• Title/Summary/Keyword: Objective quantification

Search Result 212, Processing Time 0.03 seconds

The Development of pulse Diagnostic Apparatus enable to gain multi-information and it's Clinical Significance (다정보(多情報) 획득(獲得)을 위한 맥진기 개발과 임상적 의의)

  • Park, Y.B.;Lee, H.J.;Huh, W
    • The Journal of Korean Medicine
    • /
    • v.16 no.1 s.29
    • /
    • pp.499-504
    • /
    • 1995
  • Recently, there are deep and much concerns about the objective assessment of diagnosis in Oriental Medicine. Among them, pulse diagnostics is used for the quantitative device of diagnosis. The objective research of pulse diagnosis were mainly conducted by pulse wave. So it is important to gain multi-information for the quantification of pulse diagnosis. We report the development of pulse diagnostic apparatus enable to gain the multi-information, detect the pressure pulse wave in conku(寸口) area and obtain the gradient curve and original pulse wave simultaneously, and consider the pulse wave with the traditional pulse diagnosis at the same time.

  • PDF

Evaluation of Fabric Pilling Using Hybrid Imaging Methods

  • Kim Sung-Min;Park Chang-Kyu
    • Fibers and Polymers
    • /
    • v.7 no.1
    • /
    • pp.57-61
    • /
    • 2006
  • A study has been made on the quantification and evaluation of fabric pilling using two-dimensional and three-dimensional hybrid imaging methods. Two-dimensional imaging method was good for some samples while three-dimensional measurement method for others, according to the properties of their base fabric. Various image processing techniques as well as three-dimensional data processing algorithms were applied for the extraction of pills from measured data and a series of shape parameters have been defined for the objective evaluation of fabric pilling. An evaluation criterion that is compatible with the conventional evaluation method has been proposed by applying the new evaluation method to the current photographic standards.

EVALUATION OF CAMERA PERFORMANCE USING ISO-BASED CRITERIA

  • Ko, Kyung-Woo;Park, Kee-Hyon;Ha, Yeong-Ho
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.76-79
    • /
    • 2009
  • This paper investigates the performance of a vehicular rear-view camera through quantifying the image quality based on several objective criteria from the ISO (International Organization for Standardization). In addition, various experimental environments are defined considering the conditions under which a rear-view camera may need to operate. The process for evaluating the performance of a rear-view camera is composed of five objective criteria: noise test, resolution test, OECF (opto-electronic conversion function) test, color characterization test, and pincushion and barrel distortion tests. The proposed image quality quantification method then expresses the results of each test as a single value, allowing easy evaluation. In experiments, the performance evaluation results are analyzed and compared with those for a regular digital camera.

  • PDF

APPLICATION OF INFRARED THERMOGRAPHY IN DENTISTRY (치과에서의 적외선 체열사진의 응용)

  • Lee, Hoon;Kim, Su-Gwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.4
    • /
    • pp.335-341
    • /
    • 2005
  • This study discusses the effects of infrared thermography in dentistry. Infrared thermography allows the quantification of infrared rays and provides useful data for dental care and research. It has been used for the diagnosis of temporomandibular dysfunction (TMD) and proposed as an objective measure of myofascial pain. It is closely related to temperature and produces beneficial objective data. A study of the heat emissions from facial structures has the potential to benefit dental diagnosis of TMD, postoperative inferior alveolar damage, and endodontic and conservative treatments. In this paper, we assessed infrared thermography in dentistry and consider future developments of infrared thermography.

Sclera Segmentation for the Measurement of Conjunctival Injection (결막 충혈도 측정을 위한 공막 영상 분할)

  • Bae, Jang-Pyo;Kim, Kwang-Gi;Jeong, Chang-Bu;Yang, Hee-Kyung;Hwang, Jeong-Min
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.8
    • /
    • pp.1142-1153
    • /
    • 2010
  • Conjunctival injection is the initial symptom of various eye diseases such as conjunctivitis, keratitis, or uveitis. The quantification of conjunctival injection may help the diagnosis and follow-up evaluation of various eye diseases. The size of the sclera is an important factor for the quantification of conjunctival injection. However, previous manual segmentation is time-consuming.Automatic segmentation is needed to extract the objective region of interest. This paper proposed a method based on the level set algorithm to segment the sclera from an anterior eye image. The initial model of the level set algorithm is calculated using the Lab color space, k-means algorithm and the geometric information. The level set algorithm was applied to the images in which the valley between the eyeball and skin was enhanced using the hessian analysis. This algorithm was tested with 52 images of the anterior eye segment. Results showed that the proposed method performs better than those with the level set algorithm using an arbitrary circle, or the region growing algorithm with color information. The proposed method for the segmentation of sclera may become an important component for the objective measurement of the conjunctival injection.

