• 제목/요약/키워드: Occlusal force

검색결과 270건 처리시간 0.028초

Evaluation of the effect of two different occlusal splints on maximum occlusal force in patients with sleep bruxism: a pilot study

  • Karakis, Duygu;Dogan, Arife;Bek, Bulent
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권2호
    • /
    • pp.103-108
    • /
    • 2014
  • PURPOSE. The occlusal splint has been used for many years as an effective treatment of sleep bruxism. Several methods have been used to evaluate efficiency of the occlusal splints. However, the effect of the occlusal splints on occlusal force has not been clarified sufficiently. The purpose of this study was to evaluate the effect of occlusal splints on maximum occlusal force in patients with sleep bruxism and compare two type of splints that are Bruxogard-soft splint and canine protected hard stabilization splint. MATERIALS AND METHODS. Twelve students with sleep bruxism were participated in the present study. All participants used two different occlusal splints during sleep for 6 weeks. Maximum occlusal force was measured with two miniature strain-gage transducers before, 3 and 6 weeks after insertion of occlusal splints. Clinical examination of temporomandibular disorders was performed for all individuals according to the Craniomandibular Index (CMI) before and 6 weeks after the insertion of splints. The changes in mean occlusal force before, 3 and 6 weeks after insertion of both splints were analysed with paired sample t-test. The Wilcoxon test was used for the comparison of the CMI values before and 6 weeks after the insertion of splints. RESULTS. Participants using stabilization splints showed no statistically significant changes in occlusal force before, 3, and 6 weeks after insertion of splint (P>.05) and participants using Bruxogard-soft splint had statistically significant decreased occlusal force 6 weeks after insertion of splint (P<.05). There was statistically significant improvement in the CMI value of the participants in both of the splint groups (P<.05). CONCLUSION. Participants who used Bruxogard-soft splint showed decreases in occlusal force 6 weeks after insertion of splint. The use of both splints led to a significant reduction in the clinical symptoms.

골유착성 임플랜트 지지 고정성 보철물과 자연치의 최대교합력 비교 (COMPARISON OF MAXIMUM OCCLUSAL FORCES ON OSSEOINTEGRATED IMPLANT SUPPORTED FIXED PROSTHESES AND NATURAL TEETH)

  • 권영숙;황선홍;한동후
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.498-510
    • /
    • 2005
  • Purpose: The purpose of this study was to compare the maximum occlusal force implant prostheses to natural teeth. Material and Method: Fifty nine patients treated either with $Br{\aa}anemark$ implants and ITI implants during the recent ten years were involved in this study. The maximum occlusal force were measured with unilateral bite force recorder and dental prescale system. Results: 1. The maximum occlusal forces of the implant prostheses and natural teeth were not significantly different where measured with unilateral bite force recorder and dental prescale system. 2. The maximum occlusal forces were not significantly different between $Br{\aa}nemark$ implant and ITI implant prostheses. 3. The maximum occlusal forces of the implant prostheses had lower when compared with natural teeth during 1-6 months functional periods when measured with the unilareral bite force recorder(P<0.05) and 1-12 months functional periods when measured with the dental prescale system(P<0.05). After these periods there was not statistical significant difference between the implant prostheses and natural teeth. 4. The maximum occlusal forces of the wide diameter implant prostheses were higher than the maximum occlusal forces of the regular diameter implant prostheses when measured with dental prescale system(P<0.05), but there was no significant difference between the wide diameter and the regular diameter implant prostheses when measured with unilateral bite force recorder. 5. The maximum occlusal forces of the single implant prostheses were not significantly different with the splinting implants prostheses. 6. The maximum occlusal forces of the implant prostheses were not significantly different by age and sex. 7. There was significantly different between maximum occlusal forces measured with unilateral bite force recorder and dental prescale system(P<0.0001) but there was positive correlation(r=0.52. P<0.05). Conclusion: The maximum occlusal forces of the implant prostheses were not significantly different to natural teeth during clenching and unilateral maximum biting.

