• 제목/요약/키워드: Oblique Angle

검색결과 411건 처리시간 0.03초

연강 판재에 대한 연강 구의 고속경사충돌 수치해석 (Numerical Simulation of High-Velocity Oblique Impact of Mild Steel Spheres Against Mild Steel Plates)

  • 유요한;장순남;정동택
    • 대한기계학회논문집A
    • /
    • 제26권3호
    • /
    • pp.576-585
    • /
    • 2002
  • A three-dimensional Lagrangian explicit time-integration finite element code for analyzing the dynamic impact phenomena was developed. It uses four node tetrahedral elements. In order to consider the effects of strain rate hardening, strain hardening and thermal softening, which are frequently observed in high-velocity deformation phenomena, Johnson-Cook model is used as constitutive model. For more accurate and robust contact force computation, the defense node contact algorithm was adopted and implemented. In order to evaluate the performance of the newly developed three-dimensional hydrocode NET3D, numerical simulations of the oblique impact of mild steel plate by mild steel sphere were carried out. Ballistic limit about various oblique angle between 0 degree and 80 degree was estimated through a series of simulations with different initial velocities of sphere. Element eroding by equivalent plastic strain was applied to mild steel spheres and targets. Ballistic limits and fracture characteristics obtained from simulation were compared with experimental results conducted by Finnegan et al. From numerical studies, the following conclusions were reached. (1) Simulations could successfully reproduce the key features observed in experiment such as tensile failure termed "disking"at normal impacts and outwards bending of partially formed plus segments termed "hinge-mode"at oblique impacts. (2) Simulation results fur 60 degrees oblique impact at 0.70 km/s and 0.91 km/s were compared with experimental results and Eulerian hydrocode CTH simulation results. The Lagrangian code NET3D is superior to Eulerian code CTH in the computational accuracy. Agreement with the experimentally obtained final deformed cross-sections of the projectile is excellent. (3) Agreement with the experimental ballistic limit data, particularly at the high-obliquity impacts, is reasonably good. (4) The simulation result is not very sensitive to eroding condition but slightly influenced by friction coefficient.

The effects of the angles of the knee and heel-off on the muscle activity during a bridge exercise

  • Kim, Byeong-jo;Lee, Su-kyoung;Lee, Jung-hoon;Kwon, Hae-yeon
    • 대한물리의학회지
    • /
    • 제10권3호
    • /
    • pp.95-100
    • /
    • 2015
  • PURPOSE: The purpose of this study is to investigate the effects of the angles of the knee and heel-off on the muscle activity during a bridge exercise. METHODS: 15 healthy adult men and women with the balance ability and joint working range required for performing a bridge exercise participated in this study, in which $120^{\circ}$, $90^{\circ}$ and $60^{\circ}$ angles of the knee-flexion and heel-off were applied during the bridge exercise. RESULTS: Our data showed that there were significant differences in muscle activities of elector spinae and rectus abdominis when $120^{\circ}$ and $60^{\circ}$ angles of the knee were applied, of internal oblique when $120^{\circ}$ and $60^{\circ}$ were applied, and external oblique when $90^{\circ}$ and $60^{\circ}$ were applied. When heel-off was applied, there were significant differences in muscle activities of elector spinae and rectus abdominis when $120^{\circ}$ and $60^{\circ}$ were applied, of internal oblique when $120^{\circ}$ and $60^{\circ}$ were applied, and external oblique when $90^{\circ}$ and $60^{\circ}$ were applied. CONCLUSION: In this study on an application of heel-off to the bridge exercise, we showed that the effect of the angles of the knee on the muscle activities of elector spinae, rectus abdominis, internal oblique and external oblique were all similar to the regular bridge exercise, but overall muscle activities were increased with heel-off when compared with the regular bridge exercise.

Effects of implant tilting and the loading direction on the displacement and micromotion of immediately loaded implants: an in vitro experiment and finite element analysis

  • Sugiura, Tsutomu;Yamamoto, Kazuhiko;Horita, Satoshi;Murakami, Kazuhiro;Tsutsumi, Sadami;Kirita, Tadaaki
    • Journal of Periodontal and Implant Science
    • /
    • 제47권4호
    • /
    • pp.251-262
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the effects of implant tilting and the loading direction on the displacement and micromotion (relative displacement between the implant and bone) of immediately loaded implants by in vitro experiments and finite element analysis (FEA). Methods: Six artificial bone blocks were prepared. Six screw-type implants with a length of 10 mm and diameter of 4.3 mm were placed, with 3 positioned axially and 3 tilted. The tilted implants were $30^{\circ}$ distally inclined to the axial implants. Vertical and mesiodistal oblique ($45^{\circ}$ angle) loads of 200 N were applied to the top of the abutment, and the abutment displacement was recorded. Nonlinear finite element models simulating the in vitro experiment were constructed, and the abutment displacement and micromotion were calculated. The data on the abutment displacement from in vitro experiments and FEA were compared, and the validity of the finite element model was evaluated. Results: The abutment displacement was greater under oblique loading than under axial loading and greater for the tilted implants than for the axial implants. The in vitro and FEA results showed satisfactory consistency. The maximum micromotion was 2.8- to 4.1-fold higher under oblique loading than under vertical loading. The maximum micromotion values in the axial and tilted implants were very close under vertical loading. However, in the tilted implant model, the maximum micromotion was 38.7% less than in the axial implant model under oblique loading. The relationship between abutment displacement and micromotion varied according to the loading direction (vertical or oblique) as well as the implant insertion angle (axial or tilted). Conclusions: Tilted implants may have a lower maximum extent of micromotion than axial implants under mesiodistal oblique loading. The maximum micromotion values were strongly influenced by the loading direction. The maximum micromotion values did not reflect the abutment displacement values.

