• Title/Summary/Keyword: ORC System

Search Result 78, Processing Time 0.023 seconds

Operating Characteristics of a Scroll Expander Used in Organic Rankine Cycle (유기랭킨사이클 적용 스크롤 팽창기 성능 특성 연구)

  • Shin, Dong-Gil;Kim, Young-Min;Kim, Chang-Gi
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.12
    • /
    • pp.776-781
    • /
    • 2011
  • The rapid increases in global energy demand and global warming need renewable energy sources such as solar thermal energy, biomass energy and waste heat. A ORC-based micro-CHP system(< 10 kWe) is one of the effective means to use renewable energy and solve energy problems because of its compactness, flexibilities and lower cost compared to other systems. The most important core components of the ORC is the expander which has a strong effect on the cycle efficiency. In the range of power output from 1 to 10 kW, the scroll expander is a good choice due to its performance and reliability. In this study, we have carried out an experimental study on an ORC equipped with oil-free scroll expander working with refrigerant R134a. We have measured power output and thermal efficiencies of the ORC and analyzed correlation between volumetric efficiencies of the expander and thermal efficiencies of the ORC.

Feasibility of a Solar Thermal Organic Rankine Cycle Power Plant for an Apartment Complex with Aspen Plus® (ASPEN PLUS®를 이용한 태양열 유기랭킨사이클 열병합 발전시스템의 공동주택 적합도 분석)

  • Im, Seokyeon;Kim, Hyung-Geun;Yu, Sangseok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.4
    • /
    • pp.317-324
    • /
    • 2015
  • In this study, a solar thermal system is designed to provide hot water and electricity for improvement of solar thermal energy availability in an apartment complex. The electricity is generated with Organic Rankine Cycle (ORC) by the solar thermal energy. R134a, R141b and R245fa are selected for operating fluid of the solar thermal ORC system. ORC with R245fa shows the best performance based on the variation of pressure. The irreversibility of component showed that the technology advance of the evaporator ensures a performance improvement. The sensitivity study results indicate that the turbine performance is most effective way to improve the performance of ORC system. An economic analysis showed that approximately 50% more income could be achieved by a solar thermal ORC system with a hot water supply.

Optimization Study on the Performance Analysis of Organic Rankine Cycle for Characteristics of Low Temperature Heat Sources (저온열원의 특성에 따른 ORC 성능해석 최적화 연구)

  • Eom, Hong-Sun;Yoon, Cheon-Seog;Kim, Young-Min;Shin, Dong-Gil;Kim, Chang-Gi
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.1
    • /
    • pp.51-60
    • /
    • 2012
  • Optimization procedures of performance analysis for ORC(Organic Rankine Cycle) system are established to the characteristics of low temperature heat sources such as open-type and closed-type. Effective heat recovery and heat extraction related to maximum power of the cycle as well as heat quality and thermal efficiency must be considered in the case of the open-type low temperature heat source. On the other hand, in the case of the closed-type low temperature heat source, only thermal efficiency is important due to constant heat input. In this study, thermal efficiency and exergy efficiency representing a level of close to Carnot cycle are studied, as useful index for the optimization of the ORC system. To validate the results of cycle analysis, those are compared with appropriate experimental data of ORC system as a thermal efficiency point of view.

Study of Working Fluids on Thermodynamic Performance of Organic Rankine Cycle (ORC) (작동유체에 따른 유기랭킨사이클(ORC)의 열역학적 성능에 관한 연구)

  • Kim, Kyoung-Hoon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.2
    • /
    • pp.223-231
    • /
    • 2011
  • The thermal efficiency of energy-to-power conversion becomes uneconomically low when the temperature of heat source drops below $370^{\circ}C$. ORC (Organic Rankine Cycle) has attracted much attention in last few years due to its potential in reducing consumption of fossil fuels and relaxing environmental problems, and its favorable characteristics to exploit low-temperature heat sources. In this work thermodynamic performance of ORC using nine working fluids is comparatively assessed. Special attention is paid to the effect of system parameters such as turbine inlet temperature and pressure on the characteristics of the system such as volumetric flow rate and quality at turbine exit, latent heat, net work as well as thermal efficiency. Results show that in selection of working fluid it is required to consider various criteria of performance characteristics as well as the thermal efficiency. Results also show that the system efficiencies become same irrespective of kind of working fluid when the temperature of heat source decreases to low range.

Selection of Working fluid for the Organic Rankine Cycle to Utilize Low-Temperature Waste Heat (저온 폐열을 이용하기 위한 유기랭킨 사이클의 작동유체 선정에 관한 연구)

  • Cho, Soo-Yong;Cho, Chong-Hyun
    • New & Renewable Energy
    • /
    • v.10 no.4
    • /
    • pp.36-46
    • /
    • 2014
  • Low-grade heats are wasted even though an amount of their energy is huge. In the small and medium industrial complex sites, large amount of low-grade thermal energy generated during the manufacturing process is wasted if it is not used directly for building heating or air-conditioning. In order to utilize this waste thermal energy more efficiently, organic Rankine cycle (ORC) was adopted. The range of operating temperature of ORC was set to $60^{\circ}C$ from $30^{\circ}C$ applicable low-temperature waste heat. A study was conducted to select an appropriate organic working fluid based on these operating conditions. More than 60 working fluids were screened. Eleven working fluids were selected based on the requirements as working fluid for ORC such as environmentally friendly, safety, and good operation on the expander. Finally, six working fluids were selected by considering the operating temperature ranges. Then, a cycle analysis was conducted with these six working fluids. As a results, R-245fa and R-134a appeared as appropriate working fluids for ORC operating at low-temperature condition based on the system efficiency and the turbine output power.