Relationship between articulation paper mark size and percentage of force measured with computerized occlusal analysis

  • Qadeer, Sarah;Kerstein, Robert;Kim, Ryan Jin-Yung;Huh, Jung-Bo;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권1호
    • /
    • pp.7-12
    • /
    • 2012
  • PURPOSE. Articulation paper mark size is widely accepted as an indicator of forceful tooth contacts. However, mark size is indicative of contact location and surface area only, and does not quantify occlusal force. The purpose of this study is to determine if a relationship exists between the size of paper marks and the percentage of force applied to the same tooth. MATERIALS AND METHODS. Thirty dentate female subjects intercuspated into articulation paper strips to mark occlusal contacts on their maxillary posterior teeth, followed by taking photographs. Then each subject made a multi-bite digital occlusal force percentage recording. The surface area of the largest and darkest articulation paper mark (n = 240 marks) in each quadrant (n = 60 quadrants) was calculated in photographic pixels, and compared with the force percentage present on the same tooth. RESULTS. Regression analysis shows a bi-variant fit of force % on tooth (P<.05). The correlation coefficient between the mark area and the percentage of force indicated a low positive correlation. The coefficient of determination showed a low causative relationship between mark area and force ($r^2$ = 0.067). The largest paper mark in each quadrant was matched with the most forceful tooth in that same quadrant only 38.3% of time. Only 6 2/3% of mark surface area could be explained by applied occlusal force, while most of the mark area results from other factors unrelated to the applied occlusal force. CONCLUSION. The findings of this study indicate that size of articulation paper mark is an unreliable indicator of applied occlusal force, to guide treatment occlusal adjustments.

교합력 비대칭률과 중간 목갈비근 근육 두께의 비대칭률 상관관계 (Correlation between the Asymmetric Ratio of Occlusal Force and the Thickness of the Middle Scalene Muscle)

  • 채정병;조현래
    • PNF and Movement
    • /
    • 제14권1호
    • /
    • pp.53-57
    • /
    • 2016
  • Purpose: This study aimed to examine the correlation between the asymmetric ratio of occlusal force of the temporomandibular joint and the thickness of the middle scalene muscle. Methods: The study measured the occlusal force of the right and left temporomandibular joints in 30 subjects (12 males and 18 females). Pearson's correlation analysis was performed to examine the effect of occlusal force on the asymmetric ratio of the thickness of their middle scalene muscles by measuring the force using ultrasound after the break. Results: The correlation between the asymmetric ratio of occlusal force and muscle thickness is 0.41, according to Pearson's correlation coefficient. Therefore, the result shows a moderate correlation with the asymmetric ratio of the temporomandibular joint depending on differences in the thickness of the middle scalene muscle. Conclusion: Based on the above results, the asymmetric ratio of occlusal force was found to correlate with the thickness of the middle scalene muscle. Thus, therapeutic intervention is required for the middle scalene muscle in the case of temporomandibular joint disorder.

교합력 수준에 따른 저작근 근활성도에 관한 연구 (Study on the Activity Patterns of Masticatory Muscles according to the Levels of Occlusal Force)

