• Title/Summary/Keyword: O-D 분석

Search Result 1,530, Processing Time 0.029 seconds

A Study on the Performance Improvement of Turbo Coded OFDM Systems Considering Frequency Offset (주파수 오프셋을 고려한 Tued OFDM 시스템의 성능 개선에 관한 연구)

  • 이영춘;박기식
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.5
    • /
    • pp.908-915
    • /
    • 2001
  • In this paper, it is analyzed theoretically that the performance degradation, caused by carrier frequency offset, in an OFDM/M-ary PSK system. Then, when Turbo coding is adopted to an OFDM/M-ary PSK system, the degree of performance enhancement is evaluated. Finally, the maximum frequency offset is calculated to satisfy the BER performance required in a Turbo coded OFDM/M-ary PSK system. As results of analysis, it is shown that the more the number of M-ary is, the worse the BER performance is. Moreover, 7dB, 9dB, and 17dB of $E_b/N_o$ are required in QPSK, 8PSK and 16PSK systems, respectively in order to satisfy the error performance, $BER=10^{-3}$ for voice communication. If $E_b/N_o$ are 10㏈ and 15㏈, the frequency offset should be below 0.05 and 0.075, respectively, for voice communication. When Turbo coding is adopted to an OFDM/M-ary PSK system, the less the number of M-ary is, the greater the performance enhancement of Turbo coding is. If the number of a M-ary system of the system is below 16, it is found that required $E_b/N_o$ is about 8dB to satisfy $BER=10^{-5}$ Moreover, in the system the Turbo coding scheme, voice communication is available with greatly low$E_b/N_o$, and 8dB of $E_b/N_o$ is enough for data communication regardless of the permission range of frequency offset.

  • PDF

2D-QSAR and HQSAR Analysis on the Herbicidal Activity and Reactivity of New O,O-dialkyl-1-phenoxy-acetoxy-1-methylphosphonate Analogues (새로운 O,O-dialkyl-1-phenoxyacetoxy-1-methylphosphonate 유도체들의 반응성과 제초활성에 관한 2D-QSAR 및 HQSAR 분석)

  • Sung, Nack-Do;Jang, Seok-Chan;Hwang, Tae-Yeon
    • The Korean Journal of Pesticide Science
    • /
    • v.11 no.2
    • /
    • pp.72-81
    • /
    • 2007
  • Quantitative structure-activity relationships (QSARs) on the pre-emergency herbicidal activity and reactivity of a series of new O,O-dialkyl-1-phenoxyacetoxy-1-methylphosphonates (S) analogues against seed of cucumber (Cucumus Sativa) were discussed quantitatively using 2D-QSAR and HQSAR methods. The statistical values of HQSAR model were better than that of 2D-QSAR model. From the frontier molecular orbital (FMO) interaction between substrate molecule (S) and $BH^+$ ion (I) in PDH enzyme, the electrophilic reaction was superior in reactivity. From the effect of substituents, $R_2$-groups in substrate molecule (S) contributed to electrophilic reaction with carbonyl oxygen atom while X, Y-groups contributed to nucleophilic reaction with carbonyl carbon atom. And the influence of X,Y-groups was more effective than that of $R_2$-groups. As a results of 2D-QSAR model (I & II) and atomic contribution maps with HQSAR model, the more length of X, Y-groups is longer, the more herbicidal activity tends to increased. And also, the optimal ${\epsilon}LUMO$ energy, $({\epsilon}LUMO)_{opt.}$=-0.479 (e.v.) of substrate molecule is important factor in determining the herbicidal activity. It is predicted that the herbicidal activity proceeds through a nucleophilic reaction. From the analytical results of 2D-QSAR and HQSAR model, it is suggested that the structural distinctions and descriptors that contribute to herbicidal activities will be able to applied new herbicide design.

Determination of the Optimal Bus-stop Location and Headway of Bus Rapid Transit Using Bus-stop-based O-D Data (급행버스 노선의 정류장 위치 및 배차간격 결정에 관한 연구 (노선별 정류장간 O-D 자료를 활용하여))

  • Cho, Hye-Jin;Lee, Young-In
    • Journal of Korean Society of Transportation
    • /
    • v.23 no.7 s.85
    • /
    • pp.63-74
    • /
    • 2005
  • When we introduce the BRT systems, it is very important to decide the operating factors, such as bus-stop locations or headway. If the factors are inappropriate, unessential expenses for the operator and users of the bus line may be caused, and it leads increase of social total cost. So, it is necessary that we consider users' origin and destination of each bus line when we set location of bus-stops and the optimal headway. Meanwhile, Smart Card System was introduced of fare collection for the Public Transportation Reform in Seoul last year. This new card system makes it possible to store up the information about bus operating and passenger's trip link. With these substantial information. we can estimate bus-stop-based O-D table. So, in this thesis, it was studied a systematic methodology to find the optimal location and headway for skip-stop bus system (as a type of first step for BRT). The proposed methodology in this thesis is expected to be useful to effect analysis or setting operating factors for skip-stop bus system in each bus line.

