• Title/Summary/Keyword: OFF cell

Search Result 716, Processing Time 0.033 seconds

Distributed BS Transmit Power Control for Utility Maximization in Small-Cell Networks (소형 셀 환경에서 유틸리티 최대화를 위한 분산화된 방법의 기지국 전송 전력 제어)

  • Lee, Changsik;Kim, Jihwan;Kwak, Jeongho;Kim, Eunkyung;Chong, Song
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.12
    • /
    • pp.1125-1134
    • /
    • 2013
  • Small cells such as pico or femto cells are promising as a solution to cope with higher traffic explosion and the large number of users. However, the users within small cells are likely to suffer severe inter-cell interference (ICI) from neighboring base stations (BSs). To tackle this, several papers suggest BS transmit power on/off control algorithms which increase edge user throughput. However, these algorithms require centralized coordinator and have high computational complexity. This paper makes a contribution towards presenting fully distributed and low complex joint BS on/off control and user scheduling algorithm (FDA) by selecting on/off pattern of BSs. Throughput the extensive simulations, we verify the performance of our algorithm as follows: (i) Our FDA provides better throughput performance of cell edge users by 170% than the algorithm without the ICI management. (ii) Our FDA catches up with the performance of optimal algorithm by 88-96% in geometric average throughput and sufficiently small gap in edge user throughput.

The Effects of Peroxiredoxin III on Human HeLa Cell Proliferation

  • Choi, Soonyoung;Kang, Sangwon
    • IMMUNE NETWORK
    • /
    • v.3 no.4
    • /
    • pp.276-280
    • /
    • 2003
  • Background: Peroxidases (Prx) of the peroxiredoxin family reduce hydrogen peroxide and alkyl hydroperoxides to water and alcohol respectively. Hydrogen peroxide is implicated as an intracellular messenger in various cellular responses such as proliferation and differentiation. And Prx I activity is regulated by Cdc-2 mediated phosphorylation. This work was undertaken to investigate the proliferation role of peroxiredoxin III as a member of Prx family in Prx III overexpressed HeLa cell line. Methods: To provide further evidence of proliferation, we selected Prx III stably expressed HeLa Tet-off cell lines. Cell proliferation was examined by using proliferation reagent WST-1 in the presence or absence of doxycycline. Prx III, 2-cys Prx enzymes exist as homodimer. The activation of Prx III heterodimer with induced and endogenous Prx III was examined by immunoprecipitation. Results: Immunoprecipitation analysis of the induced and endogenous Prx III with anti-myc showed that the induced wild type (WT) and dominant negative (DN) Prx III from HeLa Prx III Tet-off stable cell heterodimerized with endogenous Prx III each other. And the expression level of induced Prx III was examined after addition of doxycycline. By 72 hr, the expression level of induced Prx III was diminished gradually and the half-life of the induced wild type Prx III was approximately 17 hr. The proliferation experiment demonstrated that the relative proliferation value of induced and endogenous WT Prx III stable cell has no changes but the DN Prx III induced HeLa Tet-off stable cells were lower than endogenous Prx III. Conclusion: In conclusion, the HeLa dominant negative Prx III Tet-off stable cells were decreased the proliferation.

Traffic Modeling and Call Admission Control GCRA-Controlled VBR Traffic in ATM Network (ATM 망에서 UPC 파라미터로 제어된 VBR 트래픽 모델링 및 호 수락 제어)

  • 정승욱;정수환
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.7C
    • /
    • pp.670-676
    • /
    • 2002
  • The object of ATM network is to the guarantee quality of service(QoS). Therefore, various of traffic management schemes have been proposed. Among these schemes, call admission control(CAC) is very important to provide real-time services and ON-OFF model, which is single source traffic model, has been used. But ON-OFF model differ from GCRA(Generic Cell Rate Algorithm) controlled traffic in ATM network. In this paper, we analyze the traffic, which is controlled as dual GCRA, and propose TWM(Three-state Worst-case Model), which is new single source traffic model. We also proposed CAC to guarantee peak-to-peak CDV(Cell Delay Variation) based on the TWM. In experiments, ON-OFF model and TWM are compared to show that TWM is superior to ON-Off model in terms of QoS guaranteeing.

LOS/LOC Scan Test Techniques for Detection of Delay Faults (지연고장 검출을 위한 LOS/LOC 스캔 테스트 기술)

  • Hur, Yongmin;Choe, Youngcheol
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.4
    • /
    • pp.219-225
    • /
    • 2014
  • The New efficient Mux-based scan latch cell design and scan test of LOS/LOC modes are proposed for detection of delay faults in digital logic circuits. The proposed scan cell design can support LOS(Launch-off-Shift) and LOC(Launch-off-Capture) tests with high fault coverage and low scan power and it can alleviate the problem of the slow selector enable signal and hold signal by supporting the logic capable of switching at the operational clock speeds. Also, it efficiently controls the power dissipation of the scan cell design during scan testing. Functional operation and timing simulation waveform for proposed scan hold cell design shows improvement in at-speed test timing in both test modes.

