• Title/Summary/Keyword: ORP-pH system

Search Result 38, Processing Time 0.023 seconds

Development of New Method for Antioxidant Capacity with ORP-pH System

  • Lee Se Yeong;Kim Eun Ok;Seo Hyo Jin;Kim Min Yong;Kim Jong Deog
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.6
    • /
    • pp.514-518
    • /
    • 2004
  • Many methods are used in the measurement of antioxidative capacity. These meth­ods require very complex procedures and pretreatment. Our suggestions for research will be simple and accurate methods for obtaining many kinds of samples, especially colored samples such as natural product extracts for measuring antioxidative capacities. For oxidation-reduction potential (ORP) system value, we examined the relationships between the ORP-pH system and the ORAC, FRAP methods. To evaluate ORP System value, we calculated the absolute slope/intercept from the linear regression of each standard material at different concentrations and ORP-pH system, and compared the correlations with ORAC and FRAP values.

Evaluation of the Stability of Oxidation-Reduced Potential (ORP) Using the Filter of the Alkaline Water (알칼리 환원수 필터의 산화환원전위 안정화 평가)

  • Nam, Sangyep;Kwon, Yunjung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.8
    • /
    • pp.129-135
    • /
    • 2016
  • This study is about ionic water generator filter Recently, a lot of people feel deep interest in health and drinking water. Evaluation of the stability of oxidation-reduced potential (ORP) using the filter of the alkaline water. This study utilizes the three filter of activated carbon, UF, carbon block in alkaline reduced water equipment. Passing the water to the filter is evaluated that the OPR values are stability in accordance with the change of the volume in the bucket. Alkaline reduced water equipment is a system that has the function of making the water reduction. This system is the values of the human body beneficial minerals and ORP are made in the functional water has a very low value than general water. Which has passed through the filter the water in the water negative ions and positive ions through the electrolytic. After electrolysis, the cathode side by water, including $Ca^+$, $K^+$, $Mg^+$, $Na^+$ water gets Alkaline Reduced Water containing the minerals beneficial to the human body. A positive electrode side is made of the organic materials that have an anion such as chlorine (Cl), phosphorus (P), sulfur(S). This experiment uses the Alkaline Reduced Water to adjust the magnitude of the voltage of the electrolysis in the Alkaline Reduced Water. That is 1st step(pH8) 2nd step (pH8.5) 3th step (pH9), 4th step (pH9.5) in the Alkaline Reduced Water and -1st step (pH6.0), -2nd step (pH5.0) used as the acidic oxidation water. When the water passes through the three filter in this system was evaluated whether the ORP values are changed and stabilized. When about 100 liters of water passing through the filter was confirmed that the ORP values are stability and evaluation.

Characteristics of Electrolyzed Water Manufactured from Various Electrolytic Diaphragm and Electrolyte (전기분해 격막 및 전해액에 따른 전해수의 특성 비교)

  • 정진웅;김종훈;김병삼;정승원
    • Food Science and Preservation
    • /
    • v.10 no.1
    • /
    • pp.99-105
    • /
    • 2003
  • This study was carried out to investigate the efficacy of surface sterilization and the physicochemical properties of electrolyzed water manufactured from various electrolytic diaphragm and electrolyte. Physical properties of electrolyzed water manufactured from the diaphragm system were the most effective at the following conditions; the distance between diaphragms was 1.0 mm and the supplying rate of 20% NaCl was 6 mL/min. The ORP, HClO content and pH at above conditions were 1,170 mV, 100 ppm and 2.5, respectively. And two stage electrolyzed system was more effective than one stage electrolyzed water manufactured from non-diaphragm system, with 4 mL/min supplying rate of 20% NaCl, was similar to the most effective diaphragm system. But ORP, HClO content and pH were abut 800 mV, 200 ppm and 9 level, respectively. Sealed electrolyzed water could be preserved more than one month at room temperature with ORP of 750 mV in non-diaphragm system and 1,150 mV in diaphragm system, and HClO content of 100 ppm. Twelve kinds of microorganism tested were sterilized within 30 seconds from initial total counts of 10$\^$5/∼10$\^$6/cfu/ml by electrolyzed water. Though the ORP and HCIO contents of electrolyzed water manufactured from various electrolyte were higher in order of NaCl>KCl>CaCl$_2$, there were no difference between the electyolytes in the efficacy of sterilization. Salmonella typhi and Vibrio Proteolyticus were also sterilized by electrolyzed water manufactured from elctrolytes of NaCl CaC1$_2$and KCl