A Digital Device-Based Method for Quantifying Motor Impairment in Movement Disorders (디지털 디바이스를 이용한 이상운동증에서의 운동손상 정량화 방법)

  • Bae, Suhan;Yun, Daeun;Ha, Jaekyung;Gwon, Daeun;Kim, Young Goo;Ahn, Minkyu
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.247-255
    • /
    • 2020
  • Accurate diagnosis of movement disorders is important for providing right patient care at right time. In general, assessment of motor impairment relies on clinical ratings conducted by experienced clinicians. However, this may introduce subjective opinions into scoring the severity of motor impairment. Digital devices such as table PC and smart band with accelerometer can be used for more accurate and objective assessment and possibly helpful for clinicians to make right decision of patient's states. In this study, we introduce quantification algorithms of motor impairment which uses the digital data acquired during four clinical motor tests (Line drawing, Spiral drawing, Nose to finger and Hand flip tests). The step by step procedure of quantifying metrics (Tremor Frequency, Tremor Magnitude, Error Distance, Time, Velocity, Count and Period) are provided with flowchart. The effectiveness of the proposed algorithm is presented with the result from simulated data (normal, normal with tremor and slowness, poor with tremor, poor with tremor and slowness).

Quantification of The Conflict in Film Narrative: Focusing on Comparison of Characters' Face Area (영화 서사 속 갈등의 정량화 연구: 등장인물의 얼굴면적 비교를 중심으로)

  • Kang, Soohwan;Park, Seung-Bo;Kim, Yeong Hun;You, Eun Soon
    • Journal of Broadcast Engineering
    • /
    • v.24 no.1
    • /
    • pp.153-163
    • /
    • 2019
  • This paper analyzes the film in a quantitative method to understand the principle to assign film's narrative as an art form. To do this, we tried to quantify 'conflict', which is a key factor of narrative, according to measuring the information represented in images. And thus, we measured the face areas of Protagonist and Antagonist, and then analyzed the relationship between area and conflict. The reason why the face area is used as the measurement target is because it is an index showing the way in which the director represents the conflict in the film. The quantification of conflict in films can be applied to indexing the narrative structure or specific conflict sections based on objective figures. In addition, it is possible to visualize narrative through conflict graphs, and it is meaningful that the computational criticism can apply into narrative study by quantification of conflict.

An Efficient Method for Aneurysm Volume Quantification Applicable in Any Shape and Modalities

  • Chung, Jaewoo;Ko, Jung Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.4
    • /
    • pp.514-523
    • /
    • 2021
  • Objective : Aneurysm volume quantification (AVQ) using the equation of ellipsoid volume is widely used although it is inaccurate. Furthermore, AVQ with 3-dimensional (3D) rendered data has limitations in general use. A novel universal method for AVQ is introduced for any diagnostic modality and application to any shape of aneurysms. Methods : Relevant AVQ studies published from January 1997 to June 2019 were identified to determine common methods of AVQ. The basic idea is to eliminate the normal artery volume from 3D model with the aneurysm. After Digital Imaging and Communications in Medicine (DICOM) data is converted and exported to stereolithography (STL) file format, the 3D STL model is modified to remove the aneurysm and the volume difference between the 3D model with/without the aneurysm is defined as the aneurysm volume. Fifty randomly selected aneurysms from DICOM database were used to validate the different AVQ methods. Results : We reviewed and categorized AVQ methods in 121 studies. Approximately 60% used the ellipsoid method, while 24% used the 3D model. For 50 randomly selected aneurysms, volumes were measured using 3D Slicer, RadiAnt, and ellipsoid method. Using 3D Slicer as the reference, the ratios of mean difference to mean volume obtained by RadiAnt and ellipsoid method were -1.21±7.46% and 4.04±30.54%, respectively. The deviations between RadiAnt and 3D Slicer were small despite of aneurysm shapes, but those of ellipsoid method and 3D Slicer were large. Conclusion : In spite of inaccuracy, ellipsoid method is still mostly used. We propose a novel universal method for AVQ that is valid, low cost, and easy to use.