  • Byung-Gook Kim;Woo-Cheon Kee;Sung-Su Jung
    • Journal of Oral Medicine and Pain
    • /
    • 제15권1호
    • /
    • pp.27-35
    • /
    • 1991
  • In order to evaluate muscular activity patterns of masticatory muscles and asymmetry patterns of muscular activity according to the levels of occlusal force, twenty-one individuals of age ranged from 23 to 27 years were examined. They were selected according to the following criteria : 1) no symptoms of temporomandibular disorder, 2) complete dentition except third molars, 3) normal or Angle's class I molar relationship and 4) no experience of dental treatment. The electromyographic amplitudes was measured for evaluation of muscular activity and asymmetric patterns of masseter and anterior temporal muscle during unilateral clenching at the levels of 10%, 20%, 40% and 50% of the maximum occlusal force by use of electromyogram and bite force meter. The obtained results were as follows : 1. The muscle activity indices of masticatory muscles of clenching side at the clenching levels of 10%, 20% and 30% of the maximum occlusal force were -19.12, -9.87, -0.49%, so that activity of anterior temporal muscle was dominant than that of masseter muscle. At the levels of 40%, 50% of the maximum occlusal force, muscle activity indices were 4.68%, 6.70%, so that activity of masseter was dominant at all level and as the levels of occlusal force was increased, muscular activity index was tend to decrease. 2. In masseter, asymmetry indices of muscular activity at the levels of 10%, 20% of maximum occlusal force were -10.34 and -1.24%, so that muscular activity of non-clenching side were dominant and at the levels of 30%, 40% and 50% each of maximum occlusal force, muscular activity was dominant on clenching side as 4.68, 7.18 and 10.9%. In anterior temporal muscle, asymmetry indices were 33.38%, 25.46, 2095, 10.23 and 15.45% at the levels of 10%, 20%, 30%, 40% and 50% each of maximum occlusal force, so that activity of clenching 15.45% at the levels of 10%, 20%, 30%, 40% and 50% each of maximum occlusal force, so that activity of clenching side was dominant than that of non-clenching side at all levels, but as the levels of occlusal force was increased, asymmetry indices of muscular activity was tend to decrease. 3. Between both sides, average electromyographic amplitudes of masseter and anterior temporal muscle were correlated, so that as the levels of occlusal force was increased, average electromyographic amplitudes of both side in same muscle were increased proportionally. But asymmetry indices between muscular activities of masseter and anterior temporal muscle were not correlated.

  • PDF

경찰 종사자의 측두하악장애환자에서 T-scan II System을 이용한 교합분석 (Occlusal Analysis in the Policemen with Temporomandibular Disorders Using T-scan II System)

  • 임현대;정승아;이유미
    • Journal of Oral Medicine and Pain
    • /
    • 제31권4호
    • /
    • pp.365-373
    • /
    • 2006
  • 이 연구는 경찰사회에서의 측두장애환자의 교합상태를 평가하여 습관적인 최대교합시에 교합접촉 시기와 접촉수, 접촉힘을 분석하여 과도한 개구나 이악물기등의 악습관 교정을 제시 하는데 있다. 경찰사회에서는 일반 사회에는 다른 양상의 최대 개구, 습관적인 긴밀한 최대 교합상태 등으로 인하여 측두하악장애에 영향을 미칠 수 있다. 반복적인 훈련이나 일상생활에서의 변화는 그동안 유지되어 오던 저작근을 비롯한 악구강계 평형 상태에 변화를 초래하여 측두하악관절과 그에 따른 구조물에 동통을 유발 내지는 악화 시킬 수 있다. 본 연구는 측두하악장애에 영향을 미칠 수 있는 교합상태를 조사하기 위하여 T-scan II system(Tekscan Co., USA)을 이용하였으며, 최대 교합력을 발휘하기 위하여 약 20 mm 정도의 개구 상태에서 최대교합시까지 물었다. 경찰종사자의 측두하악장애환자는 일반 측두장애환자보다 최초 접촉부터 최대 접촉까지 걸리는 시간은 오래 걸리며, 최종 접촉까지의 시간은 보다 짧았으며, 최종 교합접촉력은 더 강하여, 더 짧은 시간에 강한 힘을 유지한 채 폐구가 이루어져 측두하악관절에 더 많은 잔존한 부하를 전달하였다. 이환 측과 교합접촉 시간, 교합 접촉 힘등의 교합양상과는 관계가 미약하였으며, 최대 접촉력이 가해진 시기에서 우측이 이환 측이면 우측 악궁에, 좌측이 이환측일 경우 좌측 악궁에 집중되는 좌, 우 악궁간 불균형을 보였다. 이상의 결과에서 측두하악장애를 가진 경찰 종사자들의 하악 운동에 보다 부드러운 움직임과 습관적인 최대 교합상태에서의 보다 적은 힘을 유지해야 할 것으로 생각되어진다.

