• Title/Summary/Keyword: Nuclear Sites

Search Result 430, Processing Time 0.019 seconds

A Study on the Insulin Receptor of the Cultured Human Fibroblasts (정상인(正常人) 배양섬유아세포(培養纖維芽細胞)의 인슐린 수용체(受容體)에 관한 연구(硏究))

  • Cho, Kyung-Sam;Kim, Jin-Woo;Kim, Young-Seol;Kim, Kwang-Won;Kim, Sun-Woo;Choi, Young-Kil
    • The Korean Journal of Nuclear Medicine
    • /
    • v.17 no.2
    • /
    • pp.35-40
    • /
    • 1983
  • To evaluated the usefulness of cultured human fibroblast for insulin receptor assay, the authors cultured fibroblast from biopsied normal adult female eyelid skin and assayed the insulin receptor with radioreceptor assay method. From the data obtained, percent of labeled insulin bound, numbers of insulin binding sites, affinity constants(Ka) and affinity of the empty sites(Ke) were calculated. The results were as follow; 1) The percent radioactivity bound of cultured fibroblast reached plateau at 4 hours $15^{\circ}C$ incubation. 2) The scatchard plot of insulin binding to cultured human fibroblast was curvilinear and the affinity to receptor was decreased with increased receptor occupancy. 3) The numbers of high affinity, low affinity and total insulin receptor of cultured fibroblasts were 852, 24,800 and 25,652 sites per cell. 4) High and low affinity constants of cultured fibroblasts were $3.4\times^{10}M^{-1},\;and\;1.08\times10^8M^{-1}$, and the affinity of empty site was $5.0\times10^8M^{-1}$.

  • PDF

Results of Radioiodine Treatment for Distant Metastases of Differentiated Thyroid Carcinoma (분화성 갑상선암의 원격 전이에서 방사성옥소 치료 성적)

  • Kim, Yu-Kyeong;Chung, June-Key;Kim, Seok-Ki;Yeo, Jung-Seok;Park, Do-Joon;Jeong, Jae-Min;Lee, Dong-Soo;Cho, Bo-Youn;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.2
    • /
    • pp.107-118
    • /
    • 2000
  • Purpose: To evaluate the effectiveness of radioiodine treatment for metastatic thyroid carcinoma, we reviewed results of radioactive iodine treatment in patients with functional lung or bone metastases. Materials and Methods: Of 760 patients who were treated for differentiated thyroid cancer between 1984 and 1998, we detected pulmonary metastases and bone metastases in 76 patients (10.0%) and 20 patients (2.6%), respectively. Among them, we could evaluate the effectiveness of I-131 therapy in 53 patients with lung metastases and 15 patients with bone metastases. Results: Of 53 patients who received I-131 therapy with a mean cumulative dose of 26.2 GBq (1.1-84.4 GBq) for pulmonary metastases, metastatic lung lesions completely resolved in 19 patients (35.8%) and improved in 22 patients (41.5%). In 13 of 19 patients with complete remission of pulmonary metastases, the total accumulated dose of I-131 was less than 18.5 GBq. We found 43 sites of metastatic bone lesions in 15 patients with bone metastases. Of 29 lesions which received I-131 therapy, metastatic lesions improved in 14 sites (48.3%), but did not change or progress in 15 sites (51.7%) despite the I-131 therapy. Three lesions were completely cured with a combination treatment of surgery(${\pm}$ external radiotherapy) and I-131 therapy, and the other 11 lesions improved. Conclusion: Radioactive iodine treatment gives favorable results for pulmonary metastases. However, for bone metastases, there might be a need to use combination therapy including I-131 and surgery or external irradiation.

  • PDF

Bone Marrow Scintigraphy with Antigranulocyte Antibody in Multiple Myeloma: Comparison with Simple Radiography and Bone Scintigraphy (항과립구 항체 골수스캔을 이용한 다발성 골수종 병변의 평가: 단순골X-선점사 및 골스캔과의 비교)

