• Title/Summary/Keyword: Objective distance

Search Result 1,055, Processing Time 0.023 seconds

Sphenoid bone changes in rapid maxillary expansion assessed with cone-beam computed tomography

  • Stepanko, Lucas S.;Lagravere, Manuel O.
    • The korean journal of orthodontics
    • /
    • v.46 no.5
    • /
    • pp.269-279
    • /
    • 2016
  • Objective: Rapid maxillary expansion (RME) is used to expand the maxilla and increase arch perimeter; yet, there are few reports on its effects on the sphenoid bone. With cone-beam computed topography (CBCT), it is possible to visualize sphenoid bone changes. The purpose of this study was to investigate sphenoid bone changes observed in conjunction with RME treatments, using CBCT. Methods: Sixty patients (34 women and 26 men, aged 11-17 years) underwent RME as part of their orthodontic treatment. Patients were randomly assigned to one of three groups: a tooth-anchored group, a bone-anchored group, or a control group. Initial CBCT scans were performed preceding the RME treatment ($T_1$) and again directly after the completion of expansion ($T_2$). Statistical analysis included ANOVA, descriptive statistics, and the intraclass correlation coefficient (ICC). Results: The reliability of the landmark location was at least 0.783, and the largest ICC mean measurement error was 2.32 mm. With regard to distances, the largest change was 0.78 mm, which was not statistically significant (p > 0.05). Statistical significance was established in patient groups of the same sex and treatment type for the following distance measurements: right anterior lateral pterygoid plate to the right edge of the hypophyseal fossa ($d_2$), anterior distance between the medial pterygoid plates ($d_4$), and anterior distance between the left medial and lateral plates ($d_8$). Conclusions: In this study, there were no clinically significant changes in the sphenoid bone due to RME treatments regardless of sex or treatment type.

The Effects Where the Stroke Shoes Which Use Functional Electric Stimulation Goes Mad to Walking of the Hemiplegia (기능적 전기자극 치료기를 이용한 중풍구두가 편마비 환자의 보행에 미치는 영향)

  • Kim, Jeong-Seon;Park, Ji-Whan
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.13 no.1
    • /
    • pp.36-43
    • /
    • 2007
  • Purpose: An objective analysis and observations were to be done on hemiplegia patients that are wearing a walking support device, Stroke shoes. Their improvements in walking pace, the reduction of distance between the two knee joint, the increase of curve angle of the knee joint and their steps and the reduction of ankle joint upon swing phase were analyzed using a 20 walking analyzer. Methods: An examination was carried out to see the patients' communication skill and independent walking and then let them walk with the Stroke shoes on to get results before and after wearing it. Simi Reality Motion Systems GmbH (Germany, 2007) was used to analyze the results regarding knee joint and ankle joint angle changes of sagitta plane and coronal plane, stepping distances, distances between the knees and walking pace. Results: 1. The articulation angle of ankle joint during swing phase decreased and knee joint has shown a statistically significant increase in such value(p<0.05). 2. Only knee joint showed a significant increase in articulation angle during heel strike(p<0.05). 3. Knee joint showed a significant increase in articulation angle during toe off(p<0.05). 4. The distance between the two knees as well as their foot steps significantly decreased compared with when Stroke shoes were not worn(p<0.05). 5. Stroke shoes with FES have shown positive effects on the patients in improving their walking styles overall. (p<0.05). Conclusion: There was an improvement in rotation walking pattern by a reduction in the distance between the knees after wearing Stroke shoes with FES. Plantar flexion reduced that occurred in ankle joint during walking and flexion angle increased in knee joint, both of which improved foot drop which was a major problem in hemiplegia patients. Also it is believed that the device will have some positive influences on knee joint stiffening paralysis to aid in improving inefficient walking phases.

