• Title/Summary/Keyword: Occlusal pressure

Search Result 36, Processing Time 0.02 seconds

THE EFFECT OF VARIOUS DESENSITIZING AGENTS ON THE PERMEABILITY OF HUMAN DENTIN (수종의 desensitizing agent가 상아질 투과도에 미치는 영향)

  • Chon, Young-Eui;Jeong, Il-Young;Youn, Tae-Chul
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.322-329
    • /
    • 1999
  • The hydrodynamic theory of dentin sensitivity states that movement of tubular contents or tubular fluid, in either direction of dentinal tubule, causes dentin sensitivity. A corollary of that theory is that anything that can decrease dentinal fluid movement or dentin permeability should decrease dentin sensitivity. A wide variety of physicochemical methods have been used to reduce the permeability and sensitivity of exposed dentin. The purpose of this study was to evaluate the ability of 4 kinds of clinical desensitizing agents(2% NaF, 30% Potassium oxalate, MS Coat$^{(R)}$, Tubulitec system$^{(R)}$) to reduce the rate of fluid flow through dentin in vitro. Sixty coronal dentin discs, 1mm in thickness, were prepared from extracted third molars, free from decay and wear. Dentin discs were treated with 3% EDTA(Tubulicid Plus$^{(R)}$(Dental Therapeutics AB, Sweden)) to remove the smear layer and debris occluding the tubular orifices. After placing the discs in a split chamber device, the rate at which physiologic saline solution could filter across dentin under 150cm $H_2O$ hydrostatic pressure was measured. The occlusal side of the discs were then treated with MS Coat$^{(R)}$, 2% NaF, Tubulitec system$^{(R)}$, and 30% Potassium oxalate, and the filter ratio of the saline solution was measured again. The following conclusions were drawn : 1. Hydraulic conductance which was measured after the application of desensitizing agents was decreased in all the groups(p<0.05). 2. % change of hydraulic conductance was compared but no significant difference was found among the four desensitizing agents(p>0.05). 2% NaF, 30% Potassium oxalate, MS Coat$^{(R)}$ and Tubulitec system$^{(R)}$ decreased the permeability of dentin. It is considered that above four agents can be used in treating the hypersensitive teeth.

  • PDF

MICROLEAKAGE TEST ACCORDING TO ACID ETCHING TREATMENT IN CLASS V COMPOMERS (치면 산처리가 V급 와동의 compomer 수복에서 미세누출에 미치는 영향)

  • Moon, Sang-Hee;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.2
    • /
    • pp.351-360
    • /
    • 2000
  • The purpose of this study was to evaluate the microleakage of class V compomers according to acid etching treatment and treatment times. Extracted 180 sound human molar teeth were selected then prepared physiologic pulpal pressure far this experiment. In this study class V cavities were prepared on buccal surface with gingival margin located in 1mm superior to CEJ under simulate physiological conditions. These specimens were randomly divided into 6 groups of 30 each and restored following methods : A: Dyract AP + Prime&Bond 2.1 Group 1 : No acid etching, according to manufacturer's instruction. Group 2 : 15 seconds acid etching and same method with Group 1. Group 3 : 30 seconds acid etching and same method with Group 1. B: F2000 groups + Single Bond adhesive Group 1 : No acid etching, according to manufacturer's instruction. Group 2 : 15 seconds acid etching and same method with Group 1 Group 3 : 30 seconds acid etching and same method with Group 1. After 500 thermocycling between $5^{\circ}C\;and\;55^{\circ}C$, the specimens were sealed with glass ionomer and nail varnish then placed in 5% methylene blue dye for 5 hours and rinsed with tab water. The specimens were embedded in orthodontic clear resin, then sectioned buccolingually through the center of restoration with a low speed diamond saw. The dye penetration on each of the specimens were then observed with a stereomicroscope at $\times20$ magnification. The results of this study were statistically analyzed using the indepedent sample t-test and analysis of variance. Results were as follows, 1. In occlusal walls, microleakage were significantly reduced in acid etched group restored with Dyract AP but no statistically significance in F2000 groups. 2. In gingival walls, microleakage were significantly reduced in group 2 restored with Dyract AP, and group 2 and group 3 in F2000 groups. 3. All groups, except group 3 in Dyract AP, showed significantly less microleakage in occlusal wall than gingival wall. 4. No statistical significance were showed between group 2 and group 3 in both materials.

