• Title/Summary/Keyword: Number of scans

Search Result 125, Processing Time 0.033 seconds

Influence of the angles and number of scans on the accuracy of 3D laser scanning (3 차원 레이저 스캔영상 채득 시 스캔각도와 횟수에 따른 정확도)

  • Lee, Kyung-Min;Song, Hyo-Young;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.41 no.2
    • /
    • pp.76-86
    • /
    • 2011
  • Objective: To investigate whether the accuracy of 3D laser scanning is influenced by the angles and number of scans. Methods: Using a 3D laser scanner, 10 manikins with facial markers were scanned at 7 horizontal angles (front view and at $20^{\circ}$, $45^{\circ}$, and $60^{\circ}$ angles on the right and left sides). Three-dimensional facial images were reconstructed by 6 methods differing in the number and angles of scans, and measurements of these images were compared to the physical measurements from the manikins. Results: The laser scan images were magnified by 0.14 - 0.26%. For images reconstructed by merging 2 scans, excluding the front view; and by merging 3 scans, including the front view and scans obtained at $20^{\circ}$ on both sides; several measurements were significantly different than the physical measurements. However, for images reconstructed by merging 3 scans, including the front view; and 5 scans, including the front view and scans obtained at $20^{\circ}$ and $60^{\circ}$ on both sides; only 1 measurement was significantly different. Conclusions: These results suggest that the number and angle of scans influence the accuracy of 3D laser scanning. A minimum of 3 scans, including the front view and scans obtained at more than $45^{\circ}$ on both sides, should be integrated to obtain accurate 3D facial images.

Cystic Lung Disease: a Comparison of Cystic Size, as Seen on Expiratory and Inspiratory HRCT Scans

  • Ki-Nam Lee;Seong-Kuk Yoon;Seok Jin Choi;Jin Mo Goo;Kyung-Jin Nam
    • Korean Journal of Radiology
    • /
    • v.1 no.2
    • /
    • pp.84-90
    • /
    • 2000
  • Objective: To determine the effects of respiration on the size of lung cysts by comparing inspiratory and expiratory high-resolution CT (HRCT) scans. Materials and Methods: The authors evaluated the size of cystic lesions, as seen on paired inspiratory and expiratory HRCT scans, in 54 patients with Langerhans cell histiocytosis (n = 3), pulmonary lymphangiomyomatosis (n = 4), confluent centrilobular emphysema (n = 9), paraseptal emphysema and bullae (n = 16), cystic bronchiectasis (n = 13), and honeycombing (n = 9). Using paired inspiratory and expiratory HRCT scans obtained at the corresponding anatomic level, a total of 270 cystic lesions were selected simultaneously on the basis of five lesions per lung disease. Changes in lung cyst size observed during respiration were assessed by two radiologists. In a limited number of cases (n = 11), pathologic specimens were obtained by open lung biopsy or lobectomy. Results: All cystic lesions in patients with Langerhans cell histiocytosis, lymphangiomyomatosis, cystic bronchiectasis, honeycombing, and confluent centrilobular emphysema became smaller on expiration, but in two cases of paraseptal emphysema and bullae there was no change. Conclusion: In cases in which expiratory CT scans indicate that cysts have become smaller, cystic lesions may communicate with the airways. To determine whether, for cysts and cystic lesions, this connection does in fact exist, paired inspiratory and expiratory HRCT scans are necessary.

