FDTD results. The proposed antenna can be applied to MIMO, LAN, biomedical instruments, broadcasting-network system.

A Study on New Broadband Phase Shifter using λ/8 Parallel Stubs (λ/8 병렬 스터브들을 이용한 새로운 광대역 위상 천이기에 대한 연구)

  • 엄순영;정영배;전순익;육종관;박한규
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.7
    • /
    • pp.657-666
    • /
    • 2002
  • In this paper, a new broadband phase shifter to adjust the slope of dispersive phase characteristic for frequency of transmission network was proposed. The new fundamental network consists of a fixed main line with a length of λ/2 at the center frequency and two double stubs, each with a length of λ/8 at the center frequency, which are open and shorted, respectively, and which are shunted at the edge points of the main line. Characteristic impedances of the main line and two parallel double stubs are adjusted to produce a minimum phase error and to obtain an input and output match at the desired phase shift. Especially, the proposed structure is especially suitable for a broadband phase shifter with large phase shifts more than 90$^{\circ}$, and it is operated in the octave bandwidth. To verify the usefulness of a new broadband phase shifter, each 45$^{\circ}$-, 90$^{\circ}$-, 180$^{\circ}$-bit phase shifter and 3-bit phase shifter(45$^{\circ}$-phase step), which is cascaded in series, operated at the center frequency 3 GHz were designed, fabricated and experimented. The measured results were in very close agreement with the corresponding simulation results over the bandwidth of I/O impedance match and phase error for each phase shift.

Autonomous evaluation of ambient vibration of underground spaces induced by adjacent subway trains using high-sensitivity wireless smart sensors

  • Sun, Ke;Zhang, Wei;Ding, Huaping;Kim, Robin E.;Spencer, Billie F. Jr.
    • Smart Structures and Systems
    • /
    • v.19 no.1
    • /
    • pp.1-10
    • /
    • 2017
  • The operation of subway trains induces secondary structure-borne vibrations in the nearby underground spaces. The vibration, along with the associated noise, can cause annoyance and adverse physical, physiological, and psychological effects on humans in dense urban environments. Traditional tethered instruments restrict the rapid measurement and assessment on such vibration effect. This paper presents a novel approach for Wireless Smart Sensor (WSS)-based autonomous evaluation system for the subway train-induced vibrations. The system was implemented on a MEMSIC's Imote2 platform, using a SHM-H high-sensitivity accelerometer board stacked on top. A new embedded application VibrationLevelCalculation, which determines the International Organization for Standardization defined weighted acceleration level, was added into the Illinois Structural Health Monitoring Project Service Toolsuite. The system was verified in a large underground space, where a nearby subway station is a good source of ground excitation caused by the running subway trains. Using an on-board processor, each sensor calculated the distribution of vibration levels within the testing zone, and sent the distribution of vibration level by radio to display it on the central server. Also, the raw time-histories and frequency spectrum were retrieved from the WSS leaf nodes. Subsequently, spectral vibration levels in the one-third octave band, characterizing the vibrating influence of different frequency components on human bodies, was also calculated from each sensor node. Experimental validation demonstrates that the proposed system is efficient for autonomously evaluating the subway train-induced ambient vibration of underground spaces, and the system holds the potential of greatly reducing the laboring of dynamic field testing.