수면이갈이 환자에서 교합안정장치 사용 후 교합력 및 동기능적교합분석: 예비 연구 (Changes of bite force and dynamic functional occlusion analysis after occlusal stabilization splint therapy in sleep bruxism patients: a pilot study)

  • 김재연;최이슬;송율빈;박원서;김성택
    • 구강회복응용과학지
    • /
    • 제38권4호
    • /
    • pp.204-212
    • /
    • 2022
  • 목적: 수면이갈이 환자에서 한달 간 수면 시 교합안정장치를 장착하였을 때 교합력과 교합 접촉 면적 및 동기능적교합분석의 변화량을 비교하고자 하였다. 연구 재료 및 방법: 2021년 10월부터 2022년 7월까지 연세대학교 치과대학병원 구강내과 외래에 방문한 수면이갈이 환자 30명 중 교합안정장치를 수면 중 착용하는 실험군(treatment; n = 15)과 교합안정장치를 착용하지 않는 대조군(control; n = 15)으로 구성하였다. 교합안정장치 장착 전, 장착 1개월 후에 교합력 검사와 동기능적교합분석(측방, 전후방 하악 운동 시 좌/우 힘의 균형, 평균 교합력, 최대 교합력, 최대 접촉 개수)을 진행하였다. 결과: 한달 간 수면 중 교합안정장치를 착용하는 실험군과 교합안정장치를 착용하지 않는 대조군에서 교합력과 교합 접촉 면적은 차이가 없었으나 측방 및 전후방 운동에서 평균 교합력과 최대 교합력, 전후방 운동에서 최대 접촉 개수가 유의한 차이가 있었음을 관찰하였다. 결론: 교합안정장치가 측방, 전후방 운동을 하는 이갈이 환자에게 도움이 될 것으로 사료되며, 향후 추가적으로 대단위 집단을 대상으로 하는 이중 맹검연구가 필요할 것으로 사료된다.

유리단 국소의치 환자에서 T-scan system을 이용한 중심교합시에 교합접촉 양상 연구 (COMPUTERIZED EVALUATION OF OCCLUSAL CONTACTS IN CENTRIC CLOSURE IN DISTAL EXTENSION PARTIAL DENTURE CASES)

  • 이호용
    • 대한치과보철학회지
    • /
    • 제30권4호
    • /
    • pp.565-573
    • /
    • 1992
  • This clinical study was to analyze occlusal contacts in maximum intercuspation on distal extension partial denture and to compare tooth contact state between the denture teeth and abutment teeth by time mode and force mode using the T-scan system. The subjects ware twenty-one adult patients with upper natural teeth and lower distal extension partial denture. Conclusion : 1. The patient with simultaneous occlusal contacts both denture tooth and abutment and bilaterally in Kennedy Class I cases was one-sixth, but there was no one with symmetric occlusal and equal force among bilateral denture teeth and abutments. 2. The five-fifteenth of Kennedy Class I case patients resulted in simultaeous occlusal contacts bet-ween denture teeth and abutments but no one has the symmetric occlusal contacts and unifarm force between denture teeth and abutment teeth.

