• 제목/요약/키워드: O-D table

검색결과 72건 처리시간 0.027초

레이저 구조광 영상기반 3차원 스캐너 개발 (Development of 3D Scanner Based on Laser Structured-light Image)

  • 고영준;이수영;이준오
    • 제어로봇시스템학회논문지
    • /
    • 제22권3호
    • /
    • pp.186-191
    • /
    • 2016
  • This paper addresses the development of 3D data acquisition system (3D scanner) based laser structured-light image. The 3D scanner consists of a stripe laser generator, a conventional camera, and a rotation table. The stripe laser onto an object has distortion according to 3D shape of an object. By analyzing the distortion of the laser stripe in a camera image, the scanner obtains a group of 3D point data of the object. A simple semiconductor stripe laser diode is adopted instead of an expensive LCD projector for complex structured-light pattern. The camera has an optical filter to remove illumination noise and improve the performance of the distance measurement. Experimental results show the 3D data acquisition performance of the scanner with less than 0.2mm measurement error in 2 minutes. It is possible to reconstruct a 3D shape of an object and to reproduce the object by a commercially available 3D printer.

색상 보정을 통한 3차원 TV의 입체영상 화질 개선 (3D Video Quality Improvement for 3D TV using Color Compensation)

  • 정길수;강민성;김동현;손광훈
    • 방송공학회논문지
    • /
    • 제15권6호
    • /
    • pp.757-767
    • /
    • 2010
  • 본 논문은 3차원 TV 시청에 있어서, 2차원에서와 같은 색감을 최대한 제공하기 위한 방법을 연구하였다. 이를 위하여 입력 RGB 색상 막대(color bar) 영상을 기준으로 2차원과 3차원 재생시 재현되는 RGB 강도의 입출력 관계를 모델링하였으며, 이를 근거로 2차원 대비 보정되어야 할 3차원 색상 사상표(mapping table)를 생성하였다. 생성된 사상표를 기존 3차원 TV 시스템의 출력부에 추가하여, 일반 2차원 재생시에는 입력 영상을 우회(bypass)하도록 하고, 3차원 재생시 색상 보정 과정을 수행하도록 하여 3차원 재생시에도 2차원에서 느낄 수 있는 색감을 재현할 수 있도록 하였다.

단층촬영영상을 이용한 T.O.D Calibration의 정확성과 유용성에 관한 비교연구 (Comparative Study on Accuracy and Usefulness of Calibration Using CT T.O.D)

  • 서정범;김동현;이정범
    • 대한디지털의료영상학회논문지
    • /
    • 제13권1호
    • /
    • pp.39-48
    • /
    • 2011
  • Uses a Tomographic scan image and Table Object Distance(TOD) price after measuring, uses accuracy and usability of blood vessel diameter(Vessel Diameter) measurement under comparison evaluating boil TOD Calibration. The patient who enforces Prosecuting Attorney abdomen Tomographic scan in the object the superior mesentery artery uses PACS View from abdomen fault image and from blood vessel diameter and the table measures the height until of the blood vessel. Uses Angio Catheter from Angiography(5 Fr.) and enforces is measured from PACS View the height until of the table which and the blood vessel at TOD Calibration price and the size of the superior mesentery artery inputs measures an superior mesentery artery building skill. Catheter Calibration input Agnio Catheter where uses in Angiography the size of the superior mesentery artery at Catheter Calibration price and they measure. Produced an accuracy from monitoring data and comparison evaluated. The statistical program used SPSS. TOD Calibration accuracy was 96.53%, standard deviation is 0.03829. Catheter Calibration accuracy of 92.91%, standard deviation is 0.05085. Represents a statistically significant difference(p = 0). According to age and gender was not statistically significant(p > 0.05). TOD Calibration correlation coefficient R-squared of 88.8%, Catheter Calibration of the R-squared is 75.5%. High accuracy of both methods. Through this study, CT images using the measured distance between the table and the Object, TOD Calibration accuracy higher than two Catheter Calibration was measured. TOD and Catheter Calibration represents a statistically significant difference(p = 0).

