• Title/Summary/Keyword: Nuclear safety analysis code

Search Result 388, Processing Time 0.018 seconds

DEVELOPMENT OF THE SPACE CODE FOR NUCLEAR POWER PLANTS

  • Ha, Sang-Jun;Park, Chan-Eok;Kim, Kyung-Doo;Ban, Chang-Hwan
    • Nuclear Engineering and Technology
    • /
    • v.43 no.1
    • /
    • pp.45-62
    • /
    • 2011
  • The Korean nuclear industry is developing a thermal-hydraulic analysis code for safety analysis of pressurized water reactors (PWRs). The new code is called the Safety and Performance Analysis Code for Nuclear Power Plants (SPACE). The SPACE code adopts advanced physical modeling of two-phase flows, mainly two-fluid three-field models which comprise gas, continuous liquid, and droplet fields and has the capability to simulate 3D effects by the use of structured and/or nonstructured meshes. The programming language for the SPACE code is C++ for object-oriented code architecture. The SPACE code will replace outdated vendor supplied codes and will be used for the safety analysis of operating PWRs and the design of advanced reactors. This paper describes the overall features of the SPACE code and shows the code assessment results for several conceptual and separate effect test problems.

Application of data driven modeling and sensitivity analysis of constitutive equations for improving nuclear power plant safety analysis code

  • ChoHwan Oh;Doh Hyeon Kim;Jeong Ik Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.131-143
    • /
    • 2023
  • Constitutive equations in a nuclear reactor safety analysis code are mostly empirical correlations developed from experiments, which always accompany uncertainties. The accuracy of the code can be improved by modifying the constitutive equations fitting wider range of data with less uncertainty. Thus, the sensitivity of the code with respect to the constitutive equations is evaluated quantitatively in the paper to understand the room for improvement of the code. A new methodology is proposed which first starts by dividing the thermal hydraulic conditions into multiple sub-regimes using self-organizing map (SOM) clustering method. The sensitivity analysis is then conducted by multiplying an arbitrary set of coefficients to the constitutive equations for each sub-divided thermal-hydraulic regime with SOM to observe how the code accuracy varies. The randomly chosen multiplier coefficient represents the uncertainty of the constitutive equations. Furthermore, the set with the smallest error with the selected experimental data can be obtained and can provide insight which direction should the constitutive equations be modified to improve the code accuracy. The newly proposed method is applied to a steady-state experiment and a transient experiment to illustrate how the method can provide insight to the code developer.

Simplified elastic-plastic analysis procedure for strain-based fatigue assessment of nuclear safety class 1 components under severe seismic loads

  • Kim, Jong-Sung;Kim, Jun-Young
    • Nuclear Engineering and Technology
    • /
    • v.52 no.12
    • /
    • pp.2918-2927
    • /
    • 2020
  • This paper proposes a simplified elastic-plastic analysis procedure using the penalty factors presented in the Code Case N-779 for strain-based fatigue assessment of nuclear safety class 1 components under severe seismic loads such as safety shutdown earthquake and beyond design-basis earthquake. First, a simplified elastic-plastic analysis procedure for strain-based fatigue assessment of nuclear safety class 1 components under the severe seismic loads was proposed based on the analysis result for the simplified elastic-plastic analysis procedure in the Code Case N-779 and the stress categories corresponding to normal operation and seismic loads. Second, total strain amplitude was calculated directly by performing finite element cyclic elastic-plastic seismic analysis for a hot leg nozzle in pressurizer surge line subject to combined loading including deadweight, pressure, seismic inertia load, and seismic anchor motion, as well as was derived indirectly by applying the proposed analysis procedure to the finite element elastic stress analysis result for each load. Third, strain-based fatigue assessment was implemented by applying the strain-based fatigue acceptance criteria in the ASME B&PV Code, Sec. III, Subsec. NB, Article NB-3200 and by using the total strain amplitude values calculated. Last, the total strain amplitude and the fatigue assessment result corresponding to the simplified elastic-plastic analysis were compared with those using the finite element elastic-plastic seismic analysis results. As a result of the comparison, it was identified that the proposed analysis procedure can derive reasonable and conservative results.

Verification of SPACE Code with MSGTR-PAFS Accident Experiment (증기발생기 전열관 다중파단-피동보조급수냉각계통 사고 실험 기반 안전해석코드 SPACE 검증)

