• Title/Summary/Keyword: Oblique

Search Result 1,721, Processing Time 0.032 seconds

A COMPARATIVE STUDY ON RELIABILITY OF THE ROOT PARALLELISM OF THE POSTERIOR TEETH PROJECTED ON THE ORTHOPANTOMOGRAM WITH THE $45^{\circ}$ OBLIQUE CEPHALOGRAM (Orthopantomogram과 $45^{\circ}$ 측모두부 방사선 사진과의 구치부 치근평행도의 신뢰도에 관한 비교연구)

  • Min, Young-Gyu;Ryu, Young-Kyu
    • The korean journal of orthodontics
    • /
    • v.23 no.3 s.42
    • /
    • pp.359-374
    • /
    • 1993
  • At present, many orthodontists regard the root parallelism of the posterior teeth important not only in diagnosis and treatment planning but also for predicting posttreatment stability. To evaluate it, they usually refer to the orthopantomogram. At this study, 97 samples were collected from students of Yonsei University, who have well-proportioned face, Angle's class I canine & molar relationships and no crown axis deviation of the posterior teeth including canines. Reliability of the root parallelism observed from orthopantomogram was evaluated by comparison with $45^{\circ}$ oblique cephalogram. The results were as follows : 1. In comparing the differences between anglular measurements in $45^{\circ}$ oblique cephalogram & orthopantomogram with $5^{\circ}$, those to mandibular plane were significantly less than to occlusal plane in number of items which showed less differences than $5^{\circ}$. 2. Compared the root parallelisms in the orthopantomogram with those in $45^{\circ}$ oblique cephalogram with $1\%$ significance level, parallelism between upper canine & 1st premolar, lower canine & 1st premolar, lower 1st premolar & 2nd premolar, and lower right 2nd molar & 3rd molar showed statistically significant differences. 3. When the significance between the differences of the root parallelism between above two kinds of film and $5^{\circ}$ was verified by two sided paired t-test, more or less large difference was shown between lower right 2nd molar & 3rd molar, a little larger than $5^{\circ}$ between lower canine & 1st premolar, smaller at the rest of them. 4. In $45^{\circ}$ oblique cephalogram, lower canine & 1st premolar showed convergent root arrangements each other, while in orthopantomogram they were divergent each other. All the others except them showed convergency on the upper, divergency on the lower in both films.

  • PDF

Correction of Distal Interphalangeal Joint Extension Lag Using Spiral Oblique Retinacular Ligament Reconstruction (나선빗인대 재건을 이용한 원위지관절 신전장애의 교정)

  • Moon, Kyung Hwan;Kim, Jin Soo;Lee, Dong Chul;Ki, Sae Hwi;Roh, Si Young;Yang, Jae Won
    • Archives of Plastic Surgery
    • /
    • v.33 no.4
    • /
    • pp.480-484
    • /
    • 2006
  • Purpose: A lot of surgical techniques were tried to correct extension lag of distal interphalangeal joint. Spiral oblique retinacular ligament reconstruction is the one of correction techniques. Methods: From January 2004 to January 2005, a total of 13 extension lag of distal interphalangeal joint corrections were performed using spiral oblique retinacular ligament reconstruction for 11 patients. After dorsal incision exposing from base of distal phalanx to proximal phalanx, the new ligament(half of lateral band or graft tendon) lies distally at the dorsum of the distal phalanx and passes volarly and proximally along the side of the middle phalanx and anterior and obliquely across the front of the proximal interphalangeal joint to the opposite side of the digit at the proximal phalanx. Results: 5 of 6 mallet finger deformities and 7 swan neck deformities were corrected, which were both extension lag of distal interphalangeal joint and hyperextension of proximal interphalangeal joint. Conclusion: As a result, spiral oblique retinacular ligament reconstruction is an effective and recommendable method for correction of mallet finger deformity and swan neck deformity.

