• Title/Summary/Keyword: OPEN WATER

Search Result 1,861, Processing Time 0.033 seconds

A Study on Indoor Radon Concentrations in Urban Area (도시 일부지역에서의 실내 라돈농도에 관한 연구)

  • 김순애;백남원
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.2
    • /
    • pp.89-98
    • /
    • 2002
  • This study was taken in general hospital, hotel, shopping center, underground cafe, school, house, for the purpose of investigating the distribution of indoor radon concentration in urban area, by E-PERM which approved U.S. EPA, between August and November 1999. There are two sampling Places were exceed 148 ㏃/㎥(4 pCi/L; U.S EPA remedial level), difference mean is 24.0㏃/㎥ when compared with underground vs. aboveground indoor radon concentration in the same building and ratio is 1.6, so underground area is higher than aboveground (p<0.05). Influencing factors were examined. They related to the location of sampler(detector) open or near the door is lower radon concentration than inside portion, which explains probably open area has better ventilated air and dilutes indoor radon concentration. Temperature has a negative relationship (p<0.05) with indoor radon concentration and relative humidity has a positive (p<0.05) Simultaneously to investigate water radon concentration, collected piped-water and the results were very low, which is the same in piped-water concentration other countries. In conclusion, underground indoor radon concentration is higher than aboveground. Concentration was related to sampling spot, open portion is lower than inside. Higher the temperature, lower the indoor radon concentrations. On the other hand higher the relative humidity, higher the indoor radon concentrations. Indoor radon concentration is influenced by sampling point, temperature, relative humidity.

Study on CFD Methodology for a Open Channel Type UV Reactor (전산유체역학을 활용한 개수로형 UV소독장비의 해석기법 연구)

  • Hwang, Woochul;Bak, Jeong-Gyu;Kim, Hyunsoo;Lee, Kunghyuk;Cho, Jinsoo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.2
    • /
    • pp.54-59
    • /
    • 2015
  • The performance of UV reactor which is used in water treatment is strongly affected by UV fluence rate and water flow in the UV reactor. Therefore, CFD tools are widely used in designing process of UV reactors. This paper describes the development of a computational fluid dynamics (CFD) methodology that can be used to calculate the performance of open channel type UV reactor used in wastewater treatment plant. All computations were performed using commercial CFD code, CFX, by considering three dimensional, steady, incompressible flow. The Eulerian-Eulerian multi-phase method were used to capture the water-air interface. The MSSS model, provided by UVCalc3D, was used to calculate the UV intensity field. The numerical predictions and calculated UV Dose were compared with experimental dataset to validate the CFD methodology. The reactor performance based on MS2 log reduction was well matched with measurements within 6%.

Hydrualic Model Test for Siphon Spillway Capable of Controlling Discharge (유량조절이 가능한 사이펀 여수로 수리모형실험)

  • Jung, Jae-Sang;Jang, Eun-Cheol;Lee, Changhoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.43-47
    • /
    • 2019
  • In this study, capability of an air slot in a siphon spillway for controlling outflow discharge is investigated through hydraulic experiments. Arc and rectangular shapes of air slot are considered and the open area of air slot can be varied. Complex air-regulated flow occurs inside the the siphon spillway when the air slot is installed on it. The same discharge is measured at the same water level inside the reservoir when the water level rises or falls. Nondimensional discharge through the siphon spillway increases slowly as nondimensional open area of the air slot increases. The hydraulic experiments show that the control of outflow discharge of siphon spillway is possible by controlling the open area of the air slot.

  • PDF

2D Numerical Simulations of Bubble Flow in Straight Pipes (직관내 기포의 흐름에 대한 2차원 수치 모의)

  • Lee, Tae Yoon;Nguyen, Van Thinh
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.386-390
    • /
    • 2016
  • Water aeration is an effective water treatment process, which involves the injection of air or air-water mixture into water treatment reservoir commonly through pipes. The main purpose of water aeration is to maintain healthy levels of dissolved oxygen (DO), which is the most important water quality factor. The pipes' operating conditions are important for controlling the efficiency and effectiveness of aeration process. Many studies have been conducted on two-phase flows in pipes, however, there are a few studies to deal with small s ale in millimeter. The main objective of this study is to perform 2-dimensional two-phase simulations inside various straight pipes using the computational fluid dynamic (CFD) OpenFOAM (Open source Field Operation And Manipulation) tools to examine the influence of flow patterns on bubble size, which is closely related to DO concentration in a water body. The both flow regimes, laminar and turbulence, have been considered in this study. For turbulence, Reynolds-averaged Navier-Stokes (RANS) has been applied. The coalescence and breakage of bubbles caused by random collisions and turbulent eddies, respectively, are considered in this research. Sauter mean bubble diameter and water velocity are compared against experimental data. The simulation results are in good agreement with the experimental measurements.