Electromagnetic Properties of Mo-Zn ferrite for Low Voltage and High Current Transformer Application With Using Multi cores (다중 코어를 이용한 저전압, 대전류 변압기용 Mn-Zn ferrite의 전자기적 특성)

  • Kim, Hyun-Sik;Lee, Hae-Yon;Kim, Jong-Ryung;Huh, Jeong-Seob;Lee, Jun-Hui;An, Yong-Woon;Oh, Young-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.294-295
    • /
    • 2005
  • 다중 코어를 이용한 대전류 변압기용 Mn-Zn ferrite를 제조하고 전자기적 특성을 분석하였으며, 제조된 자심재료를 이용하여 변압기를 제조하고 전원장치에 탑재하여 효율특성을 분석하였다. ZnO의 몰비가 증가할수록 혼합 스피넬의 형성을 통한 보아 자자의 증가로 인해 투자율은 증가하고 상대적으로 전력손실이 감소하여 $Fe_2O_3$ : MnO : ZnO = 53 : 36 : 11 mo\% 일 때 가장 우수한 특성을 나타냈고, 열처리 공정의 승온 과정에서부터 산소 분압을 제어하고 최적의 대기압 상수를 산출함으로써 Zn-loss 현상을 최소화하여 ZnO 11 mol%, 대기압 상수 7.7일 때 투자율 2350, 밀도 4.9 $g/cm^3$, 비저항 480 ${\Omega}cm$, 300 mT의 최대 자속 밀도 특성을 갖는 우수한 자심 재료를 개발하였다. 그리고 최소 손실 온도를 $90^{\circ}C$ 이하로 감소시켰으며 100 kHz에서 250 $kW/m^3$의 낮은 전력손실을 나타냈다. 또한 개발된 자심재료를 이용하여 제조된 전원장치는 30~80A의 출력 전류에서 85% 이상의 고효율을 얻었다.

  • PDF

Analysis of Tax Passenger Travel Patterns based on Busan DTG Data (DTG 자료 기반 택시 이용자 통행패턴 분석: 부산시 택시 사례)

  • Ahn, Sang Ha;Shin, Yong Eun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.6
    • /
    • pp.907-916
    • /
    • 2018
  • This study presents a methodology that can integrate the information generated by the Busan taxi DTGs and Tachometers. Utilizing the results by the methodology, travel patterns of taxi users were analyzed. Also to verify the reliability of the methodology was conducted by comparing its results with those of O-D information of the National Transportation DB (KTDB). Despite the limited number of samples. the results of this study showed that DTG data, which can reflect changes in status and conditions in real time, can be used as a replacement for KTDB. It is expected that the results generated by the suggested methodology can be useful for developing and executing desirable taxi related policies.

O-RAN Certification/Badging Process and End-to-End Test Case Analysis (O-RAN 공인시험 프로세스와 종단간 시험 기술 분석)

  • J.H. Kim;G.D. Nam
    • Electronics and Telecommunications Trends
    • /
    • v.39 no.1
    • /
    • pp.14-24
    • /
    • 2024
  • The O-RAN Alliance is responsible for defining the technical and testing specifications of open radio access networks, aiming for openness, virtualization, and intelligence in these networks. Recently, the application of Korea Open Testing and Integration Center (OTIC) to this alliance has been approved, enabling the issuance of O-RAN certificates and badges. An OTIC plays a crucial role as a testing facility in performing conformance verification and interoperability tests for O-RAN functions and interfaces. In addition, it enables end-to-end system verification adhering to O-RAN principles and processes. These activities can substantially contribute to enhancing the competitiveness of domestic O-RAN products and activating the corresponding ecosystem. We comprehensively describe the O-RAN certification and badging processes. Additionally, we analyze end-to-end test cases that are essential for the proper deployment and operation of 5G systems including O-RANs.