  • PDF

Fiber orientation distribution of reinforced cemented Toyoura sand

  • Safdar, Muhammad;Newson, Tim;Waseem, Muhammad
    • Geomechanics and Engineering
    • /
    • v.30 no.1
    • /
    • pp.67-73
    • /
    • 2022
  • In this study, the fiber orientation distribution (FOD) is investigated using both micro-CT (computerized tomography) and image analysis of physically cut specimens prepared from Polyvinyl Alcohol (PVA) fiber reinforced cemented Toyoura sand. The micro-CT images of the fiber reinforced cemented sand specimens were visualized in horizontal and vertical sections. Scans were obtained using a frame rate of two frames and an exposure time of 500 milliseconds. The number of images was set to optimize and typically resulted in approximately 3000 images. Then, the angles of the fibers for horizontal sections and in vertical section were calculated using the VGStudio MAX software. The number of fibers intersecting horizontal and vertical sections are counted using these images. A similar approach was used for physically cut specimens. The variation of results of fiber orientation between micro-CT scans and visual count were approximately 4-8%. The micro-CT scans were able to precisely investigate the fiber orientation distribution of fibers in these samples. The results show that 85-90% of the PVA fibers are oriented between ±30° of horizontal, and approximately 95% of fibers have an orientation that lies within ±45° of the horizontal plane. Finally, a comparison of experimental results with the generalized fiber orientation distribution function 𝜌(θ) is presented for isotropic and anisotropic distribution in fiber reinforced cemented Toyoura sand specimens. Experimentally, it can be seen that the average ratio of the number of fibers intersecting the finite area on a vertical plane to number of fibers intersecting the finite area on a horizontal plane (NVtot/NHtot) cut through a sample varies from 2.08 to 2.12 (an average ratio of 2.10 is obtained in this study). Based up on the analytical predictions, it can be seen that the average NVtot/NHtot ratio varies from 2.13 to 2.17 for varying n values (an average ratio of 2.15).

Precision comparison of 3D photogrammetry scans according to the number and resolution of images

  • Park, JaeWook;Kim, YunJung;Kim, Lyoung Hui;Kwon, SoonChul;Lee, SeungHyun
    • International journal of advanced smart convergence
    • /
    • v.10 no.2
    • /
    • pp.108-122
    • /
    • 2021
  • With the development of 3D graphics software and the speed of computer hardware, it is an era that can be realistically expressed not only in movie visual effects but also in console games. In the production of such realistic 3D models, 3D scans are increasingly used because they can obtain hyper-realistic results with relatively little effort. Among the various 3D scanning methods, photogrammetry can be used only with a camera. Therefore, no additional hardware is required, so its demand is rapidly increasing. Most 3D artists shoot as many images as possible with a video camera, etc., and then calculate using all of those images. Therefore, the photogrammetry method is recognized as a task that requires a lot of memory and long hardware operation. However, research on how to obtain precise results with 3D photogrammetry scans is insufficient, and a large number of photos is being utilized, which leads to increased production time and data capacity and decreased productivity. In this study, point cloud data generated according to changes in the number and resolution of photographic images were produced, and an experiment was conducted to compare them with original data. Then, the precision was measured using the average distance value and standard deviation of each vertex of the point cloud. By comparing and analyzing the difference in the precision of the 3D photogrammetry scans according to the number and resolution of images, this paper presents a direction for obtaining the most precise and effective results to 3D artists.

National Trends in Pediatric CT Scans in South Korea: A Nationwide Cohort Study (소아 전산화단층촬영의 국내 동향: 전국적 코호트 연구)

  • Nak Tscheol Kim;Soon-Sun Kwon;Moon Seok Park;Kyoung Min Lee;Ki Hyuk Sung
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.138-148
    • /
    • 2022
  • Purpose This study evaluated the rates and annual trends of pediatric CT scans in South Korea using a nationwide population-based database. Materials and Methods Data regarding pediatric CT scan usage between 2012 and 2017 were retrieved from the health insurance review and assessment service. Data on the age, sex, diagnosis, and the anatomical area of involved patients were also extracted. Results A total of 576376 CT examinations were performed among 58527528 children aged below 18 years (9.8 scans/1000 children), and the number of CT examinations per 1000 children was noted to have increased by 23.2% from 9.0 in 2012 to 11.0 in 2017. Specifically, the number of CT examinations increased by 32.9% for the 6-12 years of age group (7.4/1000 to 9.8/1000) and by 34.0% for the 13-18 years of age group (11.4/1000 to 15.3/1000). Moreover, majority of the CT scans were limited to the head (39.1%), followed by the extremities (32.5%) and the abdomen (13.7%). Notably, the number of extremity CT scans increased by 83.6% (2.3/1000 to 4.2/1000), and its proportion as compared to other scans increased from 25.3% to 37.7%. Conclusion CT scans in the pediatric population increased continuously from 2012 to 2017 at an annual rate of 4.4%. Therefore, physicians should balance the benefits of CT with its potential harms from associated radiation exposure in pediatric patients.

