• Title/Summary/Keyword: Observation of Microstructure

Search Result 380, Processing Time 0.023 seconds

Influence of Post-Sintering Annealing Conditions on the Microstructure and Magnetic Properties of Nd-Fe-B Magnet (Nd-Fe-B 소결자석의 소결 후 열처리 조건에 따른 미세조직 및 자기적 특성 변화)

  • Yunjong Jung;Soonjik Hong;Dong-Hwan Kim;Kyoung-Hoon Bae;Gian Song
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.37 no.1
    • /
    • pp.9-15
    • /
    • 2024
  • Nd-Fe-B permanent magnets have been utilized on various industrial fields such as electric vehicles, generator, robots with actuator, etc, due to their outstanding magnetic properties even 10 times better than conventional magnets. Recently, there are many researches that report magnetic properties improved by controlling microstructure through adjusting alloying elements or conducting various processing. Especially, post-sintering annealing (PSA) can significantly improve the coercivity by modifying the distribution and morphology of Nd-rich phase which formed at grain boundaries. In this study, Nd-Fe-B sintered magnets were subjected to primary heat treatment followed by secondary heat treatment at 460℃, 500℃, and 540℃ to investigate the changes in microstructure and magnetic properties with the secondary heat treatment temperature. EBSD analysis was conducted to compare anisotropic characteristics. Through the SEM and TEM observation for analyzing the morphology and distribution of Nd-rich phase, we investigated the relationship between microstructure and magnetic properties of sintered Nd-Fe-B magnets.

Surface Reaction between Phosphate bonded $SiO_2$ Investment and Ti-Zr-(Cu) based Alloys for Dental castings (인산염계 $SiO_2$ 주형재와 치과주조용 Ti-Zr-(Cu)계 합금의 계면반응)

  • Joo, Kyu-Ji
    • Journal of Technologic Dentistry
    • /
    • v.27 no.1
    • /
    • pp.57-63
    • /
    • 2005
  • Experimental Ti-13%Zr and Ti-13%Zr-5%Cu alloys were made in an argon-arc melting furnace. The grade 2 CP Ti was used to control. To investigate the surface reaction layers produced by the reaction with mold materials and the influence of the reaction layers on the hardness of castings, A phosphate bonded $SiO_2$ base investment was used as mold material, and microstructure observation and hardness test were performed. The surface reaction layers of Ti-13%Zr and Ti-13%Zr-5%Cu alloys were thinner than that of CP Ti had a clearly multiple structure. A difference of the hardness between surface and inner of the Ti-13%Zr and Ti-13%Zr-5%Cu alloys became less than that of CP Ti. From the results, it was found that the Ti-Zr-(Cu) based alloys were possible to cast with $SiO_2$ base investment without the great changes of mechanical properties of the castings.

  • PDF

Dynamic recrystallization and microstructure evolution of a Nb-V microalloyed forging steel during hot deformation

  • Zhao, Yang;Chen, Liqing;Liu, Xianghua
    • Advances in materials Research
    • /
    • v.3 no.4
    • /
    • pp.217-225
    • /
    • 2014
  • In this study, a forging steel alloyed with both Nb and V was used as experimental material and the hot deformation behavior has been studied for this steel by conducting the compressive deformation test at temperature of $900-1150^{\circ}C$ and strain rate of $0.01-0.01s^{-1}$ in a MMS-300 thermo-mechanical simulator. The microstructure evolution, particularly the dynamically recrystallized microstructure, of the experimental steel at elevated temperatures, strain rates and strain levels, was characterized by optical microstructural observation and the constitutive equation in association with the activation energy and Zener-Hollomon parameter. The curves of strain hardening rate versus stress were used to determine the critical strain and peak strain, and their relation was connected with Zener-Hollomon parameter. Under the conditions of processing temperature $900^{\circ}C$ and strain rate $0.01s^{-1}$, the dynamic recrystallization took place and the austenite grain size was refined from $164.5{\mu}m$ to $28.9{\mu}m$.

