• Title/Summary/Keyword: OH

Search Result 66,807, Processing Time 0.086 seconds

The Plan of Dose Reduction by Measuring and Evaluating Occupationally Exposed Dose in vivo Tests of Nuclear Medicine (핵의학 체내검사 업무 단계 별 피폭선량 측정 및 분석을 통한 피폭선량 감소 방안)

  • Kil, Sang-Hyeong;Lim, Yeong-Hyeon;Park, Kwang-Youl;Jo, Kyung-Nam;Kim, Jung-Hun;Oh, Ji-Eun;Lee, Sang-Hyup;Lee, Su-Jung;Jun, Ji-Tak;Jung, Eui-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.26-32
    • /
    • 2010
  • Purpose: It is to find the way to minimize occupationally exposed dose for workers in vivo tests in each working stage within the range of the working environment which does not ruin the examination and the performance efficiency. Materials and Methods: The process of the nuclear tests in vivo using a radioactive isotope consists of radioisotope distribution, a radioisotope injection ($^{99m}Tc$, $^{18}F$-FDG), and scanning and guiding patients. Using a measuring instrument of RadEye-G10 gamma survey meter (Thermo SCIENTIFIC), the exposure doses in each working stage are measured and evaluated. Before the radioisotope injection the patients are explained about the examination and educated about matters that require attention. It is to reduce the meeting time with the patients. In addition, workers are also educated about the outside exposure and have to put on the protected devices. When the radioisotope is injected to the patients the exposure doses are measured due to whether they are in the protected devices or not. It is also measured due to whether there are the explanation about the examination and the education about matters that require attention or not. The total exposure dose is visualized into the graph in using Microsoft office excel 2007. The difference of this doses are analyzed by wilcoxon signed ranks test in using SPSS (statistical package for the social science) program 12.0. In this case of p<0.01, this study is reliable in the statistics. Results: It was reliable in the statistics that the exposure dose of injecting $^{99m}Tc$-DPD 20 mCi in wearing the protected devices showed 88% smaller than the dose of injecting it without the protected devices. However, it was not reliable in the statistics that the exposure dose of injecting $^{18}F$-FDG 10 mCi with wearing protected devices had 26% decrease than without them. Training before injecting $^{99m}Tc$-DPD 20 mCi to patient made the exposure dose drop to 63% comparing with training after the injection. The dose of training before injecting $^{18}F$-FDG 10 mCi had 52% less then the training after the injection. Both of them were reliable in the statistics. Conclusion: In the examination of using the radioisotope $^{99m}Tc$, wearing the protected devices are more effective to reduce the exposure dose than without wearing them. In the case of using $^{18}F$-FDG, reducing meeting time with patients is more effective to drop the exposure dose. Therefore if we try to protect workers from radioactivity according to each radioisotope characteristic it could be more effective and active radiation shield from radioactivity.

  • PDF

The Comparison of Image Quality and Quantitative Indices by Wide Beam Reconstruction Method and Filtered Back Projection Method in Tl-201 Myocardial Perfusion SPECT (Tl-201 심근관류 SPECT 검사에서 광대역 재구성(Wide Beam Reconstruction: WBR) 방법과 여과 후 역투영법에 따른 영상의 질 및 정량적 지표 값 비교)

