• 제목/요약/키워드: Occlusal contact area

검색결과 50건 처리시간 0.025초

Overdenture 하에서 하악응력 및 의치의 변위에 관한 유한요소법적 분석 (FINITE ELEMENT ANALYSIS OF MANDIBULAR STRESSES AND DENTURE MOVEMENTS INDUCED BY OVERDENTURES)

  • 김정희;정재헌;조규종
    • 대한치과보철학회지
    • /
    • 제28권1호
    • /
    • pp.63-94
    • /
    • 1990
  • The purpose of this study was to analyze the displacement and the magnitude and the mode of distribution of the stresses in the lower overdenture, the mucous membrane, the abutment tooth and the mandibular supporting bone when various denture base materials, such as acrylic resin and 0.5mm metal base, and various denture base designs were subjected to different loading schemes. For this study, the two-dimensional finite element method was used. Mandibular arch models, with only canine remaining, were fabricated. In the first denture base design, a space, approximately 1mm thick, was prepared between the denture and the dome abutment. In the second denture base design, contact between the denture and the dome abutment was eliminated except the contact of the occlusal third of the abutment. In order to represent the same physiological condition as the fixed areas of the mandible under loading schemes, the eight nodes which lie at the mandibular angle region, the coronoid process and the mandibular condyle were assumed to be fixed. Each model was loaded with a magnitude of 10 kgs on the first molar region(P1) and 7 kgs on the central incisal region (P2) in a vertical direction. Then the force of 10 kgs was applied distributively from the first premolar to the second molar of each model in a vertical direction(P3). The results were as follows. : 1. When the testing vertical loads were given to the selected points of the overdenture, the overdenture showed the rotatory phenomenon, as well as sinking and the displacements of alveolar ridge, abutment and lower border of mandible under the metal base overdenture were less than those under the acrylic resin overdenture. 2. The maximum principal stresses(the maximum tensile stresses) being considered, high tensile stresses occured at the buccal shelf area, the posterior region of the ridge crest and the anterior border region of the mandibular ramus. 3. The minimum principal stresses(the maximum compressive stresses) being considered, high compressive stresses occured at the inferior and posterior border region of the mandible, the mandibular angle and the posterior border region of the mandibular ramus. 4. The vertical load on the central incisal region(P2) produced higher equivalent stress in the mandible than that on any other region(P1, P3) because of the long lever arm distance from the fixed points to the loading point. 5. Higher equivalent stresses were distributed throughout the metal base overdenture than the resin base overdenture under the same loading condition. 6. The case of occlusal third contact of the abutment to the denture produced higher equivalent stresses in the abutment, the mandibular area around the abutment and the overdenture than the case of a 1mm space between the denture and the abutment. 7. Without regard to overdenture base materials and designs, the amounts and distribution patterns of equivalent stresses under the same loading condition were similar in the mucous membrane.

  • PDF

치조골 높이가 다른 임프란트 주위 지지골 응력분석 (Stress Analysis on the Supporting Bone around the Implant According to the Vertical Bone Level)

  • 부수붕;정제옥;이승훈;김창현;이승호
    • 구강회복응용과학지
    • /
    • 제23권1호
    • /
    • pp.55-68
    • /
    • 2007
  • The purpose of this study was to analyze the distribution of stress in the surrounding bone around implant placed in the first and second molar region. Two different three-dimensional finite element model were designed according to vertical bone level around fixture ($4.0mm{\times}11.5mm$) on the second molar region. A mandibular segment containing two implant-abutments and a two-unit bridge system was molded as a cancellous core surrounded by a 2mm cortical layer. The mesial and distal section planes of the model were not covered by cortical bone and were constrained in all directions at the nodes. Two vertical loads and oblique loads of 200 N were applied at the center of occlusal surface (load A) or at a position of 2mm apart buccally from the center (load B). Von-Mises stresses were analyzed in the supporting bone. The results were as follows; 1. With the vertical load at the center of occlusal surface, the stress pattern on the cortical and cancellous bones around the implant on model 1 and 2 was changed, while the stress pattern on the cancellous bone with oblique load was not. 2. With the vertical load at the center of occlusal surface, the maximum von-Mises stress appeared in the outer distal side of the cortical bone on Model 1 and 2, while the maximum von-Mises stress appeared in the distal and lingual distal side of the cortical bone with oblique load. 3. With the vertical load at a position of 2 mm apart buccally from the center, there was the distribution of stress on the upper portion of the implant-bone interface and the cortical bone except for the cancellous bone, while there was a distribution of stress on the cancellous bones at the apical and lingual sides around the fixture and on the cortical bone with oblique load. 4. With the changes of the supporting bone on the second molar area, the stress pattern on the upper part of the cortical bone between two implants was changed, while the stress pattern on the cancellous bone was not. The results of this study suggest that establishing the optimum occlusal contact considering the direction and position of the load from the standpoint of stress distribution of surrounding bone will be clinically useful.