  • PDF

A Study on the Characteristics of Visual Aspects in MAISAN Provincial Park (마이산도립공원의 전망경관 특성에 관한 연구)

  • Kim, Sei-Chon;Rho, Jae-Hyun;Park, Jae-Chul;Huh, Joon
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.24 no.2
    • /
    • pp.74-85
    • /
    • 1996
  • The objective of this study is to investigate the influence of viewing aspects based on formal aesthetics and psychophysica approaches of the MAISAN provincial park for landscape management. Two methods are applied in this study. First, according to the field study with map the quantitative analyses of the viewshed area, visual section and scenery types were achieved, herein the visual landscape characteristics is found. Second, based upon visual preference evaluation of the relationships between the viewing aspects and visual preference scores to landscape slides were measured by questionnaires. The main conclusions obtained by the research are as follows. Visual area of MAISAN has a quite wide viewshed though itself is surrounded. The preference for the visual terminal were change by its characteristics to the visual corridors, view points, viewing types and viewing distance. Especially, the regression analysis between visual preference and viewing distance indicated Y=-3.20X\sup 2\+18.64X+20.64. In this case, viewing distance 794m from O\sub p\ is more important point for visual experience. The viewing types B·C and famous view A obtained a high visual preference score. A visual terminus are viewed along an entire RouteA, so revealed by its evolving spatial containment as to exact the full potential of its changing perspectives. Also we conducted the degree of visual influence by the shade in visual area at MAISAN and clarified viewing vantage Route and point in LSH being necessary for landscape preservation.

  • PDF

Comparison of Three-dimensional Kinematic Changes of the Lower Extremity between the Two Different Braking Distances of Snowplow in Alpine Skiing

  • Kim, Joo-Nyeon;Kim, Jin-Hae;Ryu, Jiseon;Yoon, Sukhoon;Park, Sang-Kyoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.4
    • /
    • pp.361-367
    • /
    • 2016
  • Objective: The aim of this study was to compare three-dimensional kinematic changes of the lower extremity between the two different braking distances during snowplow in alpine skiing. Method: Six alpine ski instructors (age: $25.3{\pm}1.5yr$, height: $169.3{\pm}2.9cm$, weight: $66.2{\pm}5.9kg$, career: $4.2{\pm}2.9yr$) participated in this study. Each skier was asked to perform snowplow on the two different braking distances (2 and 4 m). Results: Snowplow and edging angles (p = .006 and p = .005), ankle adduction and inversion (p = .033 and p = .002), knee extension (p = .003), and hip abduction and internal rotation (p = .043 and p = .006) were significantly greater in the 2 m than in the 4 m braking distance. Conclusion: Based on our results, we suggest that skiers should make greater snowplow and edging angles on the shorter braking distance. In this situation, ankle joint adduction/inversion angle and hip joint internal-rotation make greater snowplow angle, and hip joint abduction make greater edging angle. In addition, greater knee joint extension angle may lead to more posteriorly positioned center of mass.

The Morphometric Analysis of the Extraforamen in the Lumbosacral Spine: Magnetic Resonance Imaging and Computed Tomography Study

  • Jang, Jee-Soo;Lee, Sang-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.5
    • /
    • pp.336-339
    • /
    • 2005
  • Objective: The goal of this study is to establish the anatomical criteria of the normal and stenotic lumbosacral extraforaminal tunnel, and also to determine the effect of the pathologic intervertebral disc on the size of extraforaminal tunnel in the lumbosacral spine. Methods: MRI and CT scans were reviewed and classified into two groups: (1) 40 patients with normal discs at L5- S1 (Group 1) and (2) 43 patients that had undergone successful decompression surgery for extraforaminal entrapment at the lumbosacral region(Group 2). In these two groups, the following parameters were compared are compared: the distance between the disc margin and the ala (lumbosacral tunnel) on the axial MRI, and the posterior disc height at L5-S1 on the mid-sagittal MRI. Results: In the group 1, the mean distance of the lumbosacral tunnel on the axial MRI was $10.1{\pm}2.2mm$. The mean posterior disc height at L5-S1 was $7.4{\pm}1.7mm$ on the mid-sagittal MRI. In the group 2, the mean distance between the disc margin and the ala (costal process) was $1.6{\pm}1.3mm$ on the axial MRI. The average posterior disc height was $4.4{\pm}1.5mm$ on the mid-sagittal MRI. The posterior disc height and the size of the lumbosacral tunnel between the two groups were statistically different on the paired t-test (p<0.0001). However, the posterior disc height was not positively correlated with the size of the extraforaminal tunnel for group 2 (p=0.909). Conclusion: The extraforaminal stenosis was correlated to pathologic disc. However, the posterior disc height was not correlated to the size of the of the extraforaminal tunnel.

