• Title/Summary/Keyword: OF Cable

Search Result 4,690, Processing Time 0.034 seconds

The Development of the compact accessories for 230kV XLPE cable (Compact 230kV 케이블용 접속함 개발)

  • Lee, Hyeong-Seok;Son, Si-Ho;Kim, Kwang-Soo;Lee, Kwang-Yeol;Chang, Ki-Wook;Bai, Kyung-Moo
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1075-1077
    • /
    • 1999
  • XLPE cables are being used more widely all over the world as extra-high voltage transmission lines owing to the superior characteristics compared to OF cables. In view of the worldwide trend of utilizing high stress cables, we developed the accessories for 230kV XLPE cables which have smaller insulation thickness than that of present cables. The performance of the newly developed 230kV cable and its accessories has superior inital characteristics. As a result, the improved reliability of 230kV XLPE cable system has been obtained. This paper describes the major design concept and the test results of development procedure.

  • PDF

A study on the non-linear analysis of the elastic catenary cable considering kinetic damping (동적감쇠를 고려한 탄성 현수선 케이블의 비선형 해석에 관한 연구)

  • 한상을;정명채;이진섭
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2000.10a
    • /
    • pp.331-338
    • /
    • 2000
  • In this paper, a non-linear finite element formulation for the spatial cable-net structures is simulated and using this formulation, the characteristics of structural behaviors for the elastic catenary cable are examined In the simulating procedure for the elastic catenary cable, nodal forces and tangential stiffness matrices are derived using catenary parameters of the exact solutions by a governing differential equation of catenary cable, cable self-weights and unstressed cable length. Dynamic Relaxation Method that considers kinetic damping is used for the structure analysis and Newton Raphson Method is used to verify the accuracy of solutions. In the analysis of two dimensional cable, the results obtain from the elastic catenary elements are shown more accurate than does of truss elements and in the case of spatial cable-net structures, Dynamic Relaxation Method is more stable to be converged than Newton Raphson Method.

  • PDF

Electrical Insulation Design and Experimental Results of a High-Tc Superconducting Cable (고온초전도 케이블의 전기절연 설계 및 시험평가)

  • Kwag, Dong-Soon;Cheon, Cheon-Gweon;Choi, Jae-Hyeong;Kim, Hae-Jong;Cho, Jeon-Wook;Kim, Sang-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.12
    • /
    • pp.640-645
    • /
    • 2006
  • A 22.9kV/50MVA class high temperature superconducting(HTS) power cable system was developed in Korea. For the optimization of electrical insulation design for a HTS cable, it is necessary to investigate the ac breakdown impulse breakdown and partial discharge inception stress of the liquid nitrogen/laminated polypropylene paper(LPP) composite insulation system. They were used to insulation design of the model cable for a 22.9kV class HTS power cable and the model cable was manufactured. The insulation test of the manufactured model cable was evaluated in various conditions and was satisfied standard technical specification in Korea. Base on these experimental data, the single and 3 phase HTS cable of a prototype were manufactured and verified.

Experimental Analysis on the Cable Tension During the Laying and Recovery of a Submarine Cable (해저케이블 포설/회수시 장력에 대한 실험적 분석)

  • Yang Seung-Yun;Kim Jeong-Hoon;Kim Kyung-Sub;Kim Jae-San;Park Kwi-Ho;Kim Gee-Won;Lee Sang-Ho
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.8 no.1 s.20
    • /
    • pp.32-38
    • /
    • 2005
  • In this study, Experimental analysis on submarine cable tension was performed for the safe and efficient laying and recovery of a submarine cable. The tension analysis was done through the analyzed data using the cable dynamic theory and the measured data using the experiment. The analyzed cable tension was able to decide requirements for the purpose of laying and recovery of the submarine cable. As the result of tension analysis for a Submarine cable, it was shown a proper feasibility to determine the laying and recovery conditions of the submarine cable.

A Study on the Structural Behavior of Cable Domes (케이블 돔의 구조적 거동 특성에 관한 연구)

  • 한상을;윤종현;이승훈;진영상;황보석
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2000.10a
    • /
    • pp.151-158
    • /
    • 2000
  • Cable dome that consists of three component such as cable, strut and fabric membrane has complex structural characteristics. Main structural system of cable dome is cable-strut tensegric system and fabric membrane element is conceived as cladding roof material. One of the important problem of cable dome is to investigate the structural response from external load effect such as snow and wind. When cable dome is subjected to load each structural component has various special structural characteristics. One is that geometrical nonlinearity should be considered because large deformation is occurred from their flexible characteristic. The other is that wrinkling occurs occasionally because cable and membrane elements can not transmit compressive forces. So this paper researches the physical structural response of cable dome structure and the structural behavior when failure occurred at a part of structure.