Short dental implants in the posterior maxilla: a review of the literature

  • Esfahrood, Zeinab Rezaei;Ahmadi, Loghman;Karami, Elahe;Asghari, Shima
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제43권2호
    • /
    • pp.70-76
    • /
    • 2017
  • The purpose of this study was to perform a literature review of short implants in the posterior maxilla and to assess the influence of different factors on implant success rate. A comprehensive search was conducted to retrieve articles published from 2004 to 2015 using short dental implants with lengths less than 10 mm in the posterior maxilla with at least one year of follow-up. Twenty-four of 253 papers were selected, reviewed, and produced the following results. (1) The initial survival rate of short implants in the posterior maxilla was not related to implant width, surface, or design; however, the cumulative success rate of rough-surface short implants was higher than that of machined-surface implants especially in performance of edentulous dental implants of length <7 mm. (2) While bone augmentation can be used for rehabilitation of the atrophic posterior maxilla, short dental implants may be an alternative approach with fewer biological complications. (3) The increased crown-to-implant (C/I) ratio and occlusal table (OT) values in short dental implants with favorable occlusal loading do not seem to cause peri-implant bone loss. Higher C/I ratio does not produce any negative influence on implant success. (4) Some approaches that decrease the stress in posterior short implants use an implant designed to increase bone-implant contact surface area, providing the patient with a mutually protected or canine guidance occlusion and splinting implants together with no cantilever load. The survival rate of short implants in the posterior edentulous maxilla is high, and applying short implants under strict clinical protocols seems to be a safe and predictable technique.

병적 치아 이동된 상악 전치의 치주, 보철 치료 후 10년 경과 증례 (Periodontal and prosthetic treatment of maxillary incisors with pathological tooth migration: a case report with 10-year follow-up)

  • 김소연;권은영
    • 구강회복응용과학지
    • /
    • 제38권1호
    • /
    • pp.26-33
    • /
    • 2022
  • 전치부 치간 사이 공간은 치주 환자에게 흔히 발생되는 병적 치아 이동(PTM, pathological tooth migration)과 함께 자주 관찰된다. PTM에는 다양한 교합적 요인들이 기여하는데 특히 상악 전치부에서는 과도한 교합력이 있을 때 위치 문제로 인한 불리함 때문에 치간 이개가 쉽게 발생한다. 치주 지지 조직이 소실된 치아는 의도적인 연결 고정(splinting)을 통해 지지 면적을 확장하면 안정성이 증가될 수 있다. 또한 고정성 보철물로 수복 시에는 불리한 교합을 유리한 형태로 바꿀 수 있다. 임시보철물을 통해 안정적 교합을 확보 후 이것을 최종보철물로 옮기는 일은 CAD-CAM을 통하여 가능하다. 본 증례에서는 치간 접촉이 상실된 상악 전치부에서 정확한 진단과 치료를 통해 장기적으로 안정적인 결과를 보여 소개하고자 한다.

중심위 교합에서 중심 교합으로 전위될 때의 변위량과 교합형태에 관한 비교 연구 (A COMPARATIVE STUDY OF THE AMOUNT OF DISPLACEMENT AND OCCLUSION FORMS IN THE CHANGE FROM CR TO CO)