  • PDF

기능 노출 기간에 따른 골 유착성 임플란트의 촉각 감지도와 최대 교합력의 변화 (OCCLUSAL FORCE AND ORAL TACTILE SENSIBILITY MEASURED IN PARTIALLY EDENTULOUS PATIENTS WITH BR NEMARK IMPLANTS AND NATURAL TEETH: A CLINICAL STUDY)

  • 정복영;전영식;한동후
    • 대한치과보철학회지
    • /
    • 제37권1호
    • /
    • pp.23-41
    • /
    • 1999
  • During the previous several decades the osseointegrated implants have been considered as the most ideal therapy for the fully edentulous or partially edentulous patients. Although the research on the biocompatibility of osseointegration, the oral tactile function, and the histo-neurologic study had been performed, the change of the oral tactile sensibility and maximal occlusal force according to the postinsertion time of implant prostheses has not been studied. The purpose of this study was to compare the oral tactile sensibility and maximal occlusal force of implant pros-theses to natural teeth according to the specific postinsertion time intervals. The fifty seven patients treated with $Br{\aa}nemark$ implants during the recent seven years were involved in this study. The oral tactile sensibility and maximal occlusal force were measured according to the postinsertion time (${\leqq}6\;months,\;{\leqq}12\;{\leqq}\;18\;months\;{\leqq}\;24\;months,\;and\;{\geqq}20\;months$) 1. The passive tactile threshold of implants was higher than 6-7 times when comparing to natural teeth(P<0.05) 2. The absolute pressure threshold in horizontal and vertical direction for the passive tactile sensibility had decreased significantly in the post insertion time 13-18 months group and had increased significantly in the post insertion time over 25 months group (P<0.05) 3. 50% limit thickness and 100% absolute thickness for the active tactile sensibility had decreased significantly in the postinsertion time 7-12 months group ($AT_{50}:P<0.005,\;AT_{100}:P<0.05$) 4. The maximal occlusal force of the implants prostheses had decreased when comparing with natural teeth in the postinsertion time 1-6 months group(P<0.05) and after that there was no significant difference between the implant prostheses and natural teeth(P<0.05) 5. Maximal occlusal force according to the postinsertion time had increased significantly in the 13-18 months group (P<0.05) after that there was no significant difference. 6. There was positive correlation between age and oral tactile sensibility tested in horizontal and vertical direction ($P_{H:r}=0.39,\;P_{v:r}=0.41$) and there was no correlation between age and maximal occlusal force, age and active tactile sensibility 7. According to the results or the questionnaire, 76.6% of the patients were satisfied with the function and 96.7% of the patients were satisfied with the sensibility. In conclusion oral tactile sensibility and maximal occlusal force of implants have changed with the postinsertion time. Oral tactile function of implants was lower than that of the natural teeth, but for the maximal occlusal force there was no difference between implants and natural teeth.

  • PDF

T-scan III 시스템을 이용한 하악 측방운동 시 교합접촉 양상의 분석 (Pattern Analysis of Occlusal Contacts During Lateral Excursion Using T-scan III System)

  • 이상민
    • 구강회복응용과학지
    • /
    • 제29권1호
    • /
    • pp.59-68
    • /
    • 2013
  • 이 논문의 목적은 시간에 따른 교합의 변화를 측정할 수 있는 T-scan system을 이용하여 젊은 성인 남성(33명)정상교합에서의 하악골 측방운동 시 교합접촉 양상을 분석하는 것이다. 정해진 하악 위치에서의 교합접촉이 아닌, 기능적 범위 내에서 비작업측 교합이개 시점에서의 교합접촉 양상을 분류하고 분류된 군 간에 교합이개 시간, 측방유도 시 견치가 담당하는 교합력의 비율, 측방운동 시 가해지는 교합력 등을 비교하였다. 연구 결과 기존의 분류와는 다른 측방접촉들이 존재하였고 군기능 유도가 우세하게 나타났다. 교합이개 시간, 측방유도 시 견치가 담당하는 교합력의 비율, 측방운동 시 가해지는 교합력 등에서 군 간의 유의한 차이를 나타내었다. T-scan system은 교합접촉 양상을 분류하고 교합력, 교합이개 시간, 견치가 담당하는 교합력 비율 등의 항목을 비교 분석하는데 있어서 유용한 도구이다.