• Title/Summary/Keyword: Occupants

Search Result 506, Processing Time 0.029 seconds

A Development of on Instrument for Measuring Glare Sensation in the Visual Field (시야내의 글레어감각 측정용 기기의 개발)

  • Park, Sung-Ryul;Kim, Jeong-Tai;Kim, Won-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.9-17
    • /
    • 2009
  • Discomfort Glare from the artificial light sources is an important issue in assessment of lighting quality for healthy buildings. Glare, as a factor of the characteristics of brightness, which has been defined as the sensation produced by contrast and luminance within an entire field view, unfavorably influences the occupants who performs visual tasks. It may cause annoyance and discomfort by interruption of visibility. In the whole visual field, glare can be determined by effects of the position, the luminance and the size of the light source and brightness of the surroundings. Therefore, experimental equipment is required to maintain a constant visual lighting environment. Recent studies have been developed and used the instrument for glare sensation evaluation but the instruments showed some difficulties to verify the correlation of glare indicators. The instrument have been developed with reference to former studies. It is called the Glare Tester. This is consist of 2[m]-diameter vertical dome screen painted with white flat paint, and light sources installed inside the screen. These light sources can provide various range of brightness at any inner surface of the screen. 2 Glare light sources can provide the value of luminance within the range of $0{\sim}150,000[cd/m^2]$. Moreover, 12 light sources are used for background luminance and it can perform the value of luminance within the range of $0{\sim}350[cd/m^2]$. Several experiments have been conducted using this Glare Tester to evaluate the range of the visibility, the values of BCD and the glare sensation in lower and upper visual field.

Assessment of VOCs Emission Characteristics from Building Materials such as Wall Paper, Paints, and Adhesives Using Small Chamber Method (소형챔버법을 이용한 건축자재 중 벽지, 페인트 및 접착제의 VOCs 방출특성 평가)

  • Lee Suk-Jo;Jang Seong-Ki;Cho Yong-Sung;Jung Kyung- Mi;Jeong Gi-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.2
    • /
    • pp.191-204
    • /
    • 2005
  • Building and furnishing materials and consumer product are important sources of volatile organic compounds(VOCs) and other aldehydes in the indoor environment. Some available evidence indicates that VOCs can cause adverse health effects to the building occupants and contribute to some of the symptoms of what we call, 'Sick House Syndrome' in Korea. The aims of this study were to evaluate the efficiency of emission system and to investigate comparison of the emission characteristics of different building materials such as wall-papers, paints, and adhesives. The emission of VOCs from building materials were determined in the small chambers defining the temperature, relative humidity, and ventilation rate in this study. VOCs were sampled for 20 minutes using Tenax-TA tubes and analysed by GC-MS with thermal desorption. The stability of conditions for temperature and relative humidity in this small chamber system showed that the fluctuation of temperature was between 25.4$\pm$0.3$^{\circ}C$ and that of relative humidity was 50.2$\pm$0.6$\%$ under the airflow rate of 167 mL/min. The emission tests from building materials resulted in TVOC emission rates of 0.011 $\~$ 3.108 mg/m$^{2}$h after 7 days. The general wall-papers emitted toluene abundantly and the natural wall-papers mainly emitted n-butanol and a minor amount of alkanes compound such as n -tetradecane. The remainder consisted of toluene, m,p -xylene, and styrene. The paints mainly emitted toluene and the adhesives mainly emitted chloroform as well as toluene. As a result, this study is expected to suggest meaningful data for future studies in exposure control through selecting healthy building materials and for the establishment of guidelines for various building materials in Korea.