  • PDF

Study of the fracture resistance of zirconia on posterior fixed partial dentures based on inter-abutment distance (지르코니아 고정성 국소의치의 지대치간 거리에 따른 파절저항성에 관한 연구)

  • Park, Gi-Beom;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.61-69
    • /
    • 2020
  • Purpose: Zirconia fixed partial dentures with mandibular 2nd premolar and 2nd molar as abutments are fabricated and then the effects of inter-abutment distance on fracture resistance of zirconia fixed partial dentures is studied. Materials and Methods: The materials used in this study are Cameleon S zirconia block and S2 zirconia block, which are divided into CS Group and S2 Group applying different inter-abutment distance for each material, and the sintered zirconia fixed partial denture was luted to the epoxy resin die using a temporary luting cement, and then the fracture resistance was measured by placing a 6 mm diameter hardened steel ball on the occlusal surfaces of the pontics and applying pressure at a cross head speed of 1.0 mm/min on a universal testing machine with a load cell of 5.0 kN. Results: The fracture resistance of zirconia fixed partial dentures is not significantly affected by inter-abutment distance The fracture resistance of zirconia fixed partial dentures in CS Group was significantly higher in 15 mm of inter-abutment distance than in 13 mm and 17 mm of inter-abutment distance (P < 0.05). The fracture resistance of zirconia fixed partial dentures in S2 Group was not significantly different between the three groups (P > 0.05). Conclusion: The fracture resistance of zirconia fixed partial dentures with mandibular 2nd premolar and 2nd molar as abutments does not significantly affected by the inter-abutment distance.

COMPARATIVE STUDY ON THE FRACTURE STRENGTH OF EMPRESS 2 CERAMIC AND TARGIS-VECTRIS CROWN

  • Cha Young-Joo;Yang Jae-Ho;Lee Sun-Hyung;Han Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.6
    • /
    • pp.599-610
    • /
    • 2001
  • Due to an increasing interest in esthetics and concerns about toxic and allergic reactions to certain alloys, patients and dentists have been looking for metal-free tooth-colored restorations. Recent improvement in technology of new all-ceramic materials and composite materials has broadened the options for esthetic single crown restorations. The aim of this investigation was to study the fracture strength of the metal-free posterior single crowns fabricated using two recently introduced systems, Empress 2 ceramic and Targis-Vectris. Forty premolar-shaped stainless steel dies with the 1mm-wide circumferential shoulder were prepared. Ten cylindrical crowns having a diameter of 8.0mm and total height of 7.5mm were fabricated for each crown system respectively(PFM, Empress staining technique, Empress 2 layering technique, and Targis- Vectris). The crowns were filled with cement and placed on the stainless steel dies with firm finger pressure. The crowns were then stored in distilled water at room temperature for 24 hours before testing. The crowns were tested for fracture strength in an Instron universal testing machine (Instron 6022). With a crosshead speed of 1mm/min the center of the occlusal surface of the crown was loaded using a 4-mm-diameter stainless steel ball until fracture occurred. The fracture surfaces of the crowns were gold coated and examined using scanning electron microscopy(Jeol JSM-840 Joel Ltd., Akishima, Tokyo, Japan). Within the parameters of this study the following conclusions were drawn: 1. The mean fracture strength for PFM crowns was 5829(${\pm}906$)N; for Empress staining technique the fracture strength was 1697(${\pm}604$)N; for Empress 2 Layering technique the fracture strength was 1781N(${\pm}400$)N, and the fracture strength for Targis- Vectris was 3093(${\pm}475$)N. 2. The fracture strength of the PFM crowns was significantly higher than that of the Empress 2 and the Targis-Vectris crowns (P<0.05). 3. The fracture strength of the Targis-Vectris crowns was significantly higher than that of the Empress 2 crowns (P<0.05). 4. No statistical difference was found when Empress staining technique was compared with Empress 2 layering technique. 5. The SEM image of fracture surface of Empress 2 crown showed a very dense microstructure of the lithium disilicate crystals and the SEM image of fracture surface of Targis-Vectris crown showed indentations of Vectris and some fibers tom off from Vectris.