  • PDF

Simulation of Open-Loop Borehole Heat Exchanger System using Sand Tank Experiment and Numerical Model (토조 및 수치모형을 이용한 개방형 지중 열교환 시스템 모의)

  • Lee, Seong-Sun;Bae, Gwang-Ok;Lee, Kang-Kun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.489-492
    • /
    • 2007
  • Understanding the thermohydraulic processes in the aquifer is necessary for a proper design of the aquifer thermal energy utilization system under given conditions. Experimental and numerical test were accomplished to evaluate the relationship between the geothermal heat exchanger operation and hydrogeological conditions in the open-loop geothermal system. Sand tank experiments were designed to investigate the open-loop geothermal system. Water injection and extract ion system as open-loop borehole heat exchanger was applied to observe the temperature changes in time at injection well, extraction well and ambient groundwater. The thermohydraulic transfer for heat storage was simulated using FEFLOW for two cases of extraction and injection phase operation in sand tank model. As one case, the movement of the thermal plume was simulated with variable locations of injection and extraction well. As another case, the simulation was performed with fixed location of injection and extraction well. The simulation and experimental results showed that the temperature distribution depends highly on the injected water temperature and the length of injection time and the groundwater flow and pumping rate sensitively affect the heat transfer.

  • PDF

Normal Depth of Best Section (최량수리단면의 등류수심)

  • Yoo, Dong-Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.6
    • /
    • pp.729-736
    • /
    • 2002
  • The computation of normal depth is one of the most important parts in the design of open channel flow, and the best section is in general the most economic section in the case of constructing artificial open channels. Thus the determination of the normal depth of the best section is the essential item in the design of most open channel flows. To estimate the frictional forces a power law is introduced, which is applicable to most situations in open channel flows. Explicit and consistent forms of equations are deduced for the calculation of normal depth of triangular, rectangular and trapezoidal best sections. Furthermore the equations of normal depth are found to have the same form as those of pipe diameter for the design of pipe flow.

Under Water Sonar Transducer Using Terfenol-D Magnetostrictive Material

  • Son, Derac;Cho, Yuk
    • Journal of Magnetics
    • /
    • v.4 no.3
    • /
    • pp.98-101
    • /
    • 1999
  • In this work we htave constructed an under water sonar transducer using Terfenol-D rod employing open magnetic circuit. Normally Sonar transducer using Terfenol-D was designed under closed magnetic flux return path, and permanent magnet for dc bias marnetic field, but high magnetic field should be applied to the transducer coil for high sound power and it brings temperature increase inside of the transducer. To improve this heat dissipation problem, we have designed an open magnetic circuit type transducer and we can get 200 dB (re. 1 Pa @ 1m) sound power for the input power of 650 VA.

  • PDF

The Study on the Corrosion Behavior of Al-alloy Radiator for Automobile in Fresh Water (청수 중에서 자동차용 Al합금 방열기의 부식거동에 관한 연구)

  • 임우조;이상열;윤대영
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.38 no.4
    • /
    • pp.265-270
    • /
    • 2002
  • Most of all the mechanical devices are becoming more high-speed and high-power as well as their used condition being more pollution with rapid development in industrial part. So, it is necessary for these devices to equip cooling system to overcome that kind of severe using condition. Industrial development and income increase causes rapid increase in using fossilenergy and it results in accelerating environmental pollution owing to the increasement in emission of air pollution substance. Specially, fresh water like stream and river water is acidified. Therefore, corrosion damage is accelerated in radiator for automobile that is using acidified water. So, in this study, corrosion test was carried out in distilled and tap water for the investigation on the corrosion behavior of Al-alloy that is using as material for radiator of automobile The main results obtained are as follows According to increase of temperature, open circuit potential is decreased in fresh water. And open circuit potential after deaeration is lower than that before deaeration. Corrosion current density in distilled water is less drained than that of tap water. And Corrosion current density after deaeration is less drained than that before deaeration.