Platform Calibration of an Aerial Multi-View Camera System (항공용 다각사진 카메라 시스템의 플랫폼 캘리브레이션)

  • Lee, Chang-No;Kim, Chang-Jae;Seo, Sang-Il
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.28 no.3
    • /
    • pp.369-375
    • /
    • 2010
  • Since multi-view images can be utilized for 3D visualization and surveying as well, a system calibration is an essential procedure. The cameras in the system are mounted to the holder and their locations and attitudes are relatively fixed. Therefore, the locations and the attitudes of the perspective centers of the four oblique looking cameras can be calculated using the location and attitude of the nadir looking camera and the boresight values between the cameras. In this regard, this research is focusing on the analysis of the relative location and attitude between the nadir and oblique looking cameras based on the results of the exterior orientation parameters after the aerial triangulation of the real multiview images. We acquired high standard deviations of the relative locations between the nadir and oblique cameras. Standard deviations of the relative attitudes between the cameras were low when only the exterior orientations of the oblique looking cameras were allowed to be adjusted. Moreover, low standard deviations of the relative attitudes came when we considered not all the exterior orientations of the cameras but the attitudes of them only.

Oblique Incidence Technique for Ultrasonic Nonlinear Characterization in SUS316L Alloy (SUS316L 강의 초음파 비선형 특성평가를 위한 경사입사기법)

  • Baek, Seung-Hyun;Lee, Tae-Hun;Kim, Chung-Seok;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.345-351
    • /
    • 2010
  • The oblique incidence technique for ultrasonic nonlinear characterization was studied in stainless steel 316L alloy subjected to high cycle fatigue. A dog-bone plate specimen was prepared to make different faitgue-driven deformation at each position where the stress concentration could occur in the middle of specimen. In addition to the normal transmission technique, the oblique incidence technique which is newly suggested in this study, was used to measure ultrasonic nonlinear parameter. The fatigued specimen shows higher ultrasonic nonlinear parameter than the virgin specimen for both techniques. Ultrasonic nonlinear parameter highly increases in the middle of test specimen where the stress concentration existes. Relative nonlinear parameter has strong correlation with fatigue damage. Consequently, the oblique incidence technique with longitudinal wave can be potential to characterize high cycle fatigue damage.

Finite Element Stress Analysis according to Apical-coronal Implant Position

  • Kang, Tae-Ho;Kim, Su-Gwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.1
    • /
    • pp.52-59
    • /
    • 2006
  • Purpose: The purpose of this study was to evaluate the influence of apical-coronal implant position on the stress distribution after occlusal and oblique loading. Materials and Methods: The cortical and cancellous bone was assumed to be isotropic, homogeneous, and linearly elastic. The implant was apposed to cortical bone in the crestal region and to cancellous bone for the remainder of the implant-bone interface. The cancellous core was surrounded by 2-mm-thick cortical bone. An axial load of 200 N was assumed and a 200-N oblique load was applied at a buccal inclination of 30 degrees to the center of the pontic and buccal cusps. The 3-D geometry modeled in Iron CAD was interfaced with ANSYS. Results: When only the stress in the bone was compared, the minimal principal stress at load Points A and B, with a axial load applied at 90 degrees or an oblique load applied at 30 degrees, for model 5. The von Mises stress in the screw of model 5 was minimal at Points A and B, for 90- and 30-degree loads. When the von Mises stress of the abutment screw was compared at Points A and B, and a 30-degree oblique load, the maximum principal stress was seen with model 2, while the minimum principal stress was with model 5. In the case of implant, the model that received maximum von Mises stress was model 1 with the load Point A and Point B, axial load applied in 90-degree, and oblique load applied in 30-degree. Discussion and Conclusions: These results suggests that implantation should be done at the supracrestal level only when necessary, since it results in higher stress than when implantation is done at or below the alveolar bone level. Within the limited this study, we recommend the use of supracrestal apical-coronal positioning in the case of clinical indications.

