• 제목/요약/키워드: Observed discharge

검색결과 1,240건 처리시간 0.026초

극저온중 고분자 Film의 부분방전 연구 (A Study on Partial Discharge of Polymer Film at Cryogenic Temperature)

  • 김상현;마대영;김현희;김영석;조강욱;최효상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 춘계학술대회 논문집
    • /
    • pp.178-184
    • /
    • 1996
  • Electrical properties such as surface flashover discharge and discharge degradations of insulating materials for superconducting cable have been investigated. It is found that the surface voltage is proportional to /$\^$0.7/(/: discharge length) in LHe(Liquid Helium). V-t characteristic LHe were a n=5.5 that was less than liquid N$_2$. After applied AC voltage, the surface condition of polymer films were observed non-eroded area and eroded area. The eroded area is depending on the applied voltage. In case of LHe, the crack was observed.

  • PDF

휴대전자기기용 저용량 리튬이온 배터리의 충방전 열화 기구 분석 및 모니터링 (Evaluation and monitoring of degradation mechanism of Li-ion battery for portable electronic device)

  • 변재원
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제13권2호
    • /
    • pp.129-140
    • /
    • 2013
  • As a fundamental experimental study for reliability improvement of lithium ion secondary battery, degradation mechanism was investigated by microscopic observation and acoustic emission monitoring. Microstructural observation of the decomposed battery after cycle test revealed mechanical and chemical damages such as interface delamination, microcrack of the electrodes, and solid electrolyte interphase (SEI). Acoustic emission (AE) signal was detected during charge and discharge of lithium ion battery to investigate relationships among cumulative count, discharge capacity, and microdamages. With increasing number of cycle, discharge capacity was decreased and AE cumulative count was observed to increase. Observed damages were attributed to sources of the detected AE signals.

저압 열전자 방전 플라즈마의 Monte Carlo 시뮬레이션 (Monte Carlo Simulation of Thermionic Low Pressure Discharge Plasma)

  • 고욱희
    • 전기학회논문지
    • /
    • 제61권12호
    • /
    • pp.1880-1885
    • /
    • 2012
  • Nonlinear dynamical behaviors in thermionic low pressure discharge are investigated using a particle-in-cell(PIC) simulation. An electrostatic PIC code is developed to model the plasma discharge system including the kinetic effects. The elastic collision, excitation collision, ionization collision, and electron-ion recombination collision are considered in this code. The generated electrons and ions are traced to analyze physical characteristics of the plasma. The simulation results show that the nonlinear oscillation structures are observed for cold plasma in the system and the similar structures are observed for warm plasma with a shift in values of the bifurcation parameter. The detailed oscillation process can be subdivided into three distinct mode; anode-glow, temperature-limited, and double-layer modes.

Observation of Discharge Plasma of Liquid Propellant PPT

  • Koizumi, Hiroyuki;Ruruta, Yohei;Watanabe, Keiko;Komurasaki, Kimiya;Sasoh, Akihiro;Arakawa, Yoshihiro
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.335-340
    • /
    • 2004
  • On a liquid propellant PPT, the discharge processes that discharge was initiated and plasma was accelerated was observed by using a ultra high speed camera. Liquid propellant PPT is a pulsed plasma thruster using liquid as propellant. Our past study showed the successful operation of liquid propellant PPT and the thruster showed high specific impulse. However, its acceleration mechanism has not been clarified. In this study we observed the plasma acceleration processes in order to deepen our understanding of the acceleration mechanism.

  • PDF

플라즈마진동을 이용한 기체크로마토그래프의 검출기에 대한 연구 (Study on the Plasma Oscillation for Gas Chromatographic detector)

  • 김효진;맹대영;강종성
    • 분석과학
    • /
    • 제6권4호
    • /
    • pp.369-374
    • /
    • 1993
  • 플라즈마 진동 현상은 글로우방전을 이용한 기체크로마토그래프 검출기의 개발 과정에서 측정되었으며 전류의 변화에 비하여 매우 안정하며 낮은 검출한계로 새로운 검출기로의 개발 가능성이 높다. 플라즈마 진동의 최적 조건과 메카니즘을 규명하기 위하여 몇 가지 실험조건을 변화시키며 관찰하였다. 즉, 방전전압(전류), 압력, 그리고 방전전극 간격을 변화시킨 결과 다양한 형태의 진동이 10KHz에서 10MHz까지의 주파수 범위에서 관찰되었다. 특히 방전전극 간격에 따라 낮은 압력과 전압의 조건에서 두 가지 형태의 진동이 나타났다. 한 가지 형태는 positive column 영역에서, 또 다른 하나는 negative glow 영역에서 측정되었다. Positive column 영역보다 negative glow 영역에서 발생된 플라즈마 진동이 훨씬 더 높은 감도 변화와 더 큰 주파수를 보였다.