Embedding Algorithm among Folded Hypercube, Even Network and Odd Network (폴디드 하이퍼큐브와 이븐연결망, 오드연결망 사이의 임베딩 알고리즘)

  • Kim, Jong-Seok;Sim, Hyun;Lee, Hyeong-Ok
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.35 no.7
    • /
    • pp.318-326
    • /
    • 2008
  • In this paper, we will analyze embedding among Folded Hypercube, Even Network and Odd Network to further improve the network cost of Hypercube. We will show Folded Hypercube $FQ_n$ can be embedded into Even Network $E_{n-1}$ with dilation 2, congestion 1 and Even Network $E_d$ can be embedded into Folded Hypercube $FQ_{2d-3}$ with dilation 1. Also, we will prove Folded Hypercube $FQ_n$ can be embedded into Odd Network $O_{n-1}$ with dilation 2, congestion 1 and Odd Network $O_d$ can be embedded into Folded Hypercube $FQ_{2d-3}$ with dilation 2, congestion 1. Finally, we will show Even Network $E_d$ can be embedded into Odd Network $O_d$ with dilation 2, congestion 1 and Odd Network $O_d$ can be embedded into Folded Hypercube $E_{d-1}$ with dilation 2, congestion 1.

An Analysis on the Relationship to Input/Output factor and Evaluation Grade in Nuclear R&D Program (연구개발사업의 투입.산출요소 및 연구결과 평가의 상호관계 분석 - 원자력중장기연구개발사업을 중심으로-)

  • Hong Jeong-Jin;Won Byeong-Chul;Yang Maeng-Ho
    • Proceedings of the Korea Technology Innovation Society Conference
    • /
    • 2004.05a
    • /
    • pp.48-56
    • /
    • 2004
  • To perform R&D program, it is necessary to invest input factor(I/F). And these factor are converted to output factors(O/F) at the end of R&D program. Pee. reviewers evaluate output factors and produce evaluation grades(E/G). This paper try to analyze the relationship to I/F, O/F and E/G, According to the analysis results, the relation between I/F and E/G is as weak as the relation between O/F and E/G. The strength of relationship is relatively very strong in the relation between I/F and O/F

  • PDF

Studies on the Molybdenum Complexes with Tetradentate Schiff Base Ligand (I). N,N'-bis (Salicylaldehyde)-ethylene Diimine (네자리 Schiff Base 리간드의 몰리브덴착물에 관한 연구 (제1보))

  • Jo, Gi Hyeong
    • Journal of the Korean Chemical Society
    • /
    • v.18 no.4
    • /
    • pp.267-271
    • /
    • 1974
  • The tetradentate schiff base, N,N'-bis(salicylaldehyde)-ethylene diimine has been reacted with a series of Mo(IV), Mo(V), Mo(IV), and Mo(III) oxidation states to form new Complexes; $[MoO_2(C_{16}H_{14}O_2N_2)], (MoO(C_{16}H_{14}O_2N_2)]_2O, (Mo(SCN)(C_{16}H_{14}O_2N_2)]_2O, and (Mo(H_2O)(C_{16}H_{14}O_2N_2)]_2O.$ These complexes have hexa coordinated configurations and the mole ratio of these ions to the ligand was 1:1. These complexes have been identified by visible spectra, infrared specra, T.G.A., D.T.A., and elemental analysis.

  • PDF

Occurrence of Natural Hybrid between Oplegnathus fasciatus and Oplegnathus punctatus from the South Sea of Korea (한국 남해에서 출현한 돌돔 (Oplegnathus fasciatus)과 강담돔 (Oplegnathus punctatus) 사이의 자연교잡종)

  • Kwun, Hyuck-Joon;Kim, Jin-Koo
    • Korean Journal of Ichthyology
    • /
    • v.22 no.3
    • /
    • pp.201-205
    • /
    • 2010
  • One specimen of a natural hybrid of an Oplegnathus (Oplegnathus fasciatus $\times$ Oplegnathus punctatus) was found in Tongyeong, Korea in August 2008. We, herein, describe its morphological and genetic characteristics and compare them with those of O. fasciatus and O. punctatus. In morphology, the hybrid showed many distinctive black rounded blotches on body sides and four faint vertical bars, being in those features similar to O. punctatus. Although the counts and measurements of the hybrid mostly overlapped between O. fasciatus and O. punctatus, the Oplegnathus hybrid resembled O. punctatus in the ratio of pelvic-fin length in standard length: Oplegnathus hybrid (26.7%) was closer to O. punctatus (26.4%) than to O. fasciatus (17.2~23.6%). In genetics, as a result of analysis of 510 base pair sequences of mitochondrial DNA 16S rRNA, the hybrid was closer to O. fasciatus (d=0.000~0.010) than to O. punctatus (d=0.020). Our results suggest that the natural hybridization represented by the subject specimen occurred between an O. fasciatus female and an O. punctatus male.