• Title/Summary/Keyword: Occlusal analysis

Search Result 455, Processing Time 0.031 seconds

Full mouth rehabilitation with vertical increase in patient with severe tooth wear using monolithic zirconia prosthetic restoration (과도한 치아마모를 보이는 환자에서 수직교합고경의 증가를 동반한 단일구조 지르코니아 보철물 전악수복)

  • Bang, Ji Won;Kim, Seong-A;Lim, Sun Yong;Lee, Yong-Sang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.4
    • /
    • pp.369-377
    • /
    • 2020
  • Gradual teeth wear is normal physiological progress, severe tooth wear can causes dysfunction, occlusal plane disharmony and esthetic problems. If additional space is needed for prosthetic restoration due to severe attrition, full mouth rehabilitation with increase of occlusal vertical dimension may be considered. In this case, 72 year old male patient with severe worn dentition, irregular gingival zenith and deep anterior bite was treated by full mouth rehabilitation for regaining the space for restoration, improving relationship and esthetic of anterior teeth. Provisional restoration obtained by systemic analysis, diagnosis and re-evaluation for a sufficient time was replicated to final restorations through double scanning technique using monolithic zirconia blocks. Satisfactory functional and esthetic outcomes were obtained.

Effect of activation and preactivation on the mechanical behavior and neutral position of stainless steel and beta-titanium T-loops

  • de Castro, Saul Matos;Moreira, Rui;Braga, Ana Cristina;Ferreira, Afonso Pinhao;Pollmann, Maria Cristina
    • The korean journal of orthodontics
    • /
    • v.45 no.4
    • /
    • pp.198-208
    • /
    • 2015
  • Objective: To quantify, for each activation, the effect of preactivations of differing distribution and intensity on the neutral position of T-loops (7-mm height), specifically the horizontal force, moment to force (M/F) ratio, and load to deflection ratio. Methods: A total 100 loops measuring $0.017{\times}0.025$ inches in cross-section were divided into two groups (n = 50 each) according to composition, either stainless steel or beta-titanium. The two groups were further divided into five subgroups, 10 loops each, corresponding to the five preactivations tested: preactivations with occlusal distribution ($0^{\circ}$, $20^{\circ}$, and $40^{\circ}$), gingival distribution ($20^{\circ}$), and occlusal-gingival distribution ($40^{\circ}$). The loops were subjected to a total activation of 6-mm with 0.5-mm iterations. Statistical analysis was performed using comprised ANOVA and Bonferoni multiple comparison tests, with a significance level of 5%. Results: The location and intensity of preactivation influenced the force intensity. For the M/F ratio, the highest value achieved without preactivation was lower than the height of the loop. Without preactivation, the M/F ratio increased with activation, while the opposite effect was observed with preactivation. The increase in the M/F ratio was greater when the preactivation distribution was partially or fully gingival. Conclusions: Depending on the preactivation distribution, displacement of uprights is higher or lower than the activation, which is a factor to consider in clinical practice.

Effect of Gum-Chewing on Facial Appearance and Stomatognathic System

  • Kim, Joo-Hwan;Park, Hae-Seo;Kim, Moon-Young;Kim, Kyung-Wook
    • Journal of Korean Dental Science
    • /
    • v.7 no.1
    • /
    • pp.16-24
    • /
    • 2014
  • Purpose: This study was planned to clarify a negative view of chewing gum due to the concern that continuous gum chewing might cause a change in the gonial angle and make the lower facial appearance look square. Materials and Methods: We had 25 adults (13 males and 12 females, with an average of 27.3 years) chew 6 g of gum (spearmint) evenly with both right and left posterior teeth for one hour per day for three months. We then measured their gonial angle, the inclination of occlusal plane, facial height, bone marrow density, and masticatory force before chewing, 1, 2, and 3 month after chewing to verify its significance statistically. Result: The results showed that the gonial angle increased from $122.7^{\circ}$ to $123.3^{\circ}$ (P>0.05), and thus the jaws became slightly slimmer. There was no change in the occlusal plane inclination and facial height. Meanwhile bone marrow density in the mandibular angle and ascending ramus increased from $0.285g/cm^2$ to $0.290g/cm^2$ (P<0.05), and masticatory force also increased by 0.5 kg on the right side and 0.8 kg on the left side (P<0.05). Conclusion: Continuous chewing of gum gives an appropriate exercise effect to the stomatognathic system. As chewing gum has effect on increase bone marrow density without changing the mandibular angle and facial appearance the claim that jaw bone changes to a square jaw through chewing gum is regarded to be groundless.