Statistical Modeling of the Pretilt Angle Control in Nematic Liquid Crystal using In-situ Photoalignment Method on Plastic Substrate

  • Kang, Hee-Jin;Lee, Jung-Hwan;Yun, Il-Gu;Seo, Dae-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권3호
    • /
    • pp.145-148
    • /
    • 2006
  • In this study, the response surface modeling of the pretilt angle control using in-situ photoalignment method with oblique UV exposure .on plastic substrate is investigated. The pretilt angle is the main factor to determine the alignment of the liquid crystal display. The response surface model is used to analyze the variation of the pretilt angle on the various process conditions. Heating temperature and UV exposure time are considered as input factors. The liquid crystal (LC) pretilt angle increased with increasing heating temperature and UV exposure time. The analysis of variance is used to analyze the statistical significance and the effect plots are also investigated to examine the relationship between the process parameters and the response.

경추 추간공 관찰을 위한 촬영법의 고찰 (The Comparison of $45^{\circ}$ and $55^{\circ}$ Anteroposterior Oblique View for Observating the Intervertebral Foramen)

  • 전주섭;은성종;김혜란;안승현;최남길;김영근
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제28권2호
    • /
    • pp.91-95
    • /
    • 2005
  • I. 목 적 : 경추의 퇴행성 질환이나 분리증을 진단하는데 필수적인 전 후 사방향 촬영은 $45^{\circ}$사방향 (하 상방향 tube angle $15^{\circ}$)으로 촬영하여 경추 추간공과 주변 구조물을 살피는 것으로 알려져 있으나 아직까지 우리나라 성인에 대한 연구결과는 거의 없는 실정이다. 본 연구는 우리나라 성인에 적합한 전 후 사방향 촬영 각도를 알아보는데 목적이 있다. II. 대상 및 실험방법 : 1. 연구대상인 성인의 경추 신경공과 정중 시상면이 이루는 평균 각을 알아보기 위해 C-spine MRI를 촬영한 환자 200명(남 100명, 평균 40.3세, 여자 100명 47.6세)을 대상으로 축방향 T2 강조영상에서 C2-C3부터 C7-T1까지의 평균 각을 구하였다. 2. 경추에 이상이 없는 남자 10명(평균 36.2세)을 대상으로 전 후 사방향 촬영시 경추 신경공과 정중 시상면이 이루는 각도에서 실제로 추간공이 가장 크게 관찰되는지를 알아보기 위하여 나선식CT(QXi, GE medical) 촬영을시행하여, 축방향 영상에서 추간공이 이루는 각과 3D Raysum기법에서의 추간공의 최대횡경을 이루는 각도를 비교하였다. 또한 경추 전후 사방향 $45^{\circ}$, $50^{\circ}$, $55^{\circ}$(하 상방향 tube angle $15^{\circ}$)로 촬영한 일반촬영 영상을 PACS로 전송하여 최대횡경을 측정하고, 그 차이를 비교하였다. III. 결 과 : 연구대상인 성인추간공의 평균 각도를 MR영상에서 측정한 결과 C2-C3, C3-C4, C4-C5, C5-C6, C6-C7, C7-T1에서의 각은 $47.4^{\circ}{\pm}3.3$, $50.5^{\circ}{\pm}2.3$, $52.7^{\circ}{\pm}4.2$, $53.2^{\circ}{\pm}1.9$, $53.2^{\circ}{\pm}2.3$, $55.2^{\circ}{\pm}2.3$로 나타나 하부 경추로 갈수록 신경공과 정중 시상면이 이루는 각이 커짐을 알 수 있었다. 10명을 대상으로 CT촬영하여 Raysum 영상에서 추간공의 최대 횡경을 보이는 각도와 2D 축방향 영상에서 측정한 추간 공의 각도의 비교에서는 유의한 차이가 없었다(P>0.01). 전 후 사방향 $45^{\circ}$, $50^{\circ}$, 그리고 $55^{\circ}$로 촬영한 일반촬영에서의추간공의최대횡경을측정한결과 C2-C3, C3-C4, C4-C5까지는 각도가 $5^{\circ}$씩 커질수록 횡경이 감소($0.11\;mm{\sim}0.21\;mm$)한 반면 C5-C6, C6-C7, C7-T1에서는 횡경이 증가($0.32\;mm{\sim}0.91\;mm$)함을 알 수 있었으며, 그 차이를 분산분석(ANOVA)을 통해 비교한 결과 하부경추로 갈수록 유의한 차이가 있는 것으로 나타났다(P<0.001). IV. 결 론 : 우리나라 성인에 있어서 추간공을 관찰하기 위한 전 후 사방향촬영각도는 상부 경추의 경우 전 후사방향 $50^{\circ}$에서, 하부 경추의 경우 $55^{\circ}$에서 추간공을 가장 크게 관찰할 수 있었다. 따라서 향후 경추의 퇴행성 질환을 진단하는데 본 연구의 촬영법이 유용할 것으로 사료된다.