The Effect of Visual Biofeedback on EMG Activity of Trunk Muscles and Endurance Holding Time for Correct Position During Whole-Body Tilt Exercise (전신 기울기 운동 시 시각적 바이오피드백이 올바른 자세 유지 시간과 체간 근육의 근활성도에 미치는 영향)

  • Kang, Min-Hyeok;Yoon, Ji-Yeon;Yang, Jae-Lak;Jang, Jun-Hyeok;Jung, Doh-Heon;Oh, Jae-Seop
    • Physical Therapy Korea
    • /
    • v.18 no.1
    • /
    • pp.9-17
    • /
    • 2011
  • The purpose of this study was to assess visual biofeedback's influence on trunk muscles' (EMG) activity and endurance holding time for correct position during whole-body tilt exercise. For the study, we recruited 14 volunteers who showed no symptom of lumbar disease during medical tests. We measured the EMG activity of their rectus abdominis, external abdominal oblique, internal abdominal oblique and erector spinae muscles, and their endurance holding time for correct position during $40^{\circ}$ anterior and posterior whole-body tilt under two conditions: whole-body tilt with and without visual biofeedback. Resistance with gravitational force on the trunk during whole-body tilt was applied by using a device that had a monitor on which the subjects could check their alignment and that sounded an alarm if a subject's alignment collapsed. The study showed an increase in the EMG activity of external abdominal oblique, internal abdominal oblique/rectus abdominis ratio and endurance holding time for correct position during both $40^{\circ}$ anterior and posterior whole-body tilt with visual biofeedback compared with without visual biofeedback (p<.05). We suggest that the whole-body tilt exercise with visual biofeedback could be a beneficial strategy for selectively strengthening the internal abdominal oblique muscle and minimizing the rectus abdominis muscle's activity while maintaining correct alignment during whole-body tilt exercise.

3D FE Model with FEA Factors and Plastic Shots for Residual Stress Under Oblique Shot Peening (경사충돌 피닝잔류응력에 미치는 해석인자의 영향 및 소성숏이 포함된 3차원 유한요소모델)

  • Lee, Bae-Hwa;Kim, Tae-Hyung;Lee, Hyung-Yil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.3
    • /
    • pp.323-331
    • /
    • 2010
  • In this study, we propose a 3D finite element (FE) model for the residual stress under oblique shot peening. Using the FE model for an oblique impact, we examine the effects of factors on the residual stress such as the Rayleigh damping in the material, dynamic friction, and the rate dependency of the material and systematically integrate the effects. The plastic deformation of the shot is also emphasized. Then, the FE model is used to study oblique multi-impacts. The results obtained using the FE model are compared with experimental x-ray diffraction (XRD) results; in contrast to the rigid and elastic shots, plastic shots are found to produce residual stresses similar to that shown in the XRD results. Thus, the 3D FE models with integrated factors and plastically deformable shots are validated. The proposed model will serve as a basis for the 3D FE model for multi-impacts with different impact angles to simulate the actual phenomenon of shot peening.

Evaluating Reliability of Rooftop Thermal Infrared Image Acquired at Oblique Vantage Point of Super High-rise Building (초고층건물의 사각조망에서 촬영된 지붕표면 열화상의 신뢰도 평가)

  • Ryu, Taek-Hyoung;Um, Jung-Sup
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.51-59
    • /
    • 2013
  • It is usual to evaluate the performance of the cool roof by measuring in-site rooftop temperature using thermal infra-red camera. The principal advantage of rooftop thermal infrared image acquired in oblique vantage point of super high-rise building as a remote sensor is to provide, in a cost-effective manner, area-wide information required for a scattered rooftop target with different colors, utilizing wide view angle and multi-temporal data coverage. This research idea was formulated by incorporating the concept of traditional remote sensing into rooftop temperature monitoring. Correlations between infrared image of super high-rise building and in-situ data were investigated to compare rooftop surface temperature for a total of four different rooftop locations. The results of the correlations analyses indicate that the rooftop surface temperature by the infrared images of super high-rise building alone could be explained yielding $R^2$ values of 0.951. The visible permanent record of the oblique thermal infra-red image was quite useful in better understanding the nature and extent of rooftop color that occurs in sampling points. This thermal infrared image acquired in oblique vantage point of super high-rise made it possible to identify area wide patterns of rooftop temperature change subject to many different colors, which cannot be acquired by traditional in-site field sampling. The infrared image of super high-rise building breaks down the usual concept of field sampling established as a conventional cool roof performance evaluation technique.