Preferred masking levels of water sounds according to various noise background levels in small scale open plan offices (소규모 개방형 사무실 배경 소음 레벨에 따른 최적 물소리 마스킹 레벨)

  • Tae-Hui Kim;Sang-Hyeon Lee;Chae-Hyun Yoon;Hyo-Won Sim;Joo-Young Hong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.6
    • /
    • pp.617-626
    • /
    • 2023
  • This study aims to investigate the preferred sound level of water sound for various levels of open-plan-office noise regarding soundscape quality and speech privacy. And assessment of the work efficiency of the water sound. For the laboratory experiment, office noise was recorded using a binaural microphone in a real open-plan office. For the assessment of the soundscape quality and speech privacy, Overall Soundscape Quality (OSQ) and Listening Difficulty (LD) were evaluated under three different sound levels (55 dBA, 60 dBA, and 65 dBA) and five different signal-to-noise ratios (SNR -10 dB, -5 dB, 0 dB, +5 dB, and +10 dB). After the evaluation, the preferred SNR was proposed according to OSQ and LD. For the assessment of to work efficiency of water sound, this study evaluated the cognitive performance of both of the condition noise only and combine the water sound with office noise. The results showed that LD increased as the water sound level increased, but OSQ decreased. When the water sound level was more than the office noise level, the OSQ decreased from noise only. Therefore, considering OSQ and LD, the preferred SNR of water sound was -5 dB for all noise levels. At the preferred level of water sound, the cognitive performance results were shown to decrease at 55 dBA compared to noise only, but at 60 dBA and 65 dBA combine the water sound results were increased than the noise only.

Effects of Season, Housing and Physiological Stage on Drinking and Other Related Behavior of Dairy Cows (Bos taurus)

  • Lainez, Marielena Moncada;Hsia, Liang Chou
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.10
    • /
    • pp.1417-1429
    • /
    • 2004
  • The objective of the paper was to study the drinking and other related behavior of dairy cows (Bos taurus). There were 142 Holstein dairy cows observed and compared in this study. The experiment was designed on the basis of two different housing systems (wet pad with forced ventilation cooling house and open house); two different seasons (winter and summer); four different stages (high milk yielding cows, low milk yielding cows, dry cows, and heifers); and grouping (home and visitor animals). All cows had free access to water. Dairy cows spent 13.8 min/day drinking in wet-pad house and 11.7 min/day in open house. owever, there was no significant difference in the duration of water drinking between these two housing systems (p>0.05). The water consumption was significantly higher in wet-pad housed animals (68 L/day) than open-housed animals (31.5 L/day) (p<0.05). A significant interaction between housing and grouping (p<0.05) was found. Home and visitor animals spent more time drinking in open house, wet-pad house, respectively. A highly significant interaction was found between housing and drinking time during the day (p<0.001). Animals in open house drank more during the morning (6:00 to 10:00 h), whereas wet-pad housed animals drank in the afternoon (14:00 to 15:00 h) and evening (18:00 to 20:00 h). The average time a cow spent in drinking in summer was not ignificantly different from that of drinking in winter. However, the water intake was significantly higher in summer (61.9 L/day) than in winter (38.6 L/day) (p<0.05). Drinking activity showed a highly significant interaction between season and physiological stage (p<0.01). High milk yield cows spent more time drinking in summer than in winter, whereas cows in all other stages followed the opposite drinking pattern. Grouping exchange did not influence the drinking behavior of dairy cows in either season (p>0.05); both home and visitor animals spent almost the same time in drinking water. A strong significant interaction between season and time during the day was found(p<0.01), suggesting that animal's high drinking frequency occurred during the daytime for both seasons, with a peak midday in winter and two peaks at 10:00 h in the morning and 19:00 h in summer. Thus, drinking behavior was associated with the cooler time of day in summer and with the warmer hours of day in winter. High and low milk yielding cows and heifers spent 15.3 min/day, 14.3 min/day, and 12.8 min/day, respectively, in water drinking activity, but there was no significant difference among them (p>0.05). There was, however, a significant difference in water drinking activity found in dry cows, which spent less time in drinking at 8.2 min/day (p<0.05).