• 제목/요약/키워드: Nuclear data libraries

검색결과 31건 처리시간 0.02초

Current Status of ACE Format Libraries for MCNP at Nuclear Data Center of KAERI

  • Kim, Do Heon;Gil, Choong-Sup;Lee, Young-Ouk
    • Journal of Radiation Protection and Research
    • /
    • 제41권3호
    • /
    • pp.191-195
    • /
    • 2016
  • Background: The current status of ACE format MCNP/MCNPX libraries by NDC of KAERI is presented with a short description of each library. Materials and Methods: Validation calculations with recent nuclear data evaluations ENDF/BV-II. 0, ENDF/B-VII.1, JEFF-3.2, and JENDL-4.0 have been carried out by the MCNP5 code for 119 criticality benchmark problems taken from the expanded criticality validation suite supplied by LANL. The overall performances of the ACE format KN-libraries have been analyzed in comparison with the results calculated with the ENDF/B-VII.0-based ENDF70 library of LANL. Results and Discussion: It was confirmed that the ENDF/B-VII.1-based KNE71 library showed better performances than the others by comparing the RMS errors and ${chi}^2$ values for five benchmark categories as well as whole benchmark problems. ENDF/B-VII.1 and JEFF-3.2 have a tendency to yield more reliable MCNP calculation results within certain confidence intervals regarding the total uncertainties for the $k_{eff}$ values. Conclusion: It is found that the adoption of the latest evaluated nuclear data might ensure better outcomes in various research and development areas.

Copper neutron transport libraries validation by means of a 252Cf standard neutron source

  • Schulc, Martin;Kostal, Michal;Novak, Evzen;Simon, Jan
    • Nuclear Engineering and Technology
    • /
    • 제53권10호
    • /
    • pp.3151-3157
    • /
    • 2021
  • Copper is an important structural material in various nuclear energy applications, therefore the correct knowledge of copper cross sections is crucial. The presented paper deals with a validation of different copper transport libraries by means of activation of selected samples. An intense 252Cf(sf) source with a reference neutron spectrum was used as a neutron source. After irradiation, the samples were measured using a high purity germanium detector and the dosimeter reaction rates were inferred. These experimental data were compared with MCNP6 calculations using CENDL-3.1, JENDL-4.0, ENDF/B-VII.1, ENDF/B-VIII.0, JEFF-3.2 and JEFF-3.3 evaluated Cu transport libraries. The experiment specifically focuses on 58Ni(n,p)58Co, 93Nb(n,2n)92mNb, 197Au(n,g)198Au and 55Mn(n,g)56Mn dosimetry reactions. Evaluated activation cross sections of these dosimetric reactions were taken from the IRDFF-II library. The best library performance depends on the energy region of interest.

H.B. Robinson-2 pressure vessel dosimetry benchmark: Deterministic three-dimensional analysis with the TORT transport code

  • Orsi, Roberto
    • Nuclear Engineering and Technology
    • /
    • 제52권2호
    • /
    • pp.448-455
    • /
    • 2020
  • The H.B. Robinson Unit 2 (HBR-2) pressure vessel dosimetry benchmark is an in- and ex-Reactor Pressure Vessel (RPV) neutron dosimetry benchmark based on experimental data from the HBR-2 reactor, a 2300-MW PWR designed by Westinghouse and put in operation in March 1971, openly available through the SINBAD Database at OECD/NEA data Bank. The goals of the present work were to carry out three-dimensional (3D) fixed source transport calculations in both Cartesian (X,Y,Z) and cylindrical (R,θ,Z) geometries by using the TORT-3.2 discrete ordinates code on very detailed 3D HBR-2 geometrical models and to test the latest broad-group coupled (47 neutron groups + 20 photon groups) working cross section libraries in FIDO-ANISN format with same structure as BUGLE-96, such as BUGJEFF311.BOLIB, BUGENDF70.BOLIB and BUGLE-B7. The results obtained with all the cited libraries were satisfactory and are here reported and compared.

