• Title/Summary/Keyword: Occlusion Force

Search Result 165, Processing Time 0.026 seconds

Effects of implant alignment and load direction on mandibular bone and implant: finite element analysis (임플란트 배열과 하중 방향이 임플란트와 치조골에 미치는 유한요소 응력분석)

  • Chung, Hyunju;Park, Chan;Yun, Kwi-Dug;Lim, Hyun-Pil;Park, Sang-Won;Yang, Hongso
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.3
    • /
    • pp.176-182
    • /
    • 2020
  • Purpose: To evaluate the effects of load direction, number of implants, and alignment of implant position on stress distribution in implant, prosthesis, and bone tissue. Materials and Methods: Four 3D models were made to simulate posterior mandible bone block: two implants and 3-unit fixed dental prosthesis (FDP) with a pontic in the center (model M1), two implants and 3-unit FDP with a cantilever pontic at one end (model M2), FDP supported by three implants with straight line placement (model M3) and FDP supported by three implants with staggered implant configuration (model M4). The applied force was 120 N axially or 120 N obliquely. Results: Peak von Mises stresses caused by oblique occlusal force were 3.4 to 5.1 times higher in the implant and 3.5 to 8.3 times higher in the alveolar bone than those stresses caused by axial occlusal force. In model M2, the connector area of the distal cantilever in the prosthesis generated the highest von Mises stresses among all models. With the design of a large number of implants, low stresses were generated. When three implants were placed, there were no significant differences in the magnitude of stress between staggered arrangement and straight arrangement. Conclusion: The effect of staggering alignment on implant stress was negligible. However, the number of implants had a significant effect on stress magnitude.

Intrusion of the extruded maxillary central incisor using skeletal anchorage system and unilateral segmental intrusion arch (골성 고정원과 편측 분절호선을 이용한 정출된 상악 중절치의 압하 치료)

  • Kwon, Eun-Young;Baek, Young-Jae;Park, Soo-Byung;Kim, Seong-sik;Kim, Yong-il;Choi, Youn-kyung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.3
    • /
    • pp.180-190
    • /
    • 2019
  • Patients who have a moderate periodontitis with pathologic tooth migration of maxillary incisors, it is necessary not only periodontal treatment for reduce periodontal inflammation, but also orthodontic treatment to teeth repositioning. For orthodontic treatment, it is necessary to apply less force and careful considerations of the center of resistance of the tooth and optimal force of tooth movement. At this time, the segmental arch applied only to the target teeth, is more effective and predictable, because applied force and direction can be controlled. In addition, to design the orthodontic appliance that can prevent the unwanted tooth movement that used as an anchorage is important. In recent years, various types of skeletal anchorage system have been used for preventing loss of the anchorage. We reported the patient who had extruded maxillary central incisor due to pathologic tooth migration, treated by a successful periodontal-orthodontic multidisciplinary treatment using an orthodontic appliance designed to apply less traumatic force and reduce an anchorage loss.

Influence of varying cement types and abutment heights on pull-off force of zirconia restorations (시멘트의 종류 및 임플란트 지대주 높이가 지르코니아 수복물의 제거력에 미치는 영향)

  • Yeong-Jun Jung;Yu-Lee Kim;Ji-Hye Jung;Nae-Un Kang;Hyun-Jun Kong
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.2
    • /
    • pp.64-71
    • /
    • 2024
  • Purpose: The purpose of this study is to evaluate Ti-base abutment's three different heights and three different cement types on the pull-off force of zirconia-based restorations. Materials and Methods: A total of 90 fixture lab analogs were embedded in auto polymerizing resin bloack. 90 Ti-base abutments heights of 3 mm, 5 mm, 7 mm were scanned and zirconia restoration were prepared from scanned files. Zirconia restoration were cemented with three different types of cements (temporary, semi-permanent, permanent) following manufacturer's instructions. All 90 specimens were placed and tested in a universal testing machine for pull-out testing. Retention was measured by recording the force at load drop. Statistical analysis was performed using Kruskal-Wallis test for detecting whether there are any statistical significance along cement types or abutment heights. After that, Mann-Whitney test was used for figuring out differences regarding abutment height and the comparison between 3 cements. Results: Temp bond showed significantly lower pull-off force compared to Fujicem regardless of any abutment height. However, there were significant differences between Cem-implant and Fujicem in abutment height of 3 mm and 7 mm, but there was no significant difference in 5 mm. Temp bond and Cem-implant had significant differences only in abutment height of 5 mm. Conclusion: Although Ti-base abutment height did not influenced zirconia restorations' retentiveness, cement types showed significant differences.

