Heat transfer of Mixed convection in rectangular space with constant heat flux (일정 열유속의 열원을 갖는 사각공간의 혼합대류 열전달)

  • 조대환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.4
    • /
    • pp.552-558
    • /
    • 1999
  • Ventilation of the marine engine room is very important for the health of the workers as well as the normal operation of machines. To find proper ventilation conditions of this engine room numerical simulation with a standard k-$\varepsilon$model was carried out. In the present study the marine engine room is considered as a closed space with a heat source and forced ventilation ducts. The injection angle of air supply is found to be important. Injection with a downward angle depresses recirculation flow causing a strong stream in the wider space of the room Ventilation and removal of the released heat are promoted with this pattern, There is a possibility of local extreme heating at the upper surface of the engine when supply and exhaust ports of air are in bilateral symmetry.

  • PDF

Ventilation Characteristics by Traffic Piston Effect in Underground Network-type Road Junction (네트워크형 지하도로 입체교차로 내의 교통환기력에 의한 환기 특성)

  • Kim, Nam-Young;Jo, Jong-Bok;Han, Hwataik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.337-343
    • /
    • 2015
  • This paper investigates the ventilation characteristics in a two-dimensional underground network junction composed of four main lines interconnected by eight ramps. Simple one-dimensional models cannot be applied to network junctions since there are interferences of traffic piston effects in the main lines and at the ramps. A numerical algorithm was developed to analyze the pressure and airflow distributions iteratively. The Darcy-Weisbach equation was used to calculate the piston effects by traffic flows, and a Hardy Cross iteration was conducted for network analysis at the interconnected junction. The results show interesting ventilation characteristics and CO concentration distributions depending on system parameters such as vehicle speed, tunnel diameter, and other junction configurations.

Numerical Analysis on the Improvement of Zinc Plating Booth Ventilation System (아연도금 부스 환기시스템 개선에 관한 수치해석)

  • Chin, Do-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.1
    • /
    • pp.45-51
    • /
    • 2021
  • The purpose of this study is to suggest the optimal shape for a local air ventilation system for fume removal, which is operated in a zinc galvanizing factory, and to propose the improvement plan for a ventilation system used in a zinc galvanizing factory through flow analysis. A part of the air sprayed by an air curtain goes out. It will be necessary to research the position of an air curtain, its spray angles, and its nozzle shape. In addition, additional research needs to be conducted on the shape of the fan installed before a hood in order to make it easy to induce fume. In a local air ventilation system, air is inhaled from the outside. The higher an inlet negative pressure is, the easier fume is removed. It was found that it was necessary to install an appropriate hole in the wall on the back of a push nozzle in order to reduce an inlet negative pressure.

A Study on Inhalation Force Improvements of Ventilation Hood For Removed a Pollution Source (유해물질 제거를 위한 국소배기장치 후드의 흡입력 증가에 관한 연구)

  • Yang, Ho-Dong;Kim, Young-Sun;Oh, Yool-Kwon
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2327-2332
    • /
    • 2007
  • This study investigates on the inhalation force improvements of hood consisted one of the local ventilation systems attached the new device named as gas-guidance-device for removed a pollution source. The numerical method applying finite element method is calculated the velocity and pressure distributions of a moving fluid at the beginning and the inside of a hood with and without the gas-guidance-device in hood. And, the experimental study is measured the wind velocity using the anemometer at the same condition of numerical study. Also, the optimum shape of gas-guidance-device which is suitable for hood shape derived from the numerical and experimental results. The results of this study is supplied the important data to an industrial field for control of a pollution source in the engineering aspect. Moreover, the introduced technique of hood attached the gas-guidance-device is very useful to remove the harmful materials such as dust and waste happened in the manufacturing factory.

