• Title/Summary/Keyword: Nuclear medicine imaging

Search Result 1,089, Processing Time 0.024 seconds

The Effect of Caffeic Acid Phenethyl Ester (CAPE) on Phagocytic activity of septic Neutrophil in vitro

  • Eun-A Jang;Hui-Jing Han;Tran Duc Tin;Eunye Cho;Seongheon Lee;Sang Hyun Kwak
    • Biomedical Science Letters
    • /
    • v.29 no.4
    • /
    • pp.211-219
    • /
    • 2023
  • Caffeic acid phenethyl ester (CAPE) is an active component of propolis obtained from honeybee hives. CAPE possesses anti-mitogenic, anti-carcinogenic, anti-inflammatory, and immunomodulatory activities in diverse systems, which know as displays antioxidant activity and inhibits lipoxygenase activities, protein tyrosine kinase, and nuclear factor kappa B (NF-κB) activation. This study aimed to investigate the effect of CAPE on lipopolysaccharide (LPS)-induced human neutrophil phagocytosis. Human neutrophils were cultured with various concentrations of CAPE (1, 10, and 100 µM) with or without LPS. The pro-inflammatory proteins (tumor necrosis factor-alpha [TNF-α], interleukin [IL]-6 and IL-8) levels were measured after 4 h incubation. To investigate the intracellular signaling pathway, we measured the levels of mitogen-activated protein kinases (MAPK), including phosphorylation of p38, extracellular signal-regulated protein kinases 1 and 2 (ERK1/2) and c-Jun N-terminal kinase (JNK). Next, to evaluate the potential phagocytosis, neutrophils were labeled with iron particles of superparamagnetic iron oxide nanoparticles (SPIONs, 40 nm) for 1 h in culture medium containing 5 mg/mL of iron. The labeling efficiency was determined by Prussian blue staining for intracellular iron and 3T-wighted magnetic resonance imaging. CAPE decreased the activation of intracellular signaling pathways, including ERK1/2 and c-Jun, and expression of pro-inflammatory cytokines, including TNF-α and IL-6, but had no effect on the signaling pathways of p38 and cytokine IL-8. Furthermore, images obtained after mannan-coated SPION treatment suggested that CAPE induced significantly higher signal intensities than the control or LPS group. Together, these results suggest that CAPE regulates LPS-mediated activation of human neutrophils to reduce phagocytosis.

A Study on analysis of contrasts and variation in SUV with the passage of uptake time in 18F-FDOPA Brain PET/CT (18F-FDOPA Brain PET/CT 검사의 영상 대조도 분석 및 섭취 시간에 따른 SUV변화 고찰)

  • Seo, Kang rok;Lee, Jeong eun;Ko, Hyun soo;Ryu, Jae kwang;Nam, Ki pyo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.69-74
    • /
    • 2019
  • Purpose $^{18}F$-FDOPA using amino acid is particularly attractive for imaging of brain tumors because of the high uptake in tumor tissue and the low uptake in normal brain tissue. But, on the other hand, $^{18}F$-FDG is highly uptake in both tumor tissue and normal brain tissue. The purpose of study is to evaluate comparison of contrasts in $^{18}F$-FDOPA Brain PET/CT and $^{18}F$-FDG Brain PET/CT and to find out optimal scan time by analysis of variation in SUV with the passage of uptake time. Materials and Methods A region of interest of approximately $350mm^2$ at the center of the tumor and cerebellum in 12 patients ($51.4{\pm}12.8yrs$) who $^{18}F$-FDG Brain PET/CT and $^{18}F$-FDOPA Brain PET/CT were examined more than once each. The $SUV_{max}$ was measured, and the $SUV_{max}$ ratio (T/C ratio) of the tumor cerebellum was calculated. In the analysis of SUV, T/C ratio was calculated for each frame after dividing into 15 frames of 2 minutes each using List mode data in 25 patients ($49.{\pm}10.3yrs$). SPSS 21 was used to compare T/C ratio of $^{18}F$-FDOPA and T/C ratio of $^{18}F$-FDG. Results The T/C ratio of $^{18}F$-FDOPA Brain PET/CT was higher than the T/C ratio of $^{18}F$-FDG Brain, and show a significant difference according to a paired t-test(t=-5.214, p=0.000). As a result of analyzing changes in $SUV_{max}$ and T/C ratio, the peak point of $SUV_{max}$ was $5.6{\pm}2.9$ and appeared in the fourth frame (6 to 8 minutes), and the peak of T/C ratio also appeared in the fourth frame (6 to 8 minutes). Taking this into consideration and comparing the existing 10 to 30 minutes image and 6 to 26 minutes image, the $SUV_{max}$ and T/C ratio increased by 0.2 and 0.1 each, compared to the 10 to 30 minutes image for 6 to 26 minutes image. Conclusion From this study, $^{18}F$-FDOPA Brain PET/CT is effective when reading the image, because the T/C ratio of $^{18}F$-FDOPA Brain PET/CT was higher than T/C ratio of $^{18}F$-FDG Brain PET/CT. In addition, in the case of $^{18}F$-FDOPA Brain PET/CT, there was no difference between the existing 10 to 30 minutes image and 6 to 26 minutes image. Through continuous research, we can find possibility of shortening examination time in $^{18}F$-FDOPA Brain PET/CT. Also, we can help physician to accurate reading using additional scan data.