Assessment of CT numbers in limited and medium field-of-view scans taken using Accuitomo 170 and Veraviewepocs 3De cone-beam computed tomography scanners

  • Oliveira, Matheus L.;Tosoni, Guilherme M.;Lindsey, David H.;Mendoza, Kristopher;Tetradis, Sotirios;Mallya, Sanjay M.
    • Imaging Science in Dentistry
    • /
    • v.44 no.4
    • /
    • pp.279-285
    • /
    • 2014
  • Purpose: To assess the influence of anatomic location on the relationship between computed tomography (CT) number and X-ray attenuation in limited and medium field-of-view (FOV) scans. Materials and Methods: Tubes containing solutions with different concentrations of $K_2HPO_4$ were placed in the tooth sockets of a human head phantom. Cone-beam computed tomography (CBCT) scans were acquired, and CT numbers of the $K_2HPO_4$ solutions were measured. The relationship between CT number and $K_2HPO_4$ concentration was examined by linear regression analyses. Then, the variation in CT number according to anatomic location was examined. Results: The relationship between $K_2HPO_4$ concentration and CT number was strongly linear. The slopes of the linear regressions for the limited FOVs were almost 2-fold lower than those for the medium FOVs. The absolute CT number differed between imaging protocols and anatomic locations. Conclusion: There is a strong linear relationship between X-ray attenuation and CT number. The specific imaging protocol and anatomic location of the object strongly influence this relationship.

Quantitative Analysis of Factors Affecting Cobalt Alloy Clip Artifacts in Computed Tomography

  • Sim, Sook Young;Choi, Chi Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.5
    • /
    • pp.400-404
    • /
    • 2014
  • Objective : Clip artifacts limit the visualization of intracranial structures in CT scans from patients after aneurysmal clipping with cobalt alloy clips. This study is to analyze the parameters influencing the degree of clip artifacts. Methods : Postoperative CT scans of 60 patients with straight cobalt alloy-clipped aneurysms were analyzed for the maximal diameter of white artifacts and the angle and number of streak artifacts in axial images, and the maximal diameter of artifacts in three-dimensional (3-D) volume-rendered images. The correlation coefficient (CC) was determined between each clip artifact type and the clip blade length and clip orientation to the CT scan (angle a, lateral clip inclination in axial images; angle b, clip gradient to scan plane in lateral scout images). Results : Angle b correlated negatively with white artifacts (r=-0.589, p<0.001) and positively with the angle (r=0.636, p<0.001) and number (r=0.505, p<0.001) of streak artifacts. Artifacts in 3-D images correlated with clip blade length (r=0.454, p=0.004). Multiple linear regression analysis revealed that angle b was the major parameter influencing white artifacts and the angle and number of streak artifacts in axial images (p<0.001), whereas clip blade length was a major factor in 3-D images (p=0.034). Conclusion : Use of a clip orientation perpendicular to the scan gantry angle decreased the amount of white artifacts and allowed better visualization of the clip site.

