• Title/Summary/Keyword: OIL

Search Result 15,728, Processing Time 0.035 seconds

A Case Study for Influence of Form-oil on Surface Condition of Steam-cured Concrete (증기양생 콘크리트 표면상태에 대한 박리제의 영향 사례연구)

  • Han, Sang Hoon;Yoon, Ju Yong;Hong, Ki Nam;Choi, Jae Wan;Lim, June Woo
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.1
    • /
    • pp.52-56
    • /
    • 2013
  • The purpose of this study is to evaluate the influence of form-oil on steam-cured concrete surface condition. Based, viscosity(high, medium, low) and flash point($26^{\circ}C$, $70^{\circ}C$) of form oil were considered as test variables. The digital image process method was applied for the extraction of air-void area from concrete surface. Test result showed that oil-based form oil reduced air-void by approximately 46% compared to water-based form oil, and the higher the viscosity was, the smaller air-void rate was. In addition, it was conformed that flash point of form oil had a considerable influence on the surface condition of steam-cured concrete.

A Study of design oil lubricator system using WLAN on based flexible link system (유연링크시스템 기반에서 WLAN 방식을 적용한 퓨전 주유시스템의 구조 설계에 대한 연구)

  • Kim, W.Y.;Hong, J.H.;Jung, J.H.;Song, G.Y.;Song, W.J.;Jung, Y.H.;Kim, H.J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.137-140
    • /
    • 2002
  • For the satisfying performance of a oil lubricator, design of a oil controller for the system which meets the required specifications and its supporting hardware that keep their functioning is important. Among the hardware of a control system, oil system are most vulnerable to malfunction. Thus it is necessary to keep track of accurate and reliable oil readings for good fusion oil lubricator performance. In case of oil lubricator, data loss, ssr trigger error faults, they are detected by examining the data system output values and the major values of the system, and then the faults are recognized by the analysis of symptoms of faults. If necessary electronic-sensor values are synthesized according to the types of faults, and then they are used for the controller instead of the raw data. In this paper, a fast-32bit cpu micorprocessor applied to the control of flexible link system with the sensor fault problems in the error module for exact positioning to show the applicability. It is shown that the fusion oil lubricator can provide a satisfactory loop performance even when the sensor faults occure

  • PDF

Microbial Consortia in Oman Oil Fields: A Possible Use in Enhanced Oil Recovery

  • Al-Bahry, Saif N.;Elsahfie, Abdulkader E.;Al-Wahaibi, Yahya M.;Al-Bimani, Ali S.;Joshi, Sanket J.;Al-Maaini, Ratiba A.;Al-Alawai, Wafa J.;Sugai, Yuichi;Al-Mandhari, Mussalam
    • Journal of Microbiology and Biotechnology
    • /
    • v.23 no.1
    • /
    • pp.106-117
    • /
    • 2013
  • Microbial enhanced oil recovery (MEOR) is one of the most economical and efficient methods for extending the life of production wells in a declining reservoir. Microbial consortia from Wafra oil wells and Suwaihat production water, Al-Wusta region, Oman were screened. Microbial consortia in brine samples were identified using denaturing gradient gel electrophoresis and 16S rRNA gene sequences. The detected microbial consortia of Wafra oil wells were completely different from microbial consortia of Suwaihat formation water. A total of 33 genera and 58 species were identified in Wafra oil wells and Suwaihat production water. All of the identified microbial genera were first reported in Oman, with Caminicella sporogenes for the first time reported from oil fields. Most of the identified microorganisms were found to be anaerobic, thermophilic, and halophilic, and produced biogases, biosolvants, and biosurfactants as by-products, which may be good candidates for MEOR.