  • PDF

자기 베어링으로 지지 되는 직선운동 테이블의 초정밀 위치제어에 관한 연구 (Micropositioning of a Linear Motion Table with Magnetic Bearing Suspension)

  • 김의석;안형준;장인배;한동철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.466-469
    • /
    • 1995
  • This paper presents a design and performance of the 6 D.O.F linear motion table with a magnetic bearing suspension. The linear positioning of the table with a 150mm stroke is driven by a brushless DC Linear motor and the other attitudes of the stage are controlled by the analog PD controller with magnetic bearing actuators. Each magnetic bearing unit which consists of 3 electromagnets, 3 capacitance probes and 3 backup bearings affords controlled forces by detecting the air gap between the probes and guideways. An integral type capacitance probe amplifier is equipped on the upper plate of the table so that the probe line to the probe amplifier can be shorter therefore the problems due to the stray capacitance and noise can be reduced. Form the pitch-yaw errormeasured by the autocollimator, the vertical and horizont straightness errors of the table are derived that they are maintained below 1.mu. m over 100mm stroke. The positioning accuracy of the linear motion is maintained below 2 .mu. m and the repeatability error is below 1 .mu. m

  • PDF

대규모 미시교통시뮬레이션모형 구축을 위한 O/D 추정 방법 성능 비교 - 중력모형과 QUEENSOD 방법을 중심으로 - (Comparison Study of O/D Estimation Methods for Building a Large-Sized Microscopic Traffic Simulation Network: Cases of Gravity Model and QUEEENSOD Method)

  • 윤정은;이철기;이환필;김경현;박원일;윤일수
    • 한국도로학회논문집
    • /
    • 제18권2호
    • /
    • pp.91-101
    • /
    • 2016
  • PURPOSES : The aim of this study was to compare the performance of the QUEENSOD method and the gravity model in estimating Origin-Destination (O/D) tables for a large-sized microscopic traffic simulation network. METHODS : In this study, an expressway network was simulated using the microscopic traffic simulation model, VISSIM. The gravity model and QUEENSOD method were used to estimate the O/D pairs between internal and between external zones. RESULTS: After obtaining estimations of the O/D table by using both the gravity model and the QUEENSOD method, the value of the root mean square error (RMSE) for O/D pairs between internal zones were compared. For the gravity model and the QUEENSOD method, the RMSE obtained were 386.0 and 241.2, respectively. The O/D tables estimated using both methods were then entered into the VISSIM networks and calibrated with measured travel time. The resulting estimated travel times were then compared. For the gravity model and the QUEENSOD method, the estimated travel times showed 1.16% and 0.45% deviation from the surveyed travel time, respectively. CONCLUSIONS : In building a large-sized microscopic traffic simulation network, an O/D matrix is essential in order to produce reliable analysis results. When link counts from diverse ITS facilities are available, the QUEENSOD method outperforms the gravity model.

중력모형에서 존내 분포통행 예측방법에 관한 연구 (A Study on Inner Zone Trip Estimation Method in Gravity Model)

  • 유영근
    • 대한토목학회논문집
    • /
    • 제26권5D호
    • /
    • pp.763-769
    • /
    • 2006
  • 중력모형은 출발 존의 유출통행량과 도착존의 유입통행량, 그리고 출발존 중심에서 도착존 중심까지의 교통저항을 이용하여 장래 분포통행을 예측한다. 중력모형에서 존내통행 예측의 경우 교통저항이 "0"로 산정되기 때문에 중력모형에 의해 예측하지 못하고 성장율법과 같은 타 방법에 의해 예측을 행해야 하는 어려움이 존재했다. 본 연구에서는 중력모형에 의한 분포통행 예측시 구축된 중력모형을 이용하여 존내 분포통행을 예측하는 방법을 제안하였는데, 제안한 방법은 기준연도의 존내 분포통행량과 유출, 유입통행량을 존간통행에서 구축된 중력모형식에 대입하여 존내 교통저항을 산출하고 이를 다시 중력 모형에 대입하여 장래 존내 분포통행 예측을 행하는 것이다. 1988년 O-D표를 기준연도 O-D로 하고, 본 연구에서 제안한 방법과 기존의 방법인 성장률법과 회귀모형법의 1992년과 2004년 예측결과들을 실제 O-D와 $x^2$, RMSE, 상관계수 등으로 비교 분석해 본 결과, 본 연구에서 제안한 방법이 우수한 결과를 나타내었다.

