• 제목/요약/키워드: OPF

검색결과 143건 처리시간 0.033초

최적조류계산 분산처리 기법의 비교 (A Comparison of Distributed Optimal Power Flow Algorithm)

  • 김호웅;박만근;김발호;김정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1046-1048
    • /
    • 1999
  • This Paper compares two mathematical decomposition coordination methods to implementing the distributed optimal Power flow(OPF) using the regional decomposition: the Auxiliary Problem Principle(APP) and the Alternating Direction Method(ADM), a variant of the conventional Augmented Lagrangian approach. A case study was performed with IEEE 50-bus system.

  • PDF

Identification of the Strain JM-4151 Producing Nonactin, as Radical-producing Antibiotic

  • Lee, Jin-Man;Lee, Dong-Sun;Hong, Soon-Duck
    • Journal of Life Science
    • /
    • 제9권2호
    • /
    • pp.1-4
    • /
    • 1999
  • Nonactin, as a radical-producing antibiotic, was isolated from the cultural broth of the strain JM-4151. This strain was identified as Streptomyces viridochromogenes and designated S. viridochromogenes JM-4151. The antibacterial activity of nonactin against Bacillus subtilis was antagonized by the activity opf quercetin, an oxygen radical scavenger. This result suggests that oxygen radical formation might be the cause for the antibacterial activity of nonactin.

공액 경사법을 사용한 최적조류계산에 대한 새로운 접근법 (A New Approach to Optimal Power Flow using Conjugate Gradient Method)

  • 조한형;김원겸;김건중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.139-142
    • /
    • 1990
  • This paper presents a new approach to optimal power flow (OPF) problem using conjugate gradient method, using this method. We can obtain initial feasible solution and lagrangian multiplier without calculation of matrix inversion.Test experiment shows a desiriable result and a stable convergence characteristic.

  • PDF

혼잡에 의한 시장지배력 산정 방안 (Estimation of Local Market Power under Transmission Congestion)

  • 이동진;신영균;정구형;김발호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.494-496
    • /
    • 2003
  • Transmission congestion is one of the key factors to local market power in competitive electricity markets. This paper presents an alternative methodology in estimating market power under transmission congestion. The proposed methodology was demonstrated with the Optimal Power Flow(OPF).

  • PDF

되먹임된 단일모드 Nd:YAG Microchip Laser 의 혼돈스런 출렁임 (The Chaotic Oscillation of Single Mode Microchip Nd:YAG Laser with Modulated Optical Feedback Light)

  • 김재인;허형준;조규만
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2000년도 하계학술발표회
    • /
    • pp.248-249
    • /
    • 2000
  • 최근 "혼돈제어"라는 몇 가지 방식이 증명되어 여러 시스템에서 혼돈스런 출렁임을 제거하게 되었다. 처음으로 OGY(Ott Grebogi Yorke) 방법에 기초를 둔 Occasional Proportional Feedback(OPF) 방식이 Roy에 의해 고체레이저 system 에 적용되었다$^{(1)}$ . 또 High Frequency Injection(HFI) 방식으로도 혼돈을 제어할 수 있음이 발표되기도 했다$^{(2),(3)}$ . 우리의 실험에서는 단일모드로 발진하는 Nd:YAG 레이저에서 일어나는 혼돈현상을 관측하려 한다. (중략)

  • PDF

Dietary Manipulation and Increase in Plasma Unsaturated Fatty Acids in Sheep

  • Rajion, M.A.;Goh, Y.M.;Dahlan, I.;Salam Abdullah, A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제14권8호
    • /
    • pp.1073-1077
    • /
    • 2001
  • Forty three 7-month old, Barbados Black $Belly{\times}Malin$ crossbred sheep were used for the trial. They were allotted into three treatment groups fed varying levels of oil palm (Elaeis guineensis) frond pellets and commercial sheep pellets. Treatment diets were 80% commercial pellet+20 % (% w/w) oil palm frond pellet (CON group, n=15), 50% commercial pellet+50% oil palm frond pellet (% w/w) (HAF group, n=14) and 80% oil palm frond pellet+20% (% w/w) commercial pellet (OPF group, n=14). The plasma fatty acid profiles from these animals were compared before and after 14 weeks of feeding. Results showed that total unsaturated fatty acid content in the CON group had increased by 10% (p<0.01) from the pre-treatment values. All three treatment groups had significantly different plasma n-6 and n-3 polyunsaturated fatty acid contents at the end of the trial. In fact, the CON group had significantly (p<0.01) more n-6 polyunsaturated fatty acid content compared to its own initial values, and also the values from the HAF and OPF groups. However there was a significant (p<0.01) decline in plasma n-3 polyunsaturated fatty acids in all groups. The final total unsaturated to saturated fatty acid content ratio was significantly (p<0.01) highest in the CON group, demonstrating the high plasma unsaturated fatty acid content in these animals. This study shows the plasma unsaturated fatty acids in sheep can be increased by dietary manipulation.

