Browse > Article
http://dx.doi.org/10.4047/jap.2014.6.2.103

Evaluation of the effect of two different occlusal splints on maximum occlusal force in patients with sleep bruxism: a pilot study  

Karakis, Duygu (Department of Prosthodontics, Faculty of Dentistry, Gazi University)
Dogan, Arife (Department of Prosthodontics, Faculty of Dentistry, Gazi University)
Bek, Bulent (Department of Prosthodontics, Faculty of Dentistry, Gazi University)
Publication Information
The Journal of Advanced Prosthodontics / v.6, no.2, 2014 , pp. 103-108 More about this Journal
Abstract
PURPOSE. The occlusal splint has been used for many years as an effective treatment of sleep bruxism. Several methods have been used to evaluate efficiency of the occlusal splints. However, the effect of the occlusal splints on occlusal force has not been clarified sufficiently. The purpose of this study was to evaluate the effect of occlusal splints on maximum occlusal force in patients with sleep bruxism and compare two type of splints that are Bruxogard-soft splint and canine protected hard stabilization splint. MATERIALS AND METHODS. Twelve students with sleep bruxism were participated in the present study. All participants used two different occlusal splints during sleep for 6 weeks. Maximum occlusal force was measured with two miniature strain-gage transducers before, 3 and 6 weeks after insertion of occlusal splints. Clinical examination of temporomandibular disorders was performed for all individuals according to the Craniomandibular Index (CMI) before and 6 weeks after the insertion of splints. The changes in mean occlusal force before, 3 and 6 weeks after insertion of both splints were analysed with paired sample t-test. The Wilcoxon test was used for the comparison of the CMI values before and 6 weeks after the insertion of splints. RESULTS. Participants using stabilization splints showed no statistically significant changes in occlusal force before, 3, and 6 weeks after insertion of splint (P>.05) and participants using Bruxogard-soft splint had statistically significant decreased occlusal force 6 weeks after insertion of splint (P<.05). There was statistically significant improvement in the CMI value of the participants in both of the splint groups (P<.05). CONCLUSION. Participants who used Bruxogard-soft splint showed decreases in occlusal force 6 weeks after insertion of splint. The use of both splints led to a significant reduction in the clinical symptoms.
Keywords
Occlusal splint; Bruxogard-Soft splint; Occlusal force; Sleep bruxism; Strain-gage;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Rompré PH, Daigle-Landry D, Guitard F, Montplaisir JY, Lavigne GJ. Identification of a sleep bruxism subgroup with a higher risk of pain. J Dent Res 2007;86:837-42.   DOI
2 Fricton JR, Schiffman EL. Reliability of a craniomandibular index. J Dent Res 1986;65:1359-64.   DOI   ScienceOn
3 Koc D, Dogan A, Bek B, Yucel M. Effects of increasing the jaw opening on the maximum bite force and electromyographic activities of jaw muscles. J Dent Sci 2012;7:14-9.   DOI   ScienceOn
4 Narita N, Funato M, Ishii T, Kamiya K, Matsumoto T. Effects of jaw clenching while wearing an occlusal splint on awareness of tiredness, bite force, and EEG power spectrum. J Prosthodont Res 2009;53:120-5.   DOI   ScienceOn
5 Braun S, Bantleon HP, Hnat WP, Freudenthaler JW, Marcotte MR, Johnson BE. A study of bite force, part 1: Relationship to various physical characteristics. Angle Orthod 1995;65:367-72.
6 Kogawa EM, Calderon PS, Lauris JR, Araujo CR, Conti PC. Evaluation of maximal bite force in temporomandibular disorders patients. J Oral Rehabil 2006;33:559-65.   DOI   ScienceOn
7 Lobbezoo F, van der Zaag J, van Selms MK, Hamburger HL, Naeije M. Principles for the management of bruxism. J Oral Rehabil 2008;35:509-23.   DOI   ScienceOn
8 Sheikholeslam A, Holmgren K, Riise C. A clinical and electromyographic study of the long-term effects of an occlusal splint on the temporal and masseter muscles in patients with functional disorders and nocturnal bruxism. J Oral Rehabil 1986;13:137-45.   DOI
9 al-Quran FA, Lyons MF. The immediate effect of hard and soft splints on the EMG activity of the masseter and temporalis muscles. J Oral Rehabil 1999;26:559-63.   DOI   ScienceOn
10 Klasser GD, Greene CS. Oral appliances in the management of temporomandibular disorders. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009;107:212-23.   DOI   ScienceOn
11 Wright E, Anderson G, Schulte J. A randomized clinical trial of intraoral soft splints and palliative treatment for masticatory muscle pain. J Orofac Pain 1995;9:192-9.