Low Frequency Noise and It's Psychological Effects

  • Eom, Jin-Sup;Kim, Sook-Hee;Jung, Sung-Soo;Sohn, Jin-Hun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.1
    • /
    • pp.39-48
    • /
    • 2014
  • Objective: This entire study has two parts. Study I aimed to develop a psychological assessment scale and the study II aimed to investigate the effects of LFN (low frequency noise) on the psychological responses in humans, using the scale developed in the study I. Background: LFN is known to have a negative impact on the functioning of humans. The negative impact of LFN can be categorized into two major areas of functioning of humans, physiological and psychological areas of functioning. The physiological impact can cause abnormalities in threshold, balancing and/or vestibular system, cardiovascular system and, hormone changes. Psychological functioning includes cognition, communication, mental health, and annoyance. Method: 182 college students participated in the study I in development of a psychological assessment scale and 42 paid volunteers participated in the study II to measure psychological responses. The LFN stimuli consisted of 12 different pure tones and 12 different 1 octave-band white noises and each stimulus had 4 different frequencies and 3 different sounds pressure levels. Results: We developed the psychological assessment scale consisting of 17 items with 3 dimensions of psychological responses (i.e., perceived physical, perceived physiological, and emotional responses). The main findings of LFN on the responses were as follows: 1. Perceived psychological responses showed a linear relation with SPL (sound pressure level), that is the higher the SPL is, the higher the negative psychological responses were. 2. Psychological responses showed quadric relations with SPL in general. 3. More negative responses at 31.5Hz LFN than those of 63 and 125Hz were reported, which is deemed to be caused by perceived vibration by 31.5Hz. 'Perceived vibration' at 31.5Hz than those of other frequencies of LFN is deemed to have amplified the negative psychological response. Consequently there found different effects of low frequency noise with different frequencies and intensity (SPL) on multiple psychological responses. Conclusion: Three dimensions of psychological responses drawn in regard to this study differed from others in the frequencies and SLP of LFN. Negative psychological responses are deemed to be differently affected by the frequency, SPL of the LFN and 'feel vibration' induced by the LFN. Application: The psychological scale from our study can be applied in quantitative psychological measurement of LFN at home or industrial environment. In addition, it can also help design systems to block LFN to provide optimal conditions if used the study outcome, .i.e., the relations between physical and psychological responses of LFN.

A study on the Characteristics of the Adult Men Sound as by Sasang Constitution Analysed with PSSC-2004 (사상체질음성분석기(四象體質音聲分析機)(PSSC-2004)를 통한 성인남성(成人男性)의 체질별(體質別) 음향특성(音響特性))

  • Kim, Dong-Jun;Jung, Woon-Ki;Choi, Jae-Wan;Kim, Dal-Rae;Jeon, Jong-Weon
    • Journal of Sasang Constitutional Medicine
    • /
    • v.17 no.1
    • /
    • pp.67-83
    • /
    • 2005
  • 1. Objectives The purpose of this study lies on the objectification of the Sasang Constitutional diagnosis. This study was analyzing the constitutional characteristic of adult men voices by PSSC-2004. 2. Methods The study was conducted on the subjects inputted /a/ 2.5-3 sec of 231 adult men voices to PSSC-2004. The statistical analyses are applied to three groups: total group, under 55 year-old group, over 55 year-old group. The group of total 231 was composed with 5 Taeyangins, 32 Soyangins, 102 Taeumins and 92 Soeumins. The under 55 years old group was composed with 4 Taeyangins, 23 Soyangins, 83 Taeumins and 77 Soeumins. The over 55 year-old group was composed with 1 Taeyangin, 9 Soyangins, 19 Taeumins and 15 Soeumins. 3. Results 1) In total group, the Soeumin's mean value of center pitch(4)$(1,000{\sim}2,000Hz)$ was significantly high compared with the others (P=0.034). 2) In total group, the Soeumin's group 3 APQ was significantly low compared with the others (P=0.042). 3) In under 55 year-old group, the Soeumin's center value of center pitch 4$(1,000{\sim}2,000Hz)$ was significantly high compared with the others (P=0.025) 4) In over 55 year-old group, no statistical significance was found between the Taeyangin, Soyangin, Taeumin and Soeumin. 4. Conclusions In under 55 year-old group, Soeumin's voice showed high pitched sound (clearness) at the low frequency (1000-2000Hz). In over 55 year-old group, there is no significant differences. This fits in with that 'Soeumin's voice is 'Yu-tone' born by 'Shang-tone', very short and high.' 'Yu-tone' corresponds to 'Ra' and witch is highest among Gong, Shang, Gao, Chi and Yu. This is related with the appearance that the Soeumin's voice is weak, thin and high tone. Therefore it is supposed that Soeumin adult men's voices are thick, and there are vibrations of the ending. It is accepted one of the Soeumin's characters like as a mild tremor of limbs and deep breath caused by Soeumin's Qi-deficiency. This outcome accords with the theory that Soeumin's Qi is less than the Other constitutions.

  • PDF