Immunomodulatory Effects of a Methanol Extract from Opuntia ficus indica on Murine Splenocytes

  • Ahn, Gin-Nae;Kim, Jin-Hee;Park, Eun-Jin;Lim, Yoon-Kyu;Jeon, You-Jin;Jee, Young-Heun
    • Food Science and Biotechnology
    • /
    • 제18권6호
    • /
    • pp.1316-1321
    • /
    • 2009
  • Multiple beneficial properties of Opuntia ficus indica (OPF) are well established. In the present study, we have investigated the immunological role of OPF extract (OPFE) on murine splenocytes. OPFE dose- and time-dependently enhanced the proliferation of splenocytes without cytotoxicity. Our results also showed that the number of $CD4^+$ helper T cells and CD45R/$B220^+$ pan B cells increased markedly, but not $CD8^+$ cytotoxic T cells or $CD11b^+$ granulocytes/macrophages. In addition, OPFE significantly decreased the production levels of T helper (Th) 1 type cytokines, interferon (IFN)-$\gamma$, and tumor necrosis factor (TNF)-$\alpha$, although had no significantly differences in those of interleukin (IL)-4, a Th2 type cytokine in concanavalin A (Con A)-stimulated blastogenic cells. Furthermore, OPFE alone strongly increased IL-4 production and decreased TNF-$\alpha$ production even in the absence of Con A. On the basis of these results, this study suggests that OPFE enhances immunity by regulating the pro- and anti-inflammatory response, indicating that this extract exerts a marked immunomodulatory effect, confirming its usefulness as therapy for immune-related diseases.

OPF with Environmental Constraints with Multi Shunt Dynamic Controllers using Decomposed Parallel GA: Application to the Algerian Network

  • Mahdad, B.;Bouktir, T.;Srairi, K.
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권1호
    • /
    • pp.55-65
    • /
    • 2009
  • Due to the rapid increase of electricity demand, consideration of environmental constraints in optimal power flow (OPF) problems is increasingly important. In Algeria, up to 90% of electricity is produced by thermal generators (vapor, gas). In order to keep the emission of gaseous pollutants like sulfur dioxide (SO2) and Nitrogen (NO2) under the admissible ecological limits, many conventional and global optimization methods have been proposed to study the trade-off relation between fuel cost and emissions. This paper presents an efficient decomposed Parallel GA to solve the multi-objective environmental/economic dispatch problem. At the decomposed stage the length of the original chromosome is reduced successively and adapted to the topology of the new partition. Two subproblems are proposed: the first subproblem is related to the active power planning to minimize the total fuel cost, and the second subproblem is a reactive power planning design based in practical rules to make fine corrections to the voltage deviation and reactive power violation using a specified number of shunt dynamic compensators named Static Var Compensators (SVC). To validate the robustness of the proposed approach, the algorithm proposed was tested on the Algerian 59-bus network test and compared with conventional methods and with global optimization methods (GA, FGA, and ACO). The results show that the approach proposed can converge to the near solution and obtain a competitive solution at a critical situation and within a reasonable time.

A Method to Calculate Charge for Reactive Power Service under Competition of Electric Power Utilities

  • Ro, Kyoung-Soo;Park, Sung-Chul
    • KIEE International Transactions on Power Engineering
    • /
    • 제11A권4호
    • /
    • pp.39-44
    • /
    • 2001
  • As electric power systems have been moving from vertically integrated utilities to a deregulated environment, the charging of reactive power management is a new challenging them for market operators. This paper proposes a new methodology to compute the costs of providing reactive power management service in a competitive electrical power market. The proposed formulation, which is basically different from those shown in the literature, consists of two parts. One is to recover investment capital costs of reactive power supporting equipment based on a reactive power flow tracing algorithm. The other is to recover operational costs based on variable spot prices using the optimal power flow algorithm. The charging shapes resulted from the proposed approach exhibit a quite good meaning viewed from a practical sense. It turns out that reactive power charged are mostly due to recovery of capital costs and slightly due to recovery of operational costs. The methods can be useful in providing additional insight into power system operation and can be used to determined tariffs of a reactive power management service.

  • PDF

Steady-state Operational Strategies of UPFC in the KEPCO Transmission System

  • Chang, B.H.;Choo, J.B.;Xu, X.K.;Lam, B.P.
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권3호
    • /
    • pp.161-167
    • /
    • 2003
  • This paper presents a study performed to investigate the steady-state operational strategies of UPFCs in the Jeollanam-Do system in Korea. The objective of the study was to determine the UPFC operating points under normal and contingency conditions. The study consists of developing load flow models to simulate different load levels with and without UPFCs in the system, assessing the effectiveness of UPFCs by contingency analysis, and introducing optimal corrective actions for removing voltage problems caused by contingencies. The paper describes analytical tools, models and approach. It also includes analysis and discussion of the study results. The paper contributes to the area of transmission operational studies with FACTS applications.