Marginal and internal fit of nano-composite CAD/CAM restorations

  • Park, So-Hyun;Yoo, Yeon-Jee;Shin, Yoo-Jin;Cho, Byeong-Hoon;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.1
    • /
    • pp.37-43
    • /
    • 2016
  • Objectives: The purpose of this study was to compare the marginal and internal fit of nano-composite CAD-CAM restorations. Materials and Methods: A full veneer crown and an mesio-occluso-distal (MOD) inlay cavity, which were prepared on extracted human molars, were used as templates of epoxy resin replicas. The prepared teeth were scanned and CAD-CAM restorations were milled using Lava Ultimate (LU) and experimental nano-composite CAD/CAM blocks (EB) under the same milling parameters. To assess the marginal and internal fit, the restorations were cemented to replicas and were embedded in an acrylic mold for sectioning at 0.5 mm intervals. The measured gap data were pooled according to the block types and measuring points for statistical analysis. Results: Both the block type and measuring point significantly affected gap values, and their interaction was significant (p = 0.000). In crowns and inlays made from the two blocks, gap values were significantly larger in the occlusal area than in the axial area, while gap values in the marginal area were smallest (p < 0.001). Among the blocks, the restorations milled from EB had a significantly larger gap at all measuring points than those milled from LU (p = 0.000). Conclusions: The marginal and internal gaps of the two nano-composite CAD/CAM blocks differed according to the measuring points. Among the internal area of the two nano-composite CAD/CAM restorations, occlusal gap data were significantly larger than axial gap data. The EB crowns and inlays had significantly larger gaps than LU restorations.

Contour of lingual surface in lower complete denture formed by polished surface impression

  • Heo, Yu-Ri;Kim, Hee-Jung;Son, Mee-Kyoung;Chung, Chae-Heon
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.6
    • /
    • pp.472-478
    • /
    • 2016
  • PURPOSE. The aim of this study was to analyze the shapes of lingual polished surfaces in lower complete dentures formed by polished surface impressions and to provide reference data for use when manufacturing edentulous trays and lower complete dentures. MATERIALS AND METHODS. Twenty-six patients with mandibular edentulism were studied. After lower wax dentures were fabricated, wax was removed from the lingual side of the wax denture and a lingual polished surface impression was obtained with tissue conditioner. The definitive denture was scanned with a three-dimensional scanner, and scanned images were obtained. At the cross-sections of the lingual frenum, lateral incisors, first premolars, first molars, and anterior border of the retromolar pads, three points were marked and eight measurements were taken. The Kruskal-Wallis test and a post hoc analysis with the Mann-Whitney test were performed. RESULTS. Each patient showed similar values for the same areas on the left and right sides without a statistically significant difference. The height of the contour of the lingual polished surface at the lingual frenum was halfway between the occlusal plane and lingual border, it moved gradually in a downward direction. The angle from the occlusal plane to the height of the contour of the lingual polished surface was increased as it progressed from the lingual frenum towards the retromolar pads. CONCLUSION. The shape of the mandibular lingual polished surface was convex at the lingual frenum, lateral incisors and gradually flattened towards the first molars and retromolar pads.