  • PDF

Comparison of micro CT and cross-section technique for evaluation of marginal and internal fit of lithium disilicate crowns (전부 도재관의 변연 및 내면 간극에 대한 micro CT와 절단 시편 측정법의 비교)

  • Ko, In-Seok;Kim, Jeong-Mi;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.226-233
    • /
    • 2016
  • Purpose: The purpose of this study was to evaluate the adaptation of lithium disilicate crowns fabricated by CAD-CAM (computer aided design-computer aided manufacturing) and heat-press technique to compare two different measurement methods in assessing fit of the ceramic crowns: micro CT and cross-section technique. Materials and methods: A prepared typodont mandibular molar for ceramic crown was duplicated and ten dies were produced by milling the PMMA (polymethylmethacrylate) resin. Ten vinyl polysiloxane impressions were made and stone casts were produced. Five dies were used for IPS e.max Press crowns with heat-press technique. The other five dies were used for IPS e.max CAD crowns with CAD-CAM technique. Ten lithium disilicate crowns were cemented on the resin dies using zinc phosphate cement with finger pressure. The marginal and internal fits in central buccolingual plane were evaluated using a micro CT. Then the specimens were embedded and cross-sectioned and the marginal and internal fits were measured using scanning electronic microscope. The two measurement methods and two manufacturing methods were compared using Mann-Whitney U test (SPSS 22.0). Results: The marginal and internal fit values using micro CT and cross-section technique were similar, showing no significant differences. There were no significant differences in adaptation between lithium disilicate crowns fabricated with CAD-CAM and heat-press technique. Conclusion: Both micro CT and cross-section technique were acceptable methods in the evaluation of marginal and internal fit of lithium disilicate crown. There was no difference in adaptation between lithium disilicate crowns fabricated with CAD-CAM and heat-press technique except occlusal fit.

FINITE ELEMENT ANALYSIS OF MAXILLARY CENTRAL INCISORS RESTORED WITH VARIOUS POST-AND-CORE APPLICATIONS (여러가지 post-and-core로 수복된 상악 중절치의 유한요소법적 연구)

  • Seo, Min-Seock;Shon, Won-Jun;Lee, Woo-Cheol;Yoo, Hyun-Mi;Cho, Byeong-Hoon;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.4
    • /
    • pp.324-332
    • /
    • 2009
  • The purpose of this study was to investigate the effect of rigidity of post core systems on stress distribution by the theoretical technique, finite element stress-analysis method. Three-dimensional finite element models simulating an endodontically treated maxillary central incisor restored with a zirconia ceramic crown were prepared and 1.5 mm ferrule height was provided. Each model contained cortical bone, trabecular bone, periodontal ligament, 4 mm apical root canal filling, and post-and-core. Six combinations of three parallel type post (zirconia ceramic, glass fiber, and stainless steel) and two core (Paracore and Tetric ceram) materials were evaluated, respectively. A 50 N static occlusal load was applied to the palatal surface of the crown with a $60^{\circ}$angle to the long axis of the tooth. The differences in stress transfer characteristics of the models were analyzed. von Mises stresses were chosen for presentation of results and maximum displacement and hydrostatic pressure were also calculated. An increase of the elastic modulus of the post material increased the stress, but shifted the maximum stress location from the dentin surface to the post material. Buccal side of cervical region (junction of core and crown) of the glass fiber post restored tooth was subjected to the highest stress concentration. Maximum von Mises stress in the remaining radicular tooth structure for low elastic modulus resin core (29.21 MPa) was slightly higher than that for high elastic modulus resin core (29.14 MPa) in case of glass fiber post. Maximum displacement of glass fiber post restored tooth was higher than that of zirconia ceramic or stainless steel post restored tooth.