Head Motion Detection and Alarm System during MRI scanning (MRI 영상획득 중의 피험자 움직임 감지 및 알림 시스템)

  • Pae, Chong-Won;Park, Hae-Jeong;Kim, Dae-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.1
    • /
    • pp.55-66
    • /
    • 2012
  • Purpose : During brain MRI scanning, subject's head motion can adversely affect MRI images. To minimize MR image distortion by head movement, we developed an optical tracking system to detect the 3-D movement of subjects. Materials and Methods: The system consisted of 2 CCD cameras, two infrared illuminators, reflective sphere-type markers, and frame grabber with desktop PC. Using calibration which is the procedure to calculate intrinsic/extrinsic parameters of each camera and triangulation, the system was desiged to detect 3-D coordinates of subject's head movement. We evaluated the accuracy of 3-D position of reflective markers on both test board and the real MRI scans. Results: The stereo system computed the 3-D position of markers accurately for the test board and for the subject with glasses with attached optical reflective marker, required to make regular head motion during MRI scanning. This head motion tracking didn't affect the resulting MR images even in the environment varying magnetic gradient and several RF pulses. Conclusion: This system has an advantage to detect subject's head motion in real-time. Using the developed system, MRI operator is able to determine whether he/she should stop or intervene in MRI acquisition to prevent more image distortions.

Quantitative Analysis of Thallium-201 Scintigraphy in Bone Tumor (골종양에서 탈륨 스캔의 정량적 분석)

  • Shin, Duk-Seop;Cho, Ihn-Ho
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.9 no.1
    • /
    • pp.45-51
    • /
    • 2003
  • Purpose: This study was designed to know the ability of thallium-201 scintigraphy to discriminate malignant bone tumor from benign by analysing the quantitative thallium uptake ratio. Materials and Methods: We took thallium-201 scintigraphy prospectively with other imaging studies in 82 bone tumor suspecting patients. The results of scintigraphy were read qualitatively and calculated quantitatively, and retention indexes were estimated. For the statistical analysis the patients were divided as four group; high grade malignant bone tumor, benign bone tumor, giant cell tumor and low grade malignant bone tumor. Results: The mean thallium uptake ratio was 4.14 in early phase and 2.26 in delayed phase in high grade malignant bone tumor group, 1.16 and 1.09 in benign bone tumor, 3.15 and 1.94 in giant cell tumor, and 1.41 and 1.31 in low grade malignant bone tumor. Retention indexes were 0.62, 0.97, 0.66, 0.93 in same order. The thallium uptake ratio and retention indexes were statistically correlated in high grade malignant bone tumor and benign bone tumor group(p<0.001). Conclusion: Thallium-201 scintigraphy proved as useful imaging study to discriminate malignant bone tumor from benign, but had exception in giant cell tumor and low grade malignant bone tumors.