  • PDF

A Study ono the Type-Change of Automotive Register (차내 환기구 형상변화에 대한 연구)

  • Kim, Jong-Won;Youn, Jong-Gap;Bae, Han;Won, Sung-Pil
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.6
    • /
    • pp.123-134
    • /
    • 1999
  • Nowadays since the automobile is regarded as the third living space, comfortable conditions are required in the passenger compartment. The customer's concern on air-conditioning/heating, ventilation and demisting/defrosting performances has been much increased. Both ventilation and demisting /defrosting performances are directly influenced by register location, shape of regist guide vane, ventilation flow rate, air distribution , and air circulation pattern. Diffuse plume of air from the register is desirable not only to maintain comfort when the comfort when the comfortable condition has been satisfied but to improve demisting /defrosting performance. In this study, experimental and numerical investigation about the flow field of six different register vane types were carried out , respectively. The numerical analysis, based upon the $textsc{k}$-$\varepsilon$ turbulence model , was applied to the air flow field. The results show that the shape of register guide vane should be considered as an important design paramter.

  • PDF

A study on odor and ventilation in waste treatment facilities (폐기물 처리시설에서의 악취 및 환기에 관한 연구)

  • Seo, Byung-Suk;Jeon, Yong-Han
    • Design & Manufacturing
    • /
    • v.14 no.2
    • /
    • pp.28-33
    • /
    • 2020
  • Recently, as the income level and quality of life have improved, the desire for a pleasant environment has increased, and a deodorization plan is required through thorough prevention and diffusion of odorous substances in waste treatment facilities recognized as hateful facilities, appropriate collection, and selection of the right prevention facilities. In this study, a waste disposal facility was modeled and computerized analysis for odor and ventilation analysis was conducted. Numerical analysis of the waste treatment facility was performed at the size of the actual plant. CATIA V5 R16 for numerical model generation and ANSYS FLUENT V.13 for general purpose flow analysis were used as analysis tools. The average air-age of the internal was 329 seconds, and the air-flow velocity was 0.384m/s. The odor diffusion analysis inside the underground pump room showed congestion-free air circulation through streamline distribution and air-age distribution. This satisfies the ASHRAE criteria. In addition, the results of diffusion analysis of odorous substances such as ammonia, hydrogen sulfide, methyl mercaptan and dimethyl sulfide were all expected to satisfy the regulatory standards. Particularly in the case of the waste loading area, the air-flow velocity was 0.297m/s, and the result of meeting the regulatory standards with 0.167ppm of ammonia, 0.00548ppm of hydrogen sulfide, 0.003ppm of methyl mercaptan, and 0.003ppm of dimethyl sulfide was found.

Evaluation of Computational Fluid Dynamics for Analysis of Aerodynamics in Naturally Ventilated Multi-span Greenhouse

  • Lee, In Bok;Short, Ted H.;Sase, Sadanori;Lee, Seung Kee
    • Agricultural and Biosystems Engineering
    • /
    • v.1 no.2
    • /
    • pp.73-80
    • /
    • 2000
  • Aerodynamics in a naturally ventilated multi-span greenhouse with plants was analyzed numerically by the computational fluid dynamics (CFD) simulation. To investigate the potential application of CFD techniques to greenhouse design and analysis, the numerical results of the CFD model were compared with the results of a steady-state mass and energy balance numerical model. Assuming the results of the mass and energy balance model as the standard, reasonably good agreement was obtained between the natural ventilation rates computed by the CFD numerical model and the mass and energy balance model. The steady-state CFD model during a sunny day showed negative errors as high as 15% in the morning and comparable positive errors in the afternoon. Such errors assumed to be due to heat storage in the floor, benches, and greenhouse structure. For a west wind of 2.5 m s$^{-1}$ , the internal nonporous shading screens that opened to the east were predicted to have a 15.6% better air exchange rate than opened to the west. It was generally predicted that the presence of nonporous internal shading screens significantly reduced natural ventilation if the horizontal opening of the screen for each span was smaller that the effective roof vent opening.