Experimental Quality Characteristics for Water Removal in Inner Flushing Oil in Process Piping of Offshore Plant (해양플랜트 프로세스 배관 내경 플러싱 오일속에서 수분제거를 위한 실험적 품질 특성)

  • Park, Chang-Soo;Sung, Ki-Young;Han, Seong Jong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.6
    • /
    • pp.797-805
    • /
    • 2019
  • An important problem of offshore plant process piping is equipment accidents due to the removal of fine metal debris and foreign substances in the pipes that deliver fluids such as hydraulic oil, lubricating oil and thermal oil. Temporary flushing equipment to remove debris uses fluid equipment of centrifugal pump and gear pump to prevent equipment accident of offshore platform. The equipment manufacturer requires the shipyard to have a cleanliness rating inside the pipe to meet the international standards ISO4406 and NAS1638 quality levels to prevent damage to the equipment sold. The quality of the internal flushing of pipes conforms to the regulations suggested by the equipment manufacturer. In this paper, three types of electric heater capacity, which is a method of evaporating and removing water inside a pipe during an oil flushing process, were compared. In addition, the study was conducted to remove the flushing oil in the pipe and to improve oil quality.

A Study on the Lubrication Flow Distribution in a Six-speed Automatic Transmission Valve Body (6속 자동변속기 밸브바디의 윤활오일유량 분배 특성 연구)

  • Kim, Jin-Yong;Na, Byung-Chul;Lee, Kye-Cheul
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.2
    • /
    • pp.79-84
    • /
    • 2011
  • In general, a valve body of the automatic transmission(AT) is controlled by the clutch, the brake and lubricating oil flow in a hydraulic system and lubricant flow for each valve can be adjusted independently. To increase the lifetime of AT, the lubrication flow rate in a valve body for a 6 speed AT based parallel hybrid electric vehicle must be provided with proper oil distribution and control. In this study, we carried out several experiments without the inner parts of AT and with a AT assembly. The variation of the flow rate on oil temperature and pressure between an oil supply port and the outlets of the lubrication port was evaluated and analyzed. In the case of AT without the inner parts, it was evident that as the oil required for an operation of the clutch and brake was discharged from the outlet port, the flow rate from each lubrication port is decreased. However, the flow rate of the AT assembly was slightly increased. In addition, the lubrication flow rate was increased with increasing the oil temperature, and also it was reduced with increasing the oil pressure. Details of the resulting data are discussed.

Analysis of Optical Characteristics of Oil Immersion Lens in Aqueous Environment (액상유체 오일 이멀전 렌즈의 광학 물성치 해석)

  • Choi, Hae Woon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.11
    • /
    • pp.18-23
    • /
    • 2019
  • The oil immersion method can be used to create objective lenses with long working distances without sacrificing the focusing resolution for laser processing. In this study, a space in which air or oil can be filled was formed in the middle of a lens for analyzing the optical properties of a liquid-oil immersion lens. As the refractive media, air and oils of different refractive index values (1.2 and 1.5, respectively) were used. A simulation was conducted in the ZEMAX software environment using the ray-tracing technique, and the performance of the oil immersion lens was verified by determining its image distortion and focal length (FL) in each medium. In the case of air, the calculated FL was 0.813 mm, whereas the imaged FLs were 1.594 mm and 8.126 mm when the refraction indices were 1.2 and 1.5, respectively. The FL of an oil immersion lens could be increased considerably. In terms of image distortion, the oil immersion lens exhibited little distortion at the center in all cases, but different degrees of image distortion were observed at different points away from the center depending on the refraction index degree.

A Study on Three-Phase Separation Efficiency according to the Diffusion Plate of a High-Speed Centrifugal Separator (고속 원심분리장치의 확산판에 따른 상 분리효율에 관한 연구)

  • Lee, Choon-Man;Jeong, Ho-In
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.10
    • /
    • pp.99-103
    • /
    • 2019
  • Recently, as the high-precision machinery industry has developed rapidly, peripheral equipment has been developed to improve machining efficiency. Peripheral equipment for machining includes cooling units, housings, oil separators, and much more. Oil, such as cleaning and cutting fluids, is used for machining. When waste oil is reused, the contamination of the workpieces and reduction in machining accuracy are generated by the waste oil, including sludge. Therefore, the development of an oil separator is necessary for efficiently separating oil, water, and sludge. The purpose of this study is to analyze the oil separation efficiency and flow characteristics of a high-speed centrifugal separator according to the rotation velocity and diffusion plate. The oil separation efficiency and flow characteristics were analyzed using hydrodynamic theory and computational fluid dynamics (CFD). The results of this study will be used as basic data for the development of a high-speed centrifugal separator.