  • PDF

A Study Regarding Measurements of Bacterial Contamination Levels in Radiology Room Equipment (방사선과 촬영실 장비의 세균오염도 측정)

  • Choi, Eun-Jin;Song, Hyeon-Je;Dong, Kyung-Rae;Kim, Chang-Bok;Ryu, Jae-Kwang;Kwak, Jong-Gil
    • Journal of Radiation Industry
    • /
    • v.11 no.1
    • /
    • pp.1-6
    • /
    • 2017
  • Reported some level of bacteria in areas that are well made contact in Radiology imaging room evaluate the importance of cleanliness in the hospital management of equipment to check for the presence of pathogenic bacteria. Gwang-ju and Jeol-la city and medium-sized hospitals in the material with a cotton swab and rub evenly Radiology selection cassette, a handle, Apron of the imaging apparatus having the most contact with patients from July 2016 to August 2016 as a target in place and special studios 6, and saline solution will placed in a test tube containing. The swab sample was diluted 1,000 times, you can see the bacteria and the intestinal bacterial selective medium Trypticase Soy Agar (TSA), Muller-Hinton Agar (MHA), Eosin-Methylene Blue (EMB), ENDO(BD, NJ, USA) then incubated smear to. In the incubator (incubator, SANYO, Japan) was observed after incubation of bacteria and counting the total number of bacteria also Colonies (colony) suspected intestinal bacteria were isolated and cultured on KIA medium (BD, NJ, USA). As a result, it was found that this came Gram positive Coccus A hospital handle the F hospital, from the C Gram positive Coccus cassette and handle the F hospital. The striking yellow coloring Staphylococcus aureus 110 agar (STA 110) in the medium sample, but it is suspected staphylococcal Coccus to the final identification in the laboratory is not a single specimen of the two samples from Gram positive Coccus biochemical identification Identification Kit is an API could not, it was thought to be non-Staphylococcus aureus was cultured on blood agar suggesting that (BAP) blood of dance. Dynamic tests were conducted biochemical API kit of the two samples were identified from Gram positive Coccus bacteria Escherichia coli (E. coli) is F hospital cassette was confirmed Eenterobacter cloaca in A hospital possession. Did not aggregate O-26, O-111, O-157 and the serum test was conducted in the laboratory from the E. coli F cassette hospital.

The Development of Iodine-123 with MC-50 Cyclotron (MC-50 싸이클로트론을 이용한 $^{123}I$ 제법 연구)

  • Suh, Yong-Sup;Yang, Seung-Tae;Chun, Kown-Soo;Lee, Jong-Doo;Han, Hyon-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.286-293
    • /
    • 1991
  • $^{123}I$, which is applied for the thyroid and other in vivo kinetic study, has a special role in life sciences. The 159 KeV $\gamma-ray$ from $^{123}I$ is almost ideally appropriate for the current imaging instrumentation. Its decay mode (electron capture) and short half-life (13.3 hr) reduced the burden of radiation dose to the patients, and its chemical property makes it easy to synthesize the labelling compounds. In this experiment, the production of $^{123}I$ via the nuclear reaction $^{124}Te(p,2n)^{123}I$ with 28 MeV protons was sutdied. $TeO_2$ is used as a target material, because it has good physical properties. The target was prepared with $TeO_2$ powder and was molten into a ellipsoidal cavity (a=14 mm, b=10 mm, $270.8mg/cm^2$ thick) of pure platinum. The irradiation was carried out in the external proton beam with incident energies range from 28 MeV to 22 MeV, and current was $30{\mu}A$. The loss of $TeO_2$ target was significantly reduced by using $4\pi-cooling$ system in irradiation. The dry distillation method was adopted for the separation of $^{123}I$ from irradiated target, and when it was kept 5 minutes at $780^{\circ}C$, its result was quantitative. The loss of the target material $(TeO_2)$ was below 0.2% for each production run and $^{123}I$ from the dry distillation apparatus was captured with 0.01 N NaOH in $Na^{123}I$ form, then the pH of the solution was adjusted to $7.5\sim9.0$ with HC1/NaOH. The $Na^{123}I$ solution was passed through $0.2{\mu}m$ membrane filter, and sterilized under high pressure and temperature for 30 minutes. The production of $^{123}I$ is acceptable for clinical application based on the quality of USP XXI.

  • PDF

Gold Nanoparticles Coated with Gd-Chelate as a Potential CT/MRI Bimodal Contrast Agent