The Changes of Psychological and Physiological Emotional Responses According to Change of the Index of Predicted Mean Vote (PMV) due to Air Conditioning Types (공조방식에 의한 예상 온열감 반응(PMV) 변화에 따른 심리/생리적 감성반응의 변화)

  • Kim, Bo-Seong;Min, Yoon-Ki;Min, Byung-Chan;Kim, Jin-Ho
    • Science of Emotion and Sensibility
    • /
    • v.14 no.4
    • /
    • pp.645-652
    • /
    • 2011
  • This study examined changes of both psychological and physiological emotional responses according to change of the PMV (predicted mean vote) in the heating and the cooling air conditions. For this purpose, the changes of PMV were induced by the heating and cooling operations of the HVAC (heating, ventilation, and air conditioning) systems. In addition, positive/negative and arousal/relaxation were measured as the participant's psychological emotional responses, and HR (heart rate) was measured as the participant's physiological emotional responses. As a result, in same range of the PMV, both psychological and physiological emotional-responses were changed by air conditioning. It is suggested that occupant's emotional responses would depend on the operational conditions of heating and cooling in indoor thermal environments, and both psychological and physiological emotional response should be considered when occupants try to match the indoor thermal environments to their thermal expectations.

  • PDF

Empirical Analyses on Intention to Live and Consumption Expenditure of Urban Residents in Neighboring Counties of Naepo New Town (도심 거주의향과 지역 내 소비지출에 관한 실증분석; 내포신도시 주변도시 도심거주민 의식조사를 중심으로)

  • Im, Jun-Hong;Hong, Sung-Hyo
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.2
    • /
    • pp.678-686
    • /
    • 2017
  • This study is performed with the view point that a strategy to maintain the existing residents as well as to attract people outside is necessary in order to revitalize the downtown of an area. Empirical analyses of this study are focused on the residents in downtowns of the two counties, Hongsung and Yesan which are concerned of becoming hollow. According to the results, the residents who want to continue living in the downtown are the old and the owner-occupants of detached housing units while those who hope to leave to Naepo, a neighboring new town are in their 30's or high income-earners. Thus, policies such as renovating detached housing for the old are required. In addition, policies to reduce outflow of the people who are in their 30's or high income-earners are also needed. Especially, since the resident who is highly probable to leave is estimated to spend 553 thousand Korean Won per year in the downtown, on-going outflow of residents would weaken the local market and threaten the local economy. Consequently, local governments need to set up directions of urban renovation policies by considering decline in population, change in demographic structure, appropriate allocation of limited budget, and sustainable urban development based on empirical research results.

An Experimental Study on the Improvement of Insulation Performance in Old University Buildings and Economic Evaluation (노후화된 대학 건물의 단열성능 향상 실험 및 경제성 평가)

  • Lee, Jeongmin;So, Wonho;Cho, Kyungchan;Choi, Dongnyeok;Lee, Kwon-yeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.287-297
    • /
    • 2020
  • This study examined ways of improving the internal insulation performance of aging university buildings, and to enhance the convenience of occupants in university buildings and the insulation effect of aging buildings. This research was conducted to solve the problem of continuous requests for improving the insulation performance of office workers in the Nehemiah Hall building of Handong University. The results showed that the internal temperature of Nehemiah Hall was low compared to the internal temperature of the adjacent building. Considering the characteristics of the building, the university chose insulating materials under the theme of internal insulation. The experiment was conducted by installing internal wall insulation used in the market by producing a model room that miniaturized the university professor's office. Based on the experimental results, an economic evaluation was conducted to analyze the insulation effect by measuring the heating time and actual heat transmission coefficient. An economic evaluation was conducted by experiment and theory and on a winter and summer basis. According to the research, when an Isopink (30 T) was introduced as an internal insulation material in 60 offices of Nehemiah Hall, it could save up to 1,071,600 won in total during the winter season and 109,200 won during the summer season.

Developing the Service Quality Scale of Business Center: A New B2B Service Retailing Format (신 서비스유통포맷으로서의 비즈니스센터의 서비스품질 평가척도 개발)