  • Yoon, Soon-Sang;Nam, Ki-Pyo;Shim, Dong-Oh;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.122-127
    • /
    • 2010
  • Purpose: The Xpress3.$cardiac^{TM}$ which is a kind of wide beam reconstruction (WBR) method developed by UltraSPECT (Haifa, Israel) enables the acquisition of at quarter time while maintaining image quality. The purpose of this study is to investigate the usefulness of WBR method for decreasing scan times and to compare to it with filtered back projection (FBP), which is the method routinely used. Materials and Methods: Phantom and clinical studies were performed. The anthropomorphic torso phantom was made on an equality with counts from patient's body. The Tl-201 concentrations in the compartments were 74 kBq (2 ${\mu}Ci$)/cc in myocardium, 11.1 kBq (0.3 ${\mu}Ci$)/cc in soft tissue, and 2.59 kBq (0.07 ${\mu}Ci$)/cc in lung. The non-gated Tl-201 myocardial perfusion SPECT data were acquired with the phantom. The former study was scanned for 50 seconds per frame with FBP method, and the latter study was acquired for 13 seconds per frame with WBR method. Using the Xeleris ver. 2.0551, full width at half maximum (FWHM) and average image contrast were compared. In clinical studies, we analyzed the 30 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Medical Center from January to April 2010. The patients were imaged at full time (50 second per frame) with FBP algorithm and again quarter-time (13 second per frame) with the WBR algorithm. Using the 4D MSPECT (4DM), Quantitative Perfusion SPECT (QPS), and Quantitative Gated SPECT (QGS) software, the summed stress score (SSS), summed rest score (SRS), summed difference score, end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were analyzed for their correlations and statistical comparison by paired t-test. Results: As a result of the phantom study, the WBR method improved FWHM more than about 30% compared with FBP method (WBR data 5.47 mm, FBP data 7.07 mm). And the WBR method's average image contrast was also higher than FBP method's. However, in result of quantitative indices, SSS, SDS, SRS, EDV, ESV, EF, there were statistically significant differences from WBR and FBP(p<0.01). In the correlation of SSS, SDS, SRS, there were significant differences for WBR and FBP (0.18, 0.34, 0.08). But EDV, ESV, EF showed good correlation with WBR and FBP (0.88, 0.89, 0.71). Conclusion: From phantom study results, we confirmed that the WBR method reduces an acquisition time while improving an image quality compared with FBP method. However, we should consider significant differences in quantitative indices. And it needs to take an evaluation test to apply clinical study to find a cause of differences out between phantom and clinical results.

  • PDF

The Quantitative Assessment of Renal Function and Size by Differences of Acquisition Counts in $^{99m}Tc$-DMSA Renal Scan ($^{99m}Tc$-DMSA 신장검사에서 획득 계수의 차이에 따른 기능 및 형태 평가)

  • Shim, Dong-Oh;Kim, Ho-Sung;Chung, Eun-Mi
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.117-121
    • /
    • 2010
  • Purpose: In nuclear medicine study, there are two methods, preset count method and preset time method, to acquire static images. We usually use preset count method for static image in $^{99m}Tc$-DMSA renal scan, but occasionally use preset time method. In case of using preset count method, we always acquire same counts but it causes a difference of scan time. In case of using preset time method, it takes same scan time to acquire images but it causes different counts. Therefore, the purpose of this study is to investigate any differences of function and formal information in both kidney by acquisition counts Materials and Methods: From January 11, 2010 to March 31, 2010, we analyzed the 30 patients (M: 11, W: 19). who were examined by $^{99m}Tc$-DMSA scan and have one side of functioning kidney relatively between 40~60%. And the patients who have cold and hot region in image were analyzed but we did not accept images of patients when it was hard to divide kidney into cortex. There was no division between subjects and age of subjects is $14.83{\pm}22.07$ old. We used the BrightView gamma camera from PHILIPS. To analyze function and formal of kidney, we used JET stream release 3.0 version from PHILIPS. Using SPSS 12.0 program, we compared descriptive statistics and paired T-test. Images were acquired sequentially in the same parameters, but there are three methods which different from acquisition time and scan time, 100 kcounts, 300 kcounts and 7 minutes method (exceed 300 kcounts). To assess function and formal information of kidney, we measured renal relative function, geometric mean and size of kidney and analyzed each difference. Results: In case of renal relative function in both kidney, 100 kcounts method was $50.52{\pm}3.64%$. 300 kcounts method was $50.38{\pm}3.66%$ and 7 minutes method was $49.91{\pm}3.40%$ and there were no statistical significant differences between each method. In case of geometric mean, 100 kcounts method was $50.08{\pm}3.25%$. 300 kcounts method was $49.89{\pm}3.40%$ and 7 minutes method was $49.91{\pm}3.24%$. And also, there were no statistical significant differences. When comparing size of kidney, 100 kcounts method was $8.23{\pm}1.96$ cm. 300 kcounts method was $8.12{\pm}1.90$ cm and 7 minutes method was $8.35{\pm}1.97$ cm. In case of right kidney, 100 kcounts method was $7.91{\pm}1.88$ cm. 300 kcounts method was $8.12{\pm}1.90$ cm and 7 minutes method was $8.25{\pm}1.96$ cm. From those values, we recognized that there were significant differences each method (p<0.05). Conclusion: From results of this study, there were no statistical differences in renal relative function and geometric mean by acquisition counts. However, in shape of kidney, the more acquisition counts are increasing, the more size of kidney is getting big. And there were statistical significant differences. Therefore, to perform reliable quantitative result, preset count method is more desirable than preset time method. Especially, in case of a follow-up test, if we use preset time method, it will cause differences of formal results in kidney due to acquisition counts each time we examine patients.