  • PDF

A Study on Improvement of Industrial Hood in Ventilation System for Elimination of Harmful Material and Dust (유해물질 및 공업용 분진 제거를 위한 산업용 후드 개선에 관한 연구)

  • Kim, Young-Sun;Oh, Yool-Kwon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.4
    • /
    • pp.238-244
    • /
    • 2008
  • This study investigates on the improvement of inhalation effect of hood which attached new device named as "gas-guide-device" in local exhaust ventilation system for the effective elimination of harmful material and dust in manufacturing factory. The gas-guide-device having a diamond shape is composed of width (b) and two sides of a device (X, Y) and its size is selected the industrial hood under application in manufacturing factory after due consideration. In order to investigate the effect of gas-guide-device, numerical and experimental study is performed that the flow velocity is calculated and is measured by a commercial program "COMSOL $Multiphysics^{TM}$" and a hot wire type of anemometer, respectively. The numerical and experimental results are revealed is a similar pattern and flow velocity has improved to hood attached gas-guide-device. Also, the numerical method and result is also verified the dependance. Moreover, the optimum shape and size of gas-guide-device is revealed that the width (b) and the ratio of two sides of gas-guide-device (X, Y) has 125mm and 4 to 6.

A fundamental study on the ventilation analysis method for the network-type tunnel - focused on the none hardy-cross method (네트워크형 터널의 환기해석 방법에 대한 기초연구-비 Hardy-Cross 방법을 중심으로)

  • Kim, Hyo-Gyu;Choi, Pan-Gyu;Ryu, Ji-Oh;Lee, Chang-Woo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.3
    • /
    • pp.291-303
    • /
    • 2016
  • Recently, various forms of diverging sections in tunnels have been designed as the demand for underground passageway in urban areas increases. Therefore, the complexity of the ventilation system in tunnels with diverging sections requires a ventilation analysis method different from the conventional method for the straight tunnels. None of the domestic and foreign tunnel ventilation design standards specifies the method for the ventilation network analysis, and the numerical analysis methods have been most widely used. This paper aims at reviewing the ventilation network analytical method applicable as the design standard. The proposed method is based on the characteristic equations rather than the numerical analysis. Thanks to the advantages of easy application, the Hardy-Cross method has been widely applied in the fields of mine ventilation and tunnel ventilation. However, limitations with the cutting errors in the Taylor series expansion and the convergence problem mainly caused by the mesh selection algorithm have been reported. Therefore, this paper examines the applicability of the ventilation analysis method for network-type tunnels with the gradient method that can analyze flow rate and pressure simultaneously without the configuration of mesh. A simple ventilation analysis method for network-type tunnels is proposed.

The Study on Natural Ventilation in Working Places with the Noxious Gas and Dust (유해가스 및 분진이 발생하는 작업장내의 자연환기에 대한 연구)

  • Chu, Byung-Gil;Kim, Chul;Choi, Jong-ook;Yoo, Soo-Yul
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.1
    • /
    • pp.72-79
    • /
    • 2000
  • In recent, occupational diseases in harmful working places become a social issue. It is the well-known fact that a respiration in polluted working places exert a serious effect on health of workers. Accordingly, the cutting off contaminants air originally is the best way to improve working environments. In these cases, ventilation systems should be essentially installed to dilute or exhaust the contaminated indoor air. In this study, we investigated the characteristics of ventilation system of the noxious gas in working indoor places with natural ventilation by using COMET. The numerical simulations were carried out the natural ventilation with two phase(air, dust). For turbulent flow, Reynolds stresses were closed by the standard $\kappa$-$\varepsilon$ model. The results are as follows ; 1) In the natural exhaust in the working place, the flows of the central region have a more rapid velocity vector than the right and left one. 2) Numerical results show that the distribution of contaminants concentration have greater influence on convection than the case of diffusion by government of velocity vectors. 3) To observe the velocity variation with distance, three location of distance are considered. As results, it shows that the velocity are 0.075(m/s) at y=5(m), 10(m) and mean concentration are raised 10.6% at y=5(m), 10(m). 4) We have presented the useful data for the adequate counterplan in the harmful working places by carrying out the various investigation of the natural ventilation.