The clinical usefulness of closed reduction of nasal bone using only a periosteal elevator with a rubber band

  • Park, Young Ji;Ryu, Woo Sang;Kwon, Gyu Hyeon;Lee, Kyung Suk
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.5
    • /
    • pp.284-288
    • /
    • 2019
  • Background: Closed reduction of nasal fracture with various instrument is performed to treat nasal fracture. Depending on the type of nasal fracture and the situation in which it is being operated, the surgeon will determine the surgical tool. The objective of this study was to investigate whether a periosteal elevator (PE) was a proper device to perform closed reduction for patients with simple nasal fractures. Methods: From March 2018 to December 2018, 50 cases of simple nasal bone fracture underwent closed reduction performed by a single surgeon. These patients were divided into two groups randomly: nasal bone reduction was performed using only PE (freer) and nasal bone reduction was performed using Walsham, Asch forcep, and Boies elevator (non-freer, non-PE). Results: The paranasal sinus computed tomography was performed on patients before and after operation to carry out an accurate measurement of reduction distance at the same level. According to the results, the interaction between instruments and fracture types had a significant influence on reduction distance (p = 0.021). To be specific, reduction distance was significantly (p= 0.004) increased by 2.157 mm when PE was used to treat patients with partial displacement compared to that when non-PEs were used. Conclusion: Closed reduction using PE and other elevator is generally an effective treatment for nasal fracture. In partial-displacement type of simple nasal fracture, closed reduction using PE can have considerable success in comparison with using classic instruments.

The grading of cognitive state comparisons with different distances across three conditions in stroke survivors

  • Kim, Yumi;Park, Yuhyung
    • Physical Therapy Rehabilitation Science
    • /
    • v.3 no.2
    • /
    • pp.134-141
    • /
    • 2014
  • Objective: The purpose of this study was to compare with different distance across three conditions in stroke survivors with the grading of cognitive state. Design: Cross-sectional study. Methods: Twelve stroke patients who agreed to active participation were included. Participants were allotted to normal cognitive (CN) group (n=7) and cognitive impairment (CI) group (n=5) and then walked on a self-paced walkway at three conditions on the Time Up and Go (TUG) test and the 6 minute walk test (6MWT): 1) walking with your comfortable speed, 2) walking while carrying a tray with glasses, 3) walking with a verbal cognitive task. The TUG test was repeated three successful times on each condition. For the 6MWT, participants were tested one time. Results: The CI group walked slower than the CN group at the three conditions on the TUG test. However, there was no significant difference between two groups to each condition. A significant effect of dual tasking was found only in error of verbal cognitive task condition for the TUG test (p<0.05). On the 6MWT, the participants in the CI group walked short distance rather than the CN group (p<0.05). There were significant differences between two groups not only at all conditions but also at error of verbal cognitive task condition as well (p<0.05). Conclusions: To consider the results of different distances such as the TUG test and the 6MWT, we think that exercises in long distance would be more effective to patients with CI. Those would be improved patient's endurance in cognitive problem.

Geometric Evaluation of Patient-Specific 3D Bolus from 3D Printed Mold and Casting Method for Radiation Therapy

  • An, Hyun Joon;Kim, Myeong Soo;Kim, Jiseong;Son, Jaeman;Choi, Chang Heon;Park, Jong Min;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.30 no.1
    • /
    • pp.32-38
    • /
    • 2019
  • Purpose: The objective of this study is to evaluate the geometrical accuracy of a patient-specific bolus based on a three-dimensional (3D) printed mold and casting method. Materials and Methods: Three breast cancer patients undergoing treatment for a superficial region were scanned using computed tomography (CT) and a designed bolus structure through a treatment planning system (TPS). For the fabrication of patient-specific bolus, we cast harmless certified silicone into 3D printed molds. The produced bolus was also imaged using CT under the same conditions as the patient CT to acquire its geometrical shape. We compared the shapes of the produced bolus with the planned bolus structure from the TPS by measuring the average distance between two structures after a surface registration. Results and Conclusions: The result of the average difference in distance was within 1 mm and, as the worst case, the absolute difference did not exceed ${\pm}2mm$. The result of the geometric difference in the cross-section profile of each bolus was approximately 1 mm, which is a similar property of the average difference in distance. This discrepancy was negligible in affecting the dose reduction. The proposed fabrication of patient-specific bolus is useful for radiation therapy in the treatment of superficial regions, particularly those with an irregular shape.