  • PDF

A Study to Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET/CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Cho, Seok-Won;Park, Hoon-Hee;Kim, Jung-Yul;Ban, Yung-Kak;Lim, Han-Sang;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.159-165
    • /
    • 2010
  • Purpose: Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to $^{99m}Tc$ emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radiotechnologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radiotechnologists. Materials and Methods: Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8$ cm and mean weight: $65.9{\pm}1.4$ kg). Radiation were measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150 and 200 cm. Then, all the procedure was given with a portable radiation shielding on the location of head, chest and abdomen at the distance of 100, 150 and 200 cm and transmittance was calculated. Results: In 10 cm, head (105.40 ${\mu}Sv/h$) was the highest and foot (15.85 ${\mu}Sv/h$) was the lowest. In 200 cm, head, chest and abdomen showed similar. On head, the measured dose rates were 9.56 ${\mu}Sv/h$, 5.23 ${\mu}Sv/h$, and 3.40 ${\mu}Sv/h$ in 100, 150 and 200 cm respectively. When using shielder, it shows 2.24 ${\mu}Sv/h$, 1.67 ${\mu}Sv/h$, and 1.27 ${\mu}Sv/h$ in 100, 150 and 200 cm on head. On chest, the measured dose rates were 8.54 ${\mu}Sv/h$, 4.90 ${\mu}Sv/h$, 3.44 ${\mu}Sv/h$ in 100, 150 and 200 cm, respectively. When using shielder, it shows 2.27 ${\mu}Sv/h$, 1.34 ${\mu}Sv/h$, and 1.13 ${\mu}Sv/h$ in 100, 150 and 200 cm on chest. On abdomen, the measured dose rates were 9.83 ${\mu}Sv/h$, 5.15 ${\mu}Sv/h$ and 3.18 ${\mu}Sv/h$ in 100, 150 and 200cm respectively. When using shielder, it shows 2.60 ${\mu}Sv/h$, 1.75 ${\mu}Sv/h$ and 1.23 ${\mu}Sv/h$ in 100, 150 and 200 cm on abdomen. Transmittance was increased as the distance was expanded. Conclusion: As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the radiotechnologists.

  • PDF

Dosimetric Characteristics of Detectors in Measurement of Beam Data for Small Fields of Linear Accelerator (선형가속기의 소조사면에 대한 빔 자료 측정에서 검출기의 선량 특성 분석)

  • Koo, Ki-Lae;Yang, Oh-Nam;Lim, Cheong-Hwan;Choi, Won-Sik;Shin, Seong-Soo;Ahn, Woo-Sang
    • Journal of radiological science and technology
    • /
    • v.35 no.3
    • /
    • pp.265-273
    • /
    • 2012
  • Aquisition of accurate beam data is very important to calculate a reliable dose distribution of the treatment planning system for small radiation fields in intensity-modulated radiation therapy(IMRT) and stereotactic radiosurgery(SRS). For the measurement of small fields, the choice of a suitable detector is important due to the shape gradient in profile penumbra, the lack of lateral electronic equilibrium, and the effect of effective detector volume. Therefore, this study was to analyze the dosimetric characteristics of various detectors in measurement of beam data for small fields of linear accelerator. 0.01cc and 0.13cc ion chambers (CC01 and CC13) and a stereotactic diode detector(SFD) were used for measurement of small fields. The beam data, including the percent depth dose, output factor, and beam profile were acquired under 6 MV and 15 MV photon beams. Measurements were performed with the field size ranging from $2{\times}2cm^2$ to $5{\times}5cm^2$. For $2{\times}2cm^2$ field size, the differences of the ratios of $PDD_{20}$ and $PDD_{10}$ measured by CC01 and SFD detectors were 1.02% and 0.12% for 6 MV and 15 MV photon beams, respectively. For field sizes larger than $3{\times}3cm^2$, the differences of values of $PDD_{20}/PDD_{10}$ obtained from each detector were 1.15% and 0.71% for 6 MV and 15 MV photon beams, respectively. The output factors obtained from CC01 and SFD for $2{\times}2cm^2$ field size were within 0.5% and 1.5% for 6 MV and 15 MV, respectively. The differences in output factor of three detectors for $3{\times}3cm^2$ to $5{\times}5cm^2$ field sizes were within 0.5%. Profile penumbras measured by the SFD, CC01, and CC13 detectors at three depths were average 2.7 mm and 3.5 mm, 3.4 mm and 4.3 mm, and 5.2 mm and 6.1 mm for 6 MV and 15 MV photon beams, respectively. In conclusion, it could be possible to use of the CC01 and SFD detectors for the measurement of percent depth dose and output factor for $2{\times}2cm^2$ field size, and to use of three detectors for $3{\times}3cm^2$ to $5{\times}5cm^2$ field sizes. CC01 and SFD detectors, consider ably smaller than the radiation field, should be used in order to accurately measure the profile penumbra for small field sizes.