Development and Application of Horticultural Kit for Children's Horticulture Education

  • Kwack, Hye Ran
    • Journal of People, Plants, and Environment
    • /
    • v.24 no.6
    • /
    • pp.595-608
    • /
    • 2021
  • Background and objective: For effective horticultural education, it is required to develop kits for practice. In this study, we developed a horticultural kit for germination that introduces storytelling, characterization, and assembly, and investigated the educational effects of using it to study its educational differentiation and usefulness. Methods: First, we developed a seed germination kit for learning. It consists of three components: the kit main frame for hydroponics, the activity sheet for storytelling, and the instruction manual. It is made into an acrylic assembly in consideration of the ease of delivery for contactless learning. Second, we developed two programs, each using a germination kit for horticultural education (experimental group) and a general germination kit program (control group). At this time, the class consists of pre-questionnaire, the 1st and 2nd classes, observation log writing (total six times for two weeks), the 3rd class, and post-questionnaire. The experimental group and control group were separately executed. Third, the application results were compared and analyzed before and after class. As a quantification questionnaire, the effects before and after class were compared through t-test with a questionnaire on program satisfaction and attitude change toward plants. The quantitative results were analyzed through observation activity sheets and effects before and after the class were analyzed through t-test with quantification and language coding. Results: The effect of horticulture education using the developed kit was estimated by a quantification questionnaire. Both the program satisfaction and the change in attitude toward plants showed high in the experimental group, and this difference was statistically significant (p < .05). As a result of analyzing the observation paper with a qualitative questionnaire, various cognitive and affective expressions appeared in the experimental group as well as the contents of the observation paper. The number of syllables and various qualitative expressions appeared, and these differences were also statistically significant (p < .05). Conclusion: Compared to general germination activities, it was found that the germination activities using storytelling-based horticultural kits would be effective for contactless classes in the post-COVID-19 era and in increasing the educational effect of horticultural activities.

Quantification of Pancreas Surface Lobularity on CT: A Feasibility Study in the Normal Pancreas

  • Riccardo Sartoris;Alberto Calandra;Kyung Jin Lee;Tobias Gauss;Valerie Vilgrain;Maxime Ronot
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1300-1309
    • /
    • 2021
  • Objective: To assess the feasibility and reproducibility of pancreatic surface lobularity (PSL) quantification derived from abdominal computed tomography (CT) in a population of patients free from pancreatic disease. Materials and Methods: This retrospective study included 265 patients free from pancreatic disease who underwent contrast-enhanced abdominal CT between 2017 and 2019. A maximum of 11 individual PSL measurements were performed by two abdominal radiologists (head [5 measurements], body, and tail [3 measurements each]) using dedicated software. The influence of age, body mass index (BMI), and sex on PSL was assessed using the Pearson correlation and repeated measurements. Inter-reader agreement was assessed using the intraclass correlation coefficient (ICC) and Bland Altman (BA) plots. Results: CT images of 15 (6%) patients could not be analyzed. A total of 2750 measurements were performed in the remaining 250 patients (143 male [57%], mean age 45 years [range, 18-91]), and 2237 (81%) values were obtained in the head 951/1250 (76%), body 609/750 (81%), and tail 677/750 (90%). The mean ± standard deviation PSL was 6.53 ± 1.37. The mean PSL was significantly higher in male than in female (6.89 ± 1.30 vs. 6.06 ± 1.31, respectively, p < 0.001). PSL gradually increased with age (r = 0.32, p < 0.001) and BMI (r = 0.32, p < 0.001). Inter-reader agreement was excellent (ICC 0.82 [95% confidence interval 0.72-0.85], with a BA bias of 0.30 and 95% limits of agreement of -1.29 and 1.89). Conclusion: CT-based PSL quantification is feasible with a high success rate and inter-reader agreement in subjects free from pancreatic disease. Significant variations were observed according to sex, age, and BMI. This study provides a reference for future studies.