Genetic diversity analysis of fourteen geese breeds based on microsatellite genotyping technique

  • Moniem, Hebatallah Abdel;Zong, Yang Yao;Abdallah, Alwasella;Chen, Guo-hong
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.32 no.11
    • /
    • pp.1664-1672
    • /
    • 2019
  • Objective: This study aimed to measure genetic diversity and to determine the relationships among fourteen goose breeds. Methods: Microsatellite markers were isolated from the genomic DNA of geese based on previous literature. The DNA segments, including short tandem repeats, were tested for their diversity among fourteen populations of geese. The diversity was tested on both breeds and loci level and by mean of unweighted pair group method with arithmetic mean and structure program, phylogenetic tree and population structure were tested. Results: A total of 108 distinct alleles (1%) were observed across the fourteen breeds, with 36 out of the 108 alleles (33.2%) being unique to only one breed. Genetic parameters were measured per the 14 breeds and the 9 loci. Medium to high heterozygosity was reported with high effective numbers of alleles (Ne). Polymorphic information contents (PIC) of the screened loci was found to be highly polymorphic for eleven breeds; while 3 breeds were reported moderately polymorphic. Breeding coefficient ($F_{IS}$) ranged from -0.033 to 0.358, and the pair wise genetic differentiation ($F_{ST}$) ranged from 0.01 to 0.36 across the fourteen breeds; for the 9 loci observed and expected heterozygosity, and Ne were same as the breeds parameters, PIC of the screened loci reported 6 loci highly polymorphic and 3 loci to be medium polymorphic, and $F_{IS}$ ranged from -0.113 to 0.368. In addition, genetic distance estimate revealed a close genetic distance between Canada goose and Hortobagy goose breeds by 0.04, and the highest distance was between Taihu goose and Graylag goose (anser anser) breed by 0.54. Conclusion: Cluster analyses were made, and they revealed that goose breeds had hybridized frequently, resulting in a loss of genetic distinctiveness for some breeds.

Identification of Causes and Prevention Measures for Health Disorders Such as Erythema of Restaurant Workers in Manufacturing Company (제조사업장 식당 종사자의 홍반 등 건강장해 원인 규명 및 예방 방안)

  • Jee Yeon Jeong;Gwangyong Yi;Seung-Hyeon Park
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.3
    • /
    • pp.238-246
    • /
    • 2024
  • Objectives: A collective of workers in the company's cafeteria encountered symptoms such as stinging and watering in and around the eyes, a sensation of sand in the eyes, erythema, swelling, and peeling of the skin on the face and neck. The objective of this study is to pinpoint the causes of these symptoms and propose preventive measures. Methods: Following preliminary on-site investigations, worker interviews, and literature research, it was determined that the most probable cause of the symptoms was ultraviolet rays emitted from a UV sterilizer. Consequently, the study measured and assessed the effective amount of ultraviolet radiation emitted by the sterilizer. Results: When operating with the curtain-type door of the ultraviolet sterilizer open, it was observed to surpass the 0.1 μW/cm2 8-hour work exposure standard recommended by ACGIH TLV in most kitchen workspaces. The evaluation of the maximum allowable exposure time based on the distance from the ultraviolet sterilizer indicated only 4.2 seconds at a distance of 0.2 m with the curtain door open, and merely 1.7 minutes at a distance of 1 m. Conclusions: This study confirmed that the symptoms among restaurant workers emerged immediately after the installation of the ultraviolet sterilizer, and these symptoms were consistent with those associated with exposure to ultraviolet rays. Furthermore, the assessment revealed that the exposure level to ultraviolet rays could be exceeded established exposure standards. It was recommended that the existing ultraviolet sterilizer be replaced with one featuring a glass door, and facility improvements should be made, such as implementing an automatic mechanism to turn off the ultraviolet lamp when the door is opened.