Three Dimensional Finite Element Analysis of Kimplant (Kimplant에 관한 3차원 유한요소 분석적 연구)

  • Kim, Woo-Uoung;Jang, Kyung-Soo;Kim, Chang-Whe;Kim, Yung-Soo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.20 no.1
    • /
    • pp.9-17
    • /
    • 2004
  • In this study, the biomechanical characteristics of Kimplant were compared with that of Branemark implant by using three dimensional finite element analysis. Two finite element models were fabricated by inserting each implant into the bone model. The bone model was designed to have 18mm height, 13mm width and 15mm length. The size of each implant was planned to have 4mm width and 10mm length. A 200N force was applied on the center of abutment top in three directions - vertical, horizontal and oblique. After analyzing the stresses of fixture and surrounding bone, following results were obtained. 1. There was similar stress distribution between the two models. 2. The magnitude of maximum principal stress on the implant was similar between the two models but the location of maximum principal stress on the implant was different. 3. The magnitude and location of maximum principal stress on the surrounding bone was similar between the two models.

Implant supported over denture with O-ring abutment (O-ring abutment를 이용한 Implant over denture의 제작)

  • Lee, Sung-Uck;Lee, Jung-Hwan;Park, Hyo-Ryun
    • Journal of Technologic Dentistry
    • /
    • v.26 no.1
    • /
    • pp.209-216
    • /
    • 2004
  • The purpose of this study is to introduce how to make implant supported over denture with Oring. Many kinds of attachments have used to dental restorations. The application of attachment has widely increased implant fixed prosthesis and implant supported over denture. In order that implant supported over denture have properly retention, generally used O-ring, magnetic, bar attachment. O-ring give us an advantage that is required more minimum vertical dimension than bar-type and easily replace with new part. When we make these prosthesis using O-ring, Bar, Ball attachment, we should following procedures. Strong occlusion force leads to fracture of over denture because part of functional mechanism as implant abutment or attachment is spaced. Clips are regularly activated. O-ring and springs are changed every year. The pattern of resorption should be carefully monitored and compensated for by relining procedures. If the over denture appears to rest on the bar or the ball attachments, relining should be performed and clips/caps should be changed.

  • PDF

New Approach for Midface Hypoplasia in Cleft Lip and Palate Patients (구순구개열자의 중안면 열성장 개선을 위한 새로운 접근)

  • Kim, Young-Oh;Choi, Yoon-Kyung;Jung, In-Kyo;Kim, Yong-Deok;Son, Woo-Sung
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • Purpose : To introduce a more effective and efficient protocol for protraction of maxillary complex in CLP patient and demonstrate it by case presentation. Methods : Miniplates are placed on zygomatic buttress and anterior part of mandible, at the time of secondary alveolar bone graft. During the night time, the orthopedic force is applied by wearing elastics from maxillary miniplates to facemask (500 g per side). During the day time, the intermaxillary elastics connecting maxillary miniplates to mandibular miniplates are applied (200 g per side). During the orthopedic treatment, dental alignment is possible. Results and conclusion : By the new protocol, the intermaxillary relation and occlusion are improved due to the stable intraoral anchorage and better cooperation of patients.

  • PDF

STRESS ANALYSIS OF VARIOUS ESTHETIC RESTORATIONS BY FINITE ELEMENT METHOD (유한 요소법을 이용한 수종 심미 수복물의 응력 분석)

  • Jo, Jin-Hee;Vang, Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.129-145
    • /
    • 1991
  • The purpose of this study was to analyze the stresses and displacements of various esthetic restorations and abutment teeth. The finite element models of central incisor were divided into four groups according to the types of restoration. Three load cases were applied; 1) 45 degrees on the incisal edge, 2) horizontal force on the labial surface, and 3) 26 degrees diagonally on the lingual surface. Material property, geometry, and load conditions of each model were inputed to the two dimensional finite element program and stresses and displacements were analyzed. Results were as follows; 1. In the cases of porcelain fused gold ann and porcelain laminate venner, stresses were equally distributed in supporting abutment tooth. 2. The metal coping of porcelain fused gold u and collarless porcelain fused gold crown functioned as a good stress distributor. 3. When the horizontal load applied, the highest tensile and compressive stresses were seen in the cervical margin of restoration and the dentin of the abutment tooth. 4. The highest displacement of restoration was seen when load was applied at an mee of 26 degrees diagonally in lingual surface of tooth in centric occlusion. 5. The influence of loading direction on the stresses and displacements in the restoration was greater than that of various design. 6. The possibility of fracture was highest in porcelain jacket crown.