  • Sk Md., Nasiruzzaman;Kim, Hee-Kyung;Park, Ji-Ae;Chang, Yong-Min;Kim, Tae-Jeong
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.5
    • /
    • pp.1177-1181
    • /
    • 2010
  • The synthesis and characterization of gold nanoparticles coated by Gd-chelate (GdL@Au) is described, where L is a conjugate of DTPA (DTPA = diethylenetriamine-N,N,N',N",N"-pentaacetic acid) and 4-aminothiophenol. These particles are obtained by the replacement of citrate from the gold nanoparticle surfaces with gadolinium chelate (GdL). The average size of GdL@Au is 12 nm with a loading of GdL reaching up to $1.4{\times}10^3$ per particles, and they demonstrate very high r1 relaxivity (${\sim}10^4mM^{-1}s^{-1}$) and the r1 relaxivity per [Gd] is as high as $10mM^{-1}s{-1}$. Here, we also describe the use of bimodality of this contrast agent (CA) as a highly efficient CT contrast agent based on gold nanoparticles (GNPs) that overcome the limitations of iodine based contrast agent. The MTT assay performed on this CAs reveals the cytotoxicity as low as that for Omniscan$^{(R)}$ in the concentration range required to obtain intensity enhancement in the in vivo MRI study.

Multiple Inputs Deep Neural Networks for Bone Age Estimation Using Whole-Body Bone Scintigraphy

  • Nguyen, Phap Do Cong;Baek, Eu-Tteum;Yang, Hyung-Jeong;Kim, Soo-Hyung;Kang, Sae-Ryung;Min, Jung-Joon
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.12
    • /
    • pp.1376-1384
    • /
    • 2019
  • The cosmetic and behavioral aspects of aging have become increasingly evident over the years. Physical aging in people can easily be observed on their face, posture, voice, and gait. In contrast, bone aging only becomes apparent once significant bone degeneration manifests through degenerative bone diseases. Therefore, a more accurate and timely assessment of bone aging is needed so that the determinants and its mechanisms can be more effectively identified and ultimately optimized. This study proposed a deep learning approach to assess the bone age of an adult using whole-body bone scintigraphy. The proposed approach uses multiple inputs deep neural network architectures using a loss function, called mean-variance loss. The data set was collected from Chonnam National University Hwasun Hospital. The experiment results show the effectiveness of the proposed method with a mean absolute error of 3.40 years.

A Study on Radiologic Technologist's License System and Primary Pathway Education Curriculum in the United States American : Focused on One Case of College in Texas (미국 방사선사 면허제도와 기본 교육과정에 대한 고찰 : 텍사스주 일개 대학 사례를 중심으로)

  • Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.43 no.1
    • /
    • pp.35-43
    • /
    • 2020
  • The purpose of this study was to study on radiologic technologist's license system and primary pathway education curriculum in the United States American (USA), focused on one case of college in Texas. We were collected and analyzed through class participation at a community college in Tarrant, interviews with professors of radiologic science and clinical radiographers, field trips, an internet search, and literature reviews. As a result, first, the American radiologic technologists license system is composed of fifteen chapters, and the professional education courses for each field are being carried out through three courses of a primary pathway, a post primary pathway and a physician extender. Second, the primary pathway courses consisted the radiography, the radiation therapy, the nuclear medicine, the magnetic resonance imaging, the sonography. Third, the USA had about 30 times more clinical practice time than Korea. In clinical practice, students had done actually examination through X-ray exposure on patients. Last radiographers in the USA was able to perform intravenous injection of radiopharmaceutical agents on patient, so that he could perform rapid examination and efficient manpower operation. This study could be used as basic data for the globalization of radiologic technologists license system in Korea.

Squamous Cell Carcinoma In Palatal Gingiva. A Case Report (상악 구개부 치은에 발생한 편평상피세포암의 증례보고)

  • Kim, Ok-Su;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.1
    • /
    • pp.309-316
    • /
    • 1996
  • Squamous cell carcinoma is the most common malignant tumor of the gingiva. Oral cancer accounts for 5 percent of all malignant tumors in the body, and 6 percent of these occur in the gingiva. We present one case of squamous cell carcinoma of the gingiva in 23-year-old female. She complained of gingival swelling and pain during mastication between left maxillary first molar and second molar. Since she had received scaling 2 years ago, food impaction occurred frequently in this site and an ulcerative lesion recurred several times. When she was referred from local clinic, she had a large, irregularly ulcerated lesion of palatal gingiva between left maxillary first molar and second molar, accompanying induration in center and slight elevation around ulcerative margin. The etiology could not be defined but we could diagnose by careful history taking and excisional biopsy of the recurrent ulcerative lesion. In addition, computed tomography and nuclear medicine imaging were undertaken. As a result, we finally diagnosed as moderately differentiated squamous cell carcinoma without metastases. It is concluded that if ulcerations do not respond to therapy in the usual manner, it should be biopsed and histologically evaluated for the definitive diagnosis and treatment.

  • PDF