  • Nam, Kyung Ho;Kim, Tae Woo
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.4
    • /
    • pp.84-91
    • /
    • 2020
  • The Korean nuclear industry developed the SPACE (Safety and Performance Analysis Code for nuclear power plants) code and this code adpots two-phase flows, two-fluid, three-field models which are comprised of gas, continuous liquid and droplet fields and has a capability to simulate three-dimensional model. According to the revised law by the Nuclear Safety and Security Commission (NSSC) in Korea, the multiple failure accidents that must be considered for accident management plan of nuclear power plant was determined based on the lessons learned from the Fukushima accident. Generally, to improve the reliability of the calculation results of a safety analysis code, verification work for separate and integral effect experiments is required. In this reason, the goal of this work is to verify calculation capability of SPACE code for multiple failure accident. For this purpose, it was selected the experiment which was conducted to simulate a Multiple Steam Generator Tube Rupture(MSGTR) accident with Passive Auxiliary Feedwater System(PAFS) operation by Korea Atomic Energy Research Institute (KAERI) and focused that the comparison between the experiment results and code calculation results to verify the performance of the SPACE code. The MSGR accident has a unique feature of the penetration of the barrier between the Reactor Coolant System (RCS) and the secondary system resulting from multiple failure of steam generator U-tubes. The PAFS is one of the advanced safety features with passive cooling system to replace a conventional active auxiliary feedwater system. This system is passively capable of condensing steam generated in steam generator and feeding the condensed water to the steam generator by gravity. As the results of overall system transient response using SPACE code showed similar trends with the experimental results such as the system pressure, mass flow rate, and collapsed water level in component. In conclusion, it could be concluded that the SPACE code has sufficient capability to simulate a MSGTR accident.

Evaluation of SPACE Code Prediction Capability for CEDM Nozzle Break Experiment with Safety Injection Failure (안전주입 실패를 동반한 제어봉구동장치 관통부 파단 사고 실험 기반 국내 안전해석코드 SPACE 예측 능력 평가)

  • Nam, Kyung Ho
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.5
    • /
    • pp.80-88
    • /
    • 2022
  • The Korean nuclear industry had developed the SPACE (Safety and Performance Analysis Code for nuclear power plants) code, which adopts a two-fluid, three-field model that is comprised of gas, continuous liquid and droplet fields and has the capability to simulate three-dimensional models. According to the revised law by the Nuclear Safety and Security Commission (NSSC) in Korea, the multiple failure accidents that must be considered for the accident management plan of a nuclear power plant was determined based on the lessons learned from the Fukushima accident. Generally, to improve the reliability of the calculation results of a safety analysis code, verification is required for the separate and integral effect experiments. Therefore, the goal of this work is to verify the calculation capability of the SPACE code for multiple failure accidents. For this purpose, an experiment was conducted to simulate a Control Element Drive Mechanism (CEDM) break with a safety injection failure using the ATLAS test facility, which is operated by Korea Atomic Energy Research Institute (KAERI). This experiment focused on the comparison between the experiment results and code calculation results to verify the performance of the SPACE code. The results of the overall system transient response using the SPACE code showed similar trends with the experimental results for parameters such as the system pressure, mass flow rate, and collapsed water level in component. In conclusion, it can be concluded that the SPACE code has sufficient capability to simulate a CEDM break with a safety injection failure accident.

Application of a combined safety approach for the evaluation of safety margin during a Loss of Condenser Vacuum event

  • Shin, Dong-Hun;Jeong, Hae-Yong;Park, Moon-Ghu;Sohn, Jung-Uk
    • Nuclear Engineering and Technology
    • /
    • v.54 no.5
    • /
    • pp.1698-1711
    • /
    • 2022
  • A combined safety approach, which uses a best-estimate computer code and adopts conservative assumptions for safety systems availability, is developed and applied to the safety margin evaluation for the Loss of Condenser Vacuum (LOCV) of the 1000 MWe Korean Nuclear Power Plant. The Multi-dimensional Analysis of Reactor Safety-KINS standard (MARS-KS) code is selected as a best-estimate code and the PAPIRUS program is used to obtain different initial operational conditions through random sampling of control variables. During an LOCV event, fuel integrity is not threatened by the increase in Departure from Nuclear Boiling Ratio (DNBR). However, the high pressure in the primary coolant system and the secondary system might affect the system integrity. Thus, the peak pressure becomes a major safety concern. Transient analyses are performed for 124 cases of different initial conditions and the most conservative case, which results in the highest system pressure is selected. It is found the suggested methodology gives similar peak pressures when compared to those predicted from existing methodologies. The proposed approach is expected to minimize the time and efforts required to identify the conservative plant conditions in the existing conservative safety methodologies.

Analysis of the performances of the CFD schemes used for coupling computation

  • Chen, Guangliang;Jiang, Hongwei;Kang, Huilun;Ma, Rui;Li, Lei;Yu, Yang;Li, Xiaochang
    • Nuclear Engineering and Technology
    • /
    • v.53 no.7
    • /
    • pp.2162-2173
    • /
    • 2021
  • In this paper, the coupling of fine-mesh computational fluid dynamics (CFD) thermal-hydraulics (TH) code and neutronics code is achieved using the Ansys Fluent User Defined Function (UDF) for code development, including parallel meshing mapping, data computation, and data transfer. Also, some CFD schemes are designed for mesh mapping and data transfer to guarantee physical conservation in the coupling computation. Because there is no rigorous research that gives robust guidance on the various CFD schemes that must be obtained before the fine-mesh coupling computation, this work presents a quantitative analysis of the CFD meshing and mapping schemes to improve the accuracy of the value and location of key physical prediction. Furthermore, the effect of the sub-pin scale coupling computation is also studied. It is observed that even the pin-resolved coupling computation can also create a large deviation in the maximum value and spatial locations, which also proves the significance of the research on mesh mapping and data transfer for CFD code in a coupling computation.

