• Title/Summary/Keyword: OF Cable

Search Result 4,703, Processing Time 0.043 seconds

A study result on coordinative protection method of HTS cable implemented distribution system (초전도케이블이 병입된 계통의 고장에 대한 보호협조 검토기법)

  • Lee, Hyun-Chul;Yang, Byeong-Mo;Lee, Geun-Joon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.700-704
    • /
    • 2011
  • This paper proposes a coordinative protection study results of 22.9kV HTS(High-Temperature Superconducting) cable implemented distribution system. HTS cable can provide about 5 times larger transfer capacability compare to conventional XLPE cable, however, it has different heat characteristic so called quench. This paper presents the simulation results on Ichun substation HTS cable which connects main transformer and 22.9kV bus. Various expected fault cases are considered and discussed to examine whether conventional protection scheme is effective to protect both of existing facilities and HTS cable. With the results of simulation, conventional protection scheme can be used if instantaneous element and time inverse elements could be adjusted with proper time coordination. Internal temperatures of HTS cable conductor in safe region with proper protection without quench. This results are to be demonstrated by the field test and will be implemented in Ichon substation HTS cable protection and control system.

Development of a Guiding System for the High-Speed Self-Align Cable Winding (고속 자동정렬 케이블 와인딩을 위한 가이딩 시스템 개발)

  • 이창우;강현규;신기현
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.7
    • /
    • pp.124-129
    • /
    • 2004
  • Recently, the demand for the optical cable is rapidly growing because the number of internee user increases and high speed internet data transmission is required. But the present optical cable winding systems has some serious problems such as pile-up and collapse of cable usually near the flange of the bobbin in the process of the cable winding. To reduce the pile-up collapse in a cable winding systems, a new guiding system is developed for a high-speed self-align cable winding. First of all, the winding mechanism was analyzed and synchronization logics for the motions of winding, traversing, and the guiding were created. A prototype cable winding systems was manufactured to validate the new guiding system and the suggested logic. Experiment results showed that the winding system with the developed guiding system outperformed the system without the guiding system in reducing pile-up and collapse in the high-speed winding.

Evaluation of Insulation Characteristics of EHV XLPE Power Cable (초고압 XLPE 전력케이블의 절연특성평가(I))

  • Jeong, K.H.;Baeg, I.J.;Lee, I.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1617-1619
    • /
    • 1998
  • In the nation, 154kV XLPE cable with an insulation thickness of 23mm have been used for transmission lines. The thickness is designed by old parameters which were determined by Kreuger, Oudin et al. in 1960s. By the way, the manufacturing technology has been developed. Especially in extruding and curing process we are using a triple common extruding head and applying gas-curing process. It allows the quality of XLPE cable improved. The paper evaluates the AC minimum insulation breakdown strength of XLPE power cable using model table. We can verify the uplifted insulation quality. And we expects the cable insulation thickness to be reduced applying the new parameter to the cable insulation design.

  • PDF

A Study on Shielding characteristics of Cable used in High-efficiency Automobile (고효율 자동차용 고전압 케이블의 차폐특성에 관한 연구)

  • Lee, Bong-Yi;Lee, Sang-Seon;Yoon, Seung-Hoon;Park, Kyung-Hoon;Youn, Bok-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1892-1893
    • /
    • 2007
  • Because High efficiency electric vehicles use electrical energy by an power source, radiated noise at high voltage cable bring on problems at other electric/electronic components. But, in order to insure shielding effectiveness increasing braid density infinitely, it is possible that the cost is more than one third of cost of manufacturing cable. Accordingly in this paper, we studied design of cost-effective and light shield cable using dual shielding system of braid and al-foil.

  • PDF

Development of a Self-Activated Cable Spooling System for Seaborne Winch (함상용 윈치 자제구동형 케이블 정렬 시스템 개발)

  • Cho, S.H.;Park, R.S.;Woo, S.W.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.9
    • /
    • pp.15-21
    • /
    • 1997
  • In this paper, a self-activated cable spooling system for seaborne winch is developed . The system consists of a hydraulic servo driving unit and a cable position measurement mechanism. To realize the cable spooling system, it is carried out the mathematical modelling of the system and designed the proportional controller through the system aalysis and the simulation. The cable spooling system is tested and evaluated to validate the performance of the controller. The test results shows a good traceability of the cable spooling system under disturbance of cable tension.