The 1998, 1999 Patterns of Care Study for Breast Irradiation after Mastectomy in Korea (1998, 1999년도 우리나라에서 시행된 근치적 유방 전절제술 후 방사선치료 현황 조사)

  • Keum,, Ki-Chang;Shim, Su-Jung;Lee, Ik-Jae;Park, Won;Lee, Sang-Wook;Shin, Hyun-Soo;Chung, Eun-Ji;Chie, Eui-Kyu;Kim, Il-Han;Oh, Do-Hoon;Ha, Sung-Whan;Lee, Hyung-Sik;Ahn, Sung-Ja
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.7-15
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: To determine the patterns of evaluation and treatment in patients with breast cancer after mastectomy and treated with radiotherapy. A nationwide study was performed with the goal of improving radiotherapy treatment. $\underline{Materials\;and\;Methods}$: A web- based database system for the Korean Patterns of Care Study (PCS) for 6 common cancers was developed. Randomly selected records of 286 eligible patients treated between 1998 and 1999 from 17 hospitals were reviewed. $\underline{Results}$: The ages of the study patients ranged from 20 to 80 years (median age 44 years). The pathologic T stage by the AJCC was T1 in 9.7% of the cases, T2 in 59.2% of the cases, T3 in 25.6% of the cases, and T4 in 5.3% of the cases. For analysis of nodal involvement, N0 was 7.3%, N1 was 14%, N2 was 38.8%, and N3 was 38.5% of the cases. The AJCC stage was stage I in 0.7% of the cases, stage IIa in 3.8% of the cases, stage IIb in 9.8% of the cases, stage IIIa in 43% of the cases, stage IIIb in 2.8% of the cases, and IIIc in 38.5% of the cases. There were various sequences of chemotherapy and radiotherapy after mastectomy. Mastectomy and chemotherapy followed by radiotherapy was the most commonly performed sequence in 47% of the cases. Mastectomy, chemotherapy, and radiotherapy followed by additional chemotherapy was performed in 35% of the cases, and neoadjuvant chemoradiotherapy was performed in 12.5% of the cases. The radiotherapy volume was chest wall only in 5.6% of the cases. The volume was chest wall and supraclavicular fossa (SCL) in 20.3% of the cases; chest wall, SCL and internal mammary lymph node (IMN) in 27.6% of the cases; chest wall, SCL and posterior axillary lymph node in 25.9% of the cases; chest wall, SCL, IMN, and posterior axillary lymph node in 19.9% of the cases. Two patients received IMN only. The method of chest wall irradiation was tangential field in 57.3% of the cases and electron beam in 42% of the cases. A bolus for the chest wall was used in 54.8% of the tangential field cases and 52.5% of the electron beam cases. The radiation dose to the chest wall was $45{\sim}59.4\;Gy$ (median 50.4 Gy), to the SCL was $45{\sim}59.4\;Gy$ (median 50.4 Gy), and to the PAB was $4.8{\sim}38.8\;Gy$, (median 9 Gy) $\underline{Conclusion}$: Different and various treatment methods were used for radiotherapy of the breast cancer patients after mastectomy in each hospital. Most of treatment methods varied in the irradiation of the chest wall. A separate analysis for the details of radiotherapy planning also needs to be followed and the outcome of treatment is needed in order to evaluate the different processes.