  • Kim, Seung-Sub;Yoo, Dong-Keun;Lee, Phil-Soo
    • Journal of Distribution Science
    • /
    • v.12 no.11
    • /
    • pp.101-111
    • /
    • 2014
  • Purpose - This study aims to verify the construct of the service quality suitable to the characteristics of the business center, to develop the scale that can measure the service quality objectively, compare the diverse business centers in Korea, and present desirable methods of business center management and operation. Research design, data, and methodology - In the first stage, literature research and focus group interviews with current users and actual business experts of business centers were conducted. In addition, 69 early stage scale items were derived. In the second stage, a Delphi survey was conducted on the experts of business and academic circles. The measurement items in the early stage were supplemented and revised. The content validity rate (CVR) of 69 measures was computed and then the experts' opinions were used. As a result, the business center service quality scale, made up of 9 organizing factors and 36 measurement items, was constructed. In the third stage, a survey was conducted on the occupants who were currently using the business center. It was to confirm if the developed business center service quality scale could be actually utilized. The data of 435 samples collected were used. To refine the scale items, the exploratory factor analysis (EFA) was conducted repeatedly. Results - The business center service quality scale, made up of 8 factors and 33 items, was developed again. The 8 factors are reliability, speed, kindness, specialty, responsibility, appearance, convenience, and public interest. The reliability coefficient (Cronbach's Alpha) of each factor is greater than .7. Thus, it was confirmed that there was reliability in the measurement items. Further, the model suitability was verified using the confirmatory factor analysis (CFA), and the convergent validity and the discriminant validity were verified. This proved the construct validity. Through this process, the Korea Business Center Service Quality Scale was developed. Based on factor analysis, the developed business center service quality (BCSQ) scale consists of 4 aspects, 8 factors, and 33 items, comprising the "process quality" aspect: reliability (3 items), speediness (4 items), kindness (3 items) factors, the outcome quality aspect: expertise (3 items), responsibility (5 items) factors, the environment quality aspect: appearance (5 items), convenience (3 items) factors, and the public interest aspect: public interest (7 items) factor. However, according to CFA, the BCSQ scale consists of a total of 4 aspects, 8 factors, and 33 items, comprising the "process quality" aspect: reliability (3 items), speediness (3 items), kindness (3 items) factors, the outcome quality aspect: expertise (2 items), responsibility (4 items) factors, the environment quality aspect: appearance (3 items), convenience (2 items) factors, and the public interest aspect: public interest (3 items) factor. Conclusions - The BCSQ scale could serve as a diagnostic tool that will allow business center managers to determine service areas that are weak and in need of attention, and to improve the service quality of the business center.

Development of Management Systems based on IDEF3 Modeling to Improve Owner's Competency of Implementing Green building Certification (친환경건축물인증 발주자업무 수행역량 제고를 위한 IDEF3 모델기반 관리체계 구축)

  • Park, Kyung-Rog;Yi, June-Seong
    • Korean Journal of Construction Engineering and Management
    • /
    • v.14 no.1
    • /
    • pp.52-62
    • /
    • 2013
  • Owners' efforts to acquire Green building certification, which started in 2002, have been rapidly increasing since 2006. The causes of the increased owners' interests are due to various incentives, legal obligation, and purpose of advertising. As project owners generally are deficient in capabilities and knowledge on how to deal with administrative works on certification, they tend to fulfill the minimum requirements for certification. However, effective administration process need capabilities of identifying individual making decision point and review information. The implementation of green building certification system is expected to provide comfort to both occupants and potential users. Furthermore it contributes to reducing energy costs throughout the phase of O&M. In addition, technology innovation in green industry can be obtained. Therefore, this study is intended to support owners in order that they can clarify certification tasks and make a rational decision-making in time. For this purpose, first of all, the major decision points were selected as the gateways of green building certification process. And then management system based on IDEF3 modeling was developed for supporting owners' decision-making performance. This management system will improve owners' overall capacity in handling all the tasks regarding the certification of Green building.