$^{99m}Tc$-DMSA Scintigram for Renal Function Recovery after Therapy in Infants and Children (유소아 신질환에서 치료후 신기능회복에 대한 $^{99m}Tc$-DMSA 신티그램의 임상적 고찰)

  • Moon, Tae-Yong;Son, Hyun-Ju;Kim, In-Ju;Yoon, Chong-Byung;Lee, Suck-Hong;Kim, Byung-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.69-74
    • /
    • 1994
  • Authors retrospectively analysed 20 cases of follow-up $^{99m}Tc$-DMSA renal scans to evaluate renal function recovery after treatment in urologic disorders of infants and children. There were 20 cases with both $^{99m}Tc$-DMSA renal scans prior to and after therapy in 15 patients below 9 years old. Among them, 10 patients underwent ureteroneocystostomy under the diagnosis of vesicoureteral reflux, two patients pyeloplasty because of obstructive uropathy and one was treated with antibiotics even diagnosis of UPJ stricture. We have got the quantified uptake rate of $^{99m}Tc$-DMSA renal scan by using the regression equation as "y=0.591x-2.105" (y=the quantified uptake rate, x=the simple uptake rate). The number of kidneys performed proper therapy were 29, and the cases with more increased radiotracer uptake rate in the follow-up $^{99m}Tc$-DMSA renal scans were 20 in number as 69% in frequency. 19 cases with improved renal function on $^{99m}Tc$-DMSA renal scans didn't show any significant difference related to aging or recovery duration after therapy. The $^{99m}Tc$-DMSA renal scans were not useful to evaluate renal function recovery in infants and children, but could be good tests to assess residual renal function prior to or after treatment.

  • PDF

Comparative Analysis of Understanding and Satisfaction of MRI Patients after Leaflet Training (리플릿 교육 후 MRI 환자의 이해도 및 만족도 비교분석)

  • Park, Chang-Hee;Han, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.123-129
    • /
    • 2022
  • Recently, the penetration rate of Magnetic Resonance Imaging (MRI) is higher than the average among OECD member countries, and the number of MRI scans is increasing. However, MRI scans take longer than other medical devices, and patient movement must be minimized. Therefore, patient discomfort always follows. When the examination is performed in the discomfort of the patient, it is difficult to perform an accurate examination, and it is difficult to obtain an image of diagnostic value. So, in the past, the patient was asked to read the written guide for the risk and cooperation of MRI, but it was composed of technical terms and difficult-to-understand sentences, so it was difficult to understand. The purpose of this study is to supplement these problems and increase the understanding of MRI scans to help acquire images of diagnostic value. In addition, it is intended to evaluate the excellence of leaflet education by evaluating the understanding and satisfaction of patients. As shown in the results of this study, understanding and satisfaction scores were higher after education than before leaflet education, and it was found that there was a difference in understanding according to academic background. However, there was no difference in the number of MRI scans. That is, there was no difference in the number of inspections due to leaflet education. In the future, leaflet education will be widely used for MRI examination, and it is necessary to study the qualitative evaluation of images after leaflet education in the future.

Fabrication of Titanium Microchannels by using Ar+ Laser-assited Wet Etching (레이저 유도에칭을 이용한 티타늄 미세채널 제조)

  • 손승우;이민규;정성호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.709-713
    • /
    • 2004
  • Characteristics of laser-assisted wet etching of titanium in phosphoric acid were investigated to examine the feasibility of this method for fabrication of high aspect ratio microchannels. Laser power, number of scans, etchant concentration, position of beam waist and scanning speed were taken into consideration as the major process parameters exerting the temperature distribution and the cross sectional profile of etched channels. Experimental results indicated that laser power influences on both etch width and depth while number of scans and scanning speed mainly affect on the etch depth. At a low etchant concentration, the cross sectional profile of an etched channel becomes a U-shape but it gradually turns into a V-shape as the concentration increases. On the other hand, surface of the laser beam focus with respect to the sample surface is found to be a key factor determining the bubble dynamics and thus the process stability. It is demonstrated that metallic microchannels with different cross sectional profiles can be fabricated by properly controlling the process parameters. Microchannels of aspect ratio up to 8 with the width and depth ranges of 8∼32 m and 50∼300 m, respectively, were fabricated.

  • PDF