12 Wright EF. Using soft splints in your dental practice. Gen Dent 1999;47:506-10.
13 Giedrys-Leeper E. Night guards and occlusal splints. Dent Update 1990;17:325-9.
14 Yap AU. Effects of stabilization appliances on nocturnal parafunctional activities in patients with and without signs of temporomandibular disorders. J Oral Rehabil 1998;25:64-8.   DOI   ScienceOn
15 Williamson EH, Lundquist DO. Anterior guidance: its effect on electromyographic activity of the temporal and masseter muscles. J Prosthet Dent 1983;49:816-23.   DOI   ScienceOn
16 Fitins D, Sheikholeslam A. Effect of canine guidance of maxillary occlusal splint on level of activation of masticatory muscles. Swed Dent J 1993;17:235-41.
17 Sheikholeslam A, Holmgren K, Riise C. Therapeutic effects of the plane occlusal splint on signs and symptoms of craniomandibular disorders in patients with nocturnal bruxism. J Oral Rehabil 1993;20:473-82.   DOI   ScienceOn
18 McCarroll RS, Naeije M, Kim YK, Hansson TL. Short-term effect of a stabilization splint on the asymmetry of submaxi- mal masticatory muscle activity. J Oral Rehabil 1989;16:171-6.   DOI
19 Okeson JP. The effects of hard and soft occlusal splints on nocturnal bruxism. J Am Dent Assoc 1987;114:788-91.   DOI
20 Roark AL, Glaros AG, O'Mahony AM. Effects of interocclusal appliances on EMG activity during parafunctional tooth contact. J Oral Rehabil 2003;30:573-7.   DOI   ScienceOn
21 Holmgren K, Sheikholeslam A, Riise C. Effect of a full-arch maxillary occlusal splint on parafunctional activity during sleep in patients with nocturnal bruxism and signs and symptoms of craniomandibular disorders. J Prosthet Dent 1993;69:293-7.   DOI   ScienceOn
22 Zarb GA, Speck JE. The treatment of temporomandibular joint dysfunction: a retrospective study. J Prosthet Dent 1977;38:420-32.   DOI   ScienceOn
23 Dylina TJ. A common-sense approach to splint therapy. J Prosthet Dent 2001;86:539-45.   DOI   ScienceOn
24 Al-Saad M, Akeel RF. EMG and pain severity evaluation in patients with TMD using two different occlusal devices. Int J Prosthodont 2001;14:15-21.
25 Harada T, Ichiki R, Tsukiyama Y, Koyano K. The effect of oral splint devices on sleep bruxism: a 6-week observation with an ambulatory electromyographic recording device. J Oral Rehabil 2006;33:482-8.   DOI   ScienceOn
26 Kurita H, Ikeda K, Kurashina K. Evaluation of the effect of a stabilization splint on occlusal force in patients with masticatory muscle disorders. J Oral Rehabil 2000;27:79-82.   DOI   ScienceOn
27 Roark AL, Glaros AG, O'Mahony AM. Effects of interocclusal appliances on EMG activity during parafunctional tooth contact. J Oral Rehabil 2003;30:573-7.   DOI   ScienceOn
28 Hiyama S, Ono T, Ishiwata Y, Kato Y, Kuroda T. First night effect of an interocclusal appliance on nocturnal masticatory muscle activity. J Oral Rehabil 2003;30:139-45.   DOI   ScienceOn
29 Bonfante G, Ramos Júnior L, Bonfante EA. Restoration of canine guidance on an occlusal splint using amalgam: a clinical report. J Prosthet Dent 2003;90:420-3.   DOI   ScienceOn
30 Pettengill CA, Growney MR Jr, Schoff R, Kenworthy CR. A pilot study comparing the efficacy of hard and soft stabilizing appliances in treating patients with temporomandibular disorders. J Prosthet Dent 1998;79:165-8.   DOI   ScienceOn
31 Cosme DC, Baldisserotto SM, Canabarro Sde A, Shinkai RS. Bruxism and voluntary maximal bite force in young dentate adults. Int J Prosthodont 2005;18:328-32.