THE MARGINAL SEALING EFFECT OF COMPOSITE RESIN INLAYS ACCORDING TO THE LUTING TECHNIQUES (합착방법(合着方法)에 따른 복합(複合)레진 인레이의 변연폐쇄효과(邊緣閉鎖效果))

  • Moon, Young-Deok;Cho, Kyeu-Zeung
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.1
    • /
    • pp.121-132
    • /
    • 1991
  • The purpose of the study was to evaluate the marginal sealing effect of composite resin inlays according to the luting techniques and compare them to the conventional direct resin filling technique. 90 cavities of class V were prepared on the buccal surface of 90 extracted molar teeth, which were divided into four groups. Cavities of control group were directly filled with Scotchbond 2 and P - 50, and those of composite resin inlay groups were luted with one of the followings: Adhesive bond followed by Adhesive cement, All bond followed by Adhesive cement, Fuji - ionomer type L All the specimens were immersed in India ink dye solution for 7 days at $37^{\circ}C$ incubator after thermocycling between $5^{\circ}C$ and $60^{\circ}C$ and longitudinally sectioned with diamond disk inot two parts All the specimens were observed at the occlusal and gingival margins and statistical analysis was performed. The results were as follows: 1. Groups filled with composite resin inlay showed less marginal leakage than the group directly filled(p<0.01). 2. There was no significant difference in marginal leakage between composite resin inlay groups luted with Adhesive bond followed by Adhesive cement and the group luted with All bond followed by Adhesive cement(p>0.05). 3. At occlusal margins, Composite resin inlay group luted with Adhesive bond followed by Adhesive cement showed less marginal leakage than the group luted with Fuii ionomer type I(p<0.01). At gingival margins, composite resin inlay group luted with All bond followed by Adhesive cement showed less marignal leakage than the group luted with Fuji ionomer type I(P<0.01).

  • PDF

PHOTOELASTIC STRESS ANALYSIS OF LOAD TRANSFER TO SATELLITE ABUTMENT AS AN IMMEDIATE ABUTMENT (인공치아의 즉시부하를 위해 새로이 개발된 인공치아 지대주(Satellite Abutment)의 광탄성 응력 분석)

  • Park, Sang-Kyu;Lee, Baek-Soo;Engelke, W;Kim, Boo-Dong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.6
    • /
    • pp.472-479
    • /
    • 2002
  • Since $Br^{\circ}anemark$ introduced the osseointegrated implants, they have been granted for useful methods for the restoration of oral function. The original $Br^{\circ}anemark$ protocol recommended long stress-free healing periods to achieve the osseointegration of dental implants. However, many clinical and experimental studies have shown that the osseointegration is no wonder in almost cases and that early and immediate loading may lead to predictable osseointegration. So we are willing to introduce the Satellite Abutment newly invented for immediate loading. We think that it will make the occlusal forces dispersed to surrounding bone and that we can restore the oral function immediately after implant installation not disturbing osseointegration. In case of using Satellite abutment, stress concentrated to bone contact area of implant was distributed not only fixation plate and screws but also superior, middle portion of implant and cortical layer of jaw bone. It was clearly decreased on the bone contact surfaces around dental implants. 1. Stress was decreased more than 76.5% when satellite straight abutment was used. 2. Stress was decreased more than 50% when satellite angled abutment was used. 3. The stress around dental implant was well distributed along the cortical bone surface and the fixation plate and screw. This study concludes that satellite abutment can be used as all immediate loading implant prothesis because it was possible to distribute periimplant occlusal stress through implant contact bone surface and cortical layer of jaw bone.