  • PDF

글로우방전을 이용한 액체크로마토그라피 검출기 개발을 위한 기초특성연구 (Fundamental Studies of the Electrical Characteristics of the Glow Discharge for the Development of HPLC Detector)

  • 이현주;김효진
    • 약학회지
    • /
    • 제39권4호
    • /
    • pp.427-432
    • /
    • 1995
  • The plasma oscillation has been observed in an argon pressure between a tungsten anode and cathode consisting of an aqueous conducting solution. The effects of experimental parameters on the electrical characteristics of the glow discharge have been studied. The experimental parameters include the anode-cathode distance, pressure, methanol flow rate, and cathode materials. The glow discharge with liquid cathode and solid anode showed the potential sensitive detector for HPLC

  • PDF

하천유량 측정기법에 관한 연구 (A Study on the River Discharge Measurement Techniques)

  • 김성원;지홍기
    • 한국환경과학회지
    • /
    • 제7권6호
    • /
    • pp.793-801
    • /
    • 1998
  • In this study, the Dilution Method is used to measure river discharge through the hydraulic model test. the dilution method is divided into Constant-Rate-Infection Method and Slug-Injection Method in the river discharge measurement techniques. When the dilution method is applied in the hydraulic model flume, it is analyzed that the estimated error of constant-rate-injection method is less than that of the slug-in-jection method, and the result shows that floodflow analysis is more efficient than lowflow analysis as compared observed discharge with calculated discharge. The result of statistical error analysis shows that the constant-rate-injection method is appropriate technique for the measurement of the river discharge. Therefore, the dilution method among the river discharge measurement techniques can be applied for the river basin which can't be measured with current meter or unsteady-flow regime in the urban-small drainage or hydraulic structure equipment area and can be obtained more exact results than any other discharge measurement techniques.

  • PDF

양산천 수위-유량관계 특성에 관한 현장관측 분석 (Analysis of Field Observations on Characteristics of Stage-Discharge Relationshiup for Yangsan River)

  • 이용희;이상배
    • 한국항만학회지
    • /
    • 제14권1호
    • /
    • pp.107-114
    • /
    • 2000
  • Derivation of stage-discharge relationship and characteristics for Yangsan river is presented in this paper. This research has been conducted as the second one after the first trial in 1997. The determination of discharge at a Yangsan river gauging was best made by measuring the flow velocities with a current meter and rod float. The rating curve obtained through 52 stage-discharge measurements on Yangsan river basin in 1999 is represented by Q=15.3540-140.6076H+182.44372H$^2$, which is discovered to be most excellent among other curves in reliability analysis. The observed stage-discharge data for Yangsan river was tested by HEC-RAS program, and reproduction of discharge by the induced curve was investigated and compared with the computational results. The rating curve of Yangsan river shows characteristics of Yangsan river more accurately compared with those separated in terms of water levels.

  • PDF

무성방전내에서 톨루엔 제거에 미치는 운전변수의 영향 (Effects of Operating Parameters on Toluene Removal in Dielectric Barrier Discharge Process)

  • 정재우;이용환;박경렬
    • 한국대기환경학회지
    • /
    • 제18권3호
    • /
    • pp.173-182
    • /
    • 2002
  • We investigated the effects of operating variables, such as electrical. reactor and gas parameters on toluene removal and discharge property in the dielectric barrier discharge (DBD) process. The toluene removal was initiated with the energy transfer to the reactor by loading of voltages higher than the discharge onset value. The energy transfer and toluene removal increased with the applied voltage. Higher removal rate was observed with smooth surface electrode despite of lower energy transfer compared with the coarse electrode, because more uniform discharge can be obtained on smooth surface state. The decrease of dielectric material thickness enhanced the removal efficiency by increasing the discharge potential. The toluene removal efficiency decreased with the increase of the inlet concentration. The increase of gas retention time enhanced the removal efficiency by the increase of energy density. The oxygen and humidity contents seem to exert significant influences on the toluene removal by dominating the generation of electrons, ions, and radicals which are key factors in the removal mechanism.

ADCP를 활용한 제주 강정천의 평균유속 분포 추정 (A Study on the Mean Flow Velocity Distribution of Jeju Gangjung-Stream using ADCP)

  • 양세창;김용석;양성기;강명수;강보성
    • 한국환경과학회지
    • /
    • 제26권9호
    • /
    • pp.999-1011
    • /
    • 2017
  • In this study, the Chiu-2D velocity-flow rate distribution based on theoretical background of the entropy probability method was applied to actual ADCP measurement data of Gangjung Stream in Jeju from July 2011 to June 2015 to predict the parameter that take part in velocity distribution of the stream. In addition, surface velocity measured by SIV (Surface Image Velocimeter) was applied to the predicted parameter to calculate discharge. Calculated discharge was compared with observed discharge of ADCP observed during the same time to analyze propriety and applicability of depth of water velocity average conversion factor. To check applicability of the predicted stream parameter, surface velocity and discharge were calculated using SIV and compared with velocity and flow based on ADCP. Discharge calculated by applying velocity factor of SIV to the Chiu-2D velocity-flow rate distribution and discharge based on depth of water velocity average conversion factor of 0.85 were $0.7171m^3/sec$ and $0.5758m^3/sec$, respectively. Their error rates compared to average ADCP discharge of $0.6664m^3/sec$ were respectively 7.63% and 13.64%. Discharge based on the Chiu-2D velocity-flow distribution showed lower error rate compared to discharge based on depth of water velocity average conversion factor of 0.85.