  • PDF

Influence of Partial Discharge Properties due to Void in Cable Joint Parts (케이블 접속재 부분방전 특성에 미치는 보이드의 영향)

  • 신종열;홍진웅
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.3
    • /
    • pp.69-74
    • /
    • 2003
  • To investigate the partial discharge and electric field distribution in cable joint parts, we measured the partial discharge and electric field in specimen. The specimens which cross-linked polyethylene(XLPE) and ethylene propylene diene ethylene(EPDM) are used to insulating material for underground cable md cable jointing parts. The polymers are used to insulating material in switchgear which is a kind of transformer equipment and in ultra-high voltage cable. Its using is increasing gradually, the electrical insulation properties are not only excellent but also mechanical property is excellent. And because it is possible to be made void of several type in insulator while it is produced, which the electrical field distribution is changed by void, it has a critical influence to insulator performance. The underground cable is connecting by the jointing material, insulating breakdown and the electric ageing which are caused by several mixing impurity and the damage of cable insulator layer, which reduced the life of cable while intermediate joint kit is connected. Therefore, the computer simulation is used to estimating insulator performance, XLPE is used to the insulating material of ultra-high voltage cable and EPDM is used to insulator layer in joint material kit, and which are produced as specimen. And it is analyzed the electric field concentrating distribution and partial discharge by modeling of computer simulation in void and cable joint kit.

Application of Protecting Methods for Single Point Bonding on Underground Transmission Cable (지중 송전 케이블의 편단접지 시스템에서의 계통 보호 방안)

  • Ha, C.W.;Kim, J.N.;Lee, I.H.;Kim, J.C.;Lee, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.15-17
    • /
    • 2005
  • The protection of underground cables against transient overvoltages resulting from lightning and other causes is important in cable-line which is connected with overhead line and underground cable. This paper investigates the failure of SVL(Sheath Voltage Limiter) and presents the application of protection methods for single point bonding on underground transmission cable system. EMTP(Electromagnetic Transient Program) is used in order to study the overvoltages and modeling of components of the system such as, underground cables, SVLs and towers.

  • PDF

A Study on Factors that Affect Impulse Purchase on Cable TV Home-shopping (Cable TV 홈쇼핑에서의 충동구매에 영향을 미치는 요인)

  • 이은희;종은영
    • Journal of Families and Better Life
    • /
    • v.21 no.2
    • /
    • pp.61-74
    • /
    • 2003
  • Recently, the number of consumers who buy various goods using the shopping channels on cable TV has increased. The objectives of this study are to examine the propensity of consumers to make an impulse purchase through cable TV, and to investigate the factors that influence consumers' impulse purchase. The following was found in this study: (1) The propensity of consumers to make impulse purchases on cable TV is somewhat low, Among sub-areas of impulse purchase, the propensity to make impulse purchase by suggestion is the highest. (2) Among the variables that affect consumers' impulse purchase on cable TV, the most influential variable is the psychological factor, followed by the frequency of shopping on cable TV, positive testimony from consumers who have used the product, and the amount of time spent in watching shopping channels on cable TV, in that order.

A Experimental Study on the Fire Hazard Analysis For Communication Cable in Buildings (건축물내 통신용 케이블의 화재위험성 분석에 관한 실험연구)

  • Hong, Sung-Ho;Choi, Moon-Soo
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.6
    • /
    • pp.20-25
    • /
    • 2011
  • This study presents on the fire hazard analysis of communication cable in buildings. In order to analyze fire hazards for communication cable IEC 60332-1, UL 94 and cone calorimeter test are conducted. The number of cable used to experiment is 10 communication cable which are generally applied to data communication in buildings. The results show that 9 cables do meet the performance requirement of IEC 60332-1 and 8 cables are V-0 classification. IEC 60332-1 and UL 94 test are inadequate for fire hazard classification. The various parameters obtained by cone calorimeter test such as HRR, peak HRR, smoke production rate and so on. Also it is able to evaluate multiply fire hazard for communication cable with cone calorimeter test results.

A study result on coordinative protection method of HTS cable implemented distribution system (초전도케이블이 병입된 계통의 고장에 대한 보호협조 검토기법)

  • Lee, Hyun-Chul;Yang, Byeong-Mo;Lee, Geun-Joon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.700-704
    • /
    • 2011
  • This paper proposes a coordinative protection study results of 22.9kV HTS(High-Temperature Superconducting) cable implemented distribution system. HTS cable can provide about 5 times larger transfer capacability compare to conventional XLPE cable, however, it has different heat characteristic so called quench. This paper presents the simulation results on Ichun substation HTS cable which connects main transformer and 22.9kV bus. Various expected fault cases are considered and discussed to examine whether conventional protection scheme is effective to protect both of existing facilities and HTS cable. With the results of simulation, conventional protection scheme can be used if instantaneous element and time inverse elements could be adjusted with proper time coordination. Internal temperatures of HTS cable conductor in safe region with proper protection without quench. This results are to be demonstrated by the field test and will be implemented in Ichon substation HTS cable protection and control system.