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF INTERNALLY CONNECTED IMPLANT SYSTEMS (내부연결방식 임플랜트 시스템의 삼차원 유한요소법적 연구)

  • Kim Yu-Lee;Cho Hye-Won;Lee Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.85-102
    • /
    • 2006
  • Statement of problem: Currently, there are some 20 different geometric variations in implant/abutment interface available. The geometry is important because it is one of the primary determinants of joint strength, joint stability, locational and rotational stability. Purpose: As the effects of the various implant-abutment connections and the prosthesis height variation on stress distribution are not yet examined this study is to focus on the different types of implant-abutment connection and the prosthesis height using three dimensional finite element analysis. Material and method. The models were constructed with ITI, 3i TG, Bicon, Frialit-2 fixtures and solid abutment, TG post, Bicon post, EstheticBase abutment respectively. And the super structures were constructed as mandibular second premolar shapes with 8.5 mm, 11 mm, 13.5 mm of crown height. In each model, 244 N of vertical load and 244 N of $30^{\circ}$ oblique load were placed on the central pit of an occlusal surface. von Mises stresses were recorded and compared in the crowns, abutments, fixtures. Results: 1. Under the oblique loading, von Mises stresses were larger in the crown, abutment, fixture compared to the vertical loading condition. 2. The stresses were increased proportionally to the crown height under oblique loading but showed little differences with three different crown heights under vertical loading. 3. In the crown, the highest stress areas were loading points under vertical loading, and the finish lines under oblique loading. 4. Under the oblique loading, the higher stresses were located in the fixture/abutment interface of the Bicon and Frialit-2 systems compared to the ITI and TG systems. Conclusions: The stress distribution patterns of each implant-abutment system had difference among them and adequate crown height/implant ratio was important to reduce the stresses around the implants.

Characteristics of Al Films Prepared by Oblique Angle Deposition (빗각 증착으로 제조한 Al 박막의 특성)

  • Park, Hye-Sun;Yang, Ji-Hoon;Jung, Jae-Hun;Song, Min-A;Jeong, Jae-In
    • Journal of the Korean institute of surface engineering
    • /
    • v.45 no.3
    • /
    • pp.111-116
    • /
    • 2012
  • Oblique angle deposition (OAD) is a physical vapor deposition method which utilizes non-normal angles between the substrate and the vaporizing source. It has been known that tilting the substrate changes the properties of the film deposited on it, which was thought to be a result of morphological change of the film. In this study, OAD has been applied to prepare single and multilayer Al films by magnetron sputtering. The magnetron sputtering source of 4 inch diameter was used to deposit the films. Al films have been deposited on Si wafers and cold-rolled steel sheets. The multilayer films were prepared by changing the tilting angle upside down at each layer interval, which means that when the first layer was deposited at an angle of $+45^{\circ}$, the second layer was deposited at an angle of $-45^{\circ}$, and vice versa. The microstructure, surface roughness and reflectance of the films were investigated using a scanning electron microscope, a surface profiler and a spectrophotometer, respectively. The corrosion resistance was measured and compared using the salt spray test. The single layer film prepared at an oblique angle of $60^{\circ}$ prepared at other angles. However, for the multilayer films, the film prepared at an oblique angle of $45^{\circ}$ showed the most compact and featureless structure. The multilayer films were found to exhibit higher corrosion resistance than the single layer films.