A Comparison of Nutrients Removal Characteristics by the Variation of Organics in $A_{2}O$ SBR and $A_{2}O$ SBBR for the Small Sewerage System (소규모 오수처리를 위한 $A_{2}O$ SBR과 $A_{2}O$ SBBR에서 유입 유기물 농도변화에 따른 염양염류 제거 특성 비교)

  • Park, Young-Seek;Jeong, No-Sung;Kim, Dong-Seog
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.451-461
    • /
    • 2006
  • Laboratory scale experiments were conducted to study the conversion of sludge from conventional activated sludge to nitrogen-phosphorus removal sludge using two types of sequencing batch reactor (SBR) systems, a conventional SBR and sequencing batch biofilm reactor (SBBR). The nitrogen and phosphorus removal characteristics were similar between SBR and SBBR and the removal efficiencies were very low when the influent TOC concentrations were low. The nitrogen and phosphorus removal efficiencies in SBR were 96% and 77.5%, respectively, which were higher than those in SBBR (88% and 42.5%) at the high influent TOC concentration. In SBBR, the simultaneous nitrification-denitrification was occurred because of the biofilm process. The variations of pH, DO concentration and ORP were changed as the variation of influent TOC concentration both in SBR and SBBR and their periodical characteristics were cleary shown at the high influent TOC concentration. Especially, the pH, DO concentration and ORP inflections, were cleary occurred in SBR compared with SBBR.

Sterilization and ecofriendly neutralization of seawater using electrolysis (전기분해에 의한 해수살균 및 친환경 중화에 관한 연구)

  • Yang, Jeong-Hyeon;Choi, Jong-Beom;Yun, Yong-Sup
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.3
    • /
    • pp.276-280
    • /
    • 2017
  • In this study, we investigated the effect of sterilization and the neutralization of treated ballast water using seawater electrolysis. The electrolysis apparatus has a cation-selective membrane for passing the cation and a titanium electrode in each cell. We examined the sterilization effect after an incubation period of 24 hr. The oxidation reaction during electrolysis caused, the solution to become strongly acidic due to the generation of a hydroxyl group, and the oxidation reduction potentials(ORP) was increased to 800 - 1200mV. After the reduction reaction, the solution became alkaline(pH 9 - 12), and ORP was decreased to - 900 - - 750 mV. It might be possible to control the pH of ballast water through electrolysis. In addition, we demonstrated the effects of sterilization of ballast water containing generated hypochlorous acid using electrolysis under high ORP condition.

A Study on the Microorganism Disinfection and Characteristics of Discharged Water of Dielectric Barrier Discharge Plasma Systems (유전체 장벽 방전 플라즈마 방전수의 특성과 미생물 소독에 관한 연구)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.2
    • /
    • pp.159-165
    • /
    • 2012
  • Objectives: This experiment was carried out to elucidate the effect of discharged water on the disinfection of $Phytophthora$ $capsici$ and evaluate the water characteristics. Methods: The dielectric barrier discharges (DBD) plasma reactor system used in this study consisted of a plasma component [discharge, ground electrode and quartz dielectric tube], high voltage source, and air supply. The effects of water characteristics such as pH, ORP and conductivity and the disinfection effect of discharged water were investigated. Results: Experimental results showed that in the process of discharge, the pH decreased, whereas ORP and electric conductivity increased. When the discharge time was 30 min, $Phytophthora$ $capsici$ of 2.94 log was disinfected within 300 seconds. Disinfection performance of stored discharged water was maintained for three days; however the disinfection effect vanished after five days. When $Phytophthora$ $capsici$ was injected into the discharged water, the disinfection effect decreased after two days. Conclusions: It is considered that the main disinfection parameters of the discharged water were chemically active species such as $H_2O_2$ and $O_3$ and high ORP.