Development and validation of FRAT code for coated particle fuel failure analysis

  • Jian Li;Ding She;Lei Shi;Jun Sun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4049-4061
    • /
    • 2022
  • TRISO-coated particle fuel is widely used in high temperature gas cooled reactors and other advanced reactors. The performance of coated fuel particle is one of the fundamental bases of reactor safety. The failure probability of coated fuel particle should be evaluated and determined through suitable fuel performance models and methods during normal and accident condition. In order to better facilitate the design of coated particle fuel, a new TRISO fuel performance code named FRAT (Fission product Release Analysis Tool) was developed. FRAT is designed to calculate internal gas pressure, mechanical stress and failure probability of a coated fuel particle. In this paper, FRAT was introduced and benchmarked against IAEA CRP-6 benchmark cases for coated particle failure analysis. FRAT's results agree well with benchmark values, showing the correctness and satisfactory applicability. This work helps to provide a foundation for the credible application of FRAT.

APPLICATIONS OF INTEGRATED SAFETY ANALYSIS METHODOLOGY TO RELOAD SAFETY EVALUATION

  • Jang, Chan-Su;Um, Kil-Sup
    • Nuclear Engineering and Technology
    • /
    • v.43 no.2
    • /
    • pp.187-194
    • /
    • 2011
  • Korea Nuclear Fuel is developing the X-GEN fuel which shows high performance and robust reliability for the worldwide supply. However, the simplified code systems such as CESEC-III which were developed in 1970s are still used in the current Non-LOCA safety analysis of OPR1000 and APR1400 plants. Therefore, it is essential to secure an advanced safety analysis methodology to make the best use of the merits of X-GEN fuel. To accomplish this purpose, the $\b{i}$ntegrated $\b{s}$afety $\b{a}$nalysis $\b{m}$ethodology (iSAM), is developed by selecting the best-estimate thermal-hydraulic code RETRAN. iSAM possesses remarkable advantages, such as generality, integrity, and designer-friendly features. That is, iSAM can be applied to both OPR1000 and APR1400 plants and uses only one computer code, RETRAN, in the whole scope of the non-LOCA safety analyses. Also the iSAM adopts the unique and automatic initialization and run tool, $\b{a}$utomatic $\b{s}$teady-$\b{s}$tate $\b{i}$nitialization and $\b{s}$afety analysis too l (ASSIST), to enable unhandy designers to use the new design code RETRAN without difficulty. In this paper, a brief overview of the iSAM is given, and the results of applying the iSAM to typical non-LOCA transients being checked during the reload design are reported. The typical non-LOCA transients selected are the single control element assembly withdrawal (SCEAW) accident, the asymmetric steam generator transients (ASGT), the locked rotor (LR) accident, and bank CEA withdrawal (BCEAW) event. Comparison to current licensing results shows a close resemblance; thus, it reveals that the iSAM can be applied to the non-LOCA safety analysis of OPR1000 and APR1400 plants.

Development of Web-based Off-site Consequence Analysis Program and its Application for ILRT Extension (격납건물종합누설률시험 주기연장을 위한 웹기반 소외결말분석 프로그램 개발 및 적용)

  • Na, Jang-Hwan;Hwang, Seok-Won;Oh, Ji-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.5
    • /
    • pp.219-223
    • /
    • 2012
  • For an off-site consequence analysis at nuclear power plant, MELCOR Accident Consequence Code System(MACCS) II code is widely used as a software tool. In this study, the algorithm of web-based off-site consequence analysis program(OSCAP) using the MACCS II code was developed for an Integrated Leak Rate Test (ILRT) interval extension and Level 3 probabilistic safety assessment(PSA), and verification and validation(V&V) of the program was performed. The main input data for the MACCS II code are meteorological, population distribution and source term information. However, it requires lots of time and efforts to generate the main input data for an off-site consequence analysis using the MACCS II code. For example, the meteorological data are collected from each nuclear power site in real time, but the formats of the raw data collected are different from each site. To reduce the efforts and time for risk assessments, the web-based OSCAP has an automatic processing module which converts the format of the raw data collected from each site to the input data format of the MACCS II code. The program also provides an automatic function of converting the latest population data from Statistics Korea, the National Statistical Office, to the population distribution input data format of the MACCS II code. For the source term data, the program includes the release fraction of each source term category resulting from modular accident analysis program(MAAP) code analysis and the core inventory data from ORIGEN. These analysis results of each plant in Korea are stored in a database module of the web-based OSCAP, so the user can select the defaulted source term data of each plant without handling source term input data.