  • Kim, Dong-Hwan;Lee, Jae-Tae;Baek, Jin-Ho;Jung, Jin-Tae;Hyun, Dong-Woo;Chun, Kyung-Ah;Lee, Young-Hak;Sohn, Sang-Kyun;Song, Hong-Seok;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.354-364
    • /
    • 1998
  • Purpose: Simple X-ray study and bone scan have limitations for early diagnosis of bone or bone marrow lesions in multiple myeloma. The purpose of this study was to evaluate the diagnostic usefulness of bone marrow immunoscintigraphy using anti-granulocyte monoclonal antibody for the evaluation of bone involvement in multiple myeloma. Materials and Methods: In 22 patients (Male: 15, Female: 7) with multiple myeloma, we performed whole-body immunoscintigraphy using $^{99m}Tc$-labelled antigranulocyte antibody (BW 250/183, Scintimum $Granulozyt^{(R)}$ CIS, France) and compared the findings with those of simple bone radiography and $^{99m}Tc$-MDP bone scan. Abnormal findings in bone marrow scintigraphy were, considered to be present in case of expansion of peripheral bone marrow or focal photon defect in axial bones. Results: Marrow expansion was noted in 15 of 22 patients (68%). Focal photon defects were found in 18 patients (82%). While one (33%) of 3 patients with Stage II disease showed focal defects in bone marrow scan, abnormal focal defects were observed in 17 of 19 (90%) patients with Stage III. Among 124 focal abnormal sites which were observed in bone marrow scan, bone scan or simple bone radiography, bone marrow scan detected 92 sites (74%), whereas 82 sites (66%) were observed in simple bone radiography(58 sites, 47%) or bone scan(40 sites, 32%). Fifty-one (41%) out of 124 bone lesions were detected by bone marrow scan only, and located mostly in thoracolumbar spine. Conclusion: Bone marrow scan using $^{99m}Tc$-labelled antigranulocyte antibody seems to be a more sensitive procedure for the detection of pathologic bone lesions than simple bone X-ray or bone scan in patients with multiple myeloma.

  • PDF

Cold Lesions in $^{99m}Tc$-MDP Bone Scans of Patients with Skeletal Metastases ($^{99m}Tc$-MDP 골스캔에서 냉소로 나타난 전이 암의 분석)

  • Choi, C.W.;Yang, H.I.;Bae, S.K.;Lee, D.S.;Sohn, I.;Chung, J.K.;Lee, M.C.;Koh, C.S.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.1
    • /
    • pp.98-103
    • /
    • 1993
  • The present study was purposed to evaluate the incidence and the characteristics of metastatic "cold" lesions in $^{99m}Tc$-MDP bone scans of adult patients with solid malignancies. There were 29 cold lesions in 24 patients. The incidence of cold lesions was about 1% of total cases of bone scans for the patients with malignancy, or 2.5% of cases with bone metastases. Th primary sites of malignancies were lung (four cases), uterine cervix (three cases), kidney, nasopharynx, thyroid, urinary bladder, prostate, lymphoma (two cases each other), liver, breast and others (one case each other). But the relative incidence of cold lesion in lung cancer and breast cancer was low. The most frequent site of cold lesion was spine, and pelvis, skull and rib were followed. The incidence of cold lesion was related to the regional incidence of bone metastases. The size of the cold lesions was greater than that of the hot. There were six cases of single cold lesion without any other abnormalities and two cases of cold lesion which were initially hot. So it should be considered that bone metastases might be presented as cold lesions in bone scan.

  • PDF

Indigenous Radiosynthesis of [131I]Iodobenzylguanidine ([131I]mIBG) for Neuroblastoma Imaging

  • Nadeem Ahmed Lodhi;Muhammad Irfan;Muhammad Nasir Saddique;Kahkshan Bashir Mir;Naseer Ahmed;Shazia Fatima;Mumtaz Khan;Muhammad Wasim;Samina Roohi
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.8 no.2
    • /
    • pp.71-76
    • /
    • 2022
  • Indigenous diagnostic dose of 131I-labeled meta-iodobenzylguanidine ([131I]mIBG) was prepared via Cu+ catalyzed isotope exchange reaction generated in situ by sodium metabisulfite for imaging of neuroblastoma tumor. [131I]mIBG was produced in overall 85-90% radiochemical yield. The average amount of radioactivity of [131I]mIBG was 2164 MBq (1998-2331MBq) with an average specific activity > 1000 MBq/mg at the end of synthesis. The radiochemical purity was ≥ 99.9% after purification through Dowex-1 × 8 ion exchange resin (100-150 mesh) at the date of preparation. The stability of [131I]mIBG at concentration 480-555 MBq/mL was > 97% at 4 ℃ after 4 days. The room temperature (25 ℃) stability of [131I]mIBG was > 98% after 24 h. Biodistribution of [131I]mIBG in patient showed uptake in salivary glands, liver, spleen and excreted though urinary bladder. Neuroendocrine medicated uptake into tumor lesion and metastatic sites were noted which strongly correlate with the morphological abnormalities of patient.