  • 이재봉;신철호
    • 대한치과보철학회지
    • /
    • 제45권1호
    • /
    • pp.1-11
    • /
    • 2007
  • Statement of problems: The concept of CR has also changed continuously.?In order to find out the factors that affect the centric slide, studies were carried out to compare the forms of wisdom teeth eruption, lateral movement, premature contact in CR, and anterior movement. Research and statistical methods were based on the report by the 1980 Korean dental association. Material and method: In our study, 403 dentists in their twenties and dentistry students who could understand CR and CO (and who did not receive occlusal, orthodontic treatment, without extreme caries and large prosthodontic care) were compared with the 25 year old results. A segment of line parallel to the upper incisor was marked on the lower incisor. When seen laterally, a line perpendicular to the occlusal plane was drawn on the foremost area of the upper incisor. This line was extended to the lower incisor and the two points (points at the lower and upper incisors) were used as reference points for the CO. After guiding the occlusion to the CR, two lines were marked by using the same method that was used for the CO. The point in which these lines meet became the reference point of CR occlusion Results and conclusions: Results of the experiment completed in 1980 show that all 307 research members had anterior-posterior and upper-lower displacement. Displacement measurements were $0.7{\pm}0.4mm$ for the anterior-posterior displacement, $0.99{\pm}0.50mm$ for the upper-lower displacement,0.18{\pm}0.31 mm for the lateral displacement, and $1.32{\pm}0.67mm$ for the total displacement. Results of the 2006 experiment show that all 409 research members had anterior-posterior and upper-lower displacement. The anterior-posterior displacement was $1.12{\pm}0.86mm$, the upper-lower displacement was $1.02{\pm}0.71mm$, the lateral displacement was $0.61{\pm}0.56mm$, and the total displacement was $1.80{\pm}0.99mm$. No specific differences were found between each group when comparing displacement according to the forms of wisdom teeth eruption. Since 1980, the percentage of unerupted teeth has increased from 35.16% (111/307 people) to 57.5% (236/409 people). Westernization of the Korean cranial form and intraoral structure has brought about these results. In our experiment, 26.7% (109/409 people) of the subjects were cuspid guided, while 7.3% (30/409 people) were mutually guided. No specific differences were found in the amount of displacement between the two groups. Only the subjects with anteriors coming in contact made up the largest percentage group (42.3%, 173/409 people) in our study. No specific differences were found between each group.

성견 경골에서 최적화 기법을 이용하여 형상 개선된 임프란트의 조직계측학적 분석 (Histomorphometric evaluation of the implant designed by shape optimization technique)

  • 권혁락;문상권;심준성;안세영;이훈;김한성;최성호;김종관
    • Journal of Periodontal and Implant Science
    • /
    • 제34권1호
    • /
    • pp.35-48
    • /
    • 2004
  • Since the occlusal loading is transmitted to the surrounding bone, the success of an implant treatment is closely related to the distribution of the stress on the implant. The finite element analysis method is often used in order to produce a model for dispersion of stress. Assessment of the success of the implant is usually based on the degree of osseointegration which is a bone and implant surface interface. Implant used in this research was designed through the method of shape optimization after the stress on implant was anaylzed by the finite element analysis method. This study was pertinently assessed by a clinical, histologic, histomorphometric analysis after the shape optimized implant was installed on beagle dog tibia. The results are as follows 1. It clinically showed a good result without mobility and imflammatory reaction. 2. Implant was supported by dense bone and bone remodeling showed on the surrounding area of the implant 3. The average percentage of bone-implant contact was 58.1%.The percentage of bone density was 57.6%. Having above results, shape optimized implant showed the pertinence through clinical and histologic aspects. However, to use the shape optimized implant, the further experiment is required for finding problems, improvement.

경부고정(頸部固定) headgear 사용시(使用時) 안면두개골(顔面頭蓋骨)의 변위(變位)에 관(關)한 장력계측법(張力計測法) 및 유한요소법적(有限要素法的) 연구(硏究) (A FINITE ELEMENT AND STRAIN GAUGE ANALYSIS ON THE DISPLACEMENT OF CRANIOFACIAL COMPLEX WITH CERVICAL HEADGEAR)

  • 김현순;남동석
    • 대한치과교정학회지
    • /
    • 제17권2호
    • /
    • pp.185-200
    • /
    • 1987
  • This paper was undertaken to observe the displacement of craniofacial complex with cervical headgear and to compare narrowing or widening effect of palate by use of contraction or expansion face-bow, respectively. The 3-dimensional finite element method(FEM) was used for a mathematical model composed of 597 nodes and 790 elements and an electrical resistance strain gauge investigation was performed to validate the finite element model. The outer bow of cervical headgear was adjusted to be placed below the occlusal plane by $25^{\circ}$ and met the midsagittal plane by $40^{\circ}$, and was loaded 1kg on each right and left hook toward posterior direction. The results were as follows 1. Generally, the maxillary teeth and facial bone were displaced in posterior, medial and downward direction. 2. It was the maxillary 2nd bicuspid that moved bodily. 3. The craniofacial complex rotated in a clockwise direction around the rotating axis which lay from the most posterior and lowest point connecting nasal crest of maxillary bone and vomer, progressively toward a more posterior, lateral and upward direction, anterior and upper area of pterygomaxillary fissure, base of medial pterygoid plate and laterally to the contact area of zygomatic arch with squamous part of temporal bone. 4. No contraction effect was observed by contraction face-bow when compared to the standard face-bow. 5. In case of expansion face-bow, the areas of maxillary 2nd bicuspid, molars and palate were expanded remarkably.