  • PDF

Economic analysis of a 22.9 kV HTS power cable and conventional AC power cable for an offshore wind farm connections

  • Jung, Ga-Eun;Dinh, Minh-Chau;Sung, Hae-Jin;Park, Minwon;Yu, In-Keun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.20 no.4
    • /
    • pp.60-64
    • /
    • 2018
  • As the offshore wind farms increase, interest in the efficient power system configuration of submarine cables is increasing. Currently, transmission system of the offshore wind farm uses almost AC system. High temperature superconducting (HTS) power cable of the high capacity has long been considered as an enabling technology for power transmission. The HTS cable is a feasible way to increase the transmission capacity of electric power and to provide a substantial reduction in transmission losses and a resultant effect of low CO2 emission. The HTS cable reduces its size and laying sectional area in comparison with a conventional XLPE or OF cable. This is an advantage to reduce its construction cost. In this paper, we discuss the economic feasibility of the 22.9 kV HTS power cable and the conventional AC power cables for an offshore wind farm connections. The 22.9 kV HTS power cable cost for the offshore wind farm connections was calculated based on the capital expenditure and operating expense. The economic feasibility of the HTS power cable and the AC power cables were compared for the offshore wind farm connections. In the case of the offshore wind farm with a capacity of 100 MW and a distance of 3 km to the coast, cost of the 22.9 kV HTS power cable for the offshore wind farm connections was higher than 22.9 kV AC power cable and lower than 70 kV AC power transmission cable.

Design and Implementation of the Cable Rod Hydraulic Actuator for Robotic Revolute Joints (로봇의 회전관절을 위한 케이블 로드를 갖는 유압 구동기 설계 및 구현)

  • Kim, Jungyeong;Park, Sangdeok;Cho, Jungsan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.9
    • /
    • pp.723-730
    • /
    • 2016
  • This paper presents a cable-driven hydraulic actuator named Cable Rod Hydraulic Actuator (CRHA). The cable actuating system is attractive for designing a compact joint in robotic applications since it can be installed remotely from the joint. Recently, cable rods have been used in pneumatic area for inertia reduction. However, designing cable rods in hydraulics is challenging because it is difficult to achieve flexibility and endurance simultaneously under high pressure conditions. In this paper, the cable rod, which consists of a cable and jacket, is proposed to meet both requirements. To design the CRHA, we determined the design parameters, such as cylinder size, and selected the cable rod's material by friction and leakage test. Finally, comparisons experiments about step and frequency responses with conventional hydraulic actuators were performed to assess feasibility for robotic joints, and the results show that the proposed system has good bandwidth and fast response as robotic joints.

Evaluation of Tension of Stay Cable using MBM (Measurement-based Model) (계측기반모델에 의한 사장케이블의 장력 평가)

  • Nam, Sang-Jin;Yhim, Sung-Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.93-100
    • /
    • 2014
  • This study presents the recomposition of MBM (measurement-based model) using natural frequencies and modes from the usually measured data, and the evaluation of cable tension in service from the analysis results upon MBM of existing CSB (cable stayed bridge). The cable tension is shown to be different according to the position attached to cable and loading type. The measured cable tensions are not different distinctly according to position attached cable under dead and live loads, but larger than those under design loads. The distribution of cable tension calculated upon the MBM is similar to those of measured tension although the former is more than those of cable tension upon the design model. Considering to long-term behaviors of cable, therefore, the design of cable in CSB needs to apply the analysis results on MBM. For this purpose, future study needs lots of measured data and MBM is used to analyze the long-term behavior of cable in CSB.

A Consideration on the Causes of 22.9kV Cable Terminal Burning Accident (22.9kV 케이블 단말 부위 소손 사고의 원인에 관한 고찰)

  • Shim, Hun
    • Journal of Internet of Things and Convergence
    • /
    • v.8 no.2
    • /
    • pp.7-12
    • /
    • 2022
  • The main cause of cable accidents is the accelerated deterioration of the cable itself or internal and external electrical, mechanical, chemical, thermal, moisture intrusion, etc., which reduces insulation performance and causes insulation breakdown, leading to cable accidents. Insulation deterioration can occur even when there is no change in the appearance of the cable, so there is a difficulty in preventing cable accidents due to insulation deterioration. Since cable accidents can occur in areas with poor insulation due to the effects of overvoltage and overcurrent, it is necessary to comprehensively analyze transformers and circuit breakers, and ground faults caused by phase-to-phase imbalance. Ground fault accidents due to insulation breakdown of cables can occur due to defects in the cable itself and poor cable construction, as well as operational influences, arcs during operation of electrical equipment (switchers, circuit breakers, etc.). analysis is needed. This study intends to examine the causes of cable accidents through analysis of cable accidents that occurred in a manufacturing factory.

Investigation on mechanics performance of cable-stayed-suspension hybrid bridges

  • Zhang, Xin-Jun
    • Wind and Structures
    • /
    • v.10 no.6
    • /
    • pp.533-542
    • /
    • 2007
  • The cable-stayed-suspension hybrid bridge is a cooperative system of the cable-stayed bridge and suspension bridge, and takes some advantages and also makes up some deficiencies of both the two bridge systems, and therefore becomes strong in spanning. By taking the cable-stayed-suspension hybrid bridge, suspension bridge and cable-stayed bridge with main span of 1400 m as examples, the mechanics performance including the static and dynamic characteristics, the aerostatic and aerodynamic stability etc is investigated by 3D nonlinear analysis. The results show that as compared to the suspension bridge and cable-stayed bridge, the cable-stayed-suspension hybrid bridge has greater structural stiffness, less internal forces and better wind stability, and is favorable to be used in super long-span bridges.