The Ejector Design and Test for 5kW Molten Carbonate Fuel Cell (5kW 용융탄산염 연료전지 이젝터 설계 및 시험)

  • Kim, Beom-Joo;Kim, Do-Hyung;Lee, Jung-Hyun;Jung, Sang-Chun;Lee, Sung-Yoon;Kang, Seung-Won;Lim, Hee-Chun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.53-56
    • /
    • 2008
  • An ejector is a fluid machinery to be utilized for mixing fluids, maintaining vacuum, and transporting them. The Ejector is applied for a variety of industrial fields such as refrigerators and power plants. It is adopted to recycle anode off gas safely in 5kW Molten Carbonate Fuel Cell system of KEPRI(Korea Electric Power Research Institute). The ejector is placed at mixing point between the anode off gas and the cathode off gas or the fresh air. In this study, the entrainment ratio is measured according to the diametrical ratio of nozzle to throat. In addition, the performance curve of the ejector and the differential pressure in diffuser is observed.

  • PDF

Performance Analysis of the Multiplexer for Shaped Video Traffic Sources (쉐이퍼를 사용한 비디오 트래픽원의 다중화기 성능 분석)

  • Lee, S.C.;Hong, J.W.;Kim, C.S.
    • IE interfaces
    • /
    • v.18 no.4
    • /
    • pp.494-503
    • /
    • 2005
  • This paper considers the problem of performance analysis for the multiplexer, when homogeneous periodic on-off sources are statistically multiplexed. Periodic on-off source model is defined that on-period and off-period are repeated by once in a deterministic periodic time and in on-period, cell arrives with deterministic time interval. In order to reflect periodicity of source model, we consider two multiplexing situation, such as random multiplexing and synchronized multiplexing. In both case, we obtain the overload-period distribution in the multiplexer, and an approximate method using the overload period distribution is suggested for obtaining the CLP(Cell Loss Probability) in the buffer of the multiplexer. A numerical example using MPEG-I real traffic samples and the results are also presented.

Three-Terminal Hybrid-aligned Nematic Liquid Crystal Cell for Fast Turn-off Switching

  • Baek, Jong-In;Kim, Ki-Han;Kim, Jae-Chang;Yoon, Tae-Hoon
    • Journal of Information Display
    • /
    • v.10 no.1
    • /
    • pp.16-18
    • /
    • 2009
  • A three-terminal hybrid-aligned nematic liquid crystal (3T-HAN LC) cell capable of fast turn-off switching is proposed in this paper. By employing the relaxation process initiated by an electric-field pulse, a fast turn-off time of less than 1 ms can be obtained through optically hidden relaxation. A low operating voltage and high transmittance were confirmed through simulations and experiments.

Hybrid Method to Compute the Cell Loss Probability in a Multiplexer with the Superposition of Heterogeneous ON/OFF Sources (이질적 ON/OFF 원을 입력으로 한 다중화 장치의 셀 손실률 계산을 위한 하이브리드 방법)

  • Hong, Jung-Sik;Kim, Sang-Baik
    • IE interfaces
    • /
    • v.12 no.2
    • /
    • pp.312-318
    • /
    • 1999
  • This paper considers the cell loss probability(CLP) in a multiplexer with the superposition of heterogeneous ON/OFF sources. The input traffic is composed of k classes. Traffic of class i is the superposition of M_(i) ON/OFF sources. Recently, the method based on the Markov modulated deterministic process(MMDP) is presented. Basically, it is the discretized model of stochastic fluid flow process(SFFP) and gives the CLP very fast, but under-estimates the CLP especially when the value of estimated CLP is very low. This paper develops the discretized model of Markov modulated Poisson process(MMPP). It is a special type of switched batch Bernoulli process(SBBP). Combining the transition probability matrix of MMDP and SBBP according to the state which is characterized by the arrival rate, this paper presents hybrid algorithm. The hybrid algorithm gives better estimate of CLP than that of MMDP and faster than SBBP.

  • PDF

Numerical Design of Light-off Auto-Catalyst for Reducing Cold-Start Emissions (냉간시동시 자동차용 저온활성촉매의 성능 향상을 위한 수치적 설계)

  • Jeong, Soo-Jin;Kim, Woo-Seung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.9
    • /
    • pp.1264-1276
    • /
    • 2000
  • Light-off catalyst has been used for minimization of cold-start emissions. Improved cold-start performance of light-off catalyst needs the optimal design in terms of flow distribution, geometric surface area, precious metal loading, cell density and space velocity. In this study, these influential factors are numerically investigated using integrated numerical technique by considering not only 3-D fluid flow but also heat and mass transfer with chemical reactions. The present results indicate that uneven catalyst loading of depositing high active catalyst at upstream of monolith is beneficial during warm-up period but its effect is severely deteriorated when the space velocity is above 100,000 $hr^{-1}$ To maximize light-off performance, this study suggests that 1) a light-off catalyst be designed double substrate type; 2) the substrate with high GSA and high PM loading at face be placed at the front monolith; and 3) the cell density of the rear monolith be lower to reduce the pressure drop.