Effect Of The Microstructure And Aging Treatment Conditions On Strength Of High Strength Invar Alloy (고강도 인바합금의 강도에 미치는 미세구조와 시효처리 조건의 영향)

  • Jung, J.Y.;Lee, K.D.;Ha, T.K.;Jeong, H.T.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2007.10a
    • /
    • pp.322-325
    • /
    • 2007
  • Precipitation characteristics of the Fe-36Ni based high strength Invar alloy for power transmission wire was investigated in this study. High strength can be obtained in this alloy through solution hardening, precipitation hardening and strain hardening by cold working. In the present study, ingots of Fe-36Ni based Invar alloys with the contents of C, Mo and V varied. Microstructure observations by OM, SEM, and TEM were carried out to validate the simulation results. BCC phase and $FeNi_3$ phase are also expected at lower temperatures below $500^{\circ}C$. Aging treatments were carried out at temperatures ranging from 400 to $900^{\circ}C$ for time intervals from 3 min to 100hrs. Peak aging condition was obtained as $400^{\circ}C$ and 1 hr. With temperature increased, peak strength was decreased abruptly. Microstructure observation was conducted by optical microscopy, scanning electron microscopy, and transmission electron microscopy.

  • PDF

A Study on the 43$0^{\circ}C$ Degradation Behavior of Cast Stainless Steel(CF8M)(I);Evaluation of Degradation mechanism, Static and Fatigue Strength (주조 스테인리스강 CF8M의 43$0^{\circ}C$ 열화거동에 관한 연구(I);열화기구.정적 및 피로강도평가)

  • Gwon, Jae-Do;Park, Jung-Cheol;Lee, Yong-Seon;Lee, U-Ho;Park, Yun-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.8 s.179
    • /
    • pp.1910-1916
    • /
    • 2000
  • The five classes of the thermally aged CF8M specimen are prepared using an artificially accelerated aging method. Namely, after the specimens are held for 100, 300, 900, 1800, and 3600hrs at 430$^{\circ}C$ respectively, the specimens are water-cooled to room temperature. The impact energy variations are measures for both the aged and virgin specimens through the Charpy impact tests in addition to the microstructure observation, tensile, hardness and fatigue crack growth tests. From the present investigation the following results are obtained : 1) The difference among the thermally degraded specimens can be distinguished through their microstructures, 2) Hardness and tensile strength are increased to 300hrs, degradation specimen, while elongation and reduction area are decreased to 3600hrs degradation specimen, and impact energy is decreased to 1800hrs degradation specimen, 3) The FCG rates for thermally degraded specimens are larger than that of the virgin specimen.

Failure Analysis of Carburized Gears by Microstructural Observation (침탄처리된 기어의 미세 조직학적 손상 원인분석)

  • Chun, Hae Dong;Chang, Sung Ho;Kim, Kyung Wook;Kuk, Youn Ho
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.27 no.4
    • /
    • pp.191-201
    • /
    • 2014
  • The gear was made of SNC815 case-carburized, quench hardened and tempered steel. The gears were failed far earlier than the expected service life used in the industrial site. Causes of the failed gear were analyzed by microstructure observation. By the SEM and micro structure examinations, the damaged surfaces had been weared and failed by fatigue. Through microscope observation on the damaged surface, it was found that the cause of failure was determined by external overloading and the initial stage of the damage was closely related to complex contact fatigue failure. The overload and contact fatigue contributed to the early failure cause.

Failure Analysis of the Carburized Engine Parts by Microstructural Observation (침탄처리된 엔진 부품의 미세조직학적 파손원인 분석)

  • Sohn, Kyong-Suk;Lee, Sang-Kee;Chung, In-Sang
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.18 no.2
    • /
    • pp.83-90
    • /
    • 2005
  • Failure cause of the fractured engine parts was analyzed by microstructural observation. These parts were failed far earlier than the expected service life. By the stereoscope and SEM examinations of the fractured surface, the fracture modes have been identified as wear and fatigue failure. From the observation of microstructure and microhardness measurements of the failed gears, the probable cause for failures are internal oxidation during using and retained austenite and carbide networks due to heat-treatment, respectively. These defected structures at near surface contributed to the wear and fatigue failure.