Experimental Study on Effects of PAG Oil for $CO_2$ Evaporation Heat Transfer (PAG 오일이 $CO_2$ 증발열전달에 미치는 영향에 관한 실험적 연구)

  • Lee, Sang-Jae;Kim, Dae-Hoon;Choi, Jun-Young;Lee, Jae-Heon;Kwon, Young-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.5
    • /
    • pp.357-363
    • /
    • 2008
  • In order to investigate $CO_2$ heat transfer coefficient and pressure drop by PAG oil concentration during $CO_2$ evaporation, the experiment on evaporation heat transfer characteristics in a horizontal micro-fin tube was performed. The experimental apparatus consisted of a test section, a DC power supply, a heater, a chiller, a mass flow meter, a pump and a measurement system. Experiment was conducted for various mass fluxes($400{\sim}1200\;kg/m^2s$), heat fluxes($10{\sim}30\;kW/m^2$) and saturation temperatures ($-5{\sim}5^{\circ}C$), and PAG oil concentration($0{\sim}5\;wt%$). The variation of the heat transfer coefficient was different in accordance with the oil concentration. With the increase of the oil concentration, the evaporation heat transfer coefficient decreased and the delay of dryout by oil addition was found. Pressure drop increased with the increase of the oil concentration and heat flux, and the decrease of saturation temperature.

Effects of Sandalwood Essential Oil on the iNOS Expression and Proinflammatory Cytokine Production (Sandalwood Essential Oil의 iNOS 발현과 염증성사이토카인의 생성에 미치는 영향)

  • Park, Jeoung-Suk;Jung, Sook-Heui
    • YAKHAK HOEJI
    • /
    • v.57 no.1
    • /
    • pp.70-75
    • /
    • 2013
  • The present study was designed to determine the effect of the Sandalwood Essential Oil (Santalum album) on pro-inflammatory factors such as NO, iNOS expression and IL-$1{\beta}$, IL-6, TNF-${\alpha}$ in lipopolysaccharide (LPS) - stimulated RAW264.7 macrophages cells. The cell toxicity was determined by MTS assay. To evaluate of anti-inflammatory effect of Sandalwood Essential Oil, amount of NO was measured using the NO detection kit and the iNOS expression was measured by western blot analysis and reverse transcriptase polymerase chain reaction (RT-PCR). And proinflammatory cytokines were measured by ELISA kit. As a result, Sandalwood Essential Oil reduced NO, iNOS expression and IL-$1{\beta}$, IL-6, TNF-${\alpha}$ production without cytotoxicity. Our results suggest that the Sandalwood Essential Oil may have an anti-inflammatory property through suppressing inflammatory mediator productions and appears to be useful as an anti-inflammatory oil.

Forced Convective Boiling of Refrigerant-Oil Mixtures in a Bundle of Enhanced Tubes Having Pores and Connecting Gaps

  • Park, Ji-Hoon;Kim, Nae-Hyun;Kim, Do-Young;Byun, Ho-Won;Choi, Yong-Min;Kim, Soo-Hwan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.17 no.3
    • /
    • pp.81-87
    • /
    • 2009
  • The effect of oil on convective boiling of R-123 in an enhanced tube bundle is experimentally investigated at $26.7^{\circ}C$ saturation temperature. The enhanced tube had pores (0.23 mm diameter) and connecting gaps (0.07 mm width), which had been optimized using pure R-123. The effects of oil concentration (0 to 5%), heat flux (10 to $40\;kW/m^2$), mass velocity (8 to $26\;kg/m2^s$) and vapor quality are investigated. The oil significantly reduces the bundle boiling heat transfer coefficient. With 1% oil, the reduction is approximately 35%. Further addition of oil further reduces the heat transfer coefficient. The data are also compared with the pool boiling counterpart. The reduction in the heat transfer coefficient is smaller in a bundle (convective boiling) than in a pool (single-tube pool boiling), with larger difference at a smaller heat flux. Similar to pure R-123 case, the effects of mass velocity and vapor quality are negligible for the convective boiling of R-123/oil mixture.