• 제목/요약/키워드: OPERATION

검색결과 48,724건 처리시간 0.058초

A Feasibility Study on Adopting Sliding Pressure Operation for Drum Type Boiler

  • Baek, SeHyun;Kim, HyunHee;Park, SangBin;Kim, YoungJoo;Park, Hoyoung
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권3호
    • /
    • pp.403-407
    • /
    • 2016
  • In general, drum-type boilers are designed for base load duty and applied under constant pressure operation mode. Recently, however conditions often occur that even drum-type boilers have to operate at partial load conditions. A feasibility study on adopting the sliding pressure operation for drum-type boiler was conducted, and corresponding performance changes and effects on the equipment were analyzed by utilizing a process simulation model. As a result, the conclusion was reached that drum type boilers are able to adopt the sliding pressure operation and can improve of net efficiency at part load operation in spite of the Rankine cycle efficiency reduction due to the decreases in main steam pressure. Because of thank to improvement of high pressure turbine stage-1 internal efficiency and power savings of boiler feed water pump. The sliding pressure operation is advantageous in terms of stress level relief for boiler tube as well as maintaining the rating steam temperature at part load condition. However, cautions are required because the drum boilers have poor dynamic response characteristics which may get worse during the sliding pressure operation.

Secure and Energy-Efficient Join-Leave Operations in ZigBee Network

  • Kim, Bong-Whan;Park, Chang-Seop
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제7권11호
    • /
    • pp.2874-2892
    • /
    • 2013
  • Since security plays an important role in several ZigBee applications, such as Smart Energy and medical sensor applications, ZigBee Specification includes various security mechanisms to protect ZigBee frames and infrastructure. Among them, the Join and Leave operations of ZigBee are investigated in this paper. The current Join-Leave operation is protected by the network key (a kind of group key). We claim it is not adequate to employ the network key for such purpose, and propose a new Join-Leave operation protected by the application link key (a kind of pairwise key), which is based on a more efficient key management scheme than that of ZigBee. Hence, the original Join operation consists of a total of 12 command frames, while the new Join operation consists of only 6 command frames. In particular, the security of the proposed Join-Leave operation is equivalent to or better than that of the original Join-Leave operation. The new Join-Leave operation is extensively analyzed in terms of security and efficiency, and compared with the original Join-Leave operation of ZigBee.

대추수확기의 집과시스템 개발에 관한 연구 (Development of a Collecting System for Jujube Harvester)

  • 이상우;김도형;이창규;서신원;허윤근
    • Journal of Biosystems Engineering
    • /
    • 제31권6호
    • /
    • pp.500-505
    • /
    • 2006
  • Jujube is one of korean most favorite fruits. Harvesting operations of the jujube farming, however, completely depend on hand labor. Especially, collecting operation requires about three times of hand labor compared with separate operation by impacting or shaking of twigs in the hand-harvesting system of jujube fruits. Consequently, jujube farmers sincerely demand the mechanization of the collecting operation of jujube fruits in the harvesting operation. A new collecting system was designed and constructed five parts-collecting pad, guide ring system, sorting system, frame with driving system, and handle with operation levers, which performed collecting operation of jujube fruits without missing fruits in five part functions, however, an extra future more deliberate study would need how to handle conveniently the collecting pad of the prototype in the narrow space of row of the jujube farm.