Thermal and Flow Analysis of Organic Rankine Cycle System Pipe Line for 250 kW Grade Waste Gas Heat Recovery (250kW급 폐열회수 시스템용 유기랭킨사이클 배관 열유동해석에 관한 연구)

  • Kim, Kyoung Su;Bang, Se Kyoung;Seo, In Ho;Lee, Sang Yun;Yi, Chung Seob
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.4
    • /
    • pp.26-33
    • /
    • 2019
  • This study is a thermal and flow analysis of Organic Rankine Cycle (ORC) pipe line for 250 kW grade waste gas heat recovery. We attempted to obtain the boundary condition data through the process design of the ORC, which can produce an electric power of 250 kW through the recovery of waste heat. Then, we conducted a simulation by using STAR-CCM+ to verify the model for the pipe line stream of the 250 kW class waste heat recovery system. Based on the results of the thermal and flow analyses of each pipe line applied to the ORC system, we gained the following conclusion. The pressure was relatively increased at the pipe outside the refracted part due to the pipe shape. Moreover, the heat transfer amount of the refrigerant gas line is relatively higher than that of the liquid line.

A Study on the Refrigerant Characteristics of the Organic Rankine Cycle Power System Using the Waste Heat of the Main Propulsion Engine (선박 주 추진 엔진폐열을 이용하는 고온도차발전시스템의 냉매특성에 관한 연구)

  • Song, Young-uk;Jee, Jae-hoon;Park, Sang-kyun;Oh, Cheol
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.6
    • /
    • pp.839-845
    • /
    • 2021
  • In this study, it shows the efficiency of each refrigerant through simulation method for ORC (Organic Rankine Cycle) power generation that converts waste heat discarded by ship exhaust into electricity for the purpose of reducing CO2 emission and increasing ship waste heat recovery. by Simulation was performed with waste heat from the exhaust gas which is relatively high temperature and cooling sea water which is relatively low temperature from ships. As a result of the sea water cooling ORC power generating system, efficiency of the working fluid with R717 is highest as a 2.86 % and the next working fluid is R152a, R134a, R143a and R125a.

Effect on the Cycle by the Properties of Working Fluids Using Organic Rankine Cycle (유기랭킨사이클의 작동유체 물성치가 사이클에 미치는 영향에 관한 연구)

  • Cho, Soo-Yong;Cho, Chong-Hyun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.4
    • /
    • pp.5-12
    • /
    • 2015
  • Several working fluids for Organic Rankine Cycle(ORC) were recommended by many researchers. However, the recommended optimal working fluids were not exactly same because the operating conditions of ORC and application were different. The major parameter to select the working fluid for ORC was the temperature of available thermal energy. In this study, low-grade thermal energy was used for the heat source for ORC and the appropriate working fluids were searched among 26 candidate working fluids. The requirements to be a working fluid for ORC were reviewed and the cycle analysis for simple cycle was conducted with $75^{\circ}C$ and $35^{\circ}C$ at the turbine inlet and exit, respectively. R600, R601, toluene were best candidates if the system could work without leaking the working fluid. Next, R236ea, R245ca, R245fa were recommended because they are not inflammable working fluids as well as better efficiency.

A Study on the Thermal Flow of Waste Heat Recovery Unit (WHRU) for Ship's Organic Rankine Cycle Power Generation System using CFD Method (CFD를 활용한 선박고온도차발전용 WHRU의 열유동 해석에 관한 연구)

  • Whang, Dae-jung;Park, Sang-kyun;Jee, Jae-hoon;Bang, Eun-shin;Oh, Cheol
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.5
    • /
    • pp.647-655
    • /
    • 2021
  • The IMO (International Maritime Organization) is discussing the improvement of energy ef iciency of ships in order to reduce greenhouse gas emissions from ships. Currently, by applying an ORC power generation system using waste heat generated from ships, high energy conversion efficiency can be expected from ships. This technology uses an organic medium based on Freon or hydrocarbons as the working fluid, which evaporates at a lower temperature range than water. Through this, it is possible to generate steam (gas) and generate power at a low and low temperature relatively. In this study, the analysis of heat flow between the refrigerant and waste heat in the ORC power generation system, which is an organic Rankine cycle, is analyzed using 3D simulation techniques to determine the temperature change, velocity change, pressure change, and mass change of the fluid flowing of the WHRU (Waste Heat Recovery Unit) inside and the outside the structure. The purpose of this study is to analyze how the mass change affects the structure, and this study analyzed the heat transfer of the heat exchanger from the refrigerant and the exhaust gas of the ship's main engine in the ORC power generation system using this technique.

Thermodynamic Performance Analysis of Ammonia-Water Rankine Cycle and Organic Rankine Cycle Using Cold Energy of LNG (LNG 냉열을 이용하는 암모니아-물 랭킨 사이클과 유기 랭킨 사이클의 열역학적 성능 특성 해석)

  • KIM, KYOUNG HOON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.4
    • /
    • pp.363-371
    • /
    • 2020
  • Recently, the technologies to utilize the cold energy of liquefied natural gas (LNG) have attracted significant attention. In this paper, thermodynamic performance analysis of combined cycles consisting of ammonia Rankine cycle (AWR) and organic Rankine cycle (ORC) with LNG Rankine cycle to recover low-grade heat source and the cold energy of LNG. The mathematical models are developed and the effects of the important system parameters such as turbine inlet pressure, ammonia mass fraction, working fluid on the system performance are systematically investigated. The results show that the thermal efficiency of AWR-LNG cycle is higher but the total power production of ORC-LNG cycle is higher.