Vibration Control of Mega Frame Structures using a Semi-active Tuned Mass Damper (준능동 TMD를 이용한 메가골조구조물의 진동제어)

  • Kim, Hyun-Su;Lee, Dong-Guen
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.2 s.54
    • /
    • pp.57-68
    • /
    • 2007
  • The mega frame system is becoming popular for the design and construction of skyscrapers because this system exhibits structural efficiency by allowing high rigidity of the structure while minimizing the amount of structural materials to be used. Since the mega frame system is usually adopted for super high-rise buildings, the comfort of occupants may be main concerns in the practical application of this system. For the enhancement of the serviceability of mega frame structures, a semi-active tuned mass damper (STMD) is developed in this study. To this end, a Magnetorheological (MR) damper is employed replacing passive damper as a semi-active damper to improve the control effect of a conventional TMD. Since a conventional finite element model of mega frame structures has significant numbers of DOFs, numerical simulation for investigation of control performances of a STMD is impossible by using the full-order model. Therefore, a reduced-order system using minimal DOFs, which can accurately represent the dynamic behavior of a mega frame structure, is proposed in this study through the matrix condensation technique To improve the efficiency of the matrix condensation technique, multi-level matrix condensation technique is proposed using the structural characteristics of mega frame structures. The efficiency and accuracy of the reduced-order control proposed in this study and the control performance of a STMD were verified using example structures.

Scientific Conservation Treatment of Artifacts Collected from the Lime-soil Mixture Barrier Tombs Excavated from the Site of a Public Residential Area in Godeung-dong, Seongnam (성남 고등 공공주택지구 출토 회격묘 과학적 보존처리)

  • Kim, Woungshin;Jeon, Juyeon;Kim, Beomjun;Han, Minsoo;Lee, Minhye
    • Conservation Science in Museum
    • /
    • v.22
    • /
    • pp.53-68
    • /
    • 2019
  • Two lime-soil mixture barrier tombs were excavated from the tomb complex of the Woo Family of the Danyang Wu clan dating to the Joseon dynasty in Godeung-dong, Seongnam-si, Gyeonggi-do. Relevant records offer information for more precisely dating these tombs and identifying their occupants. Tomb No. 4, in which a married couple was interred, has a corbeled square ceiling and inscriptions and paintings on its outer walls. The conservation treatment and an infrared inspection revealed that they were intended to express mourning. Tomb No. 6 has a corbeled rectangular ceiling and a single individual interred within. As the basic structure of the tomb was partially damaged in the process of disassembling it while moving the burial site, it was planned to exhibit the tomb outdoors after the remains and relics are collected. However, as the conservation treatment revealed the presence of funeral fans and pitch, and since the remaining structure clearly demonstrates the features of lime-soil mixture barrier tombs from the Joseon dynasty, the plan was changed following a meeting of an advisory council that decided in favor of presenting the tomb indoors. According to the analysis, the pitch is assumed to be resin of a rather low purity due to the immixture of foreign substances. The two tombs are expected to serve as important materials for related research, such as changes by period in the forms of Joseon-era tombs.

Modular Building for Urban Disaster Housing: Case Study of Urban Post-Disaster Housing Prototype in New York

  • Ford, George;Ahn, Yong Han;Choi, Don Mook
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.82-89
    • /
    • 2014
  • Disasters that destroy homes and infrastructure and cause significant financial damage are becoming more common as population centers grow. In addition, several natural disasters have resulted in a major loss of life and created countless refugees due to damage to housing. After major catastrophic disasters, it is very important that the government agencies respond to post-disaster housing issues and provide resources such as temporary housing before the full rehabilitation and reconstruction of destroyed and damaged housing. To provide affordable temporary housing for residents who may lose their homes as the result of a catastrophic disaster including storms, government agencies must develop a post-disaster housing prototype. In general, government agencies should explore several different forms of factory-built single-story, single family housing, such as modular homes, panelized homes, and precut homes. In urban cities including New York and Seoul, it is very important to provide housing which supports the demand for higher-density living spaces than single-family homes or trailers typically available due to the high population density and the desire to resettle as many residents as possible in their former neighborhoods. This study identified the urban post-disaster housing prototypes that may provide higher density housing with high quality living spaces, high air quality, and energy efficiency as well as rapid deployment. A case study of "Urban Post-Disaster Housing Prototype Program in New York" was conducted through a detailed interview process with a designer, engineer, contractor, the Office of Emergency Management (OEM) in New York, the U.S. Army Corps of Engineers (USACE), and temporary occupants. An appropriate disaster housing program that can provide living spaces for victims of disasters that keeps residents in their community and allows them to live and work in their neighborhoods was developed.