Uncertainty quantification of PWR spent fuel due to nuclear data and modeling parameters

  • Ebiwonjumi, Bamidele;Kong, Chidong;Zhang, Peng;Cherezov, Alexey;Lee, Deokjung
    • Nuclear Engineering and Technology
    • /
    • 제53권3호
    • /
    • pp.715-731
    • /
    • 2021
  • Uncertainties are calculated for pressurized water reactor (PWR) spent nuclear fuel (SNF) characteristics. The deterministic code STREAM is currently being used as an SNF analysis tool to obtain isotopic inventory, radioactivity, decay heat, neutron and gamma source strengths. The SNF analysis capability of STREAM was recently validated. However, the uncertainty analysis is yet to be conducted. To estimate the uncertainty due to nuclear data, STREAM is used to perturb nuclear cross section (XS) and resonance integral (RI) libraries produced by NJOY99. The perturbation of XS and RI involves the stochastic sampling of ENDF/B-VII.1 covariance data. To estimate the uncertainty due to modeling parameters (fuel design and irradiation history), surrogate models are built based on polynomial chaos expansion (PCE) and variance-based sensitivity indices (i.e., Sobol' indices) are employed to perform global sensitivity analysis (GSA). The calculation results indicate that uncertainty of SNF due to modeling parameters are also very important and as a result can contribute significantly to the difference of uncertainties due to nuclear data and modeling parameters. In addition, the surrogate model offers a computationally efficient approach with significantly reduced computation time, to accurately evaluate uncertainties of SNF integral characteristics.

An inter-comparison between ENDF/B-VIII.0-NECP-Atlas and ENDF/B-VIII.0-NJOY results for criticality safety benchmarks and benchmarks on the reactivity temperature coefficient

  • Kabach, Ouadie;Chetaine, Abdelouahed;Benchrif, Abdelfettah;Amsil, Hamid
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2445-2453
    • /
    • 2021
  • Since the nuclear data forms a vital component in reactor physics computations, the nuclear community needs processing codes as tools for translating the Evaluated Nuclear Data Files (ENDF) to simulate nuclear-related problems such as an ACE format that is used for MCNP. Errors, inaccuracies or discrepancies in library processing may lead to a calculation that disagrees with the experimentally measured benchmark. This paper provides an overview of the processing and preparation of ENDF/B-VIII.0 incident neutron data with NECP-Atlas and NJOY codes for implementation in the MCNP code. The resulting libraries are statistically inter-compared and tested by conducting benchmark calculations, as the mutualcomparison is a source of strong feedback for further improvements in processing procedures. The database of the benchmark experiments is based on a selection taken from the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP handbook) and those proposed by Russell D. Mosteller. In general, there is quite good agreement between the NECP-Atlas1.2 and NJOY21(1.0.0.json) results with no substantial differences, if the correct input parameters are used.

Analysis of VVER-1000 mock-up criticality experiments with nuclear data library ENDF/B-VIII.0 and Monte Carlo code MCS

  • Setiawan, Fathurrahman;Lemaire, Matthieu;Lee, Deokjung
    • Nuclear Engineering and Technology
    • /
    • 제53권1호
    • /
    • pp.1-18
    • /
    • 2021
  • The criticality analysis of VVER-1000 mock-up benchmark experiments from the LR-0 research reactor operated by the Research Center Rez in the Czech Republic has been conducted with the MCS Monte Carlo code developed at the Computational Reactor Physics and Experiment laboratory of the Ulsan National Institute of Science and Technology. The main purpose of this work is to evaluate the newest ENDF/B-VIII.0 nuclear data library against the VVER-1000 mock-up integral experiments and to validate the criticality analysis capability of MCS for light water reactors with hexagonal fuel lattices. A preliminary code/code comparison between MCS and MCNP6 is first conducted to verify the suitability of MCS for the benchmark interpretation, then the validation against experimental data is performed with both ENDF/B-VII.1 and ENDF/B-VIII.0 libraries. The investigated experimental data comprises six experimental critical configurations and four experimental pin-by-pin power maps. The MCS and MCNP6 inputs used for the criticality analysis of the VVER-1000 mock-up are available as supplementary material of this article.