CMI와 THI에 의한 서울시내 개인택시 사업장에 근무하는 근로자의 신체적 자각증상에 관한 연구 (A Study about physical awareness symptoms of workers working at Seoul driver-owned taxi workplace by THI and CMI)

  • 손종렬;변상훈;김경은;최달웅
    • 환경위생공학
    • /
    • 제18권4호
    • /
    • pp.52-63
    • /
    • 2003
  • This paper investigated Taxi drivers physical subjective symptoms and what factors were interviewed caused the symptoms. The 600 owning taxi-drivers in Seoul during four months from August 1st, 2003 to November 30th, 2003. 1. The average age of the owning taxi-drivers was generally quite high 54 years old. It was very high index compared with the Todai Health Index(THI) and Cornell Medical Index(CMI) of health check tables. 2. According to the age in THI health check table, the complains of mental subjective symptom by reason of age was high among 31 to 40 years old. People who belonged that age group showed high fabrication(L), digestion(C) and aggressiveness(F). The results showed the complains of mental subjective symptom. All items except tiredness(I), melancholia(N), and hypersensitivity(P) were commonly reported by people in their sixties. On the other hand, melancholia(N) and hypersensitivity(P), people in their forties were investigated highly. Statistically, the items of heartㆍblood stream(C) and digestion(D) systems were similar between the two ages, but anger(Q) was different. (p<0.05) 3. From the complains of mental and physical subjective symptoms about work satisfaction on the THI health check table, all items except eyeㆍskin trouble(B) showed strong dissatisfaction. From the complains of mental and physical subjective symptoms about work satisfaction on the CMI health check table, the items of respiratory system(B), digestion(D), nervous system(G), miscellaneous(K), inadequancy(M), and anger(Q) showed similar results. Otherwise, heartㆍblood stream(C) showed statistically different. 4. From the complains of mental and physical subjective symptoms on salary satisfaction in the THI health check table, in the case of people receiving around 1 million won, the complains of physical symptoms showed high among all items except for the respiratory(A) and digestion(C) systems. The eyeㆍskin trouble(B) item showed statistical similarity. The complains of mental and physical subjective symptoms according to a salary degree on the CMI health check table was completely different from the above results. In people received around 1~1.5million won, all items except anxiety(O) showed high. The hypersensitivity(P) item showed statistically different.

Crystallization and Electrical Properties of $Ba_2TiSi_2O_8$ Glass-Ceramics from $K_2O-BaO-TiO_2-SiO_2$ System

  • Chae, Su-Jin;Lee, Hoi-Kwan;Kang, Won-Ho
    • 한국반도체및디스플레이장비학회:학술대회논문집
    • /
    • 한국반도체및디스플레이장비학회 2006년도 추계학술대회 발표 논문집
    • /
    • pp.110-114
    • /
    • 2006
  • Dielectric properties of glass-ceramics with fresnoite(Ba2TiSi208) crystals have been investigated in xK20-(33.3-x)BaO-16.7TiO2-50SiO2 ($0{\leq}x{\leq}20mol%$) glasses. The glassy nature was analyzed by differential thermal analyses and glass-ceramics was variable and control table by the processing parameters like time and temperature. Dielectric constant was measured over a temperature from 125K to 425k at frequencies form 100Hz to 1MHz, and laid in the range 16-10. Piezoelectric constant d33 was measured using a YE2703A d33meter and changed from 5.9 to 4.8pCN-1 with x contents. The spontaneous polarization Ps estimated from the hysteresis at ${\pm}1.2kV$ was ${\sim}0.3\;{\mu}C/cm2$ at room temperature.

  • PDF

수단O/D기반 및 P/C기반 화물수요추정방식의 실증적 비교: 우리나라 컨테이너 화물을 중심으로 (An Empirical Study on Comparative Analysis of Freight Demand Estimation Methods - Unimodal O/D Based Method and P/C Based Method : Focus on Korean Import/Export Container Freight)

  • 김현승;박동주;김찬성;최창호;조한선
    • 대한교통학회지
    • /
    • 제31권2호
    • /
    • pp.45-59
    • /
    • 2013
  • 이 연구는 우리나라에서 현재까지 사용되어 온 (수단O/D기반)화물수요추정법의 문제점 인식을 바탕으로 P/C기반 화물수요추정법과 비교 분석을 수행하였다. 우리나라 화물수단O/D는 화물의 최초기점과 최종종점 간 운송을 수단별 통행으로 나누어 인식하면서 접근트럭통행(Access/Egress Truck Trip)에 대한 정보가 누락되어있다. 이러한 이유로 수단O/D기반 화물수요추정법은 화물의 복합수단운송을 반영하지 못하는 단점이 있다. 이에, 본 연구는 우리나라 컨테이너 화물을 중심으로 P/C표와 복합수단선택모형을 추정하여 P/C기반 화물수요추정법을 제시하고, 기존 사용되어 오던 수단O/D기반 화물수요추정법과 기종점쌍 간 전환량, 수단통행물동량, 링크물동량을 비교하였다. 비교 결과 P/C기반 화물수요추정법은 복합운송을 제대로 모사하지 못하는 기존 수단O/D기반 화물수요추정법의 문제점을 해결할 수 있는 것으로 평가되었다.