Protection for a Wind Turbine Generator in a Large Wind Farm

  • Zheng, Tai-Ying;Kim, Yeon-Hee;Kang, Yong-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권4호
    • /
    • pp.466-473
    • /
    • 2011
  • This paper proposes a protection algorithm for a wind turbine generator (WTG) in a large wind farm. To minimize the outage section, a protection relay for a WTG should operate instantaneously for an internal fault or a connected feeder fault, whereas the relay should not operate for an internal fault of another WTG connected to the same feeder or an adjacent feeder fault. In addition, the relay should operate with a delay for an inter-tie fault or a grid fault. An internal fault of another WTG connected to the same feeder or an adjacent feeder fault, where the relay should not operate, is determined based on the magnitude of the positive sequence current. To differentiate an internal fault or a connected feeder fault from an inter-tie fault or a grid fault, the phase angle of the negative sequence current is used to distinguish a fault type. The magnitude of the positive sequence current is then used to decide either instantaneous operation or delayed operation. The performance of the proposed algorithm is verified under various fault conditions with EMTP-RV generated data. The results indicate that the algorithm can successfully distinguish instantaneous operation, delayed operation, or non-operation depending on fault positions and types.

자동화 컨테이너터미널에서 운송장비의 운영방안에 관한 연구 (A Study On Operation Method of Handling Equipments in Automated Container Terminals)

  • 최형림;박남규;박병주;권해경;유동호
    • 산업공학
    • /
    • 제17권2호
    • /
    • pp.233-241
    • /
    • 2004
  • The main subject to become a hub port is automation. The automated container terminal has already operated in advanced ports and it has been planned for the basic planning and operation design in domestic case. The key of automated container terminal is effective operation of both ATC(automated transfer crane) and AGV(automated guided vehicle) which is automated handling equipments. This is essential to productivity of automated container terminal. This study suggests the most optimal method of equipment operation in order to minimize loading time using each three types of effective ATC operation methods and AGV dispatching rules in automated container terminals. As the automated equipment operation causes unexpected deadlocks or interferences, it should be proceeded on event-based real time. Therefore we propose the most effective ATC operation methods and AGV dispatching rules in this paper. The various states occurred in real automated container terminals are simulated to evaluate these methods. This experiment will show the most robust automated equipment operation method on various parameters(the degree of yard re-marshaling, the number of containers and AGV)

효율적인 듀얼 사이클을 위한 야드 트랙터 통제 시스템 (Efficient Yard Tractor Control Systems for the Dual Cycling)

  • 정창윤;신재영
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2011년도 추계학술대회
    • /
    • pp.170-171
    • /
    • 2011
  • 전체 수 출입 공급망 사슬관리에 있어서 항만의 운영 효율성은 아주 중요하다. 컨테이너 터미널에서는 안벽작업의 효율성을 극대화하기 위하여 더블 사이클과 듀얼 사이클 방법이 소개되었고, 야드 트랙터 할당의 효율성을 높이기 위해서 야드 트랙터(YT) 풀링 방법이 제시되었다. 모형은 시뮬레이션 분석 소프트웨어인 Arena를 이용하여 수립되었다.

  • PDF

수리해석(水理解析) 모형(模型)을 이용한 다수원(多水源) 송수계통(送水系統)의 연계(連繫) 운영(運營) 방안(方案) 경제성(經濟性) 평가(評價) - 거제시(市)를 대상(對象)으로 - (Feasibility Study on the Conjunctive Operation of Water Transmission Systems from Multiple Source with Applying EPAnet)

  • 류태상;하성룡
    • 상하수도학회지
    • /
    • 제21권5호
    • /
    • pp.609-619
    • /
    • 2007
  • The objective of this paper is to evaluate the feasibility of conjunctive Operation between Multi-regional water supply networks from multiple source as a effective way to meet two conditions: to minimize the electric cost for providing water demanded and meet the water flow rate for satisfying customers. EPAnet Model is used to calculate a hydraulic water distribution condition based on an integrated operation of water supply systems located in short distance. The modeling was conducted on several simulation cases including the individual operation by existing inter-regional water supply networks within short distance, the conjunctive operation of more than two existing networks with valve fully closed and full open constraint. As a study distribution system, water supplying systems of the Geojae-city in the Geongsang Namdo Province was selected and investigated. It was found that a well-allocated water supply scheme based on a conjunctive operation promises to save the electric cost and satisfy all operational goals such as stability and revenues during the period. The result such as unit district costs, pareto optimum pump combination sets will be applied to the optimization for a conjunctive operation of existing inter-regional water supply networks within short distance.