  • PDF

Monocortical Osteosynthesis 이론에 따른 하악골 우각부 골절 수술시 Titanium miniplate와 Biodegradable miniplate의 임상적, 방사선학적 비교 연구 (CLINICAL AND RADIOLOGICAL COMPARISON BETWEEN TITANIUM AND BIODEGRADABLE MINIPLATE MONOCORTICAL OSTEOSYNTHESIS IN MANDIBULAR ANGLE FRACTURES)

  • 최은주;남웅;정영수;김기호;김형준
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제32권3호
    • /
    • pp.222-225
    • /
    • 2006
  • The treatment objective of mandibular fracture is a return to normal function. According to Champy, a rigid fixation of mandibular angle fracture is performed by using 4 or 6 holes titanium miniplates on the external oblique ridge of mandible. However, the limitations of metal plate such as hypersensitivity, interference with the cranio-facial growth of growing child, secondary bone resorption around the plate, foreign body reaction, declination of primary callus formation, and bone atrophy due to the lack of normal stress reaction of the bone have been reported. Recently, biodegradable miniplate has been introduced and used as an alternative to the metal plate despite its lower strength than that of the titanium plate and the side effect caused by the resorption in the body. In this study, 61 patients diagnosed as mandibular angle fracture and treated from Jan. 1998 to Dec. 2004 in our department have been reviewed. Metal plate fixation was used in 50 patients and biodegradable plate fixation in 11 patients on the external oblique ridge around the fractured mandibular angle according to the principle of monocortical osteosynthesis by Champy. We compared the incidence of side effects and the degree of bony union at the mandibular inferior border in two different fixation methods. In conclusion, we have found that one miniplate regardless of matter could provide enough strength to grasp bony fragments of the tension site and compress the inferior border of mandible without any complications.

Viewing Angle Characteristics of the Ultra-FFS TFT-LCD

  • Kim, H.Y.;Noh, J.D.;Park, C.H.;Koh, J.W.;Lee, W.G.;Park, H.S.;Lee, S.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.459-462
    • /
    • 2002
  • We report viewing angle characteristics of the Ultra-FFS TFT-LCD. The FFS mode is known to exhibit both a wide viewing angle and high transmittance, owing to the approximated in-plane rotation of the LC director. Nevertheless, in the bright state, the device shows bluish and yellowish color parallel and perpendicular to the LC director at off-normal directions since the LC director rotates onl.v in one direction, and in addition, the grey scale inversion exists in large oblique viewing angle. However, the Ultra-FFS shows no grey scale inversion and no color shift in wide viewing angle range.

  • PDF

DEPENDENCE OF STRUCTURAL AND MAGNETIC PROPERTIES ON DEPOSITTION ANGLE IN EVAPORATED Co/Pt MULTILAYER THIN FILMS

  • Moon, Ki-Seok;Shin, Sung-Chul
    • 한국자기학회지
    • /
    • 제5권5호
    • /
    • pp.465-469
    • /
    • 1995
  • We have investigated the effects of deposition angle on structural and magnetic properties of e-beam evaporated ${(4-{\AA}\;Co/9.2-{\AA}\;Pt)}_{23}$ multilayer thin films prepared on tilted substrates. It was found that the [111] crystallographic orientations of the multilayer thin films were not aligned with colummar growth orientations and they were remained to be normal to the substrate planes even though the deposition angle was severely oblique up to $60^{\circ}$. The analysis of the torque curve reveal that the intrinsic anisotropy energy was monotonically decreased with the deposition angle but the easy axis orientation parallel to the substrate normal was not much influenced by deposition angle.

  • PDF

High-Contrast Projection Screen

  • Kuo, Huei Pei
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1430-1432
    • /
    • 2008
  • We have developed a high-contrast ambient-light rejection projection screen with surface micro-structures for front and rear projection displays with an oblique-angle projector. We have fabricated prototype screens that show a better than $10{\times}$ improvement in contrast compared to a matte-white screen under various ambient lighting conditions and screen luminance.

  • PDF