Antagonistic Interaction between Quinclorac and Bensulfuron-methyl on Growth of the Rice Plants (Quinclorac과 Bensulfuron-methyl의 혼합처리(混合處理)에서 벼의 생장(生長)에 대한 제초제간(除草劑間) 길항작용(拮抗作用))

  • Kwon, Oh-Yeon;Kwon, Yong-Woong
    • Korean Journal of Weed Science
    • /
    • v.17 no.3
    • /
    • pp.288-294
    • /
    • 1997
  • Field and pot expeiments were carried out to evaluate the interaction between quinclorac and bensulfuron-methyl on growth of the rice plants(Oryza sativa L. cv. Choocheongbyeo) at 20, 45, 65 days-old stages. Quinclorac and bensulfuron-methyl showed antagonistic interaction at both stages, which were detected by the Chisaka's method at isobles of 10% growth inhibition. The antagonism indices were -0.63 and -1.67 at 20 and 65 days-old seedling stages, respectively. Leaf-rolling of rice occurred when quinclorac was applied at 600g ai/ha or more at 20 days-old seedling stage, while it occured at the dose of 900g ai/ha at 65 days-old stage. Bensulfuron-methyl reduced plant height and dry weight as well as tiller production at both stages. Leaf-rolling of rice was reduced when mixture of quinclorac and bensulfuron-methyl was applied due to antagonism of the two herbicides. High temperatures increased the phytotoxicity of bensulfuron-methyl, while the phytotoxicity caused by quinclorac alone was not responsive to temperature. The antagonistic effect between quinclorac and bensulfuron-methyl increased at low temperature as tested by the Colby's method.

  • PDF

Immediate Reoperation for Failed Mitral Valve Repair (승모판막성형술 실패 직후에 시행한 재수술)

  • Baek, Man-Jong;Na, Chan-Young;Oh, Sam-Se;Kim, Woong-Han;Whang, Sung-Wook;Lee, Cheol;Chang, Yun-Hee;Jo, Won-Min;Kim, Jae-Hyun;Seo, Hong-Ju;Kim, Wook-Sung;Lee, Young-Tak;Park, Young-Kwan;Kim, Chong-Whan
    • Journal of Chest Surgery
    • /
    • v.36 no.12
    • /
    • pp.929-936
    • /
    • 2003
  • We analysed the surgical outcomes of immediate reoperations after mitral valve repair. Material and Method: Eighteen patients who underwent immediate reoperation for failed mitral valve repair from April 1995 through July 2001 were reviewed retrospectively. There were 13 female patients. The mitral valve disease was regurgitation (MR) in 12 patients, stenosis (MS) in 3, and mixed lesion in 3. The etiologies of the valve disease were rheumatic in 9 patients, degenerative in 8, and endocarditis in 1. The causes of reoperation was residual MR in 13 patients, residual MS in 4, and rupture of left ventricle in 1. Fourteen patients had rerepair for residual mitral lesions (77.8%) and four underwent replacement. Result: There was no early death. After mean follow-vp of 33 months, there was one late death. Echocardiography revealed no or grade 1 of MR (64.3%) in 9 patients and no or mild MS in 11 patients (78,6%). Reoperation was done in one patient. The cumulative survival and freedom from valve-related reoperation at 6 years were 94% and 90%, respectively. The cumulative freedom from recurrent MR and MS at 4 years were 56% and 44%, respectively. Conclusion: This study suggests that immediate reoperation for failed mitral valve repair offers good early and intermediate survival, and mitral valve rerepair can be successfully performed in most of patients. However, because mitral rerepair have high failure rate, especially in rheumatic valve disease, adequate selections of valvuloplasty technique and indication are important to reduce the failure rate of mitral rerepair.

Adsorption of Arsenic onto Two-Line Ferrihydrite (비소의 Two-Line Ferrihydrite에 대한 흡착반응)