GABA Receptor Imaging (GABA 수용체 영상)

  • Lee, Jong-Doo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.2
    • /
    • pp.166-171
    • /
    • 2007
  • GABA is primary an inhibitory neurotransmitter that is localized in inhibitory interneurons. GABA is released from presynaptic terminals and functions by binding to GABA receptors. There are two types of GABA receptors, $GABA_{A}-receptor$ that allows chloride to pass through a ligand gated ion channel and $GABA_{B}-receptor$ that uses G-proteins for signaling. The $GABA_{A}$-receptor has a GABA binding site as well as a benzodiazepine binding sites, which modulate $GABA_{A}$-receptor function. Benzodiazepine GABAA receptor imaging can be accomplished by radiolabeling derivates that activates benzodiazepine binding sites. There has been much research on flumazenil (FMZ) labeled with $^{11}C-FMZ$, a benzodiazepine derivate that is a selective, reversible antagonist to GABAA receptors. Recently, $^{18}F-fluoroflumazenil$ (FFMZ) has been developed to overcome $^{11}C's$ short half-life. $^{18}F-FFMZ$ shows high selective affinity and good pharmacodynamics, and is a promising PET agent with better central benzodiazepine receptor imaging capabilities. In an epileptic focus, because the GABA/benzodiazepine receptor amount is decreased, using $^{11}C-FMZ$ PET instead of $^{18}F-FDG$ PET, restrict the foci better and may also help find lesions better than high resolution MR. $GABA_{A}$ receptors are widely distributed in the cerebral cortex, and can be used as an viable neuronal marker. Therefore it can be used as a neuronal cell viability marker in cerebral ischemia. Also, GABA-receptors decrease in areas where neuronal plasticity develops, therefore, $GAB_{A}$ imaging can be used to evaluate plasticity. Besides these usages, GABA receptors are related with psychological diseases, especially depression and schizophrenia as well as cerebral palsy, a motor-related disorder, so further in-depth studies are needed for these areas.

Evaluation of Ground Compaction Using SASW Testing (SASW 시험을 활용한 지반 현장 다짐도 평가)

  • Gunwoong Kim
    • Journal of the Korean Geosynthetics Society
    • /
    • v.22 no.4
    • /
    • pp.9-15
    • /
    • 2023
  • Compaction is performed in civil engineering sites to secure the stability of the ground and prevent settlement. While the process of compaction is crucial, it is also essential to evaluate the degree of compaction after the completion of the process. In domestic sites, the evaluation of compaction is mainly conducted on a small number of spot using point-based tests such as plate load tests and sand cone tests. The methods presented so far allow assessment of surface compaction, but evaluating compaction in deeper layers poses challenges. Moreover, due to the limited coverage of point-based testing, it is difficult to achieve an overall assessment of compaction. As a solution to these issues, the Spectral-Analysis-of-Surface-Waves (SASW) tests were utilized to evaluate compaction. SASW tests offer a broader measurement range compared to point-based tests, and depending on the test setup, this method can provide the stiffness of the ground at greater depths. In this study, SASW tests were conducted in a compacted soil site under different conditions to assess compaction. Additionally, Nuclear Density Gauge tests were conducted concurrently to compare and verify the results of SASW. The research results confirmed the feasibility of evaluating compaction using SASW at the geotechnical site.

Study of Mobility for Radionuclides in Nuclear Facility Sites (원자력 시설물 주변에서의 방사성 오염물 거동 특성 연구)