  • PDF

하악 총의치 교합형태에 따른 하부조직에 미치는 교합력 양태의 3차원적 유합요소법 해석 (THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF MANDIBULAR STRESSES OF COMPLETE DENTURE OCCLUSION)

  • 이영수;유광희
    • 대한치과보철학회지
    • /
    • 제30권2호
    • /
    • pp.286-318
    • /
    • 1992
  • The objective of preventive dentistry is the maintenance of a healthy dentition for the life of a patient. Unfortunately, if an individual has not received the benefit of a comprehensive program of preventive dentistry and has finally reached the edentulous state, as a consequence, he receives a set of complete denture. Dentures are mechanical devices and subject to the principles of mechanics. In some cases, the general health and nutritional status of the patient are felt to be the causative factors. But, the most important thing in residual ridge resorption is felt to be caused by the unequal distribution of functional forces. This study was to analyze mandibular stresses of complete denture occlusion by three dimensional finite element method. The results were as follows ; 1. As deformation and stress distribution of the complete denture of the mandible were concentrated on the upper lingual side of the mandible, alveolar ridge resorption of the mandible occurred from lingual side to labio-buccal side. 2. Analyzing by three dimensional F. E. M., the mandible is a very effective form for tolerating stress and deformation biomechanically. 3. According to the concentration of stress distibution in the upper buccal side of the lower posteriors, buccal shelf area must be a primary stress bearing area in the lower complete denture. 4. Lower complete denture moved horizontally to the balancing side under lateral occlusal force. 5. Bilateral balanced occlusion should be constructed in the complete denture for denture stability, especially in the protrusive movement. 6. Physical property of the denture base material was as important for stress distribution in the denture base as or even more than that in the mandible. 7. Impression technique is very important because of most of stress was concentrated between them due to close contact of the mandible and the denture base.

  • PDF

내측 연결 및 외측 연결 방식으로 설계된 임플란트의 3차원적 유한요소 응력 분석 (Stress distribution of implants with external and internal connection design: a 3-D finite element analysis)

  • 정현주;양성표;박재호;박찬;신진호;양홍서
    • 구강회복응용과학지
    • /
    • 제33권3호
    • /
    • pp.189-198
    • /
    • 2017
  • 목적: 외측 육각형과 내측 원추형 연결부로 설계된 임플란트 지지 하악 구치 수복물에 교합력을 가할때 발생하는 생역학 현상을 분석하고자 한다. 연구 재료 및 방법: 외측 연결형 임플란트(EXHEX)와 내측 연결형 임플란트(INCON) 그리고 이와 결합할 해당 나사와 지대주 및 크라운을 제작하였고, 하악 무치악 치조골을 설계하였다. 각 부분을 조립하여 2종의 유한요소 모형을 제작하였다. 총 120 N 크기의 수직력(L1)과 45도 측방력(L2)을 가하였고, 유한요소 응력 분석을 시행하였다. 결과: L2 측방력 하중에 의해 발생한 최대 응력은 L1 수직력 하중에 의한 것 보다 6 - 15배 더 컸다. INCON 모델은 EXHEX 모델보다 크라운 교두부에서 2.2배 더 큰 변위량을 보여 주었다. 측방력에 의해 EXHEX 모델은 나사에서, INCON 모델은 임플란트 고정체의 상단 변연부에서 폰미세스 응력의 최대값이 관찰 되었다. INCON 모델에서는 임플란트 내부 계면에서 긴밀한 접촉이 유지 되었다. 결론: 측방력이 큰 변형과 응력을 발생하였으나, 임플란트에서의 최대 응력 발생부위는 INCON과 EXHEX 모델이 서로 상이하였다.

변색된 유전치의 순측접근에 의한 치수치료 및 레진수복 (LABIAL APPROACH OF PULP TREATMENT AND RESIN RESTORATION ON DISCOLORED NECROTIC PRIMARY ANTERIOR TOOTH)

  • 채문희;송제선;최형준;김성오
    • 대한장애인치과학회지
    • /
    • 제10권2호
    • /
    • pp.84-88
    • /
    • 2014
  • 1. 순측접근법은 치수치료를 순측으로 시행한 후 변색된 순측의 치질을 확대하여 삭제하고 레진으로 순면전체를 수복함으로써 치수치료와 동시에 심미성을 회복할 수 있다. 2. 순측으로 치수치료를 시행하므로 시야가 확보에 유리하고 기구조작이 용이해 행동조절이 잘 되지 않는 어린이에게 추천된다.