A Study on Autocontrolled SBR for Biological Nutrient Removal with External Carbon Sources (외부탄소원 주입시 영양염류의 생물학적 제거를 위한 자동제어 SBR 공정에 관한 연구)

  • Lee, Byung-hun;Kang, Seong-jae;Lim, Sung-il;Yoo, Pyung-jong
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.4
    • /
    • pp.371-377
    • /
    • 2002
  • The purpose of this study is to develop effective operating process in order to achieve more suitable conditions of Anoxic-Oxic-Anoxic-Stripper(AOAS) SBR through real-time control. To improve the removal efficiency, glucose, methanol and synthetic food waste acid fermentant were added as an external carbon source, In the case of glucose and synthetic food waste acid fermentant, TN, TP were removed to average 86.9%, 73.0% respectively. Methanol was removed to average 64.6%, 55.4% respectively. The synthetic food waste acid fermentant proved to be the most efficient and allowed for the substitution of an external carbon source. The removal rate of $COD_{Cr}$, was approximately 90% at all cases. The results of the study that a correlation between ORP (Oxidation-Reduction Potential), pH and DO and nitrification or denitrification when an external carbon source is added and when it isn't was showed that ${\Delta}ORP$ is suitable parameter. ORP reacted properly to denitrification (${\Delta}ORP<-10$) and nitrification (${\Delta}ORP<0$). The use of real-time control saved anywhere between 61 and 67 minutes at the anoxic(1) stage and 26 to 52 minutes at the oxic(1) stage. When the time saved from the anoxic(1) and oxic(1) was added to the anoxic(2) stage for the removal efficiency of TN and TP increased from 0.7 to 13.9% and 12 to 35 % respectively.

Energy Saving and Nitrogen Removal by DO Control and Intermittent Aeration Using Extended Aeration System (장기폭기식 마을배수처리에서 간헐폭기 및 DO제어에 의한 질소제거 및 에너지 절약(지역환경 \circled3))

  • 김형중;김선주;단헌이
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.599-604
    • /
    • 2000
  • A laboratory scale extended aeration system was installed to study the effects of DO control and intermittent aeration on energy saving and nitrogen removal. The sensors of pH, DO, ORP, MLSS, and WT were installed in the aerator to monitor them and automatically control DO concentration as 2 mg/$\ell$. In the conditions showing nitrate knee on the ORP curves, nitrogen removal rates were kept over 91%. A 72.4 % of energy saving was achieved by intermittent aeration comparing with continuous aeration.

  • PDF

A Long-term Monitoring of Water Quality at Chongok Cave (천곡동굴의 수질환경 장기 모니터링)

  • Jun, Byonghee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.9
    • /
    • pp.13-19
    • /
    • 2013
  • The Chongok karst cave which is located in Donghae-city, has high tourist and educational value due to existence of many doline(sink hole). Whereas this cave is easy to approach for the tourists, because this cave is located near the downtown, a high environmental riskiness such as sewage flowing has been also involved. In study, we observed the variation of water quality with long-term monitoring and investigated the possibility of existence of impact factor to water eco-system and determined the proper long-term monitoring factor among many monitoring criteria. The groundwater quality was maintained in the range of about $14^{\circ}C$ in temperature, over 10mg/l in dissolved oxygen and 7-8 in pH, so the impact factor in water eco-system was not observed. The guide line to make sure of tourist safety was determined to 60mm/d as daily rainfall. The conductivity was suggested to main factor for long-term monitoring main factor and pH/turbidity was suitable for the supplementary factor. For the seasonal variation monitoring, ORP was recommended.

Geo-Environmental Site Investigation for Underground Oil Storage facilities and Landfill Using the Envi-Cone Penetrometer System (환경콘 관입시스템을 이용한 유류저장소 및 폐기물매립지 지중환경특성 조사)

  • 정하익;홍승서;김영진;홍성완;곽무영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.05a
    • /
    • pp.33-36
    • /
    • 2000
  • The purpose of this study investigated underground oil storage(USTs) and Landfill using the envi-cone penetrometer system. The electrical resistivity sensor, pH sensor, ORP sensor, and thermometer are installed in envi-cone penetrometer system. This envi-cone penetrometer system provides a continuous profile of measurements, and it is rapid, repeatable, reliable and cost effective for investigation of contaminated ground.

  • PDF