  • Chang, Seeun;Park, JongKul;Um, Wooyong
    • Economic and Environmental Geology
    • /
    • v.51 no.2
    • /
    • pp.99-111
    • /
    • 2018
  • In this study three target radionuclides ($^{60}Co$, $^{137}Cs$, and $^{125}Sb$) were reacted with solid samples collected from the nuclear facility sites to investigate their sorption and mobility behaviors for preparing unexpected nuclear accidents. The highest sorption distribution coefficients ($K_{ds}$) of target radionuclides ($^{60}Co=947mL/g$, $^{137}Cs=2105mL/g$, $^{125}Sb=81.3mL/g$) were found in topsoil layer under groundwater condition, and the $K_d$ values of three radionuclides decreased in the order of fractured rock and bedrock samples under the same groundwater condition. High $K_d$ values of $^{60}Co$ in topsoil layer and fracture rock resulted from the clay minerals present, and the $K_d$ values decreased 58-69 % under seawater condition due to high ionic strength. $^{137}Cs$ sorption was controlled by the ion exchange reaction with $K^+$ on flayed edge sites (FES) of mica. The $^{137}Cs$ sorption was the most affected by seawater (89-97 % decrease), while $^{125}Sb$ sorption was not much affected by seawater. As the results of column and batch experiments, the retardation factors (R) of $^{137}Cs$, $^{60}Co$, and $^{125}Sb$ were determined about 5400-7400, 2000-2500, and 250-415, respectively, indicating no significant transport for these radionuclides even in fractured zone with groundwater. These results suggest that even in the case of severe nuclear accident at the nuclear facilities the mobility of released radionuclides ($^{60}Co$, $^{137}Cs$, and $^{125}Sb$) can be significantly retarded by the topsoil layer and fractured rock. In addition, the results of this study will be used for the safety and environmental performance assessment of nuclear facilities.

Evaluation of Source Identification Method Based on Energy-Weighting Level with Portal Monitoring System Using Plastic Scintillator

  • Lee, Hyun Cheol;Koo, Bon Tack;Choi, Chang Il;Park, Chang Su;Kwon, Jeongwan;Kim, Hong-Suk;Chung, Heejun;Min, Chul Hee
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.3
    • /
    • pp.117-129
    • /
    • 2020
  • Background: Radiation portal monitors (RPMs) involving plastic scintillators installed at the border inspection sites can detect illicit trafficking of radioactive sources in cargo containers within seconds. However, RPMs may generate false alarms because of the naturally occurring radioactive materials. To manage these false alarms, we previously suggested an energy-weighted algorithm that emphasizes the Compton-edge area as an outstanding peak. This study intends to evaluate the identification of radioactive sources using an improved energy-weighted algorithm. Materials and Methods: The algorithm was modified by increasing the energy weighting factor, and different peak combinations of the energy-weighted spectra were tested for source identification. A commercialized RPM system was used to measure the energy-weighted spectra. The RPM comprised two large plastic scintillators with dimensions of 174 × 29 × 7 ㎤ facing each other at a distance of 4.6 m. In addition, the in-house-fabricated signal processing boards were connected to collect the signal converted into a spectrum. Further, the spectra from eight radioactive sources, including special nuclear materials (SNMs), which were set in motion using a linear motion system (LMS) and a cargo truck, were estimated to identify the source identification rate. Results and Discussion: Each energy-weighted spectrum exhibited a specific peak location, although high statistical fluctuation errors could be observed in the spectrum with the increasing source speed. In particular, 137Cs and 60Co in motion were identified completely (100%) at speeds of 5 and 10 km/hr. Further, SNMs, which trigger the RPM alarm, were identified approximately 80% of the time at both the aforementioned speeds. Conclusion: Using the modified energy-weighted algorithm, several characteristics of the energy weighted spectra could be observed when the used sources were in motion and when the geometric efficiency was low. In particular, the discrimination between 60Co and 40K, which triggers false alarms at the primary inspection sites, can be improved using the proposed algorithm.

Radiation Shielding Analysis for Conceptual Design of HIC Transport Package (HIC 전용 운반용기 개념설계를 위한 방사선 차례해석)

  • Cho Chun-Hyung;Lee Kang-Wook;Lee Yun-Do;Choi Byung-Il;Lee Heung-Young
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.457-463
    • /
    • 2005
  • KHNP(Korea Hydro and Nuclear Power Ltd., Co.) is developing a HIC transport package which is satisfying domestic and IAEA regulations and NETEC(Nuclear Environment Technology Institute) is conducting a conceptual design. In this study, the shielding thickness was calculated using the data from radionuclide assay program which is currently using in nuclear sites and Micro Shield code. Considering the structural safety, carbon steel was chosen as shielding material and the shielding thickness was calculated for 500 R/hr and 100 R/hr at HIC surface, respectively. Through the shielding analysis, it was evaluated that the regulation limit is satisfied when the shielding thickness is 22 cm for 500 R/hr and 17 cm for 100/hr.

  • PDF