연속적 재발성 미성숙 기형종의 외과적 치료 (Surgical Experience of Recurrent Immature Teratoma - Report of a case -)

  • 홍민수
    • Journal of Chest Surgery
    • /
    • 제24권8호
    • /
    • pp.792-796
    • /
    • 1991
  • Immature teratoma can be viewed as intermediate between mature teratoma and embryonal carcinoma. Unlike the mature teratoma, elements of the three perm cell layers are incompletely differentiated and not arranged in organoid fashion In some area, more mature forms of these tissues may also be seen, Although this tumor is clearly malignant, they may not display clear-cut cytologic features of malignancy. The clinical prognosis is poor. We have experienced one case of recurrent immature teratoma. In first operation[1987, April], tumor of anterior mediastinum was removed with wedge resection of ant. segment of RUL % med. segment of RML. In 2nd operation[1990, June], recurrent teratoma of right inner thoracic wall was resected with partial 5th rib resection and wedge resection of lat. segment of middle lobe. Two months later, the 3rd operation[1990, September] was done, which was a removal of mass on thoracic wall near sup, segment of RLL and partial rib resection of 3rd, 4th & 5th. In November 1990, last operation[4th operation] was made. It was enucleation of walnut sized tumor located between medial segment of RML, and 4th. intercostal space, well encapsulated with endothoracic fascia and invaded into lung parenchyme, Adjuvant chemotherapy was done after each operation, but radiotherapy[5000 Rad] was done only after 1st operation. There was no evidence of recurrence after last operation. The patient is well-being still now.

  • PDF

가변 지속시간을 갖는 이벤트 기반 원격제어 (Event Based Tele-Operation with Variable Holding Time)

  • 박준영;박장현
    • 한국정밀공학회지
    • /
    • 제19권12호
    • /
    • pp.70-77
    • /
    • 2002
  • Necessity of the tole-operation has been increased in many fields. Since the Internet is inexpensive and available all over the world, it is a strong candidate for the transmission media of the tole-operation. However, the Internet has random time delays that may cause instability in the system especially if the tole -operation is bilateral. In the past few years many attempts have been made to overcome the random time delay, So far, they are still insufficient in terms of performance. The ‘Variable holding time’ is introduced to improve the performance of the ‘Event based tole-operation’ which controls a system with a non-time action reference. By holding each event for proper time, the system can quickly respond and be stabilized. The proper holding time should be selected based on the characteristics of the task that the system performs. The factors that reflect those characteristics are investigated. The fuzzy logic is employed to obtain the proper holding time for each event while the tole-operation system is in operation. The experimental results presented in this paper verify effectiveness of the proposed method.

디젤발전기의 출력비에 따른 효율을 고려한 마이크로그리드에서의 BESS와 디젤발전기의 최적 운영 기법에 관한 연구 (A Study on Methodology of Optimal Operation of BESS and Diesel Generators in a Microgrid Considering Efficiency Characteristics According to the Power Ratios of Diesel Generators)

  • 이병하
    • 전기학회논문지
    • /
    • 제65권4호
    • /
    • pp.539-546
    • /
    • 2016
  • With the growing interest of microgrid systems all over the world, many studies on microgrid operation are being carried out. The battery energy storage system(BESS) and the diesel generator are key equipments in the microgrid. In this paper, we analyze the characteristics of fuel consumption according to the power ratio of the diesel generator. Then, the formula to represent the unit cost of generation according to the power ratio of the diesel generator is derived. A new modeling of battery operation is presented considering the lifetime reduction according to increasing the cycles of charge/discharge operation of the battery. The methodology of determining the optimal operation of the battery and the diesel generator is presented by the use of the formula of fuel consumption of the diesel generator and the new modeling of battery operation. It is shown that this optimization methodology can be applied effectively for economical operation of the BESS and the diesel generator of a microgrid by case studies.