  • Jung, Young-Il;Lee, Woo-Chun;Cho, Hyen-Goo;Yun, Seong-Taek;Kim, Soon-Oh
    • Journal of the Mineralogical Society of Korea
    • /
    • v.21 no.3
    • /
    • pp.227-237
    • /
    • 2008
  • Arsenic has recently become of the most serious environmental concerns, and the worldwide regulation of arsenic fur drinking water has been reinforced. Arsenic contaminated groundwater and soil have been frequently revealed as well, and arsenic contamination and its treatment and measures have been domestically raised as one of the most important environmental issues. Arsenic behavior in geo-environment is principally affected by oxides and clay minerals, and particularly iron (oxy)hydroxides have been well known to be most effective in controlling arsenic. Among a number of iron (oxy)hydroxides, for this reason, 2-line ferrihydrite was selected in this study to investigate its effect on arsenic behavior. Adsorption of 2-line ferrihydrite was characterized and compared between As(III) and As(V) which are known to be the most ubiquitous species among arsenic forms in natural environment. Two-line ferrihydrite synthesized in the lab as the adsorbent of arsenic had $10\sim200$ nm for diameter, $247m^{2}/g$ for specific surface area, and 8.2 for pH of zero charge, and those representative properties of 2-line ferrihydrite appeared to be greatly suitable to be used as adsorbent of arsenic. The experimental results on equilibrium adsorption indicate that As(III) showed much stronger adsorption affinity onto 2-line ferrihydrite than As(V). In addition, the maximum adsorptions of As(III) and As(V) were observed at pH 7.0 and 2.0, respectively. In particular, the adsorption of As(III) did not show any difference between pH conditions, except for pH 12.2. On the contrary, the As(V) adsorption was remarkably decreased with increase in pH. The results obtained from the detailed experiments investigating pH effect on arsenic adsorption show that As(III) adsorption increased up to pH 8.0 and dramatically decreased above pH 9.2. In case of As(V), its adsorption steadily decreased with increase in pH. The reason the adsorption characteristics became totally different depending on arsenic species is attributed to the fact that chemical speciation of arsenic and surface charge of 2-line ferrihydrite are significantly affected by pH, and it is speculated that those composite phenomena cause the difference in adsorption between As(III) and As(V). From the view point of adsorption kinetics, adsorption of arsenic species onto 2-line ferrihydrite was investigated to be mostly completed within the duration of 2 hours. Among the kinetic models proposed so for, power function and elovich model were evaluated to be the most suitable ones which can simulate adsorption kinetics of two kinds of arsenic species onto 2-line ferrihydrite.

Measuring Intracellular Mycobacterial Killing Using a Human Whole Blood Assay (인체 전혈 모델을 이용한 세포내 결핵균 살균력에 관한 연구)

  • Cheon, Seon-Hee;Song, Ho-Yeon;Lee, Eun-Hee;Oh, Hee-Jung;Kang, In-Sook;Cho, Ji-Yoon;Hong, Young-Sun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.5
    • /
    • pp.497-509
    • /
    • 2002
  • Background : The mechanisms through which cellular activation results in intracellular mycobacterial killing is only partially understood. However, in vitro studies of human immunity to Mycobacterium tuberculosis have been largely modeled on the work reported by Crowle, which is complicated by several factors. The whole blood culture is simple and allows the simultaneous analysis of the relationship between bacterial killing and the effect of effector cells and humoral factors. In this study, we attempted to determine the extent to which M. tuberculosis is killed in a human whole blood culture and to explore the role of the host and microbial factor in this process. Methods : The PPD positive subject were compared to the umbilical cord blood and patients with tuberculosis, diabetes and lung cancer. The culture is performed using heparinized whole blood diluted with a culture medium and infected with a low number of M. avium or M. tuberculosis $H_{37}Ra$ for 4 days by rotating the culture in a $37^{\circ}C$, 5% $CO_2$ incubator. In some experiments, methlprednisolone- or pentoxifyline were used to inhibit the immune response. To assess the role of the T-cell subsets, CD4+, CD8+ T-cells or both were removed from the blood using magnetic beads. The ${\Delta}$ log killing ratio was defined using a CFU assay as the difference in the log number of viable organisms in the completed culture compared to the inoculum. Results : 1. A trend was noted toward the improved killing of mycobacteria in PPD+ subjects comparing to the umbilical cord blood but there was no specific difference in the patients with tuberculosis, diabetes and lung cancer. 2. Methylprednisolone and pentoxifyline adversely affected the killing in the PPD+ subjects umbilical cord blood and patients with tuberculosis. 3. The deletion of CD4+ or CD8+ T-lymphocytes adversely affected the killing of M. avium and M. tuberculosis $H_{37}Ra$ by PPD+ subjects. Deletion of both cell types had an additive effect, particularly in M. tuberculosis $H_{37}Ra$. 4. A significantly improved mycobacterial killing was noted after chemotherapy in patients with tuberculosis and the ${\Delta}$ logKR continuously decreased in a 3 and 4 days of whole blood culture. Conclusion : The in vitro bactericidal assay by human whole blood culture model was settled using a CFU assay. However, the host immunity to M. tuberculosis was not apparent in the human whole blood culture bactericidal assay, and patients with tuberculosis showed markedly improved bacterial killing after anti-tuberculous chemotherapy compared to before. The simplicity of a whole blood culture facilitates its inclusion in a clinical trial and it may have a potential role as a surrogate marker in a TB vaccine trial.