Full mouth rehabilitation on the patient with severe tooth wear and tooth fracture using reestabilishment of occlusal vertical dimension (심한 치아 마모 및 파절 환자의 수직고경거상을 동반한 전악 수복 증례)

  • Lee, Ho-Sun;Joo, Se-Jin;Jin, Soo-Yoon;Kang, Dong-Wan;Lee, Gyeong-Je
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.224-231
    • /
    • 2016
  • Severe dental attrition causes pathological changes of the tooth, imbalanced occlusion, and functional and aesthetic complications and can also result in a decrease in occlusal vertical dimension that can incur temporomandibular joint and muscular complications. Before restoring the vertical dimension with full-mouth prosthetic restorations, it is important to determine the amount of vertical lifting through complete diagnosis. In this study, a 59 year-old male patient with generalized attrition and fracture of teeth was treated with full-mouth zirconia prosthetic restoration in order to recover vertical dimension and aesthetics. Through the analysis of physiologic rest position and inter-canine distance, the treatment was planned for lifting 3 mm in vertical dimension. Interim crown were fabricated after full-mouth wax up, having the patient use for 6 months. The final monolithic and bilayered zirconia restorations were completed. The patient showed satisfaction in function and aesthetics for 18 months of follow-up since delivering the final restorations.

Evaluation of mandibular lingula and foramen location using 3-dimensional mandible models reconstructed by cone-beam computed tomography

  • Zhou, Cong;Jeon, Tae-Hyun;Jun, Sang-Ho;Kwon, Jong-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.39
    • /
    • pp.30.1-30.7
    • /
    • 2017
  • Background: The positions of the mandibular lingula and foramen have been set as indexes for inferior alveolar nerve (IAN) block and ramus osteotomies in orthognathic surgery. This study aimed to evaluate the anatomical structures of mandibular ramus, especially the mandibular lingula and foramen, by analyzing the cone-beam computed tomography (CBCT) data of young adults. Methods: We evaluated 121 sides of hemi-mandibular CBCT model of 106 patients (51 male and 55 female patients; 18 to 36 years old). All the measurements were performed using the 2- and 3-dimensional rulers of $OnDemand3D^{(R)}$ software. Results: Statistical analysis of the data revealed that there was no significant difference in the mandibular angle between the genders. The mandibular lingula was found to be located at the center of ramus in males, but a little posterior in relation to the center in females. The mandibular lingula was rarely located below the occlusal plane; however, the position of the mandibular foramen was more variable (84.3% below, 12.4% above, and 3.3% at the level of the occlusal plane). Conclusions: The results of this study provide a valuable guideline for IAN block anesthesia and orthognathic surgery. CBCT can be considered effective and accurate in evaluating the fine structures of the mandible.

In-vitro development of a temporal abutment screw to protect osseointegration in immediate loaded implants

  • Garcia-Roncero, Herminio;Caballe-Serrano, Jordi;Cano-Batalla, Jordi;Cabratosa-Termes, Josep;Figueras-Alvarez, Oscar
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.2
    • /
    • pp.160-165
    • /
    • 2015
  • PURPOSE. In this study, a temporal abutment fixation screw, designed to fracture in a controlled way upon application of an occlusal force sufficient to produce critical micromotion was developed. The purpose of the screw was to protect the osseointegration of immediate loaded single implants. MATERIALS AND METHODS. Seven different screw prototypes were examined by fixing titanium abutments to 112 Mozo-Grau external hexagon implants (MG Osseous$^{(R)}$; Mozo-Grau, S.A., Valladolid, Spain). Fracture strength was tested at $30^{\circ}$ in two subgroups per screw: one under dynamic loading and the other without prior dynamic loading. Dynamic loading was performed in a single-axis chewing simulator using 150,000 load cycles at 50 N. After normal distribution of obtained data was verified by Kolmogorov-Smirnov test, fracture resistance between samples submitted and not submitted to dynamic loading was compared by the use of Student's t-test. Comparison of fracture resistance among different screw designs was performed by the use of one-way analysis of variance. Confidence interval was set at 95%. RESULTS. Fractures occurred in all screws, allowing easy retrieval. Screw Prototypes 2, 5 and 6 failed during dynamic loading and exhibited statistically significant differences from the other prototypes. CONCLUSION. Prototypes 2, 5 and 6 may offer a useful protective mechanism during occlusal overload in immediate loaded implants.