Neutronics analysis of JSI TRIGA Mark II reactor benchmark experiments with SuperMC3.3

  • Tan, Wanbin;Long, Pengcheng;Sun, Guangyao;Zou, Jun;Hao, Lijuan
    • Nuclear Engineering and Technology
    • /
    • 제51권7호
    • /
    • pp.1715-1720
    • /
    • 2019
  • Jozef Stefan Institute (JSI), TRIGA Mark II reactor employs the homogeneous mixture of uranium and zirconium hydride fuel type. Since its upgrade, a series of fresh fuel steady state experimental benchmarks have been conducted. The benchmark results have provided data for testing computational neutronics codes which are important for reactor design and safety analysis. In this work, we investigated the JSI TRIGA Mark II reactor neutronics characteristics: the effective multiplication factor and two safety parameters, namely the control rod worth and the fuel temperature reactivity coefficient using SuperMC. The modeling and real-time cross section generation methods of SuperMC were evaluated in the investigation. The calculation analysis indicated the following: the effective multiplication factor was influenced by the different cross section data libraries; the control rod worth evaluation was better with Monte Carlo codes; the experimental fuel temperature reactivity coefficient was smaller than calculated results due to change in water temperature. All the results were in good agreement with the experimental values. Hence, SuperMC could be used for the designing and benchmarking of other TRIGA Mark II reactors.

Study on (n,p) reactions of 58Ni, 99Tc, 99Ru, 131Xe, 133Cs and 186Os radioisotopes used in medicine

  • Hallo M. Abdullah;Ali H. Ahmed
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.304-309
    • /
    • 2023
  • In the last decade, nuclear medicine appears to be a good choice of medicine. 58Co, 99Mo, 99Tc, 99Re, 133Xe and 186Re are very important radionuclides for nuclear medicine. In this study, the excitation functions of 58Ni (n, p) 58Co, 99Tc (n, p) 99Mo, 99Ru (n, p) 99Tc, 131Xe (n, p) 131I, 133Cs (n, p) 133Xe and 186Os (n, p) 186Re nuclear reactions were calculated at neutron energies between 1 and 20 MeV using TALYS 1.95 and EMPIRE 3.2 nuclear codes. Furthermore, the cross sections were calculated with the empirical formula derived in our past study at 14-15 MeV. The obtained results were compared with the measured values in EXFOR library, and with the evaluated data of (JENDL-4.0/HE, JEFF-3.3, TENDL-2019, ENDF/B-VIII.0, IRDFF-II, JENDL/ImPACT-18). The results are in good agreement with those of the evaluated data libraries and experimental results and indicates that these radioisotopes can be produced by smaller cyclotrons.

A simple method for estimating the major nuclide fractional fission rates within light water and advanced gas cooled reactors

  • Mills, R.W.;Slingsby, B.M.;Coleman, J.;Collins, R.;Holt, G.;Metelko, C.;Schnellbach, Y.
    • Nuclear Engineering and Technology
    • /
    • 제52권9호
    • /
    • pp.2130-2137
    • /
    • 2020
  • The standard method for calculating anti-neutrino emissions from a reactor involves knowing the fractional fission rates for the most important fissioning nuclides in the reactor. To calculate these rates requires detailed reactor physics calculations based upon the reactor design, fuel design, burnup dependent fuel composition, location of specific fuel assemblies in the core and detailed operational data from the reactor. This has only been published for a few reactors during specific time periods, whereas to be of practical use for anti-neutrino reactor monitoring it is necessary to be able to predict these on the publicly available information from any reactor, especially if using these data to subtract the anti-neutrino signal from other reactors to identify an undeclared reactor and monitor its operation. This paper proposes a method to estimate the fission fractions for a specific reactor based upon publicly available information and provides a database based upon a series of spent fuel inventory calculations using the FISPIN10 code and its associated data libraries.

Monte Carlo Analysis of the Accelerator-Driven System at Kyoto University Research Reactor Institute

  • Kim, Wonkyeong;Lee, Hyun Chul;Pyeon, Cheol Ho;Shin, Ho Cheol;Lee, Deokjung
    • Nuclear Engineering and Technology
    • /
    • 제48권2호
    • /
    • pp.304-317
    • /
    • 2016
  • An accelerator-driven system consists of a subcritical reactor and a controllable external neutron source. The reactor in an accelerator-driven system can sustain fission reactions in a subcritical state using an external neutron source, which is an intrinsic safety feature of the system. The system can provide efficient transmutations of nuclear wastes such as minor actinides and long-lived fission products and generate electricity. Recently at Kyoto University Research Reactor Institute (KURRI; Kyoto, Japan), a series of reactor physics experiments was conducted with the Kyoto University Critical Assembly and a Cockcrofte-Walton type accelerator, which generates the external neutron source by deuteriu-metritium reactions. In this paper, neutronic analyses of a series of experiments have been re-estimated by using the latest Monte Carlo code and nuclear data libraries. This feasibility study is presented through the comparison of Monte Carlo simulation results with measurements.