  • PDF

THE EFFECT OF EXPERIMENTAL BRUXISM ON THE MASSETERIC SILENT PERIOD (인위적인 이갈이가 교근의 Silent Period에 미치는 영향에 관한 연구)

  • Sung, Moo-Gyung;Kim, Kwang-Nam;Chang, Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.25 no.1
    • /
    • pp.205-212
    • /
    • 1987
  • The purpose of this study was to investigate the duration of the silent period of the masseter muscle in normal subjects after experimental bruxism. The material for this study consisted of 9 male subjects with an age range of 22-24 years who showed normal occlusion clinically and were free from any history or symptoms of temporomandibular joint dysfunction. A jaw-jerk was stimulated by tapping the mandibular symphysis during maximal voluntary clenching with a solenoid-driven hammer. And three separate silent period records were made from the left masseter muscle at the following times: at normal state, after experimental bruxism, 1 week after bruxism. The following conclusions were obtained: 1. The average value of the duration of masseteric silent period during maximal voluntary clenching was $33.62{\pm}1.86msec$ when tap force of approximate 650g was applied at normal state. 2. After experimental tooth grinding for 30 minutes, the duration of masseteric silent period increased to $46.29{\pm}4.40msec$. 3. Comparing the duration of silent period measured at normal state with that measured after 1 week, the duration of silent period showed reproducibility.

  • PDF

A Study on the Inner Area of the Dental Arch (치열궁 내측 평면적에 관한 연구)

  • 정성창
    • Journal of Oral Medicine and Pain
    • /
    • v.5 no.1
    • /
    • pp.5-10
    • /
    • 1980
  • Numerous investigators have pointed out that the force of the tongue against the teeth within the dental arches is normally compensated for by the action of the musculature of the cheeks and lips, and that the tongue at rest occupies a large part of the oral cavity. The purpose of this study was to estimate the maximum areas of the tongue movement by measuring the inner area of the dental arches of both the maxilla and the mandible. This study was based on the study models of 30 children and 128 adults who had clinically good occlusion. There were 15 male and 15 female children whose ages ranged from four years to seven years and 82 male and 46 female adults whose ages ranged from fifteen years to fifty four years. The obtained results were as follows : 1. The mean of the maximum areas within the primary dental arches of both the maxilla and the mandible were $7.06\pm0.8\textrm{cm}^2, 5.49\pm0.77\textrm{cm}^2$ in male children and $6.82\pm0.98\textrm{cm}^2, 5.28\pm0.80\textrm{cm}^2$ in female children respectively. 2. The mean of the maximum areas within the permanent dental arches of both the maxilla and mandible were $17.01\pm2.38\textrm{cm}^2, 13.57\pm1.57\textrm{cm}^2$ in male and $16.75\pm2.08\textrm{cm}^2, 13.36\pm1.01\textrm{cm}^2$ in female respectively.

  • PDF

Enhancing Immersiveness in Video see-through HMD based Immersive Model Realization (Video see-through HMD 기반 실감 모델 재현시의 몰입감 향상 방법론)

  • Ha, Tae-Jin;Kim, Yeong-Mi;Ryu, Je-Ha;Woo, Woon-Tack
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.685-686
    • /
    • 2006
  • Recently, various AR-based product design methodologies have been introduced. In this paper, we propose technologies for enhancing robust augmentation and immersive realization of virtual objects. A robust augmentation technology is developed for various lighting conditions and a partial solution is proposed for the hand occlusion problem that occurs when the virtual objects overlay the user' hands. It provides more immersive or natural images to the users. Finally, vibratory haptic cues by page motors as well as button clicking force feedback by modulating pneumatic pressures are proposed while interacting with virtual widgets. Also our system reduces gabs between modeling spaces and user spaces. An immersive game-phone model is selected to demonstrate that the users can control the direction of the car in the racing game by tilting a tangible object with the proposed augmented haptic and robust non-occluded visual feedback. The proposed methodologies will be contributed to the immersive realization of the conventional AR system.

  • PDF