Hardness of Constituent Phases in Ti(C0.7N0.3)-WC-Ni Cermets Measured by Nanoindentation (나노인덴테이션으로 측정한 Ti(C0.7N0.3)-WC-Ni 써멧 구성상의 경도)

  • Kim, Seong-Won;Kim, Dae-Min;Kang, Shin-Hoo;Kim, Hyeong-Jun;Kim, Hyung-Tae
    • Journal of the Korean Ceramic Society
    • /
    • v.46 no.1
    • /
    • pp.116-121
    • /
    • 2009
  • The constituent phases in Ti($C_{0.7}N_{0.3}$)-xWC-20Ni (wt%, x=5, 15, 25) cermets were characterized using nanoindentation in conjunction with observation of microstructure. The microstructure of cermet is composed of hard phase and binder phase, which gave rise to a wide range of hardness distribution when nanoindentation was carried out on the polished surface of cermets. Because of the inhomogeneous nature of cermet microstructure, observation of indented surface was indispensable in order to separate the hardness of each constituent phase. The measured values of hardness using nanoindentation were ${\sim}14\;GPa$ for the binder phase and ${\sim}24$ to 28 GPa for the hard phase, of which nanoindentation hardness was decreased with the addition of WC into Ti($C_{0.7}N_{0.3}$)-Ni system. In addition, the nanoindentation hardness of Ni binder phase was much higher than reported Vickers hardness, which could result from confined deformation of binder phase due to the surrounding hard phase particles.

Influence of Incorporated Impurities on the Evolution of Microstructure in Electro-Deposited Copper Layer (혼입불순물이 구리 도금층의 미세조직변화에 미치는 영향)

  • Koo, Seok-Bon;Jeon, Jun-Mi;Lee, Chang-Myeon;Hur, Jin-Young;Lee, Hong-Kee
    • Journal of the Korean institute of surface engineering
    • /
    • v.51 no.4
    • /
    • pp.191-196
    • /
    • 2018
  • The self-annealing which leads evolution of microstructure in copper electroplating layers at room temperature occurs after forming deposition layer. During the process, crystal orientation, size and sheet resistance of plating layer change. Lastly, it causes the change of physical and mechanical characteristics such as a tensile strength of plating layer. In this study, the variation of incorporated impurities, microstructure and sheet resistance of copper plating layer formed by electroplating are measured with and without inorganic additives during the self-annealing. In case of absence of inorganic additives, the copper layer presents strong total intensity of incorporated impurities. During the self-annealing, such width of reduction was significant. Moreover, microstructure and crystal size are increased while the tensile strength is decreased noticeably. On the other hand, in the presence of inorganic additives, there is no observable distinction in the copper plating layer. According to the observation on movements of the incorporated impurities in electrodeposition copper layer, within 12 hours the impurities are continuously shifted from inside of the plating layer to its surface after as-deposited electroplating. Within 24 hours, except for the small portion of surface layer, it is considered that most of the microstructure is transformed.

The effects of tetracycline-HCI on SLA implant surface structure (염산 테트라싸이클린이 SLA 임플란트의 표면 구조에 미치는 영향)

  • Sea, Mi-Ran;Kwon, Young-Hyuk;Park, Joon-Bong;Herr, Yeek;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.2
    • /
    • pp.251-263
    • /
    • 2007
  • The present study was performed to evaluate the effects of Tetracycline-HCI on the microstructure change of SLA implant surface according to application time. In the Tetracycline-HCI group, 6 implants were rubbed with sponges soaked $50mg/m{\ell}$ Tetracycline-HCI solution for O.5min., lmin., 1. 5min., 2min., 2.5min. and 3min. In the saline group. another 6 implants conditioned with sponges soaked saline using same methods. One implant wasn't conditioned anything. Then, the changes of surface roughness values were evaluated by optical interferometer & specimens were processed for scanning electron microscopic observation. The results of this study were as follows: 1. In both Tetracycline-HCI group & saline group, there are no significant differences between surface roughness values before & after surface detoxification. And in scanning electron microscopic observation. there are slightly changes of implant surface structures but this changes were not significant by comparison with no treatment implant surface. 2. In the changes of surface roughness values & the scanning electron microscopic observation, there were no significant differences between saline & Tetracycline-HCI groups. In conclusion, the detoxification with $50mg/m{\ell}$ Tetracycline-HCI within 3 minutes can be applied for treatment of peri-implantitis in SLA surface implants. without surface microstructure changes.